• 제목/요약/키워드: tracer gas method

검색결과 67건 처리시간 0.023초

공동주택 화장실의 기계 환기시스템에 관한 연구 (A Study on the Mechanical Ventilation System of Bathroom in Apartment House)

  • 함진식
    • 한국주거학회논문집
    • /
    • 제12권3호
    • /
    • pp.141-148
    • /
    • 2001
  • To design mechanical ventilation for bathroom of apartment houses where air supply and exhaust are taken into consideration, mock-ups of ventilation systems, widely used in bathroom of apartment houses with an area of 100$\textrm{m}^2$, were made and installed in a laboratory. These ventilation mock-ups were available for control of air supply and exhaust, and the sizes of supply openings were 40cm${\times}$1cm, 40cm${\times}$3cm, and 40cm${\times}$5cm. They were installed at five positions, spaced 45cm at a height of 5cm from the floor. The exhaust fan was designed for its operating voltage to be set to five steps(100V, 130V, 150V, 180V and 220V) in order to control its air flow rates. When the size and position of each supply opening were changed with the wind velocity of the exhaust fan set to the step 5, the ventilation rates were measured and analyzed by the concentration decay method of tracer gas method, in order to present an efficient mechanical ventilation system. The results of the study revealed that the ventilations rates would increase in the presence of supply openings, compared to the absence of supply openings, and that the larger the size of the supply opening, the more the ventilation rates. Therefore, it was found necessary to take air supply into consideration.

  • PDF

내부 순환 장치의 크기 및 유속 변화에 따른 혼합특성 (Effect of Geometric and Dynamic Parameters on Mixing Characteristic in an Internal-Loop Apparatus)

  • 최윤찬;김동석
    • KSBB Journal
    • /
    • 제11권4호
    • /
    • pp.405-410
    • /
    • 1996
  • 내부 순환 장치를 대규모화함에 따른 혼합특성의 변화를 추적자의 분산실험을 통하여 고찰하였다. 분산특성을 나타내는 무차원수 Bodenstein 수를 5L, 5 50L, 500L 규모의 세 장치에서 공탑기체속도, 액체 순환속도, 포기관의 높이에 대한 직경비의 변화, 빛 반응관의 직경에 대한 포기관의 직경비의 영향에 따 나타내었다. 5L 규모의 장치에서 Bo 수는 공탑 기체속도의 증가에 따라 증가하다 가스 해리 현상의 발생으로 증가폭이 둔해지는 경향을 나타내었으며, 5 50L와 500L 장치에서는 공탑기체속도의 증가에 따라 Eo 수가 감소하였는데, 이는 역혼합의 영향이 크게 나타난 것으로 판단되었다. 또한, 500L 규모 장 치에서 Eo 수의 변화는 50L 장치에서 보다 낮은 공 탑기체속도하에서 변화하는 것으로 보아 대규모화에 따라 흔합이 더욱 빨리 발생함을 알 수 있었다. 차원 해석을 통하여 각 변수틀간의 상관관계를 구하였고, 회귀분석을 통하여 다음과 같은 결과식을 구하였다.

  • PDF

전산유체역학을 이용한 표준 오리사 설계안에 대한 환기효율성 분석 (Analysis on Ventilation Efficiency of Standard Duck House using Computational Fluid Dynamics)

  • 여욱현;조예슬;권경석;하태환;박세준;김락우;이상연;이승노;이인복;서일환
    • 한국농공학회논문집
    • /
    • 제57권5호
    • /
    • pp.51-60
    • /
    • 2015
  • In Korea, 69.4 % of duck farms had utilized conventional plastic greenhouses. In this facilities, there are difficulties in controlling indoor environments for raising duck. High rearing density in duct farms also made the environmental control difficult resulting in getting more stressed making their immune system weaker. Therefore, a facility is needed to having structurally enough solidity and high efficiency on the environmental control. So, new design plans of duck house have recently been conducted by National Institute of Animal Science in Korea. As a study in advance to establish standard, computational fluid dynamics (CFD) was used to estimate the aerodynamic problems according to the designs by means of overall and regional ventilation efficiencies quantitatively and qualitatively. Tracer gas decay (TGD) method was used to calculate ventilation rate according to the structural characteristics of duck houses including installation of indoor circulation fan. The results showed that natural ventilation rate was averagely 164 % higher than typically designed ventilation rate, 1 AER ($min^{-1}$). Meanwhile, mechanically ventilated duck houses made 81.2 % of summer ventilation rate requirement. Therefore, it is urgent to develop a new duck house considering more structural safety as well as higher efficiency of environmental control.

전산유체역학을 통한 간척지 내 벤로형 온실의 자연환기량 분석 (Analysis of Natural Ventilation Rates of Venlo-type Greenhouse Built on Reclaimed Lands using CFD)

  • 이상연;이인복;권경석;하태환;여욱현;박세준;김락우;조예슬;이승노
    • 한국농공학회논문집
    • /
    • 제57권6호
    • /
    • pp.21-33
    • /
    • 2015
  • Recently, the Korean government announced a new development plan for a large-scale greenhouse complex in reclaimed lands. Wind environments of reclaimed land are entirely different from those of inland. Many standard books for ventilation design didn't include qualitative standard for natural ventilation. In this study, natural ventilation rates were analyzed to suggest standard for ventilation design of venlo type greenhouse built on reclaimed land. CFD (Computational Fluid Dynamics) simulation models were designed according to the number of spans, wind conditions and vent openings. The wind profile at a reclaimed land was designed using ESDU (Engineering Sciences Data Unit) code. Using the designed CFD simulation model, ventilation rates were computed using mass flow rate and tracer gas decay method. Additionally computed natural ventilation rates were evaluated by comparing with ventilation requirements. As a result of this study, ventilation rates were decreased with increasing of the number of spans. Ventilation rates were linearly increased with increasing of wind speed. When the wind speed was $1.0\;m{\cdot}s^{-1}$, only side vent was open and wind direction was $45^{\circ}$, homogeneity of ventilation rate at 0~1 m height is the worst. Finally, chart for computing natural ventilation rate was suggested. The chart was expected to be used for establishing standard of ventilation design.

거주지역 실내공기 특성 및 이산화질소 노출에 관한 연구 (Residence s Exposure to Nitrogen Dioxide and Indoor Air Characteristics)

  • 양원호;배현주;정문호
    • 한국환경보건학회지
    • /
    • 제28권2호
    • /
    • pp.183-192
    • /
    • 2002
  • Indoor air quality is affected by source strength of pollutants, ventilation rate, decay rate, outdoor level and so on. Although technologies exist to measure these factors directly, direct measurements of all factors are impractical in most field studies. The purpose of this study was to develop an alternative methods to estimate these factors by multiple measurements. Daily indoor and outdoor NO$_2$concentrations for 21 days in 20 houses in summer and winter, Seoul. Using a mass balance model and linear regression analysis, penetration factor (ventilation divided by sum of air exchange rate and deposition constant) and source strength factor(emission rate divided by sum of air exchange rate and deposition constant) were calculated. Subsequently, the ventilation and source strength were estimated. During sampling period, geometric mean of natural ventilation was estimated to be 1.10$\pm$1.53 ACH, assuming a residential NO$_2$decay rate of 0.8 hr$^{-1}$ in summer. In winter, natural ventilation was 0.75$\pm$1.31 ACH. And mean source strengths in summer and winter were 14.8ppb/hr and 22.4ppb/hr, respectively. Although the method showed similar finding previous studies, the study did not measure ACH or the source strength of the house directly. As validation of natural ventilations, infiltrations were measured with $CO_2$tracer gas in 18 houses. Relationship between ventilation and infiltration was statistically correlated (Pearson r=0.63, p=0.02).

공동주택 화장실의 급기구 및 배기팬 설치위치에 따른 환기효과에 관한 연구 (A Study on the Ventilation Effect by Various Location of Air Intake and Exhaust Fan of Bathroom in Apartment Housing)

  • 함진식;이광명
    • 한국주거학회논문집
    • /
    • 제15권5호
    • /
    • pp.77-84
    • /
    • 2004
  • The mock-ups of ventilation system, which has been widely adopted for the bathroom with the area of 100 $m^2$ apartment housing, were established and tested to design mechanical ventilation for apartment housing bathroom where air supply exhaust are relatively important. These ventilation mock-ups were capable of controlling intake and exhaust, which has the size of supply openings as 40cm${\times}$1cm, 40cm${\times}$3cm, 40cm${\times}$5cm. They were established at five locations, spaced 40cm from each other at a height of 25cm from the floor. The exhaust fans were located at four corners and center of the ceiling. The results this ventilation effect measurement by different condition are showing that when the size of air supply is bigger and the location is lower, the effect of ventilation was relatively higher. In addition, as the distance between exhaust fan and air supply was farther, the ventilation effect were getting highly efficient.

Analysis on the Age of Air and the Air Change Effectiveness of the Personal Environmental Module System in Intelligent Buildings

  • Cho, Dongwoo
    • Architectural research
    • /
    • 제1권1호
    • /
    • pp.47-53
    • /
    • 1999
  • An interesting of desktop air-conditioning system is the Personal Environmental Module(PEM) System. The PEM system allows the occupant to choose the desired temperature, air volume and direction of the discharged air. In this study, the measurements on the age of air and the air change effectiveness, using the tracer gas method, are carried out to analyze the ventilation performance for provision of fresh air near the breathing zone by the PEM. The relations between the PEM for optimal control and other factors related to indoor air quality, and the ventilation for the PEM are examined. Also, three different supply diffuser types(desktop, floor and ceiling) are compared in view of their ability to distribute supply air to the workstation breathing zone. The desktop diffuser type could deliver air directly to the occupants breathing zone with a high degree of effectiveness. The minimum local age of air was measured in the breathing zone, which is directly supplied with air from the PEM diffusers, and the measured local air change effectiveness of the desktop diffuser in the breathing zone was about 1.13 to 1.23 times greater than that of the ceiling and floor diffusers. When the minimum outside air change rate as specified using ASHRAE Standard 62R is supplied with a desktop diffuser type, the volume of outside air can be reduced 13 to 23%, resulting in a commensurate in ventilation energy use.

  • PDF

인공위성 센서 MOPITT를 이용한 일산화탄소 모니터링: 자료처리 및 응용 (Monitoring of Carbon Monoxide using MOPITT: Data Processing and Applications)

  • 최성득;장윤석
    • 한국대기환경학회지
    • /
    • 제22권6호
    • /
    • pp.940-953
    • /
    • 2006
  • The major source of carbon monoxide (CO) at the Earth's surface is the incomplete combustion of biomass and fossil fuels. Because the global lifetime of CO is about two months, it can be used as a tracer for pollution from anthropogenic activities and biomass hurtling. In this paper, we introduced the principle and algorithm of the Measurement of Pollution in the Troposphere (MOPITT) instrument for global CO monitoring. The MOPITT instrument, which was launched on the Satellite Terra in 1999, measures CO column and mixing ratio based on gas correlation radiometry. CO levels can be determined by a retrieval algorithm based on the maximum likelihood method minimizing the difference between observed and modeled radiances. MOPITT level 2 data (HDF format) can be downloaded through the Earth Observing System (EOS) data gateway of NASA. ASCII files of CO parameters can be extracted from HDF files, and then temporal and spatial distributions can be obtained. Finally, we showed an example of CO monitoring in April 2000. The locations of forest fires and distribution of MOPITT CO clearly indicated that not only anthropogenic emissions but also forest fires play an important role in CO levels and global CO distribution. Our introduction to MOPITT and the example of MOPITT data interpretation would be helpful for scientists who want to use the EOS data.

보온커튼을 설치한 플라스틱 온실의 틈새환기전열량 실측조사 (Experimental Study on the Infiltration Loss in Plastic Greenhouses Equipped with Thermal Curtains)

  • 남상운;신현호
    • 생물환경조절학회지
    • /
    • 제24권2호
    • /
    • pp.100-105
    • /
    • 2015
  • 온실의 난방부하 중 틈새환기전열부하 산정방법은 설계 기준마다 제각각이고, 온실의 규모에 따라 각각의 방법에는 큰 차이가 있으므로 보다 정확히 국내에 적용할 수 있는 방법을 정립할 필요가 있다. 본 연구에서는 원예시설의 환경설계 중 난방부하 산정방법 정립에 필요한 기초자료를 제공할 목적으로 다양한 종류의 보온커튼을 설치한 단동 및 연동 플라스틱 온실에서 추적가스법을 이용하여 틈새환기율을 실측하였으며, 온실의 틈새환기 전열부하 산정방법을 검토하였다. 연동온실의 틈새환기율은 $0.042{\sim}0.245h^{-1}$의 범위로 측정되었으며 단동온실의 틈새환기율은 $0.056{\sim}0.336h^{-1}$의 범위로 측정되어 단동온실이 약간 큰 것으로 나타났다. 온실의 틈새환기율은 단동, 연동 구분없이 보온커튼의 층수에 따라 크게 감소하는 것으로 나타났다. 또한 틈새환기율은 온실의 실내외 기온차가 커질수록 증가하는 경향을 보였으나, 실험기간 동안의 낮은 풍속 범위에서 외부 풍속에 따른 틈새환기율의 변화는 일정한 경향을 찾을 수 없었다. 온실의 난방설계를 위한 틈새환기율은 적정 실내외 기온차에서의 값을 제시할 필요가 있고, 최대난방부하 산정의 기준이 되는 낮은 풍속 범위에서 풍속에 따른 틈새환기율의 변화는 고려하지 않아도 되는 것으로 고찰되었다. 다만 강풍지역에서는 열관류율을 포함하여 최대난방부하를 약간 증가시키는 보정계수의 적용이 필요할 것으로 판단되었다. 온실의 틈새환기전열부하 산정방법을 검토한 결과 틈새환기전열계수와 온실의 피복면적을 이용하는 방법은 문제가 있는 것으로 나타났으며, 틈새환기율과 온실의 체적을 이용하는 방법이 합리적인 것으로 판단되었다.

다연동 온실의 자연환기효율성 비교 분석 (Comparative Study on Efficiencies of Naturally-Ventilated Multi-Span Greenhouses in Korea)

  • 권순홍;정성원;권순구;박종민;최원식;김종순
    • 한국산업융합학회 논문집
    • /
    • 제20권1호
    • /
    • pp.8-18
    • /
    • 2017
  • This research analyzed the ventilation effect of the multi-span greenhouse based on the types of greenhouse structure, weather conditions, and locations inside the greenhouse. To compare and analyze the ventilation effects with different types of greenhouse, the uniform environmental conditions should be selected in advance. But these factors are not controlled and require tense many precision facilities and labor forces. Thus, the CFD simulation was used for the air stream to be analyzed qualitatively and quantitatively. In addition, for the ventilation effect analysis, the TGD (Tracer Gas Decay) was used to overcome the shortcomings of the current ventilation measurement method. The calculation error of ventilation rate using TGD was low (10.5%). Thus, the TGD is very effective in calculating the ventilation efficiency. The wind direction of 90 degrees showed the best ventilation effect. The ventilation rate also decreased along the air circulation path, and the rate was the lowest around the outlet. The computed fluid method (CFD) turned out to be a power tool for simulating flow behavior in greenhouse.