• Title/Summary/Keyword: total hip joint replacement

Search Result 49, Processing Time 0.026 seconds

인공고관절 생체재료 마멸평가를 위한 시뮬레이터 개발 (Development of Hip Joint Simulator to Evaluate The Wear of Biomaterials Used in Total Hip Joint Replacement)

  • 이권용;윤재웅;전승범;박성길
    • 한국윤활학회:학술대회논문집
    • /
    • 한국윤활학회 2001년도 제33회 춘계학술대회 개최
    • /
    • pp.265-270
    • /
    • 2001
  • Hip joint simulator which Is an essential device for evaluating the wear of biomaterials (ultrahigh molecular weight polyethylene, Co-Cr alloy, alumina, etc.) used in total hip joint replacement was developed. This hip joint simulator mimics the joint motion and joint loading of human gait by adapting the 4 degree of freedom in kinematic motion (flexing/extension, adduction/abduction, Internal rotation/external rotation) and axial loading, Four stations are operated by 8 servo-motors and harmony drives. Joint leading was imposed by displacement control from a ball screw, LM guide, and spring system. Each kinematic link system operates separately or coupled modes. A heater and a thermocouple were installed for keeping the body temperature in each station.

  • PDF

유한요소법을 이용한 인공 고관절의 접촉응력 해석에 관한 연구 (A Study on the Contact Stress Analysis of the Artificial Hip Joint Using Finite Element Method)

  • 김청균;윤종덕
    • 한국윤활학회:학술대회논문집
    • /
    • 한국윤활학회 1996년도 제24회 추계학술대회
    • /
    • pp.189-194
    • /
    • 1996
  • The modern orthopaedics frequently uses the total hip replacement in the artificial hip joint. The wear in this joint requires the re-replacement of the hip joint beacuse it is under the severe load and friction conditions. To solve these problems the previous studies have been mainly focused on the development of the new materials. The research of new material, however, needs much time and effort since it should be experimented for its bio-compatibility, friction, and wear characteristics. To reduce the work, in this study, the finite element analysis is applied to find the new combination of the materials in the total hip replacement which has the excellent contact characteristics. The finite element uses MARC and the 5-node aximetric element. The results show that in case of acetabulum UHMWP has good characteristics, in femoral head, the $Al_2O_3$, and in stem, Ti6Al4V.

  • PDF

Total Hip Replacement for Treatment of Chronic Coxofemoral Joint Dislocation in 7 Dogs

  • Yoon, Jang-Won;Heo, Su-Young;Jeong, Seong-Mok;Lee, Hae-Beom
    • 한국임상수의학회지
    • /
    • 제36권4호
    • /
    • pp.229-232
    • /
    • 2019
  • Total Hip Replacement in a patient with chronic coxofemoral joint dislocation is a challenging problem because chronic coxofemoral joint dislocation causes severe morphological changes. These challenging factors make surgery more difficult and increase the possibility of postoperative complications including cup implant dislocation and prosthetic joint luxation. All patients were diagnosed having at least 2 months of coxofemoral joint dislocation. On physical examination, crepitus was noted in the coxofemoral joint. Radiographs revealed hip joint dislocation with mild to severe degenerative changes. Total hip replacement was planned for all patients. Dorsal acetabular rim deficiency in 3 cases was augmented using a locking plate and polymethylmethacrylate bone cement. All cases have shown difficulty in prosthetic joint reduction. Pectineus and rectus femoris muscle origin were released in all cases. At 12 months follow up, all patients showed satisfactory ambulation. The issues on perioperative prosthetic joint reduction and luxation due to chronic coxofemoral joint luxation with muscle contracture and dorsal acetabular rim deficiency can be resolved by muscle releasing and dorsal acetabular rim augmentation.

유한요소법을 이용한 인공 고관절의 접촉응력 해석에 관한 연구 (Contact Stress Analysis of Artificial Hip Joints Using Finite Element Method)

  • 김청균;윤종덕
    • Tribology and Lubricants
    • /
    • 제13권1호
    • /
    • pp.82-87
    • /
    • 1997
  • The modern orthopaedics frequently uses the total hip replacement in the artificial hip joint. The wear in this joint requires a re-replacement of hip joints because it is under the severe load and friction conditions. To solve these problems the previous studies have been mainly focussed on the development of new materials. The research of new materials, however, needs much time and effort since it should be experimented for its bio-compatibility, friction, and wear characteristics. To reduce the work, in this study, the finite element analysis is applied to find new combinations of bio-materials in the total hip replacement which has the excellent contact characteristics. A non-linear FEM program MARC with 5-node axisymmetric element was used for analyzing the contact stresses between the hip joints. The computed results show that in case of acetabulum UHMWP has good characteristics, in femoral head, $Al_2O_3$, and in stem, Ti6Al4V.

고관절 재치환술시 재료의 응력과 변형률의 비교 분석 (Comparative Analysis of the Stress and Strain of Material for Revision Total Hip Replacement)

  • 심동혁;김정훈;고석훈;김경훈;김대열;최명진
    • 한국정밀공학회:학술대회논문집
    • /
    • 한국정밀공학회 2006년도 춘계학술대회 논문집
    • /
    • pp.511-512
    • /
    • 2006
  • According to development of medical science and engineering, people has made efforts to solve tile discomfort of body accident as well as the life span. Many cases that reduce pain of a hip joint or limitation of motion using Revision Total Hip Replacement are getting increased. However it has not proved which material is the most appropriate. Scientists are still studying about materials of the artificial joint. In accordance with advance of science, the materials are Betting better. Recently, when Revision Total Hip Replacement is performed, typical materials are Ti-alloys Ceramics. We have studied materials of artificial joints and analyzed which one is better for human's body.

  • PDF

맞춤형 인공관절 설계를 위한 인체 고관절의 3차원 형상 정보 추출 (Extracting 3D Geometry Parameters of Hip Joint for Designing a Custom-Made Hip Implant)

  • 서정우;전용태
    • 한국CDE학회논문집
    • /
    • 제13권3호
    • /
    • pp.200-208
    • /
    • 2008
  • Total Hip Replacement(THR) is a surgical procedure that replaces a diseased hip joint with a prosthesis. A plastic or metal cup forms the socket, and the head of the femur is replaced by a metal ball on a stem placed inside the femur. Due to the various types and shapes of human hip joint of every individual, a selected commercial implant sometimes may not be the best-fit to a patient, or it cannot be applied because of its discrepancy. Hence extracting geometry parameters of hip joint is one of the most crucial processes in designing custom-made implants. This paper describes the framework of a methodology to extract the geometric parameters of the hip joint. The parameters include anatomical axis, femoral head, head offset length, femoral neck, neck shaft angle, anteversion, acetabulum, and canal flare index. The proposed system automatically recommends the size and shape of a custom-made hip implant with respect to the patient's individual anatomy from 3D models of hip structures. The proposed procedure creating these custom-made implants with some typical examples is precisely presented and discussed in this paper.

대퇴관절 전치환술을 이용하여 개의 재발되는 대퇴관절 탈구증의 치료 (Treatment of Recurrent Coxofemoral Joint Luxation by Total Hip Replacement in a Dog)

  • 김주호;허수영;김민수;이기창;김남수;이해범
    • 한국임상수의학회지
    • /
    • 제31권2호
    • /
    • pp.125-128
    • /
    • 2014
  • 38 kg, 7년령의 골든리트리버가 대퇴관절 탈구증으로 의뢰되었다. 신체검사에서는 왼쪽 뒷다리를 신전시킬 때 통증과 염발음이 확인되었다. 방사선 검사를 통해 왼쪽 대퇴관절 탈구증 및 경도의 퇴행성 골변화가 관찰되었다. 치료로서 TightRope$^{(R)}$를 이용한 최소침습 관절경적 정복을 하였으나, 수술 후 한달이 지나 재탈구가 발생하였다. 이에 대해 무시멘트형 대퇴관절 전치환술을 실시하였다. 수술 후 10개월 경과된 결과, 환자는 정상적으로 앉기, 서기, 보행을 보였으며, 특이한 파행없이 편안하게 뛸 수 있었다. 수술한 뒷다리의 허벅지둘레는 반대쪽 다리의 그것에 비해 108.6%였다. 이 증례를 통해 대퇴관절 전치환술은 대퇴관절 정복이 실패하여 재탈구된 개의 대퇴관절 탈구 치료에 효과적인 수술법이 될 수 있다.

A 3D-printing Bone Model for Surgical Planning of Total Hip Replacement after Failed Triple Pelvic Osteotomy

  • Han, Kyungjin;Park, Jiyoung;Yoon, Jangwon;Lee, Young-Won;Choi, Ho-Jung;Jeong, SeongMok;Lee, Haebeom
    • 한국임상수의학회지
    • /
    • 제34권6호
    • /
    • pp.463-466
    • /
    • 2017
  • A 3-year-old, 26 kg, castrated male Chow Chow was presented for assessment of weight-bearing lameness of the left hind limb. The patient had a history of triple pelvic osteotomy on the left side to correct hip dysplasia 2 years prior to his presentation of clinical signs and underwent total hip replacement on the right coxofemoral joint 1 year later. Upon physical examination, pain and crepitus were noted on the left hip joint during extension. Radiological examination revealed coxofemoral joint subluxation and moderate degenerative bone changes on the left hip joint and pelvic axis, which relates to acetabular angles that were changed after triple pelvic osteotomy (TPO). Preoperative computed tomography was used for 3-dimensional printing to establish an accurate surgical plan. The changed angles of the acetabulum after TPO were evaluated, and rehearsal surgery was performed using a 3-demensional printing bone model. Three months after the THR surgery, the function of the affected limb had improved, with no lameness. Complications, such as luxation and implant failure, were not observed until 6 months after the operation. Accurate evaluation of acetabulum angles and rehearsal surgery using a 3D-printed bone model is effective for total hip replacement after unsuccessful TPO.

고관절 전치환술 후 한방 재활치료에 대한 증례 보고 (A Rehabilitation for Total Hip Replacement in Korean Medicine: A Report of Three Cases)

  • 하원배;이종하;고연석;이정한
    • 한방재활의학과학회지
    • /
    • 제26권3호
    • /
    • pp.153-164
    • /
    • 2016
  • The objective of this study was to propose a rehabilitation protocol for total hip replacement in Korean medicine and to report its effectiveness. Three patients who had undergone total hip replacement were treated using the rehabilitation protocol in Korean medicine. We evaluated the outcome evaluating physical examination findings of the hip joint, numeric rating scale, pain disability index, Harris hip score, and walking state. After the treatment, we observed that hip movement and muscular strength improved. Moreover numeric rating scale, pain disability index, Harris hip score, and walking state of patients improved. A rehabilitation in Korean medicine can be effectively used for total hip replacement patients. The limitation of this study was the insufficient number of cases. Further studies are needed to design a rehabilitation protocol in Korean medicine.