• Title/Summary/Keyword: total correction

Search Result 751, Processing Time 0.033 seconds

A Study on Perception of 'Environmental Pollution' Concepts In the Elementary School Students (초등학생들의 환경오염 개념에 대한 인식 수준 연구)

  • Hong, Seung-Ho
    • Hwankyungkyoyuk
    • /
    • v.22 no.3
    • /
    • pp.63-71
    • /
    • 2009
  • The aim of this study is to provide the basic data on misconception correction through the investigation of perception extent for 'environmental pollution' concepts in the elementary school students. For this, 18 investigation questions for concepts were created. And then a questionnaire was inputted for 446 elementary school students. The rate of average wrong answer for total questions was 34.9%. The eight questions were appeared as rate of wrong answers over average, suggesting that the misconception extent for 'environmental pollution' was still high. The extent of concepts for total questions between living environments of the study subjects did not show any significant differences. However, the urban students had significantly higher rate of wrong answers than rural students in the three questions, indicating that it is necessary to develop various teaching-learning materials on 'environmental pollution'. Therefore, the teachers have to study the various ways to induce the cognition conflicts through the application of proper teaching-learning for correction of 'environmental pollution' concepts.

  • PDF

Total Correction of Tetralogy of Fallot Review of 100 consecutive patients (Fallot 사징증의 완전교정에 대한 임상 경험: 100례 보고)

  • 박국양
    • Journal of Chest Surgery
    • /
    • v.18 no.4
    • /
    • pp.598-604
    • /
    • 1985
  • One hundred consecutive patients with the Tetralogy of Fallot underwent total correction at National Medical Center during the period 1977 to 1984, Oct. During this study period, we adopted more active policy towards reconstruction of right ventricular outflow tract across pulmonary valve. The mortality was 48% for patients less than 15 kg and 19% in patients above 15kg. Initially Bretschneider`s solution was used as cardioplegia, which was replaced by St. Thomas` solution since 1983, Jan. After then overall mortality dropped to 9% compared to 45% of initial learning period. Heart block occurred In 11 patients, 10 of whom died of combined low cardiac output syndrome. Pure low cardiac output syndrome was noted in 18 patients, most of whom responded to medical measures well except 4 patients. Recently sepsis of Serratia marcescence, which occurred explosively during several months to open heart surgery patients, attacked 3 tetralogy patients resulting in 2 hospital deaths. Our experience has shown that body weight, choice of cardioplegia and accumulation of experience as well as advance of operative and postoperative techniques are still important factors affecting survival rate at initial learning period.

  • PDF

Analysis of Postoperative Complications in Blepharoptosis (안검하수 교정술 후 생긴 합병증 분석)

  • Oh, Chang Hyun;Park, Dae Hwan;Kim, Peter Chan Woo;Shim, Jeong Su;Lee, Yong Jig
    • Archives of Plastic Surgery
    • /
    • v.36 no.6
    • /
    • pp.743-749
    • /
    • 2009
  • Purpose: Many researches about various surgical method for blepharoptosis have already been introduced. But researches for complications after blepharoptosis correction is relatively insufficient. So, this study was performed to recognize common complications that arised depending on the severity of blepharoptosis, levator function and surgical method. Methods: 250 patients who have underwent surgical treatment for blepharoptosis from 1987 to 2006 were employed in this study. Patients were categorized by severity of blepharoptosis, levator function and surgical method that has been used. Complications after blepharoptosis correction were analyzed. Result: Total of 64 patients had occurred complications, the specifics are as following; undercorrection 22, asymmetry 13, overcorrection 12, lagophthalmos 4, abnormal eyelid contour 4, exposure keratitis 3, ectropion 2, inclusion cyst 2, infection 1 and conjunctival prolapse 1. Among above patients, 3 patients had two kinds of complications. 21 patients was underwent secondary surgery due to complication. Conclusion: Evaluating the outcomes of the secondary surgery, the early correction was better than the late correction. The most of the complications were recovered through conservative and surgical treatments. The most of the complications (47 patients) were undercorrection, asymmetry, overcorrection and took 73.4% of the total complications. The more severe the blepharoptosis and the more poor the levator function, the rate of complications were higher. According to the operation methods, most complications were occurred in levator operation, frontalis transfer and OOM flap.

A novel controller for switching audio power amplifier with digital input (디지털 PWM 입력 D급 음향 증폭기를 위한 새로운 제어기법)

  • Park, Jong-Hu;Kim, C.G.;Cho, B.H.
    • Proceedings of the KIEE Conference
    • /
    • 2002.07b
    • /
    • pp.976-979
    • /
    • 2002
  • A new controller for switching audio power amplifier with digital PWM input is proposed- Bi-directional Saw-tooth Error Correction (BSEC). This control method for high quality switching amplifier is based on a pulsed edge correction approach using PWM audio signal input as a reference of power switching digital to analog converter. The proposed controller has excellent features such as wide error correction range and no limitation on the modulation index. The controller is implemented in the half-bridge class D amplifier and the performance is verified through hardware experiments. It delivers 100W into 4${\Omega}$ load with less than 0.2% of total harmonic distortion (THD) all over operating range and an maximum efficiency of 82%.

  • PDF

The ML scale in southern Korea (한반도 남부 지진의 지역 규모식)

  • 홍태경
    • Proceedings of the Earthquake Engineering Society of Korea Conference
    • /
    • 2000.10a
    • /
    • pp.73-80
    • /
    • 2000
  • The distance correction term -logA0 of the local magnitude scale was estimated for earthquakes in southern Korea using linear least-squares inversion and interpolation scheme. Total 1054 short-period velocity seismograms from 107 local events recorded at hypocentral distances ranging from 10 to 480 km were used in this study. Simulated Wood-Anderson amplitudes were obtained from velocity seismograms with use of revised Wood-Anderson instrument response with static magnification 2080, damping factor 0.7, and natural period 0.8 sec. The estimated distance correction term for southern Korea is found to be -logA0=1.137 log(r/17) + 0.001159(r-17) + 20, where r is hypocentral distance in kilometers. The attenuation rate of this distance correction term falls between those of southern California and eastern North America.

  • PDF

Surgical Correction of Pulmonary Atresia with VSD -Report of a Case- (심실 중격 결손증을 동반한 폐동맥 폐쇄증의 외과적 교정)

  • 김대영
    • Journal of Chest Surgery
    • /
    • v.28 no.11
    • /
    • pp.1045-1048
    • /
    • 1995
  • Pulmonary atresia with VSD is uncommon congenital anomaly with high mortality in neonatal period.Recently we experienced surgical correction of pulmonary atresia with VSD. The case was 2 month old male patient diagnosed as pulmonary atresia with VSD and PDA. Atretic pulmonary artery segment from Rt ventricular infundibulum to pulmonary artery was lcm in length. The pulmonary trunk tapered toward Right ventricular infundibulum and resulted in blind pouch with diameter of lmm. The left pulmonary artery was stenosed at just proximal and distal part to which PDA was connected. Total correction was undertaken which consisted of PDA ligation, dacron patch closure of VSD, establishment of continuity between right ventricle and pulmonary artery with autogenous pericardium. Postoperative systolic fight ventricular pressure and left ventricular pressure ratio was 0.7. In patient with pulmonary atresia with VSD it is advisable to perform a corrective operation, whenever the size and anatomy of pulmonary artery are acceptable for it.

  • PDF

Inverter Driven Air-Conditioner With Power Factor Correction Circuit (역률제어회로를 갖는 인버터 구동 에어컨)

  • 권경안;박병욱;김정태;정용채
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.4 no.1
    • /
    • pp.105-110
    • /
    • 1999
  • This paper describes the inverter driven air-condetioner with power factor correction (PFC) circuit. By adopting PFC in the rectifier, we can reduce harmonic injection into power line, improve the efficiency and lower the total system cost compared to conventional inverter only. Also, system performance is improved by stabilizing the output voltage of PFC. In this paper, detailed design procedures for PFC are given, and the several merits with PFC are verified through the simulation and experiment.

Digital Magnetic Compass With Smart Correction Function - Recent Experimental Results and Further Works -

  • Yim, Jeong-Bin;Shim, Yeong-Ho;Kim, Chang-Kyeong;Choi, Gi-Young
    • Proceedings of the Korean Institute of Navigation and Port Research Conference
    • /
    • 2004.08a
    • /
    • pp.29-36
    • /
    • 2004
  • The paper describes recent experimental results on the development of Digital Magnetic Compass (DMC), which can provide smart automatic correction functions to the magnetic interferences. The design methodology of magnetic sensing circuit with ring-core fluxgate sensor is represented. The performance results of the sensing circuits are discussed with error analysis by polynomial regressions. As test results, the sensing circuit filtered only the second harmonic signal that is proportional to the direction of earth's magnetic field, and it leads to the obtainment of bearing information. In addition, the total residual errors of DMC can be analyzed by the adoption of polynomial regressions. It shown that the possibility of high precise DMC, in the future.

  • PDF

Energy Savings in OFDM Systems through Cooperative Relaying

  • Khuong, Ho Van;Kong, Hyung-Yun
    • ETRI Journal
    • /
    • v.29 no.1
    • /
    • pp.27-35
    • /
    • 2007
  • Energy savings in orthogonal frequency division multiplexing (OFDM) systems is an active research area. In order to achieve a solution, we propose a new cooperative relaying scheme operated on a per subcarrier basis. This scheme improves the bit error rate (BER) performance of the conventional signal-to-noise ratio (SNR)-based selection relaying scheme by substituting SNR with symbol error probability (SEP) to evaluate the received signal quality at the relay more reliably. Since the cooperative relaying provides spatial diversity gain for each subcarrier, thus statistically enhancing the reliability of subcarriers at the destination, the total number of lost subcarriers due to deep fading is reduced. In other words, cooperative relaying can alleviate error symbols in a codeword so that the error correction capability of forward error correction codes can be fully exploited to improve the BER performance (or save transmission energy at a target BER). Monte-Carlo simulations validate the proposed approach.

  • PDF

Surgical Correction of Total Anomalous Pulmonary Venous Connection without Total Circulatory Arrest (완전 순환 정지 없이 시행한 총 폐정맥 환류 이상의 수술 교정)

  • Han Won Kyung;Cho Joon Yong;Lee Jong Tae;Kim Kyu Tae;Chang Bong Hyun;Lee Eung Bae
    • Journal of Chest Surgery
    • /
    • v.39 no.1 s.258
    • /
    • pp.12-17
    • /
    • 2006
  • Background: Circulatory arrest under deep hypothermia is an important auxiliary means for surgical correction of total anomalous pulmonary venous connection (TAPVC), However, cardiac operations under deep hypothermic circulatory arrest are associated with the risk of post-arrest neurologic abnormalities. The purpose of this study is to evaluate the results of the surgical correction of total anomalous pulmonary venous connection without the total circulatory arrest. Materiai and Method: Between April 2000 and October 2004, hospital records of 10 patients were reviewed retrospectively. Result: The locations for abnormal anatomical connections were supracardiac in 7 cases, cardiac in 1 case, and infracardiac in 2 cases. The mean cardiopulmonary bypass time and aorta cross clamp time were 116.8$\pm$40.7 and 69.5$\pm$24.1 minutes. There was no surgical mortality. Postoperative complications were post-repair pulmonary venous stenosis in 1 case, pneumonia in 1, pneumothorax in 1, wound infection in 1,and diaphragmatic paralysis in 1. All patients without pulmonary venous stenosis were in NYHA class I at mean follow-up of 16.6 months (3$\∼$49 months) Conclusion: We could obtain excellent results by repair without the total circulatory arrest for total anomalous pulmonary venous connection.