• Title/Summary/Keyword: total torque

Search Result 324, Processing Time 0.023 seconds

Effect on Improvement of Muscle Strength for Loading Pattern using Electric Exercise Instrument (전동식 운동기기의 부하방식에 따른 근력증진 효과)

  • Kang, Seung-Rok;Kim, Kyung;Jeong, Gu-Young;Seo, Young-Bum;Jeong, Jang-Sik;Kim, Jung-Ja;Kwon, Tae-Kyu
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.29 no.2
    • /
    • pp.229-238
    • /
    • 2012
  • This study is to compare muscle strength between isotonic exercise and isotonic & isokinetic exercise. Participants are 12-man and 10-woman whom they are healthy without medical history in shoulder, elbow and lumbar joint. We performed experiment total 4-weeks that exercise 3-days a week each exercise pattern. We measured shoulder, elbow and lumbar joint torque with BIODEX and circumference of muscle in upper arms once a week. The result showed that isotonic & isokinetic exercise pattern significantly more improved joint torque in shoulder, elbow, lumbar than isotonic exercise pattern. Because that isotonic & isokinetic exercise pattern supplied muscle strengthen and caused muscle contraction. This exercise pattern can be used new exercise training method for major athlete and normal people. Also this pattern can be used rehabilitation treatment.

An improvement of cycloconverter output using phase shifting filter (상천이 필터를 이용한 싸이클로컨버터 출력의 개선)

  • Kim, Jong-Su;Seo, Dong-Hoan;Kim, Jeong-Woo;Kim, Sung-Hwan
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.37 no.1
    • /
    • pp.121-126
    • /
    • 2013
  • Cycloconverter used as a power conversion device in the speed and torque control system of AC machines has the advantage of a simple control and a large torque at low speed. In addition, because a rectifier, a DC link, and an inverter are not installed, this system is simple and suitable for large power system. If a power conversion device, which is currently used as a propulsion motor of large vessel, is changed into cycloconverter, the system is simplified and then the installation costs can be significantly reduced. However, conventional cycloconverter has the increased harmonics because the power loss is large and the waveform of output voltage is distorted, due to the high-speed switching of power semiconductor devices. In order to improve these shortcomings, this paper describes a phase shifting filter which is composed of two inputs with different phases in the primary side and one output in the secondary one. As the voltage waveforms with two different phases are added and transformed into the secondary side, these outputs are close to sinusoidal waves. Thereby the voltage waveforms, which are applied to the propulsion motors, are improved and total harmonic distortions (THDs) are significantly reduced.

Factor Affecting Mandibular Rotational Troque Movements (하악의 비틀림회전운동에 영향을 미치는 요인)

  • 이유미;한경수;허문일
    • Journal of Oral Medicine and Pain
    • /
    • v.23 no.2
    • /
    • pp.143-155
    • /
    • 1998
  • This study was performed to investigate the factor that might affect mandibualr body rotation. For the study, 115 patients with temporomandibular disorders and 35 dental students without angy signs and symptoms of temporomandibular disorders were randomly selected as the patient group and the contreol group, respectively. Preferred chewing side, Angle' classification, lateral guidance pattern, and affected side were clinically recorded, and the amount of Mandibular body rotational torque movement was measured in wide opening and closure, in right and left excursion with vertical and lateral distance in frontal plane, right and left rotational angel in horizontal and in frontal plane. Masticatory muscle activity of anteriorocclusal contact pattern on maximal hard biting were also observed synchronously with BioEMG and T-Scan , respectively. The observed items were muscle activity of anterior temporalis and superficial masseter, and tooth contact status related to contact number, force, duration, and occlusal unbalance between right and left arch. The data collected were analyzed by SAS statistical program. The results of this study were as follows : 1. Mean value of vertical distance in frontal plane in wide opening and closure was more in control subjects than in patients, but there was no difference for rotational angle. In right excursion, rotational angles were greater in patient group than in control group. 2. Comparison among the subjects by preferred chewing side did not reveal any significant difference, but comparison among patients by affected side showed more rotational amount in bilaterally affected patients than in unilaterally affected patients. 3. Comparison among the subjects by Angle's classification or lateral guidance pattern revealed no difference. There was also no difference between preferred chewing side and contralateral side, and between affected side and contralateral side. 4. Positive correlation in madibular rotational torque movements were observed among vertical distance, total horizontal rotation angle, electromyographic activity of anterior temporalis, tooth contact number, and tooth contact force but total frontal rotation angle almost did not show any correlation with other variables except vertical distance.

  • PDF

Harmonic Reduction of Electric Propulsion Ship by Multipulse Drive (다중펄스 드라이브에 의한 전기추진선박의 고조파 저감)

  • Kim, Jong-Su
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.15 no.2
    • /
    • pp.425-431
    • /
    • 2011
  • The harmonic distortion level may be significant in electric propulsion systems, as the main loads usually are variable speed propulsion/thruster drives. Distortion of currents and supply voltage waveforms may lead to: Increased power dissipation(losses) in equipment connected to the network, such as generators, motors, transformers, cables, etc., from the harmonic currents, may cause overheating and deterioration of the insulation, and reduced life time of the equipment. In this paper introduced the canceling method of harmonic currents by a multipulse drive with phase shifting transformer. The simulation results indicated a good speed response to the middle speed range of electric propulsion motor. And also, THD(total harmonic distortion) and torque ripple could be reduced in comparing the 12-pulse drive with 6-pulse drive.

A Coordination Control Methodlolgy for Two Cooperating Arms Handling a Single Object (단일물체 조작을 위한 두 협조 로봇의 협조제어)

  • Yeo, Hee-Joo
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.6 no.2
    • /
    • pp.190-196
    • /
    • 2000
  • A hybrid position/force control scheme to regulate the force and position by dual arms is proposed where two arms are treated as one rm in a kinematic viewpoint. The force error calculated from the information of two force/torque sensors attached to the end of each arm is transferred to minimum configuration space coordinates and then is distributed to total system joint coordinates, The position adjustment at the total con-figuration coordinates is computed based on the effective compliance matrix with respect to total joint coordinates which is obtained by coordinate transformation between the task coordinates and the total joint coordinates. The proposed scheme is applied to sawing task. When the trajectory of the saw is planned to follow a line in a horizontal plane 2 position parameters are to be controlled(i.e., two translational positions) Also a certain level of contact force has to be controlled along the vertical direction(i.e. minus z-direction) not to loose the contact with the object to be sawn. We experimentally show that the performance of the velocity and force response are satisfactory. The proposed hybrid control scheme can be applied to arbitrary two cooperating arm system regardless of their kinematic structure and the number of actuated joints.

  • PDF

Simulation of High Pressure Common-rail Fuel Injection System (커먼레일 고압분사 시스템 수치 시뮬레이션)

  • 김홍열;구자예;나형규;김창수
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.6 no.5
    • /
    • pp.162-173
    • /
    • 1998
  • The high pressure common rail injection system offers a high potential for improving emmisions and performance characteristics in large direct diesel engines. High pressures in the common rail with electronic control allows the fuel quantity and injection timing to be optimized and controlled throughout a wide range of engine rpm and load conditions. In this study, high pressure supply pump, common rail, pipes, solenoid and control chamber, and nozzle were modeled in order to predict needle lift, rate of injection, and total injected fuel quantity. When the common rail pressure is raised up to 13.0 ㎫ and the targer injection duration is 1.0ms, the pressure drop in common rail is about 5.0㎫. The angle of effective pressurization is necessary to be optimized for the minimum pump drive torque and high pressure in common rail depending on the operating conditions. The characteristics of injection were also greatly influenced by the pressures in common rail, the areas of the inlet and exit orifice of the control chamber.

  • PDF

The Effect of Lower Leg Taping on the Muscle Performances of Ankle Joint (하퇴부 보조테이핑이 족관절의 근기능에 미치는 효과)

  • Choi, Kyu-Hwan;Kim, Hyun-Tae
    • The Journal of Korean Physical Therapy
    • /
    • v.13 no.2
    • /
    • pp.445-452
    • /
    • 2001
  • The purpose of this study to compare the muscle performances (peak torque (PT), relative strength (RS), average power (AP), and total work (TW)) between taping group and non-taping group after 1 hour extensive exercise. Twenty healthy male subjects were evaluated in this study. Each subject was divided with taping(n=10) and non-taping group (n=10) randomly. Muscle performances were measured at 60 degree/sec and 180 degree/sec on the Cybex 770. The PT, RS, AP, and TW were measured before and after 1 hour extensive exercise. The results showed that taping group demonstrated significantly higher PT, RS, AP, and TW during ankle dorsiflexion and plantar flexion at 60 degree/sec than those of non-taping group, except for total work during ankle plantar flexion. At the 180 degree/sec, PT and RS was significantly higher during ankle dorsiflexion and plantar flexion in taping group than in non-taping group. This results suggest that lower leg taping could be useful to maintain muscle performances during sport activities.

  • PDF

FPGA Implementation of Diode Clamped Multilevel Inverter for Speed Control of Induction Motor

  • Kuppuswamy, C.L.;Raghavendiran, T.A.
    • Journal of Electrical Engineering and Technology
    • /
    • v.13 no.1
    • /
    • pp.362-371
    • /
    • 2018
  • This work proposes FPGA implementation of Carrier Disposition PWM for closed loop seven level diode clamped multilevel inverter in speed control of induction motor. VLSI architecture for carrier Disposition have been introduced through which PWM signals are fed to the neutral point seven level diode clamped multilevel using which the speed of the induction motor is controlled. This proposed VLSI architecture makes the power circuit to work better with reduced stresses across the switches and a very low voltage and current total harmonic distortion (THD). The output voltages, currents, torque & speed characteristics for seven level neutral point diode clamped multilevel inverter for AC drive was studied. It has observed the proposed scheme introduces less distortion and harmonics. The results were validated using real time results.

Dynamic Changes depending on Adaptation to Assistive Joint Stiffness in Metatarsophalangeal Joint during Human Running (인체주행 시 중족지절 관절 보조 강성에의 적응에 따른 동역학적 변화 고찰)

  • Keonyoung Oh
    • Journal of Biomedical Engineering Research
    • /
    • v.45 no.2
    • /
    • pp.57-65
    • /
    • 2024
  • Recently, several studies have been conducted to lower the cost of transport of human by adding external joint stiffness elements. However, it has not been clearly elucidated whether adaptation time is required for human subjects to adapt to the added external joint stiffness. In this study, carbon plates in the form of shoe midsoles were added to the metatarsophalangeal joint, and the lower limb joint torque and mechanical energy consumption were compared before and after a total of 5 sessions (2.5 weeks) of running. A total of 11 young healthy participants exhibited higher elastic energy storage in carbon plates in the fifth session compared to the first session, and lower power in the ankle joint. This suggests that a single training session may be insufficient to validate the efficiency effect of added joint stiffness, and the human body seems to increase the elastic energy stored in the assistive joint stiffness and its reutilization.

Comparison of Isokinetic Strength between Stage 1,2 Impingement Syndrome and Rotator Cuff Tear (1, 2단계 충돌 증후군과 회전근 개 파열 환자의 등속성 근력 비교)

  • Kim, Deok-Weon;Joo, Hae-Kyun;Jung, Jae-Eun
    • Clinics in Shoulder and Elbow
    • /
    • v.13 no.1
    • /
    • pp.53-57
    • /
    • 2010
  • Purpose: The goal of this study was to evaluate differences in strength deficits between (i) patients with stage 1 or 2 impingement syndrome and (ii) patients with rotator cuff tears. Materials and Methods: We enrolled 43 patients with stage 1 or 2 impingement syndrome (group 1) and 21 patients with rotator cuff tears (group 2). The isokinetic strength of both groups was evaluated at $60^{\circ}/sec$ for external rotation, internal rotation, adduction and abduction. We measured the peak torque, total work, average power of bilateral sides, peak torque relationship to body weight, and the ratio between unilateral agonist and antagonist. Results: The isokinetic strength deficits assessed in ratio of peak torque to body weight for group 1 and group 2 respectively were; $28.48{\pm}23.76%$ and $29.12{\pm}32.81%$ for abduction (p=0.929), $7.20{\pm}13.98%$ and $18.94{\pm}19.52%$; for adduction (p=0.021), $16.88{\pm}13.76%$ and $25.80{\pm}24.07%$; for external rotation (p=0.221), and $14.1{\pm}25.67%$ and $29.02{\pm}35.06%$ for internal rotation (p=0.059). For average power and total work, group 2 showed a significantly greater deficit for adduction and internal rotation than group 1. Conclusion: Those with rotator cuff tears have more isokinetic muscle strength deficits than those with stage 1 or 2 impingement syndrome. Progression from stage 1 and 2 impingement syndrome to stage 3 may result in greatest changes in strength deficits for internal rotation and adduction.