• Title/Summary/Keyword: tower

Search Result 2,235, Processing Time 0.023 seconds

Research on vibration control of a transmission tower-line system using SMA-BTMD subjected to wind load

  • Tian, Li;Luo, Jingyu;Zhou, Mengyao;Bi, Wenzhe;Liu, Yuping
    • Structural Engineering and Mechanics
    • /
    • v.82 no.5
    • /
    • pp.571-585
    • /
    • 2022
  • As a vital component of power grids, long-span transmission tower-line systems are vulnerable to wind load excitation due to their high flexibility and low structural damping. Therefore, it is essential to reduce wind-induced responses of tower-line coupling systems to ensure their safe and reliable operation. To this end, a shape memory alloy-bidirectional tuned mass damper (SMA-BTMD) is proposed in this study to reduce wind-induced vibrations of long-span transmission tower-line systems. A 1220 m Songhua River long-span transmission system is selected as the primary structure and modeled using ANSYS software. The vibration suppression performance of an optimized SMA-BTMD attached to the transmission tower is evaluated and compared with the effects of a conventional bidirectional tuned mass damper. Furthermore, the impacts of frequency ratios and SMA composition on the vibration reduction performance of the SMA-BTMD are evaluated. The results show that the SMA-BTMD provides superior vibration control of the long-span transmission tower-line system. In addition, changes in frequency ratios and SMA composition have a substantial impact on the vibration suppression effects of the SMA-BTMD. This research can provide a reference for the practical engineering application of the SMA-BTMD developed in this study.

Dynamic response of an overhead transmission tower-line system to high-speed train-induced wind

  • Zhang, Meng;Liu, Ying;Liu, Hao;Zhao, Guifeng
    • Wind and Structures
    • /
    • v.34 no.4
    • /
    • pp.335-353
    • /
    • 2022
  • The current work numerically investigates the transient force and dynamic response of an overhead transmission tower-line structure caused by the passage of a high-speed train (HST). Taking the CRH2C HST and an overhead transmission tower-line structure as the research objects, both an HST-transmission line fluid numerical model and a transmission tower-line structure finite element model are established and validated through comparison with experimental and theoretical data. The transient force and typical dynamic response of the overhead transmission tower-line structure due to HST-induced wind are analyzed. The results show that when the train passes through the overhead transmission tower-line structure, the extreme force on the transmission line is related to the train speed with a significant quadratic function relationship. Once the relative distance from the track is more than 15 m, the train-induced force is small enough to be ignored. The extreme value of the mid-span dynamic response of the transmission line is related to the train speed and span length with a significant linear functional relationship.

Effect of Filler on the Flow of Counter Flow Type Cooling Tower (충진재(Filler)가 대향류형(Counter Flow Type) 냉각탑 유동에 미치는 영향에 대한 연구)

  • Shin, Jeong-Hoon;Lee, Jun-Kyoung;Jin, Cheol-Gyu
    • Journal of the Korean Society of Industry Convergence
    • /
    • v.25 no.4_2
    • /
    • pp.565-572
    • /
    • 2022
  • The white plume from the cooling tower can be generated by mixing between discharging hot and humid air and cold air outside. This causes various problems such as icing, traffic disturbances, and fire factors in the vicinity, moreover it can also damage the image of a company. Various methods can be used to prevent white plume, one of them is to install a heat exchanger at the outlet of the cooling tower so that the heat exchanger transfers as much heat as possible to lower the temperature. Therefore the air flow path in the cooling tower should be optimized. Installation of the filler can be used to make the air flow better, thus we investigate the effect of filler on the air flow using CFD method. The pressure and velocity profile in the cooling tower could be acquired by the calculations. The filler made the velocity of the air entering the heat exchanger uniform this was because high flow resistance of the filler suppresses the generation of eddy in the cooling tower. But the total air pressure drop increased about 2 times with filler because the pressure drop by the filler accounted for about 60% of the total pressure drop.

The Diagnosis of Cooling Tower System (Cooling Tower System 진동 진단)

  • Lee, Sun-Hwi
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2007.11a
    • /
    • pp.1090-1094
    • /
    • 2007
  • The aim of this study is to estimate the cause of Cooling Tower vibration and eliminate the faults of fan with high vibration in spite of overhaul. The cause of high vibration was that the natural frequency of fan blade coincide with second blade pass frequency. To achieve reduction of Cooling Tower vibration, change motor speed from 1784rpm to 1714rpm, and then the vibration has reduced conspicuously.

  • PDF

A Study on the Safety Assessment Method of the Adversiting Pillar Tower on the Penthouse (옥탑에 설치된 광고탑 구조물의 안전성 평가 기법에 관한 연구)

  • 채원규
    • Proceedings of the Korean Institute of Industrial Safety Conference
    • /
    • 1998.05a
    • /
    • pp.221-226
    • /
    • 1998
  • In this thesis, the safety assessment method of tile adversiting pillar tower on the penthouse were studied. From the structural analysis results of the adversiting pillar tower, the bending stress, the shearing stress and the axial stress were calculated, and these member forces were applied to the safety assessment of the adversiting pillar tower and the penthouse, respectively.

  • PDF

A Case Study on the Structural Safety Evaluation of a building with Adversiting Pillar Tower (광고탑이 설치된 건축 구조물의 구조안전성 평가에 관한 사례 연구)

  • 은충기;채원규;손영현
    • Proceedings of the Korean Institute of Industrial Safety Conference
    • /
    • 1998.11a
    • /
    • pp.147-152
    • /
    • 1998
  • In this thesis, the structural safety evaluation of a building with adversiting pillar tower were studied. From the structural analysis results of a building with adversiting pillar tower, the bending stress, the shearing stress and the axial stress were calculated, and these member forces were applied to the structural safety evaluation of a building with adversiting pillar tower.

  • PDF

A Design of 150 meters high steal tower (150m 철탑의 설계 I)

  • 이재숙
    • 전기의세계
    • /
    • v.17 no.3
    • /
    • pp.43-56
    • /
    • 1968
  • The design of this antenna tower on the publication had been prepared by writer in order to compare with that of towers for power transmission line or to show the differences on designs existing on their design standards. The design of this antenna tower is also featuring on the following points; (1) the height of tower is 150meters high, (2) combined steel angles are adopted besides angles, (3) the direction of 45degree wind is taken account into design, (4) the additional stresses of horizontal members located in the bending points of main posts are contemplated though these additional stressess are not shown on stress diagram.

  • PDF

Cooling fluid dynamic simulation and measuring of HVDC Valve module and tower (HVDC Valve module 및 tower의 냉각수 유동 해석 및 측정에 관한 연구)

  • Jung, Teagsun;Lee, Jinhee;Baek, Seungtaek
    • Proceedings of the KIPE Conference
    • /
    • 2014.11a
    • /
    • pp.161-162
    • /
    • 2014
  • 본 연구의 목적은 HVDC Valve module 및 valve tower에 유입되는 냉각 유체의 유동장 동적 해석과 동시에 냉각 유체의 동적 특성을 측정 비교함으로써 유동 해석의 적합성을 판단하고, HVDC valve module과 valve tower의 냉각 유로 및 관련 기구 설계의 기초 자료로 활용하는데 그 목적이 있다.

  • PDF

흡수탑에서 VOCs 제거 기술개발을 위한 세정수의 특성연구

  • 김혜진;최상기;박문기;박상원;최성우
    • Proceedings of the Korean Environmental Sciences Society Conference
    • /
    • 2001.11a
    • /
    • pp.44-45
    • /
    • 2001
  • VOCs의 일종인 benzene을 흡수하기 위한 최적의 세정액으로 열매체유를 선정하여, 충진탑(Packed Tower), 흡수칼럼에 세정액만 채워 bubble 시킨 기포탑(Aeration Tower)와 충진물과 세정액을 채워 bubble 시킨 Combined Packed & Aeration Tower의 3가지 시스템을 비교한 결과 Combined Packed 쇼 Aeration Tower 시스템에서 benzene 흡수효율이 가장 좋았다.

  • PDF

A Study on GPS Application for Tower Crane (타워크레인에 대한 GPS적용 방안 연구)

  • Park, Chang-Wook;Yun, Seok-Heon
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2008.05a
    • /
    • pp.165-169
    • /
    • 2008
  • In other side the recent construction industry is a skyscraper, a large scale and a sophistication, a construct site have many problems that an aging of worker and shortage of work force. The purpose of this study was to develop the location of tower crane and the simulation technology of tover crane. The automation of tower carne is a important component in skyscrapers. Specially, this study suggested that it was to develop the exact location system through GPS(Global Positioning System) better than former times.