INAA.ICP.AAS를 이용한 대기먼지 $(PM_{10})$의 다원소분석 (Multielement Analysis in Airborne Particulate Matter $(PM_{10})$ by INAA, ICP and AAS)

  • 정용삼;문종화;정영주;박광원;이길용;윤윤열;심상권;조경행;한명섭
    • 한국대기환경학회지
    • /
    • 제15권4호
    • /
    • pp.495-503
    • /
    • 1999
  • Airborne particulate matter $(PM_{10})$ collected using high volume air sampler and silica fiber filter were analyzed by Instrumental Neutron Activation Analysis(INAA), Inductively Coupled Plasma Atomic Emission Spectrometry(ICP-AES) and Atomic Absorption Spectrometry(AAS), and the results were compared with each other. 30~40 trace elements in environmental standard reference materials(NIST SRM 1648 and NIES CRM No.8) were analyzed for the analytical quality control. The relative error for two-third of elements detected was less than 10%, and the standard deviation was less than 15%. During the sampling period for 24 hours, the mass concentration of total suspended particulate was 36.1$\mu\textrm{g}$/㎥ and the value is lower than the critical level in Korea. In the results of NAA, the elements of Al, As, Ba, Fe, La, Mg, Na, Sb, Zn were well agreed with those of other methods. In statistical estimation between different methods, the deviation of Al, Ba, Cr, Fe was less than 10% and quite reliable.

  • PDF

서울지역의 시정 장애 요인에 관한 연구 (On the Origin of Visibility Degradation in Seoul)

  • 윤순창;이강웅
    • 한국대기환경학회지
    • /
    • 제14권3호
    • /
    • pp.229-236
    • /
    • 1998
  • Visibility is a good indicator of comprehensive alto quality. The prevailing visibility in Seoul is no better than the past although the average concentration of SO2 and TSP (total suspended particulate) has decreased quite significantly in the past decade, owing to the government efforts to reduce the emission. Then, a question arises why visibility has not been improved. In order to answer this question we have investigated which components of air pollutants are most responsible for the visibility degradation in Seoul. Analysis on the visibility vs the aerosol sixte distribution measured by an optical particle counter shows that the particles of the size interval between 0.5mm and 2.5mm are most responsible for the visibility degradation. Among the criteria air Pollutants, NOB concentration is found to be moot responsible, rather than PM10. ton analysis of the particulate collected by a high volume sampler shows that the nitrate component increases more significantly than other ions when visibility becomes very poor. Therefore, we conclude that the major causes of visibility degradation in Seoul are the increase of NOB, nitrates and the particles of the size range between 0.5mm and 2.5mm.

  • PDF

Particulate-Matter Related Respiratory Diseases

  • Kyung, Sun Young;Jeong, Sung Hwan
    • Tuberculosis and Respiratory Diseases
    • /
    • 제83권2호
    • /
    • pp.116-121
    • /
    • 2020
  • Particulate matter (PM) is suspended dust that has a diameter of <10 ㎛ and can be inhaled by humans and deposited in the lungs, particularly the alveoli. Recent studies have shown that PM has an adverse effect on respiratory diseases. The aim of this article is to review respiratory diseases associated with PM. According to existing studies, PM is associated with chronic obstructive pulmonary disease, bronchial asthma, and several other respiratory diseases and increases the mortality rates of these diseases. Moreover, increased exposure in the high concentration of atmospheric PM is associated with the development of lung cancer. The most simple and common way to protect an individual from airborne PM is to wear a face mask that filters out PM. In areas of high concentration PM, it is recommended to wear a face mask to minimize the exposure to PM. However, the use of N95 or KF94 masks can interfere with respiration in patients with chronic respiratory diseases who exhibit low pulmonary function, leading to an increased risk of respiratory failure. Conclusionally, reduction of the total amount of PM is considered to be important factor and strengthening the national warning notification system to vulnerable patients and proper early management of exacerbated patients will be needed in the future.

Seasonal impact to air qualities in industrial areas of the Arabian Gulf region

  • Al-Taani, Ahmed A.;Howari, Fares M.;Nazzal, Yousef;Yousef, Ahmad
    • Environmental Engineering Research
    • /
    • 제23권2호
    • /
    • pp.143-149
    • /
    • 2018
  • Air quality conditions and pollution status have been evaluated in the industrial area between Sharjah and Ajman border in UAE. Daily concentrations of $O_3$, CO, $NO_2$, $SO_2$, $PM_{2.5}$, $PM_{10}$, Total Volatile Organic Compounds (TVOC) and Total Suspended Particulate (TSP) have been monitored from Sept. 2015 to April 2016. The monthly average concentrations of $O_3$, CO, $NO_2$, $SO_2$, TVOC were within the UAE ambient air quality standards during the survey period. However, $PM_{10}$ and TSP levels exceeded the recommended limits in Sept. 2015, Oct. 2015 and March 2016. Temporal variations in air quality parameters showed highest levels in March 2016 for $PM_{2.5}$, $PM_{10}$, $NO_2$, TVOC and TSP, whereas $O_3$, $SO_2$ and CO showed relatively low values in this month. $PM_{2.5}$ levels in ambient air were above the EPA guideline of $35{\mu}g/m^3$ in all months. $PM_{2.5}$ was the critical ambient air pollutant with Index for Pollutant ($I_p$) values varying from 103-209, indicating Air Quality Index categories of unhealthy for sensitive groups (62.5%) to unhealthy (25%) to very unhealthy (12.5%). The $I_p$ average values of $PM_{2.5}$ decreased from Sept. 2015 to reach lowest value in Dec. 2015 before increasing gradually, peaking in March 2016. These results suggest the potential health risks associated with $PM_{2.5}$ is low in winter, where the prevailing meteorological conditions of lower temperatures, higher humidity, higher wind speed reduced particulate matter. The results revealed the industrial area is impacted by anthropogenic and natural sources of particulate matter.

고형연료제품 사용시설에서 배출되는 미세먼지 입경분율 분석 (Analysis of the Fine Particulate Matter Particle Size Fraction Emitted from Facilities Using Solid Refuse Fuel)

  • 유한조;정연훈;김진길;신형순;임윤정;이상수;손해준;임삼화;김종수
    • 한국환경보건학회지
    • /
    • 제46권6호
    • /
    • pp.719-725
    • /
    • 2020
  • Objectives: With the growth of national interest in fine particulate matter, many complaints about pollutants emitted from air pollution emitting facilities have arisen in recent years. In particular, it is thought that a large volume of particulate pollutants are discharged from workplaces that use Solid Refuse Fuel (SRF). Therefore, particulate contaminants generated from SRF were measured and analyzed in this study in terms of respective particle sizes. Methods: In this study, particulate matter in exhaust gas was measured by applying US EPA method 201a using a cyclone. This method measures Filterable Particulate Matter (FPM), and does not consider the Condensable Particulate Matter (CPM) that forms particles in the atmosphere after being discharged as a gas in the exhaust gas. Results: The mass concentration of Total Suspended Particles (TSP) in the four SRF-using facilities was 1.16 to 11.21 mg/Sm3, indicating a very large concentration deviation of about 10 times. When the fuel input method was the continuous injection type, particulate matter larger than 10 ㎛ diameter showed the highest particle size fraction, followed by particulate matter smaller than 10 ㎛ and larger than 2.5 ㎛, and particulate matter of 2.5 ㎛ or less. Contrary to the continuous injection type, the batch injection type had the smallest particle size fraction of particulate matter larger than 10 ㎛. The overall particulate matter decreased as the operating load factor decreased from 100% to 60% at the batch input type D plant. In addition, as incomplete combustion significantly decreased, the particle size fraction also changed significantly. Both TSP and heavy metals (six items) satisfied the emissions standards. The measured value of the emission factor was 38-99% smaller than the existing emissions factor. Conclusions: In the batch injection facility, the particulate matter decreased as the operating load factor decreased, as did the particle size fraction of the particulate matter. These results will help the selection of effective methods such as reducing the operating load factor instead of adjusting the operating time during emergency reduction measures.

Deposition Process of Sulfate and Elemental Carbon in Japanese and Thai Forests

  • Sase, Hiroyuki;Matsuda, Kazuhide;Visaratana, Thiti;Garivait, Hathairatana;Yamashita, Naoyuki;Kietvuttinon, Bopit;Hongthong, Bundit;Luangjame, Jesada;Khummongkol, Pojanie;Shindo, Junko;Endo, Tomomi;Sato, Keiichi;Uchiyama, Shigeki;Miyazawa, Masamitsu;Nakata, Makoto;Lenggoro, I. Wuled
    • Asian Journal of Atmospheric Environment
    • /
    • 제6권4호
    • /
    • pp.246-258
    • /
    • 2012
  • Particulate matter deposited on leaf surfaces may cause erosion/abrasion of epicuticular wax and the malfunction of stomata. However, the deposition processes of particulate matter, such as elemental carbon (EC), has not been studied sufficiently in Asian forest ecosystems. Deposition processes for particulate ${SO_4}^{2-}$ and EC were studied in a Japanese cedar forest in Kajikawa, Niigata Prefecture, Japan, and in a dry evergreen forest and a dry deciduous forest in Sakaerat, Nakhon Ratchasima province, Thailand. The ${SO_4}^{2-}$ fluxes attributed to rainfall outside the forest canopy (RF), throughfall (TF), and stemflow (SF) showed distinct seasonalities at both sites, increasing from November to February at the Kajikawa site and in March/April at the Sakaerat site. Seasonal west/northwest winds in winter may transport sulfur compounds across the Sea of Japan to the Kajikawa site. At the Sakaerat site, pollutants suspended in the air or dry deposits from the dry season might have been washed away by the first precipitations of the wet season. The EC fluxes from RF and TF showed similar variations by season at the Kajikawa site, while the flux from TF was frequently lower than that from RF at the Sakaerat site. Particulate matter strongly adsorbed onto leaf surfaces is not washed away by rainfall and contributes to the EC flux. At the Kajikawa site, Japanese cedar leaf surfaces accumulated the highest levels of particulate matter and could not be neglected when calculating the total flux. When such leaf-surface particles were considered, the contribution of dry deposition to the total EC flux was estimated to be 67%, 77%, and 82% at the Kajikawa site, and at the evergreen and deciduous forests of the Sakaerat site, respectively. Leaf-surface particles must be included when evaluating the dry and total fluxes of particulate matter, in particular for water-insoluble constituents such as EC.

주성분/중회귀분석을 이용한 대구지역 대기중 부유분진의 발생원별 특성평가 (Source Characterization of Suspended Particulate Matter in Taegu Area, Using Principal Component Analysis Coupled with Multiple Regression)

  • 백성옥;황승만
    • 한국대기환경학회지
    • /
    • 제8권3호
    • /
    • pp.179-190
    • /
    • 1992
  • This study was carried out to characterize sources of atmospheric total suspended particulates (TSP) in urban and sub--urban areas of metropolitan taegu. The sources were tentatively identified by a multivariate technique, i.e. principal component analysis (PCA), and the source contributions to the atmospheric concentrations of TSP were further estimated by stepwise multiple regression analysis. A total of 5 sources was identified in the urban area of Taegu (soil dust resuspension, fuel combustion, secondary aerosol, traffic related aerosol, and refuge burning), while 4 sources were found to be significant in the sub--urban area as following: fuel combustion/secondary aerosol, soil dust resuspension, traffic related aerosol, and wood/agricultural burning. The largest contributor to the atmospheric TSP appeared to be the soil dust resuspension in both areas. The source apportionment of the extractable organic matter (EOM) was also carried out for the Taegu data. The EOM was determined with respect to the solvent polarity, i.e. cyclohexane (non-polar), dichloromethane (semi--polar), and acetone (polar). In addition, the source profiles for the TSP in Taegu area were estimated using a PCA-based algorithm, and the validity was evaluated tentatively by comparing the data in the literature.

  • PDF

도시 대기 부유분진 중 음이온의 농도 (Concentrations of Anions in Airbone Particulate Matters in Metropolitan Area)

  • 손동헌;신경순
    • 약학회지
    • /
    • 제34권3호
    • /
    • pp.206-211
    • /
    • 1990
  • Total suspended particles were collected and size-fractionated by an Andersen high-volume air sampler at Chungang University located near the Han River, Seoul, Korea, during the period form March, 1986 to August, 1986 and from March, 1987 to February, 1988. The concentrations and the particle size distributions of anions such as chloride, nitrate and sulfate were determined by ion chromatography. The averages of concentrations were $125.43\;{\mu}g/m^3$ in 1986 and $189.19\;{\mu}g/m^3$ in 1987 for total suspended particles (TSP), $2.12\;{\mu}g/m^3$ in 1986 and $4.14\;{\mu}g/m^3$ in 1987 for chloride, $4.39\;{\mu}g/m^3$ in 1986 and $5.95\;{\mu}g/m^3$ in 1987 for nitrate and $11.98\;{\mu}g/m^3$ in 1986 and $19.29\;{\mu}g/m^3$ in 1987 for sulfate. Size distribution of TSP was found to be generally bimodal. Chloride exhibited a seasonal variation in the distribution; fine particles were predominant in the winter whereas the concentration of coarse ones was almost same through four seasons. Nitrate showed a distribution similar to that of chloride. Such variation was less significant for sulfate. For chloride and nitrate, the relationship between the monthly averaged distribution pattern and air temperature was analyzed in terms of fine fraction (FF). The FF decreased with increasing air temperature.

  • PDF

서울지역 일부 대기중 부유먼지에 함유된 탄소 성분과 Benzo(a)pyrene 성분의 농도변동 양상에 관한 연구 (A Study on the Variation of the Concentrations of Carbon Species and B(a)P Associated in Atmospheric Suspended Particles in an Urban Area of Seoul)

  • 황경철;김희강
    • 한국환경보건학회지
    • /
    • 제23권4호
    • /
    • pp.91-96
    • /
    • 1997
  • In order to investigate the behavior of particulate carbon and benzo(a)pyrene(B(a)P) in the ambient air, suspended particle matters were collected from April, 1990 to February, 1992, and total carbon(TC), organic carbon(OC), elemental carbon(EC) and B(a)P were measured by an elemental analyzer and a HPLC. The results were as follows the average concentration of TC was 38.6 $\mug/m^3$ and its concentration was higher in winter(45.4 $\mug/m^3$) and fa11(44.3 $\mug/m^3$) than in summer(36.8 $\mug/m^3$) and spring(28.9 $\mug/m^3$). The monthly concentration trends both of EC and OC was similar, but seasonal variation of EC concentrations was larger than that of OC. The average concentration of B (a)P was 2.2 ng/m$^3$, and was higher in winter(4.1 ng/m$^3$) and fall(3.2 ng/m$^3$) than in spring(1.2 ng/m$^3$) and summer(0.6 ng/m$^3$). The seasonal behavior of carbon and B(a)P was to similar except for summer. The correlation coefficient(r) between EC and B(a)P was 0.71, and the correlation coefficient(r) between OC and B(a)P was 0.66.

  • PDF

Pretreatment Process for Performance Improvement of SIES at Kori Unit 2 in Korea

  • Lee, Sang-Jin;Yang, Ho-Yeon;Shin, Sang-Woon;Song, Myung-Jae
    • 한국방사성폐기물학회:학술대회논문집
    • /
    • 한국방사성폐기물학회 2004년도 Proceedings of the 4th Korea-China Joint Workshop on Nuclear Waste Management
    • /
    • pp.12-27
    • /
    • 2004
  • Pretreatment process consisted of submerged hollow-fiber microfiltration(HMF) membrane and spiral-wound nanofiltration(SNF) membrane has been developed by NETEC, KHNP for the purpose of improving the impurities of liquid radioactive waste before entering Selective Ion Exchange System(SIES). The lab-scale combined system was installed at Kori NPP #2 nuclear power plant and demonstration tests using actual liquid radioactive waste were carried out to verify the performance of the combined system. The submerged HMF membrane was adopted for removal of suspended solid in liquid radioactive waste and the SNF membrane was used for removal of particulate radioisotope such as, Ag-l10m and oily waste because ion exchange resin can not remove particulate radioisotopes. The liquid waste in Waste Holdup Tank (WHT) was processed with HMF and SNF membrane, and SIES. The initial SS concentration and total activity of actual waste were 38,000ppb and $1.534{\times}10_{-3}{\mu}Ci/cc$, respectively. The SS concentration and total activity of permeate were 30ppb and lower than LLD(Lower Limit of Detection), respectively.

  • PDF