• 제목/요약/키워드: total discharge

검색결과 1,198건 처리시간 0.032초

추계학적 비선형 모형을 이용한 달천의 실시간 수질예측 (Real Time Water Quality Forecasting at Dalchun Using Nonlinear Stochastic Model)

  • 연인성;조용진;김건흥
    • 상하수도학회지
    • /
    • 제19권6호
    • /
    • pp.738-748
    • /
    • 2005
  • Considering pollution source is transferred by discharge, it is very important to analyze the correlation between discharge and water quality. And temperature also influent to the water quality. In this paper, it is used water quality data that was measured DO (Dissolved Oxygen), TOC (Total Organic Carbon), TN (Total Nitrogen), TP (Total Phosphorus) at Dalchun real time monitoring stations in Namhan river. These characteristics were analyzed with the water quality of rainy and nonrainy periods. Input data of the water quality forecasting models that they were constructed by neural network and neuro-fuzzy was chosen as the reasonable data, and water quality forecasting models were applied. LMNN (Levenberg-Marquardt Neural Network), MDNN (MoDular Neural Network), and ANFIS (Adaptive Neuro-Fuzzy Inference System) models have achieved the highest overall accuracy of TOC data. LMNN and MDNN model which are applied for DO, TN, TP forecasting shows better results than ANFIS. MDNN model shows the lowest estimation error when using daily time, which is qualitative data trained with quantitative data. If some data has periodical properties, it seems effective using qualitative data to forecast.

우리나라 오염총량관리제도의 개선 및 적용: 1. 안양천 유역의 오염부하량 산정 (Improvement and Application of Total Maximum Daily Load Management System of Korea: 1. Calculation of Total Amount of Pollutant Load in the Anyangcheon Watershed)

  • 김경태;정은성;김상욱;이길성;성진영
    • 한국물환경학회지
    • /
    • 제25권6호
    • /
    • pp.972-978
    • /
    • 2009
  • This study modifies the present total maximum daily load (TMDL) system of Ministry of Environment and applies to the Anyangcheon watershed. Hydrologic Simulation Program-FORTRAN (HSPF) model is used to simulate both runoff and non-point source pollution, simultaneously, instead of QUAL2E. The drought flow (355th daily flow) is proposed for the target water quantity since it is easier to satisfy low flow (275th daily flow) for the target water quality than drought flow. The increase of discharge is more than the increase of pollutant load except for the period under low flow. The measured unit loads for non-point source are used to consider the regional runoff characteristics. The measured water quantity and quality data are used since the ministry of environment supports only water quality. This analysis results show some reasons for the improvement of the present TMDL system of Korea.

투수성 포장도로 도입을 통한 보광배수유역 유출량 저감효과 검토 (Effects of porous pavement on runoff reduction in Boguang subcatchment)

  • 정지윤;이건영;류재나;오재일
    • 상하수도학회지
    • /
    • 제27권2호
    • /
    • pp.251-259
    • /
    • 2013
  • Among various Green Infrastructure measures for urban stormwater management, effects of porous pavement were quantitatively examined in terms of hydrological cycle. Different scenarios for porous pavement were introduced on a SWMM model and the effects were compared and analysed using discharge hydrographs. Two types of pavements having different runoff coefficients (0.05 & 0.5) were introduced to cover different ratio of entire road areas (100 %, 77.5 % and 40.4 %) and these made up in total 6 different scenarios. Total runoff volume was reduced and peak flow was significantly decreased by applying the porous pavement. The highest reduction for total runoff was shown from S-6(covering area: 100 %, runoff coefficient: 0.05) as 19 % followed by S-5(covering area: 77.5 %, runoff coefficient: 0.05, 16 %), while that of S-2(covering area: 40.4 %, runoff coefficient: 0.05) and S-1(covering area: 40.4 %, runoff coefficient: 0.5) were the lowest with 8 % and 5 %. This proved that the application of porous pavement would improve urban hydrological cycle.

Lifetime Management Method of Lithium-ion battery for Energy Storage System

  • Won, Il-Kuen;Choo, Kyoung-Min;Lee, Soon-Ryung;Lee, Jung-Hyo;Won, Chung-Yuen
    • Journal of Electrical Engineering and Technology
    • /
    • 제13권3호
    • /
    • pp.1173-1184
    • /
    • 2018
  • The lifetime of a lithium-ion battery is one of the most important issues of the energy storage system (ESS) because of its stable and reliable operation. In this paper, the lifetime management method of the lithium-ion battery for energy storage system is proposed. The lifetime of the lithium-ion battery varies, depending on the power usage, operation condition, and, especially the selected depth of discharge (DOD). The proposed method estimates the total lifetime of the lithium-ion battery by calculating the total transferable energy corresponding to the selected DOD and achievable cycle (ACC) data. It is also demonstrated that the battery model can obtain state of charge (SOC) corresponding to the ESS operation simultaneously. The simulation results are presented performing the proposed lifetime management method. Also, the total revenue and entire lifetime prediction of a lithium-ion battery of ESS are presented considering the DOD, operation and various condition for the nations of USA and Korea using the proposed method.

멀티 플라즈마 공정을 이용한 하수 미생물의 불활성화 (Inactivation of Sewage Microorganisms using Multi-Plasma Process)

  • 김동석;박영식
    • 한국환경과학회지
    • /
    • 제23권5호
    • /
    • pp.985-993
    • /
    • 2014
  • For the field application of dielectric barrier discharge plasma reactor, a multi-plasma reactor was investigated for the inactivation of microorganisms in sewage. We also considered the possibility of degradation of non-biodegradable matter ($UV_{254}$) and total organic carbon (TOC) in sewage. The multi-plasma reactor in this study was divided into high voltage neon transformers, gas supply unit and three plasma modules (consist of discharge, ground electrode and quartz dielectric tube). The experimental results showed that the inactivation of microorganisms with treated water type ranked in the following order: distilled water > synthetic sewage effluent >> real sewage effluent. The dissolved various components in the real sewage effluent highly influenced the performance of the inactivation of microorganisms. After continuous plasma treatment for 10 min at 180 V, residual microorganisms appeared below 2 log and $UV_{254}$ absorbance (showing a non-biodegradable substance in water) and TOC removal rate were 27.5% and 8.5%, respectively. Therefore, when the sewage effluent is treated with plasma, it can be expected the inactivation of microorganisms and additional improvement of water quality. It was observed that the $NH_4{^+}$-N and $PO{_4}^{3-}$-P concentrations of sewage was kept at the constant plasma discharging for 30 min. On the other hand, $NO_3{^-}$-N concentration was increased with proceeding of the plasma discharge.

제논 혼합가스를 이용한 고효율 면광원과 국부적 밝기 제어 방식 (High Luminous Efficiency Flat Light Source with Xe mixture Gas Discharge and Areal Brightness Control Method)

  • 정재철;서인우;오병주;황기웅
    • 한국조명전기설비학회:학술대회논문집
    • /
    • 한국조명전기설비학회 2009년도 추계학술대회 논문집
    • /
    • pp.153-157
    • /
    • 2009
  • A Highly efficient Mercury-free Flat Fluorescent Lamp (MFFL) with dielectric barrier Xe gas discharge was developed for an alternative of conventional line-type Cold Cathode Fluorescent Lamps (CCFLs) which shows a wide voltage margin and a stable discharge operation for diffuse glow discharge with an application of a auxiliary electrode. Electro-optic characteristics of the MFFL were examined through the changes in ambient temperature, total pressure and Xe partial pressure. the single cell is expanded into a multi-structured configuration to realize a large sized lamp by a simple repetition of the single cells, and a new driving scheme is proposed for an adaptive brightness control using dual auxiliary electrodes and bi-polar drive scheme. In addition, interesting application of this ultra high luminance flat lamp by the optimization of the gas condition and the pattern of the rear phosphor layer is suggested as a good alternative of daylight lamp source

  • PDF

Application of SA-SVM Incremental Algorithm in GIS PD Pattern Recognition

  • Tang, Ju;Zhuo, Ran;Wang, DiBo;Wu, JianRong;Zhang, XiaoXing
    • Journal of Electrical Engineering and Technology
    • /
    • 제11권1호
    • /
    • pp.192-199
    • /
    • 2016
  • With changes in insulated defects, the environment, and so on, new partial discharge (PD) data are highly different from the original samples. It leads to a decrease in on-line recognition rate. The UHF signal and pulse current signal of four kinds of typical artificial defect models in gas insulated switchgear (GIS) are obtained simultaneously by experiment. The relationship map of ultra-high frequency (UHF) cumulative energy and its corresponding apparent discharge of four kinds of typical artificial defect models are plotted. UHF cumulative energy and its corresponding apparent discharge are used as inputs. The support vector machine (SVM) incremental method is constructed. Examples show that the PD SVM incremental method based on simulated annealing (SA) effectively speeds up the data update rate and improves the adaptability of the classifier compared with the original method, in that the total sample is constituted by the old and new data. The PD SVM incremental method is a better pattern recognition technology for PD on-line monitoring.

신고리원자력발전소 주변 해역 조간대의 해조상 및 군집구조 (Marine Algal Flora and Community Structure of the Intertidal Zone around Shingori Nuclear Power Plant, Korea)

  • 한수진;장재길;황용훈;손민호;최한길
    • 한국수산과학회지
    • /
    • 제50권3호
    • /
    • pp.319-325
    • /
    • 2017
  • Marine algal flora and community structures were examined seasonally at three sites around the Shingori Nuclear Power Plant, Korea from February to November 2016. A total of 76 species were identified, including 9 green, 14 brown and 53 red algae. The greatest number of species occurred at Daesongri (51 species) followed by Sinamri (43 species) and at the discharge area (38 species) during the study period. Of the 76 seaweeds, 59 annuals and 17 warm tolerant species were recorded. Annual average biomass in dry weight varied from $168.02g/m^2$ at the discharge area to $222.53g/m^2$ at Sinamri. The coarsely branched form was the dominant functional form of seaweeds at the three sites. Seaweed community structures at the discharge site were distinguishable by decreasing species richness, biomass, species diversity index, richness index, and evenness index. The ratio of warm tolerance species and the dominance index values were remarkably higher at the discharge than those at the other sites.

Generation of Model Diesel Particles by Spark Discharge and Hydrocarbon Condensation

  • Kim, Hak-Joon;Kim, Jin-Ho;Choi, Young-Joo;Oh, Hyen-Chul;Chu, Jung-Bum;Kim, Sang-Soo
    • Journal of Mechanical Science and Technology
    • /
    • 제20권11호
    • /
    • pp.1972-1979
    • /
    • 2006
  • This study was conducted in order to generate model particles which were similar to particles in diesel emission. Spark discharge was used for carbon agglomerates and hydrocarbon condensation for particles that consist of carbon agglomerates and hydrocarbon. The size of the carbon agglomerates, whose mean size were 30 and 70 nm, ranged between 15 and 200 nm, and the total number concentration of the particles ranged from 3 to $5{\times}10^7#/cm^3$ as the controllable variables in spark discharge generator changed. The result of the hydrocarbon condensation experiment showed that the final sizes of the particles enlarged by condensation did not depend on the initial sizes, but the maximum condensational growth of carbon agglomerates by dodecane ($C_{12}H_{26}$) condensation was 112 times the initial size of 40 nm, while the size of the agglomerates by benzene ($C_6H_6$) was 3.25 times its initial size.

개별화된 교육이 허혈성 뇌졸중 환자의 불안과 자가간호수행에 미치는 효과 (The Effects of Individualized Education on Stroke Patients' Post-discharge Anxiety and Self-care Compliance)

  • 박형숙;이미헌;하재현
    • 재활간호학회지
    • /
    • 제16권1호
    • /
    • pp.1-8
    • /
    • 2013
  • Purpose: This study aimed to identify the effect of individualized education on stroke patients' post-discharge anxiety and self-care compliance. Methods: It was a pretest-posttest design with non-equivalent groups. A total of 32 hospitalized stroke patients in experimental group were given individualized education three times at one day before, the day of and one week after discharge. Data were analyzed using descriptive statistics, t-test and $x^2$-test. Results: The scores of anxiety at posttest were $45.66{\pm}9.58$ in control group and $35.44{\pm}8.21$ in the experimental group. Self-compliance scores were $44.00{\pm}7.99$ in control and $61.06{\pm}7.69$ in the experimental group. These indicate that anxiety score is significantly lower (t=-4.58, p<.001), and self-compliance score is significantly higher (t=8.70, p<.001) in experimental group. Conclusion: If stroke patients receive a relevant individualized education, it could help reduce their anxiety. Also it would be useful to maintain and improve their self-care compliance after discharge.