• Title/Summary/Keyword: total stability

Search Result 2,125, Processing Time 0.031 seconds

Assessment of Total Transfer Capability Using IPLAN: An Application of UPFC for Total Transfer Capability Enhancement

  • Lee Byung Ha;Kim Jung-Hoon;Kwak No-Hong;Lee Woon-Hee
    • KIEE International Transactions on Power Engineering
    • /
    • v.5A no.3
    • /
    • pp.244-251
    • /
    • 2005
  • Power transfer capability has been recently highlighted as a key issue in many utilities. It is determined by the thermal stability, dynamic stability and voltage stability limits of generation and transmission systems. In particular, voltage stability affects power transfer capability to a great extent in many power systems. This paper presents a tool for determining total transfer capability from a static voltage stability viewpoint using IPLAN, which is a high level language used with the PSS/E program. The tool was developed so as to analyze static voltage stability and to determine the total transfer capability between different areas from a static voltage stability viewpoint by tracing stationary behaviors of power systems. A unified power flow controller (UPFC) is applied for enhancing total transfer capability between different areas from the viewpoint of static voltage stability. Evaluation of the total transfer capability of a practical KEPCO power system is performed from the point of view of static voltage stability, and the effect of enhancing the total transfer capability by UPFC is analyzed.

A Study on Location of STATCOM for Improvement of Total Transfer Capability and Analysis of Total Transfer Capability Considering Transient Stability (전체송전용량 향상을 위한 STATCOM 설비의 적용 위치 선정 및 과도안정도를 고려한 전체송전용량 분석)

  • Lee, Byung-Ha;Baek, Jung-Myoung
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.24 no.4
    • /
    • pp.17-24
    • /
    • 2010
  • The power transfer capability has been recently highlighted as a key issue in many utilities with the power system more stressed and heavy loaded. The total transfer capability in the KEPCO power system is determined mainly by the voltage stability limit and many approaches for enhancement of the total transfer capability has been consistently performed. In this paper, a new transfer capability index to locate the STATCOM(Static Synchronous Compensator) effectively for enhancing the total transfer capability from a static voltage stability viewpoint is presented and it is applied to a small scale power system of IEEE 39-bus test system in order to show the effects of this index. In addition, the effect of transient stability as well as voltage stability to the total transfer capability when loads are increased is analyzed using this small scale power system.

The Homogeneity and Short-term Stability Test of Bio-matrix Reference Material for Total Mercury Analysis of Freshwater Fish (담수 어류 총수은 분석용 생물 표준물질 균질성, 안정성 시험평가)

  • Lee, Soo Yong;Lee, Jangho;Chung, David;Shim, Kyu-Young;Lee, Ha-Eun;Park, Ki-Wan
    • Journal of Environmental Science International
    • /
    • v.28 no.11
    • /
    • pp.1033-1040
    • /
    • 2019
  • The National Environmental Specimen Bank (NESB) has set up a plan to develop reference materials in the facility for assuring analytical quality and validating analytical methods for its monitoring samples. Some of the crucial characteristics that reference materials must consist of are homogeneity and stability of both intra and inter-bottles. In this study, we examined the homogeneity and stability of cryogenically-milled muscle samples, from Common Carp (Cyprinus carpio) for total mercury. Homogeneity was tested using ANOVA analysis and regression analysis was used to test short-term stability. The variations of total mercury concentration did not significantly differ between the intra and the inter-bottle (F=0.8, p=0.37). Additionally, relative standard deviation of the total mercury concentration showed low values (2.28%). For the short-term stability test, total mercury variations were not statistically significant as demonstrated by the result of the regression analysis (F ratio = 3.11, p = 0.18). This suggests that the cryogenic-milling process has statistically proven the degree of homogeneity and short-term stability for samples of carp muscles in the chemical analysis for total mercury.

A Note on Total Stability

  • Gu, Yoon-Hoe;Ryu, Hyun Sook
    • Journal of the Chungcheong Mathematical Society
    • /
    • v.3 no.1
    • /
    • pp.83-88
    • /
    • 1990
  • It is well-known that under suitable conditions, uniform asymptotic stability implies total stability. We prove this theorem of Malkin by using Liapunov-like functions and so our proof is a detailed version of Yoshizawa's proof.

  • PDF

Evaluation of Biomechanical Stability of Newly Developed Revision Total Knee Arthroplasty through Strain and Stress Distribution Analysis within the Tibia: Finite Element Analysis (경골 내 변형률 및 응력 분포 특성 분석을 통한 새로이 개발된 재치환용 인공슬관절의 생체역학적 안정성 평가: 유한요소해석)

  • Han, Paul;Jang, Young-Woong;Yoo, Oui Sik;Kim, Jung Sung;Kim, Han Sung;Lim, Dohyung
    • Journal of Biomedical Engineering Research
    • /
    • v.34 no.1
    • /
    • pp.14-23
    • /
    • 2013
  • In this study, biomechanical stability of the newly developed revision total knee arthroplasty (rTKA) was evaluated through strain and stress distribution analysis within the implanted proximal tibia using a three-dimensional finite element (FE) analysis. 2000N of compressive load (about 3 times body weight) was applied to the condyle surface on spacer, sharing by the medial (60%) and lateral (40%) condyles simulating a stance phase before toe-off. The results showed that PVMS within the revision total knee arthroplasty and the proximal tibia were less than yield strength considering safe factor 4.0 (rTKA: less than 10%, Cortical bone: less than 70%, Cancellous bone: less than 70%). The materials composed of them and the strain and stress distributions within the proximal tibia were generally well matched with those of a traditional revision total knee arthoplasty (Scorpio TS revision system, Stryker Corp., Michigan, USA) without the critical damage strain and stress, which may reduce the capacity for bone remodeling, leading to bone degeneration. This study may be useful to design parameter improvement of the revision total knee arthoplasty in biomechanical stability point of view beyond structural stability of revision total knee arthoplasty itself.

Financial Status of Elderly Households -to make a Financial Plan for Retirement Preparation- (재무계획 수립을 위한 노인가계의 재정상태 분석)

  • 김순미
    • Journal of the Korean Home Economics Association
    • /
    • v.36 no.10
    • /
    • pp.179-196
    • /
    • 1998
  • The purpose of this study was to analyze the financial status of Korean elderly households to make a financial plan for retirement preparation. The sample obtained from 1997 KHPS, consisted of 326 households of 55-64 aged and 210 households of 65 and over aged. Statistics employed for the analysis were frequencies, percentile, univariate analysis and logistic analysis. And Lorenz curve and Gini coefficient were used to compare the financial status. The results could be summarized as follows. First, total income, total expenditure, total debt and net worth of 55-64 aged group were higher than those of 65 and over group, while total asset of 55-64 aged group was similar to 65 and over group's Second, total expediture to total imcome ratio(R1) and total asset to total debt ratio(R4) of 55-64 aged group were higher than 65 and over group's, but net worth to minimum cost of living ratio(R2) and financial asset to monthly expenditure ratio(R3) of 65 and over group were higher than 55-64 aged group's . Third, R4's Gini coefficient was the highest and R1's Gini coefficient was the lowest among all Gini coefficients. Also, R1's and R4's Gini coefficients of 55-64 aged group were greater than 65 and over group's. ourth, variables affecting R1's stability of 55-64 aged group were household head's age, educatonal attainment and family type, while those of 65 and over group were household head's age, past economic experience and the number of children. There was no significant variable affecting R2's stability of 55-64 aged group, but there was only household head's pst economic experience affecting those of 65 and over group. The variable contributing to R3's stability of 55-64 aged group was residence while the variables of 65 and over group were household head's educational attainment, past economic experience and the number of children. The variables contributing to R4's stability of 55-64 aged group were the number of children and residence, and the number of children was one variable of contributing to R4's stability of 65 and over aged group.

  • PDF

Contingency Ranking for Determining Total Transfer Capability from Voltage Stability Point of View (전체송전용량 결정을 위한 전압안정도 측면에서의 상정사고 순위 매김)

  • Lee, Byung-Ha;Baek, Jung-Myoung
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.22 no.2
    • /
    • pp.148-154
    • /
    • 2008
  • The power transfer capability has been recently highlighted as a key issue in many utilities. The total transfer capability in the KEPCO power system is determined mainly by the voltage stability limit and an enormous number of contingencies should be analyzed to determine the total transfer capability. In this paper, a new ranking index for determining the total transfer capability from voltage stability point of view is presented. This index is applied to the practical system of KEPCO and the effects of ranking the contingencies are analyzed by use of PSS/E package and a developed IPLAN program.

Assessment of Total Transfer Capability Considering Transient Stability (과도 안정도를 고려한 총 송전용량 평가)

  • Park, Jin-Wook;Bae, In-Su;Kim, Jin-O;Kim, Kyu-Ho
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.19 no.7
    • /
    • pp.94-99
    • /
    • 2005
  • This paper presents a method to assess total transfer capability(TTC) considering transient stability. TTC is limited not only by the violation of system voltage and thermal limits, but also restricted by transient stability limit, TTC calculation is divided into two processes. The frist step is to calculate TTC without considering the transient stability constraint by using repeated power flow(RPF) method. The second step is to perform transient stability analysis based on TTC calculation in the frist step.

Analysis of the Dynamic Balance Recovery Ability by External Perturbation in the Elderly

  • Park, Da Won;Koh, Kyung;Park, Yang Sun;Shim, Jae Kun
    • Korean Journal of Applied Biomechanics
    • /
    • v.27 no.3
    • /
    • pp.205-210
    • /
    • 2017
  • Objective: The aim of the study was to investigate the age-related ability of dynamic balance recovery through perturbation response during standing. Method: Six older and 6 younger adults participated in this study. External perturbation during standing as pulling force applied at the pelvic level in the anterior direction was provided to the subject. The margin of stability was quantified as a measure of postural stability or dynamic balance recovery, and using principal component analysis (PCA), the regularity of the margin of stability (MoS) was calculated. Results: Our results showed that in the older adult group, 60.99% and 28.63% of the total variance were captured using the first and second principal components (PCs), respectively, and in the younger adult group, 81.95% and 10.71% of the total variance were captured using the first and second PCs, respectively. Conclusion: Ninety percent of the total variance captured using the first two PCs indicates that the older adults had decreased regularity of the MoS than the younger adults. Thus, the results of the present study suggest that aging is associated with non-regularity of dynamic postural stability.