• Title/Summary/Keyword: total deposition

Search Result 624, Processing Time 0.028 seconds

A Study on the Development of Standard Method of Total Deposition Sampling in Air Pollutants - Spatial Distribution of Total Deposition by the Filtration-Sampling Method - (대기오염 총침착물의 채취방법 표준화 개발에 관한 연구 -여과식 채취방법을 통한 총침착물의 공간분포 특성-)

  • 박정호;조인철;김찬훈;서정민
    • Journal of Environmental Science International
    • /
    • v.11 no.6
    • /
    • pp.489-496
    • /
    • 2002
  • The purpose of this study was to investigate spatial distributions of total deposition. A total number 79 samples were collected at 17 sampling sites from September 1999 to January 2000. Total (=wet+dry) atmospheric depositions were collected by filtered deposition sampler at sampling site (the Western Part of Kyongsangnam Province). In addition, the deposition of soluble and insoluble fraction was also investigated to find a suitable simplified collection method for a long-term monitoring of total deposition. The total depositions were measured soluble amount(mm/month), insoluble amount(kg/km$^2$/month), pH, conductivity(E.C.) and eight ionic components. The spatial distribution of deposition flux was to estimated by using a kringing analysis. The 17 sites mean fluxes of water soluble ionic components; SO$_4$$\^$2-/, Cl$\^$-/, NO$_3$$\^$-/, Na$\^$+/, NH$_4$$\^$+/, K$\^$+/, Mg$\^$2+/, Ca$\^$2+/ were 100.7∼315.6kg/km$^2$/month, 30.1∼234.3kg/km$^2$/month, 64.4∼ 139.4kg/km$^2$/month, 7.5∼68.3kg/km$^2$/month, 10.7∼48.7kg/km$^2$/month, 5.6∼27.9kg/km$^2$/month, 4.5∼17.5kg/km$^2$/month, 27.6∼81.7kg/km$^2$/month, respectively.

Effects of the Block Distance of Collecting Plate and Particle Size on the particle Deposition Efficiency in the Two-Stage Electrostatic Precipitator (2단식 전기집진기의 집진판 블록간격 및 입자크기가 입자의 부착효율에 미치는 영향)

  • 박청연
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.16 no.2
    • /
    • pp.165-178
    • /
    • 2000
  • In this study the effects of block distance have been investigated on the particle deposition efficiency in the collecting cell of two-stage electrostatic precipitator by numerical analysis. Particle trajectories have been changed by the electrostatic and inertial force of particle with the inlet velocity electrostatic number and particle diameter. The total deposition efficiency has a minimum value by the interaction between the effect of particle inertial force and electrostatic force in the collecting cell. The increase of block distance makes the total deposition efficiency decrease under the range of the particle size which has the minimum deposition efficiency. However beyond the range of particle size which has minimum deposition efficiency total deposition efficiency has no trend with the variation of block distance.

  • PDF

The Effects of Varying Sampling Flow Rates on the Measurements of Total Nitrate and Sulfate in Dry Acid Deposition

  • Park, Jong-Kil;Kim, Jo-Chun
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.18 no.E1
    • /
    • pp.1-12
    • /
    • 2002
  • One technique for determining dry acid deposition fluxes involves measurement of time - averaged ambient concentrations of dry acid deposition species using filter packs (FP) coupled with estimates of mean deposition velocities for the exposure period. A critical problem associated with filter pack data comparisons between various field sampling networks is the use of diverse sampling flow rates and duration protocols. Field experiments were conducted to evaluate the effects of varying sampling flow rates, from 1.5 to 10 standard liters per minute, on total nitrate and sulfate measurements of specific dry acid deposition species . Collocated FP samplers were used to determine sampling and analysis data reproducibility and representativeness . Ambient air samples were simultaneously collected using groups of filter packs operated at various flow rates over identical 7 day periods. The species measured were sulfur dioxide, particulate sulfate , nitric acid and particulate nitrate. Statistical results (ANOVA; alpha level 5%) showed that neither the low nor high sampling flow rates caused a significant difference in the measurements of total sulfate and adjusted total nitrate (ATN) . However, it was concluded that for high flow rate sampling measurements, total nitrate (TN) could be affected during extended sampling durations because of potential nitric acid overloading and breakthrough. Although the previous workers (Costello, 1990; Quillian, 1990) used much higher sampling flow rates (~ 17 sLpm) than employed here, it was assumed that for a high loading (> 50$\mu\textrm{g}$ HNO$_3$) of nitric acid on the Nylon filters, a significant fraction (~10%) of nitric acid could pass through the Nylon filters and be collected on the carbonate impregnated filters. It was concluded that even at the highest sampling flow rate employed (10 sLpm) at the Cary Forest site, nitric acid breakthrough was less than 10% of the total HNO$_3$ collected. However, for a heavily polluted urban airshed or with longer sampling times , higher filter loadings could result in substantial nitric acid breakthrough and HNO$_3$concentrations would be underestimated.

Study on Characterization of Deposition Flux of Dustfall in Kunsan, Korea

  • Kim, Seong-Cheon
    • Journal of Environmental Health Sciences
    • /
    • v.29 no.4
    • /
    • pp.42-47
    • /
    • 2003
  • The purpose of this experimental study is to investigate seasonal deposition flux variations of the total dustfall and various inorganic elements in it. Total of 84 dustfall samples were collected from September, 1997 thru August, 1998 at 7 different sites in Kunsan. Each sample was analyzed by an AAS to determine the levels of 5 inorganic elements; Zn, Cd, Cr, Fe and Pb. Deposition fluxes, soluble/total fractions for each element were extensively investigated. Estimated deposition fluxes of dustfall and elements in Kunsan were in the range of 37.5∼45.1 ton/$\textrm{km}^2$/yr for dustfall, 43.5∼81.8 kg/$\textrm{km}^2$/yr for Zn, 6.6∼11.0 kg/$\textrm{km}^2$/yr for Cd, 44.8∼110.0 kg/$\textrm{km}^2$/yr for Cr, 223∼323 kg/$\textrm{km}^2$/yr for Fe, 10.9∼22.3 kg/$\textrm{km}^2$/yr for Pb, respectively. Thus, the estimated average total deposition fluxes of dustfall in Kunsan(376.35 $\textrm{km}^2$) per day were 43.3 ton and 58.6 kg for Zn, 8.9 kg for Cd, 80.6 kg for Cr, 293.8 kg for Fe and 14.1 kg for Pb, respectively.

Gas/Particle Level and Dry Deposition Flux of Atmospheric PCBs

  • Yeo, Hyun-Gu;Park, Ki-Chul
    • Journal of Environmental Health Sciences
    • /
    • v.29 no.4
    • /
    • pp.10-16
    • /
    • 2003
  • Atmospheric samples were conducted from September 2001 to July 2002 with GPS-l PUF sampler in rural site to concentration distributions of gas/particle PCBs and to calculate dry deposition flux of PCBs. $\Sigma$PCBs concentrations of gas/particle PCBs were 59.29$\pm$48.83, 6.56$\pm$6.59 pg/㎥, respectively. Gas contribution (%) of total PCBs (gas + particle) was 90% which existed gas phase in the atmosphere. The particle contribution (%) of PCB congeners increased relatively more of the less volatile congeners with the highest chlorine number. The correlation coefficients (r) between total PCBs and temperature ($^{\circ}C$) showed negative correlation in - 0.62 (p<0.0l) for particle phase, positive correlation in 0.63 (p<0.01) for gas phase. In other word, particle phase PCBs is enriched in colder weather which could be due to greater in corporation of condensed gas phase at low temperature. The calculated dry deposition of total PCBs (gas + particle) was 0.008, 0.008 $\mu\textrm{g}$ $m^{-2}$ da $y^{-l}$ which showed maximum dry deposition flux in December, minimum data in July Bs in the atmosphere. The calculated dry deposition fluxes of total PCBs were influenced by particle phase PCBs even though PCBs in the atmosphere were present primarily in the gas phase.e.

Study on the Asymmetric Regional Deposition of Airborne Pollutant Particles in the Human Respiratory Tract (대기오염 입자의 인체 호흡기내 비대칭 국부침전 특성에 관한 연구)

  • 구재학;김종숭
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.19 no.5
    • /
    • pp.551-560
    • /
    • 2003
  • Particle deposition in human lungs was investigated theoretically by using asymmetric five-lobe lung model. The volumes of each of the five lobes were different, thereby forming an asymmetric lung structure. The tidal volume and flow rate of each lobe were scaled according to lobar volume. The total and regional deposition with various breathing patterns were calculated by means of tracking volume segments and accounting for particle loss during inhalation and exhalation. The deposition fractions were obtained for each airway generation and lung lobe, and dominant deposition mechanisms were investigated for different size particles. Results show that the tidal volume and flow rate have a characteristic influence on particle deposition. The total deposition fraction increases with an increase in tidal volume for all particle sizes. However, flow rate has dichotomous effects: a higher flow rate results in a sharp increase in deposition for large size particles, but decreases deposition for small size particles. Deposition distribution within the lung shifts proximally with higher flow rate whereas deposition peak shifts to the deeper lung region with larger tidal volume. Deposition fraction in each lobe was proportional to its volume. Among the three main deposition mechanisms, diffusion was dominant for particles < 0.5 ${\mu}{\textrm}{m}$ whereas sedimentation and impaction were most influential for larger size particles. Impaction was particularly dominant for particles> 8 ${\mu}{\textrm}{m}$. The results may prove to be useful for estimating deposition dose of inhaled pollutant particles at various breathing conditions.

Residence Time Effect on the Growth of ZrC by Low Pressure Chemical Vapor Deposition (저압화학기상증착법을 이용한 ZrC 성장에 잔류시간이 미치는 영향)

  • Park, Jong-Hoon;Jung, Choong-Hwan;Kim, Do-Jin;Park, Ji-Yeon
    • Journal of the Korean Ceramic Society
    • /
    • v.45 no.5
    • /
    • pp.280-284
    • /
    • 2008
  • In order to investigate residence time effect on the growth of ZrC film, the ZrC films grew with various system total pressure (P) and total flow rate (Q) by low pressure chemical vapor deposition because residence time is function of system total pressure and total flow rate. Thermodynamic calculations predict that the decomposition of source gases ($ZrCl_4$ and $CH_4$) would be low as increasing the residence time. Thermodynamic calculations results were proved by investigating deposition rate with various residence time. Deposition rate decreased with residence time of source gas increased. Besides, depletion effect accelerated diminution of deposition rate at high residence time. On the other hands, the deposition rated was increased as decreasing the residence time because fast moving of intermediate gas species decrease the depletion effect. The crystal structure was not changed with residence time. However, the largest size of faceted grain showed up to specific residence time and the size of grain was decreased whether residence time increase or not.

Estimation of Deposition Rates of Dustfall and Metallic Elements in Kunsan (군산지역의 강하분진 및 금속원소의 침착속도 추정)

  • 김성천
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.16 no.5
    • /
    • pp.431-443
    • /
    • 2000
  • The purpose of this experimental study is to investigate seasonal deposition flux variations and deposition velocities of the total dusfall and various inorganic elements in it. Total 41 dustfall and TSP samples were collected from November, 1997 through December, 1998 in Kunsan. Each sample was analyzed by and AAS to determine he levels of 5 inorganic elements: Zn, Cd, Cr, Fe and Pb. Deposition fluxes, soluble/total fractions and deposition velocities for each element were extensively investigated. Estimated dry deposition fluxes of dustfall and elements in Kunsan were in the range of 14.6~48.8(mean 25.6) ton/$\textrm{km}^2$/yr for dustfall, 14.5~72.6(mean 44.1)kg/$\textrm{km}^2$/yr for Zn, 0.9~0.5(mean 3.0) kg/$\textrm{km}^2$/yr for Cd, 2.1~239.2(mean 63.9) kg/$\textrm{km}^2$/yr for Cr, 331.6~1,082.7(mean 873.9) kg/$\textrm{km}^2$/yr for Fe, 5.2~178.4(mean 49.2) kg/$\textrm{km}^2$/yr for Pb, respectively. And the concentra-tion of TSP and elements in Kunsan were 71$\mu\textrm{g}/m^3$ for TSP, $29.9ng/m^3$ for Zn, $0.6ng/m^3$ for Cd, $0.1 ng/m^3$ for Cr, $1,061.0 ng/m^3$ for Fe, $4.0 ng/m^3$ for Pb, respectively. And the estimated deposition velocity of dustfall and elements in Kunsan were 1.13$\times$ 10(sup)-2 cm/sec for dustfall, 4.67$\times$ 10(sup)-2 cm/sec for Zn, 16.92 cm/sec for Cd, 15.69 cm/sec for Cr, 1.72$\times$ 10(sup)-2 cm/sec for Fe, 0.36 cm/sec for Pb, respectively.

  • PDF

Study of Deposition Flux of Dustfall and Metallic Elements in Western Coastal City, Kunsan, Korea (서해 도시지역 군산의 강하분진 및 금속원소 침착량 연구)

  • 김성천
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.15 no.3
    • /
    • pp.291-303
    • /
    • 1999
  • The purpose of this experimental study is to investigate seasonal deposition flux variations of the total dustfall and various inorganic elements in it. Total of 84 dustfall samples were collected from September, 1997 thur August, 1998 at 7 different sites in Kunsan. Each sample was analyzed by an AAS to determine the levels of 5 inorganic elements Zn, Cd, Cr, Fe and Pb. Deposition fluxes, soluble/total fractions for each element were extensively investigated. Estimated depositon fluxes of dustfall and elements in Kunsan were in the range of 37.5~45.1 ton/$ extrm{km}^2$/yr for dustfall, 43.5~81.8kg/$\textrm{km}^2$/yr for Zn, 6.6~11.0kg/$\textrm{km}^2$/yr for Cd, 44.8~110.0kg/$\textrm{km}^2$/yr for Cr, 223~323 kg/$\textrm{km}^2$/yr for Fe, 10.9~22.3 kg/$\textrm{km}^2$/yr for Pb, respectively. Thus, the estimated average total deposition fluxes of dustfall in Kunsan(376.35$\textrm{km}^2$) per day were 43.3 ton and 58.6 kg for Zn, 8.9 kg for Cd, 80.6 kg for Cr, 293.8 kg for Fe and 14.1 kg for Pb, respectively.

  • PDF

A Numerical Study on the Size and Depositions of Yellow Sand Events (황사의 크기 및 침착량에 대한 수치 모의)

  • 정관영;박순웅
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.14 no.3
    • /
    • pp.191-208
    • /
    • 1998
  • Estimations of dry and wet depositions in Korea and the size distributions of yellow sand above Korea have been carried out using the Eulerian aerosol model with the simulated meteorological data from the SNU mesoscale meteorological model. The estimated particle size distribution in Korea shows a bimodal distribution with peak values at 0.6 pm and 7 pm and a minimum at 2 pm in the lower layer However, as higher up, the bimodal distribution becomes an unimodal distribution with a peak value at 4∼5mm. Among the total amount of yellow sand deflated in the source regions , the dry and wet deposition fluxes were about 92%, and about 1.3∼0.5%, repectively, and the rest(5∼6%) is suspended in the air, Most of dust lifted in the air during the clear weather is deposited in the vicinity of the source regions by dry deposition and the rest undergoes the long -range transport with a gradual removal by the wet deposition processes. Over Korean peninsula, the total amount of yellow sand suspended in the air was about 6∼8% of the emissions in the source region and the dry and wet deposition fluxes were about 0.005∼0.7% and 0.003∼0.051% of the total emitted amount, repectively. It is estimated that 2.7∼8.9 mesa-tons of yellow sand is transported annually over the Korean peninsula with the annual mean dry deposition of 2.1∼490 kilo-tons and the annual mean wet deposition of 1.5∼65 kilo-tons.

  • PDF