• Title/Summary/Keyword: tower system

Search Result 843, Processing Time 0.029 seconds

A Critical Review of the Transfer of Presidential Security Work to the Police (대통령경호업무 경찰 이관에 대한 비판적 소고)

  • Jo, Sung-gu
    • Korean Security Journal
    • /
    • no.58
    • /
    • pp.177-194
    • /
    • 2019
  • Last year, the Moon Jae-In administration made an attempt to abolish the presidential security office overseeing the presidential security and to transfer the work to the presidential security service under the National Police Agency. Currently, all of the G7 nations maintain a security system spearheaded by the police, so the policy of transferring the presidential security to the National Police Agency may be discussed. However, it is necessary to focus on the following reality. First, the current presidential security system is consisted of the overlapping security organizations classified into (1) inner ring of the presidential security agency, (2) middle ring of the police agency, and (3) outer ring of the capital defense command. If the presidential security agency is abolished, a vacuum will result as per the principle of class. Second, for the efficient security guard of the President, currently, the presidential security agency at the Presidential Security Safety Measure Committee plays the role of coordinating the tasks. If the National Police Agency becomes the control tower of the presidential security, whether command will be available for the military and diplomatic aspects of the presidential security work should also be considered. Third, Korea is currently in a truce with North Korea, so there is a big difference in terms of the security environment with such G7 nations as the UK, Germany, France, and Japan.

A Study on Multi-Facilities Location Decision Model in Perspective of SCM (SCM관점의 복수시설물 입지결정모형에 관한 연구)

  • Park, Dae-Seok;Zhang, Tao
    • Journal of Distribution Science
    • /
    • v.6 no.1
    • /
    • pp.47-62
    • /
    • 2008
  • Joining the WTO in 2001, China became a number of the global economic system. China succeeded in vying to host Beijing 2008 Olympic Games and World Expo 2010 Shanghai. It is China's honor and opportunity to have high economic growth in the coming future. In 2007, the total cost of public logistics decreased by 18.2% than 2006 to 4540.6 billion RMB, accounting for 18.4% of the GDP. So, China logistics is a huge industry and a growing market full of charm. The statistic ratios of China's logistics and growth trends show us it is an important issue to build and run an effective logistics system. However, research on China's logistics systems and supply chain is lacked. This study is focus on the logistic location strategy in China including the study of factories and warehouses geographic strategy concerned with SCM. The core of this study is to propose a New Multi-Facilities Location Decision Model. This study banded the revised gravity center, the standard single facility location decision model(Gravity Center Model) and the transportation model into a new Multi-Facilities Location Decision Model. In addition, this study suggested the gravity center of population, the gravity center of each industry, the location decision graded-list of each industry of china using the gravity center model and the revised gravity center model. The new Multi-Facilities Location Decision Model proposed in this study can be used to solve the location decision problem of more than two facilities. And it can be used in the fields such as the location decision of production facility and service facility, the location of distribution and logistics, the location of broadcast and satellite communications, the location of wireless communication tower and so on.

  • PDF

Harvesting Cost of Tree-length Thinning in a Larix leptolepis Stands (낙엽송 간벌작업에서 전간수확시스템의 작업비용 분석)

  • Cho, Koo-Hyun;Cho, Min-Jae;Han, Han-Sup;Han, Sang-Kyun;Cha, Du-Song
    • Journal of Korean Society of Forest Science
    • /
    • v.104 no.2
    • /
    • pp.221-229
    • /
    • 2015
  • The purpose of study was to broaden our knowledge on the productivity and cost of thinning operations which has become increasingly practiced in Korea. The thinning operations were conducted in a 40-year old larch (Larix leptolepis) stand, including chainsaw felling and processing at the stump, followed by yarding tree-length logs using a Koller K301-4 tower yarder. The logs were further processed and sorted into 1.8 m and 3.6 m log piles at the landing. We used a standard time study method to evaluate key variables that affect the productivity of thinning operations. The total stump-to-pile operational cost was $41,707won/m^3$. The highest cost activity was the yarding phase which cost $20,083won/m^3$ (48.2% of the total cost), followed by the costs of processing treelength materials into marketable log lengths ($12,143won/m^3$; 29.1%), and then by the costs of sorting/piling the processed logs ($5,039won/m^3$; 12.1%). It was interesting to see that felling and processing trees at the stump had low costs at $1,315won/m^3$ (3.2%) and $3,127won/m^3$ (7.5%), respectively. We used the detailed time study data to develop regression equations which were to predict yarding productivity. Our analysis showed that harvesting system cost was highly sensitive to the number of logs, yarding distance and lateral distance per turn, respectively.

A Study on the Treatment of Wastewater from Ion Removal Process for Purifying Electrocoat Paint in the Bath by Use of Reverse Osmosis (역삼투압을 이용한 전착도료 정제공정폐수처리에 관한 연구)

  • 김진성
    • Membrane Journal
    • /
    • v.8 no.2
    • /
    • pp.77-85
    • /
    • 1998
  • To treat effectively EDIR (electrodeposition ion removal) wastewater in terms of CO$_{Mn}$ 1,500~2,000 ppm generated from aluminum painting process, a RO (reverse osmosis) process was designed and installed to recover and reuse the concentrated solvent sent back to the electrocodeposition tank while the permeate reused as rinse water. A RO system in which three polyamide-spiral wound modules ($102\Phi \times 1,016L$ mm) connnected in series had been running to treat 20 m$^3$ in waste volume in 3 days batch operation at the condition of system recovery of 30 %, applied pressure 11.5 $kg_f/cm^2$ and room temperature. During 42 hours continuous operation leading to 5-fold decrease in waste volume, nearly constant permeation flux of 390 l/m$^2$-hr was maintained and the permeate with average CO$_{Mn}$, 300 ppm was obtained which could be used for washing the remaining paint solution in ion-exchange tower instead of demineralized water. Also COD$_{Mn}$ rejection as a function of running time was observed to be in the range of 78~87 % and the observed solvent rejections for ethyl cellusolve, buthyl cellusolve and n-butanol were 79 %, 87 % and 70 %, respectively.

  • PDF

Study on the Air Insulation Design Guideline for ±500 kV Double Bipole Transmission Line with Metallic Return Conductor (도체귀로형 ±500 kV Double Bipole 송전선로 공기절연에 관한 연구)

  • Shin, Kooyong;Kwon, Gumin;Song, Seongwhan;Woo, Jungwook
    • KEPCO Journal on Electric Power and Energy
    • /
    • v.5 no.3
    • /
    • pp.141-147
    • /
    • 2019
  • Recently, the biggest issue in the electricity industry is the increase in renewable energy, and various technologies are being developed to ensure the capacity of the power system. In addition, super-grids linking power systems are being pushed to utilize eco-friendly energy between countries and regions worldwide. The HVDC transmission technology is required to link the power network between regions with different characteristics of the power system such as frequency and voltage. Until now, Korea has applied HVDC transmission technology that connects mainland and Jeju Island with submarine cables. But, the HVDC transmission technology is still developing for long-distance high-capacity power transmission from power parks on the east coast to load-tight areas near the metropolitan area. Considering the high population density and mountainous domestic environment, it is pushing for commercialization of the design technology of the ${\pm}500kV$ Double Bipole with metallic return wire transmission line to transmit large-scale power of 8 GW using minimal right of ways. In this paper, the insulation characteristics were studied for the design of double-bipole transmission tower with metallic return wire, which is the first time in the world. And the air insulation characteristics resistant to the various overvoltage phenomena occurring on transmission lines were verified through a full-scale impulse voltage test.

Korea's Defense Industry Export Strategy to Enter the World's Big4 - Focusing on Securing Cutting-edge Technology and Joint Research and Development (한국 방산수출 세계 빅4 진입 전략 -첨단기술 확보와 공동연구개발을 중심으로)

  • PARK JUNG HWAN
    • The Journal of the Convergence on Culture Technology
    • /
    • v.10 no.1
    • /
    • pp.227-233
    • /
    • 2024
  • Korea achieved its highest ever defense export performance in 2022. Defense exports are the most effective way to promote the defense industry by exporting Korea's weapons to foreign countries. In addition, to continuously supply excellent weapon systems, a solid defense industry must be established. So defense industry exports are an important issue at the national level, the Korea government is actively supporting policies for the Presidential office as a control tower. In particular, the topic of entry into the defense industry export big4 is being raised in Korea. As an innovative defense export promotion plan, this paper presents a strategic plan of joint research and development that export customized to the needs of purchasing countries and securing cutting-edge technology that can possess world-class weapon systems. In other words, in order to secure cutting-edge technology, the military must break away from existing methods and boldly select cutting-edge technology, provide sufficient budget support, and grant autonomy to development agencies. A rapid acquisition system must also be introduced so that this technology can be applied to advanced weapons in a timely manner. Export joint research and development is intended to promote flexible technology transfer excluding ultra-sensitive core technologies and to form strategic partnerships, taking into account the purchasing country's willingness to possess cutting-edge technology. Through this, we have helped Korea's defense industry exports enter the world's big4 through groundbreaking new strategy.

CO2 Exchange in Kwangneung Broadleaf Deciduous Forest in a Hilly Terrain in the Summer of 2002 (2002년 여름철 경사진 광릉 낙엽 활엽수림에서의 이산화탄소 교환)

  • Choi, Tae-jin;Kim, Joon;Lim, Jong-Hwan
    • Korean Journal of Agricultural and Forest Meteorology
    • /
    • v.5 no.2
    • /
    • pp.70-80
    • /
    • 2003
  • We report the first direct measurement of $CO_2$ flux over Kwangneung broadleaf deciduous forest, one of the tower flux sites in KoFlux network. Eddy covariance system was installed on a 30 m tower along with other meteorological instruments from June to August in 2002. Although the study site was non-ideal (with valley-like terrain), turbulence characteristics from limited wind directions (i.e., 90$\pm$45$^{\circ}$) was not significantly different from those obtained at simple, homogeneous terrains with an ideal fetch. Despite very low rate of data retrieval, preliminary results from our analysis are encouraging and worthy of further investigation. Ignoring the role of advection terms, the averaged net ecosystem exchange (NEE) of $CO_2$ ranged from -1.2 to 0.7 mg m$^{-2}$ s$^{-1}$ from June to August in 2002. The effect of weak turbulence on nocturnal NEE was examined in terms of friction velocity (u*) along with the estimation of storage term. The effect of low uf u* NEE was obvious with a threshold value of about 0.2 m s$^{-1}$ . The contribution of storage term to nocturnal NEE was insignificant; suggesting that the $CO_2$ stored within the forest canopy at night was probably removed by the drainage flow along the hilly terrain. This could be also an artifact of uncertainty in calculations of storage term based on a single-level concentration. The hyperbolic light response curves explained >80% of variation in the observed NEE, indicating that $CO_2$ exchange at the site was notably light-dependent. Such a relationship can be used effectively in filling up the missing gaps in NEE data through the season. Finally, a simple scaling analysis based on a linear flow model suggested that advection might play a significant role in NEE evaluation at this site.

A Study on the Hydraulic Characteristics of Rashig Super-Ring Random Packing in a Counter-Current Packed Tower (역류식 충전탑에서 Raschig Super-ring Random Packing의 수력학적 특성에 대한 연구)

  • Kang, Sung Jin;Lim, Dong-Ha
    • Clean Technology
    • /
    • v.26 no.2
    • /
    • pp.102-108
    • /
    • 2020
  • In recent years, packed column has been widely used in separation processes, such as absorption, desorption, distillation, and extraction, in the petrochemical, fine chemistry, and environmental industries. Packed column is used as a contacting facility for gas-liquid and liquid-liquid systems filled with random packed materials in the column. Packed column has various advantages such as low pressure drop, economical efficiency, thermally sensitive liquids, easy repairing restoration, and noxious gas treatment. The performance of a packed column is highly dependent on the maintenance of good gas and liquid distribution throughout a packed bed; thus, this is an important consideration in a design of packed column. In this study, hydraulic pressure drop, hold-up as a function of liquid load, and mass transfer in the air, air/water, and air-NH3/water systems were studied to find the geometrical characteristic for raschig super-ring experiment dry pressure drop. Based on the results, design factors and operating conditions to handle noxious gases were obtained. The dry pressure drop of the random packing raschig super-ring was linearly increased as a function of gas capacity factor with various liquid loads in the Air/Water system. This result is lower than that of 35 mm Pall-ring, which is most commonly used in the industrial field. Also, it can be found that the hydraulic pressure drop of raschig super-ring is consistently increased by gas capacity factor with various liquid loads. When gas capacity factor with various liquid loads is increased from 1.855 to 2.323 kg-1/2 m-1/2 S-1, hydraulic pressure drop increases around 17%. Finally, the liquid hold-up related to packing volume, which is a parameter of specific liquid load depending on gas capacity factor, shows consistent increase by around 3.84 kg-1/2 m-1/2 S-1 of the gas capacity factor. However, liquid hold-up significantly increases above it.

Recent Progress in Air Conditioning and Refrigeration Research -A Review of Papers Published in the Korean Journal of Air-Conditioning and Refrigeration Engineering in 2000 and 2001- (공기조화, 냉동 분야의 최근 연구 동향 -2000년 및 2001년 학회지 논문에 대한 종합적 고찰 -)

  • 강신형;한화택;조금남;이승복;조형희;김민수
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.14 no.12
    • /
    • pp.1102-1139
    • /
    • 2002
  • A review on the papers published in the Korean Journal of Air-Conditioning and Refrigerating Engineering in 2000 and 2001 has been done. Focus has been put on current status of research in the aspect of heating, cooling, ventilation, sanitation and building environment. The conclusions are as follows. (1) Most of fundamental studies on fluid flow were related with heat transportation of facilities. Drop formation and rivulet flow on solid surfaces were interesting topics related with condensation augmentation. Research on micro environment considering flow, heat, humidity was also interesting for comfortable living environment. It can be extended considering biological aspects. Development of fans and blowers of high performance and low noise were continuing topics. Well developed CFD technologies were widely applied for developing facilities and their systems. (2) Most of papers related with heat transfer analysis and heat exchanger shows dealt with convection, evaporation, and channel flow for the design application of heat exchanger. The numerical heat transfer simulation studies have been peformed and reported to show heat transfer characteristics. Experimental as well as numerical studies on heat exchanger were reported, while not many papers are available for the system analysis including heat exchanger. (3) A review of the recent studies on heat pump system shows that performance analysis and control of heat pump have been peformed by various simulations and experiments. The research papers on multi-type heat pump system increased significantly. The studies on heat pipe have been examined experimently for change of working characteristics and strut lure. Research on the phase change has been carried out steadily and operation strategies of encapsulated ice storage tank are reported experimentally in several papers. (4) A review of recent studies on refrigeration/air conditioning system have focused on the system performance and efficiency for new alternative refrigerants. Evaporation and condensation heat transfer characteristics are investigated for tube shapes and new alternative refrigerants. Studies on components of refrigeration/air conditioning system are carried to examine efficiency for various compressors and performance of new expansion devices. In addition to thermophysical properties of refrigerant mixtures, studies on new refrigerants are also carried out, however research works on two-phase flow seemed to be insufficient. (5) A review of the recent studies on absorption cooling system indicates that heat and mass transfer phenomena have been investigated to improve absorber performance. Various experimental data have been presented and several simulation models have been proposed. A review of the recent studies on duct and ventilation shows that ventilation indices have been proposed to quantify the ventilation performance in buildings and tunnels. Main efforts have been focused on the applications of ventilation effectiveness in practice, either numerically using computational fluid dynamics or experimentally using tracer gas techniques. (6) Based on a review of recent studies on indoor thermal environment and building service systems, research issues have mainly focused on many innovative ideas such as underfloor air-conditioning system, personal environmental modules, radiant floor cooling and etc. Also, the new approaches for minimizing energy consumption as well as improving indoor environmental conditions through predictive control of HVAC systems, various activities of building energy management and cost-benefit analysis for economic evaluation were highlighted.

Development of VOCs Treatment Technology using High Efficiency Hybrid System with Multi-Scrone (멀티 선회류식 세정장치를 이용한 고효율 하이브리드 VOCs 습식처리 SYSTEM 개발)

  • Lim, Seong-Il;Kim, Nor-Jung;Kim, Sun-Mi;Lee, Seong-Hun;Kim, Sun-Uk;Chang, Won-Seok;Park, Dae-Won;Kim, Lae-Hyun;Kim, Jae-Hyung
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.31 no.7
    • /
    • pp.491-498
    • /
    • 2009
  • We studied to develop high-efficiency removal system of odor and VOCs(Volatile Organic Compounds) from environmental infrastructure facilities and oil refineries, painting facilities and so on. It can replace RTO and RCO. We tried an removal experiment for VOCs (toluene, xylene, benzene, MEK(methyl ethyl ketone), ethanol, formalin etc. and odor compounds (hydrogen sulfide, etc.). In process, as pre-treatment we used the scrubber with vortex flow (Multi-scrone) to remove the hydrophilic VOCs and as post-treatment, used fibrous bio-filter to remove the hydrophobic VOCs. This hybrid system remove with high efficiency both the hydrophilic VOCs and hydrophobic VOCs. And we tried to make this system to be compact. In experiment using Multi-scrone, contact time is 2~3 seconds and absorption scrubbing water is diaphragm-type electrolysis water. hydrophilic VOCs like ethanol and relatively hydrophilic odor compounds like hydrogen sulfide is excellent, these substances has been removed almost completely, respectively 95~99%, 93~97%. And for MEK, formalin also Showed a high removal efficiency, respectively 78~90%, 72~85%. But in experiment using Multi-scrone, the hydrophobic VOCs like BTX showed a low removal efficiency, respectively 16~22%, 12~18%, 8~16%. In hydrophobic VOCs, toluene removal experiment using fibrous bio-filter, early efficiency was low but after 10days, adaptation period showed high efficiency 85~95%. but in the mixed phase, toluene and MEK efficiency reduced 5~10%. this show microorganism treat first MEK easy to remove. The removal efficiency for MEK using the fibrous biofilter was stable, 80~92%. This hybrid system is also high economical efficiency for RTO. This system reduce more than 50% the cost of equipment and maintenance. As a result, we expect this technology is in the limelight as high efficiency treatment of VOCs in mid-low price.