• Title/Summary/Keyword: trace formulas

Search Result 8, Processing Time 0.021 seconds

Spectra of Higher Spin Operators on the Sphere

  • Doojin Hong
    • Kyungpook Mathematical Journal
    • /
    • v.63 no.1
    • /
    • pp.105-122
    • /
    • 2023
  • We present explicit formulas for the spectra of higher spin operators on the subbundle of the bundle of spinor-valued trace free symmetric tensors that are annihilated by Clifford multiplication over the standard sphere in odd dimension. In the even dimensional case, we give the spectra of the square of such operators. The Dirac and Rarita-Schwinger operators are zero-form and one-form cases, respectively. We also give eigenvalue formulas for the conformally invariant differential operators of all odd orders on the subbundle of the bundle of spinor-valued forms that are annihilated by Clifford multiplication in both even and odd dimensions on the sphere.

Improvement in Plume Dispersion Formulas for Stack Emissions Using Ground-based Imaging-DOAS Data

  • Lee, Hanlim;Ryu, Jaeyong;Jeong, Ukkyo;Noh, Youngmin;Shin, Sung Kyun;Hong, Hyunkee;Kwon, Soonchul
    • Bulletin of the Korean Chemical Society
    • /
    • v.35 no.12
    • /
    • pp.3427-3432
    • /
    • 2014
  • This study introduces a new method of combining Imaging Differential Optical Absorption Spectroscopy (Imaging-DOAS) data and plume dispersion formulas for power plant emissions to determine the three-dimensional structure of a dispersing pollution plume and the spatial distributions of trace gas volume mixing ratios (VMRs) under conditions of negligible water droplet and aerosol effects on radiative transfer within the plume. This novel remote-sensing method, applied to a power plant stack plume, was used to calculate the two-dimensional distributions of sulfur dioxide ($SO_2$) and nitrogen dioxide ($NO_2$) VMRs in stack emissions for the first time. High $SO_2$ VMRs were observed only near the emission source, whereas high $NO_2$ VMRs were observed at locations several hundreds of meters away from the initial emission. The results of this study demonstrate the capability of this new method as a tool for estimating plume dimensions and trace gas VMRs in power plant emissions.

An Analytical Study on the Structural Behavior of Composite Beams (합성보의 거동에 관한 해석적 연구)

  • 황영서;양구록;송준엽;권영봉
    • Proceedings of the Computational Structural Engineering Institute Conference
    • /
    • 1998.10a
    • /
    • pp.175-182
    • /
    • 1998
  • An analytical study to trace the nonlinear structural behavior of composite beams is undertaken to include the nonlinear material properties of steel sheeting, reinforcing steel bar and concrete. To trace Moment-curvature relations, sectioning analysis method and two simple formulas are developed. A simple power model which has been originally used to expect the flexural capacity of the beam to column connections is proposed and the second formula is composed of two experimental functions to express the Moment-curvature relation in the elastic and plastic range separately. The load-deflection behavior of the beams has been simulated by the step-by-step numerical integration method and is compared with the test results available.

  • PDF

Practical Predictive Formulas for Residual Strengths of Fire-Damaged Normal Strength Reinforced Concrete Square Columns (화해를 입은 보통강도 철근콘크리트 정방형 기둥의 실용 잔존내력식)

  • Lee, Cha-Don;Lee, Seung-Whan;Lee, Chang-Eun
    • Journal of the Korea Concrete Institute
    • /
    • v.18 no.1 s.91
    • /
    • pp.3-12
    • /
    • 2006
  • The behavior of concrete structures subject to fire is complex, depending on many factors. The factors usually considered in research include the level and endurance of temperatures in concrete and reinforcing bars, the mechanical properties of the steel and concrete, moisture contents, cover thickness, existence of eccentricity, and member geometry among others. Although there are a few sophisticated numerical models which can trace the effects of these important parameters on the residual capacity of reinforced concrete columns damaged by fire, practical predictive formulas are in need for rapid yet reasonable assessment in practice. The practical formulas are developed in this study for fire-damaged normal strength reinforced concrete square columns, which can approximate the predictions of those sophisticated numerical models with ease in use. The formulas take into account the effects of exposure time to fire, concrete strength, reinforcement ratio and sectional area. The developed formulas are seen to correlate with the predictions of numerical model in a reasonable agreement. Some examples are also presented in determining the residual strength, safety and additionally needed strengths for a fire-damaged reinforced concrete column.

A study on application of high strength steel SM570 in bridge piers with stiffened box section under cyclic loading

  • Kang, Lan;Suzuki, Motoya;Ge, Hanbin
    • Steel and Composite Structures
    • /
    • v.26 no.5
    • /
    • pp.583-594
    • /
    • 2018
  • Although a lot of experimental and analytical investigations have been carried out for steel bridge piers made of SS400 and SM490, the formulas available for SS400 and SM490 are not suitable for evaluating ultimate load and deformation capacities of steel bridge piers made of high strength steel (HSS) SM570. The effect of various parameters is investigated in this paper, including plate width-to-thickness ratio, column slenderness ratio and axial compression force ratio, on the ultimate load and deformation capacities of steel bridge box piers made of SM570 steel subjected to cyclic loading. The elasto-plastic behavior of the steel bridge piers under cyclic loads is simulated through plastic large deformation finite element analysis, in which a modified two-surface model (M2SM) including cyclic hardening is employed to trace the material nonlinearity. An extensive parametric study is conducted to study the influences of structural parameters on the ultimate load and deformation capacities. Based on these analytical investigations, new formulas for predicting ultimate load and deformation capacities of steel bridge piers made of SM570 are proposed. This study extends the ultimate load and deformation capacities evaluation of steel bridge piers from SS400, SM490 steels to SM570 steel, and provides some useful suggestions.

Numerical simulation of external pre-stressed steel-concrete composite beams

  • Moscoso, Alvaro M.;Tamayo, Jorge L.P.;Morsch, Inacio B.
    • Computers and Concrete
    • /
    • v.19 no.2
    • /
    • pp.191-201
    • /
    • 2017
  • External pre-stressing is often used in strengthening or retrofitting of steel-concrete composite beams. In this way, a proper numerical model should be able to trace the completely nonlinear response of these structures at service and ultimate loads. A three dimensional finite element model based on shell elements for representing the concrete slab and the steel beam are used in this work. Partial interaction at the slab-beam interface can be taken into account by using special beam-column elements as shear connectors. External pre-stressed tendons are modeled by using one-dimensional catenary elements. Contact elements are included in the analysis to represent the slipping at the tendon-deviator locations. Validation of the numerical model is established by simulating seven pre-stressed steel-concrete composite beams with experimental results. The model predictions agree well with the experimental results in terms of collapse loads, path failures and cracking lengths at negative moment regions due to service loads. Finally, the accuracy of some simplified formulas found in the specialized literature to predict cracking lengths at interior supports at service loading and for the evaluation of ultimate bending moments is also examined in this work.

Development Rapid Analytical Methods for Inositol as a Trace Component by HPLC and LC-MS/MS in Infant Formula

  • Shin, Jin-Ho;Park, Jung-Min;Kim, Ha-Jung;Ahn, Jang-Hyuk;Kwak, Byung-Man;Kim, Jin-Man
    • Food Science of Animal Resources
    • /
    • v.35 no.4
    • /
    • pp.466-472
    • /
    • 2015
  • A rapid and simple analytical method, using liquid chromatography tandem mass spectrometry (LC-MS/MS), was developed to detect myo-inositol (MI) in infant formulas. For protein removal: acid hydrolysis and lipid removal through organic solvent extraction. The operating conditions for instrumental analysis were determined based on previously reported analogous methods that used LC-MS/MS. Quantitative analysis was used for the detection limit test, infant formula recovery test, and standard reference material (SRM) 1849a to verify the validity of our LC-MS/MS analytical method, which was developed to quantify MI. For validation, the results of our method were compared with the results of quantitative analyses of certified values. The test results showed that the limit of detection was 0.05 mg/L, the limit of quantitation was 0.17 mg/L, and the method detection limit was 17 mg/kg. The recovery test exhibited a recovery between 98.07-98.43% and a relative standard deviation between 1.93-2.74%. Therefore, the result values were good. Additionally, SRM 1849a was measured to have an MI content of 401.84 mg/kg and recovery of 98.25%, which is comparable to the median certified value of 409 mg/kg. From the aforementioned results, we judged that the instrumental analysis conditions and preparation method used in this study were valid. The rapid analytical method developed herein could be implemented in many laboratories that seek to save time and labor.