• 제목/요약/키워드: torso body

검색결과 193건 처리시간 0.023초

청진 훈련 모형용 청음판 검출 알고리즘 개발 (The Development of Chestpiece Detecting Techniques for Physical Assessment Trainer)

  • 장인배;오수환;이영석
    • 한국정밀공학회지
    • /
    • 제31권6호
    • /
    • pp.527-534
    • /
    • 2014
  • The control system of human torso model and driving system of stethoscope for physical assessment trainer are developed. The detecting characteristics of circular pickup coil which is driven by square wave voltage signal with resonance frequency of LC circuits are investigated and it is confirmed that the pickup coil can detect the existence of chestpiece near the coil region. The control system of human torso model is composed of 8 channel pickup coils, Mp3 and Bluetooth module. The driving system of stethoscope is composed of chestpiece with contact switch and Bluetooth headset. The chestpiece detecting algorithm check the contact of chestpiece with human body model first and excite the pickup coil sequentially to find the location. The proposed system can be applied the physical assessment trainer.

길의 진동둘레선 설계를 위한 체표전개도 분석에 관한 연구 (Analysis of Body Surface Developments for the Pattern of Armhole line)

  • 이정란
    • 한국의류학회지
    • /
    • 제21권6호
    • /
    • pp.1031-1040
    • /
    • 1997
  • This study was done to analyze the body surface developments of armhole area. The major conclusions of this study are: 1. The body surface developments showed the characteristics of expansion and contraction of body at armhole area. By arm movements, front armhole lines on the body surface developments of upper arm were slow going, but back armhole lines were full and round. As a whole, armhole line of the back torso was swollen outside especially at backarmpit point area, it seemed like a line of raglan sleeve. 2. Regression Analysis was carried out to adapt armhole line on the upper arm and upper body to bodice and sleeve pattern, following the axillary circumference line and chest breadth line changed to the basic pattern form. As the result, armhole lines of 90$^{\circ}$ and 135-180$^{\circ}$ movements deviated from those of standard posture. U-type, clear armhole curve of standard posture turned to V-type, slanting line by arm movements.

  • PDF

성인 남성용 런닝형 니퍼패턴 개발 (A Study on the Running Type Nipper Pattern Development for Adult men)

  • 조평훈;손후조;나미향
    • 한국생활과학회지
    • /
    • 제16권3호
    • /
    • pp.577-585
    • /
    • 2007
  • This research aimed for 20 latter man whose body shape of torso alters remarkably to develop nipper pattern of running type considered characteristic of body shape of 20 latter man to keep rather balanced body shape against middle age when body shape changes extremely. 1. running type nipper pattern design. Pattern of running, lining and nipper were designed by flattening surface shell. A basis line of running pattern is completed by applying reduction ratio after 3 times of modification & complement based on surface shell. Nipper pattern is designed with design line set by a plaster cast based on running pattern line. Lining pattern is designed with lining design line set by a plaster cast based on running type outside material and nipper pattern. 2. Functional evaluation of research and commercial nipper. Functional inspection through dress test was applied 5point evaluation method and the result of functional inspection on the sight of a wearer is that research nipper(running reduction ratio 15%, nipper reduction ratio 18%) averaged more 4.8point but commercial nipper averaged less 1.8point in the aspect of 20 items such as wear sensibility, motional function and external appearance aesthetic. Research running type nipper scored high in order of motional function, looks of side, back, front and whole and wear sensibility. Functional inspection in the point of view of an observer is that research nipper(running reduction ratio 15%, nipper reduction ratio 18%) averaged over 4.8point and commercial nipper averaged under 1.9point in 17 items of external appearance beauty. Research running type nipper marked high in order of looks of back, whole, front and side.

교복 설계를 위한 여자 청소년의 체형 변화 연구 (A Study on the Change of Body Composition of Female Adolescents for School Uniform Design)

  • 김서우;남윤자;김경선
    • 한국의류학회지
    • /
    • 제44권2호
    • /
    • pp.224-236
    • /
    • 2020
  • In this study, the 4th (1997) and 6th (2013) direct measurements of Size Korea compared the changing shape of women between the ages of 12 and 18. Comparing the items of height and length, the height and shoulder height were significantly reduced, the waist height was not significantly different, and the height of the upper hip was significantly increased, resulting in a smaller upper torso ratio and a higher lower torso rate. The width and thickness associated with human obesity, the circumference items and obesity levels often increased significantly with the change of the times, indicating that the overall body size was increased and that the chest area was changed to a cylindrical shape with changes in the breast equilibrium. Comparing agespecific measurements with graphs analyzing the trend of change in growth, the results showed that the change in 1997 was minimal since age 14; however, a continuous increase was achieved in 2013 that corresponded to the age at which growth is complete. The results of these studies are expected to be used as basic data to predict pattern design, body implementation, and trends in shape changes for young women.

전신 뼈 스캔 후 경과 시간 차이에 따른 $^{201}Tl$ 심근관류 SPECT 영상의 영향 평가 (The Influence Evaluation of $^{201}Tl$ Myocardial Perfusion SPECT Image According to the Elapsed Time Difference after the Whole Body Bone Scan)

  • 김동석;유희재;류재광;유재숙
    • 핵의학기술
    • /
    • 제14권1호
    • /
    • pp.67-72
    • /
    • 2010
  • 본원에서는 비심장 수술환자의 수술 전후 심장사건의 위험도 평가를 위해 심근관류 SPECT를 시행하고 있다. 암환자의 경우 수술 전에 전신 뼈 검사 혹은 전신 PET 검사로 암 전이 여부 확인 후 심근관류 SPECT를 시행하여 불필요한 검사 처방을 막고 있다. 하지만 단기 병동 입원 환자의 경우 재원 일수를 줄이고자 전신 뼈 검사 후 최소 16시간의 간격을 두고 $^{201}Tl$ 심근관류 SPECT를 시행하는 경우가 있지만 아직까지 서로 다른 동위원소 투여로 인한 crosstalk contamination의 영향에 대한 평가가 제대로 이루어지지 않은 실정이다. 따라서 본 연구에서는 anthropomorphic torso phantom을 이용한 실험과 실제 환자 데이터를 이용하여 이에 대한 유효성 검정을 시행하고자 한다. 2009년 8월부터 9월까지 서울아산병원 핵의학과에서 $^{201}Tl$ 심근관류 SPECT를 시행한 87명의 환자를 대상으로 연구 분석하였다. $^{201}Tl$ 심근관류 SPECT 시행 전날 전신 뼈 스캔 시행 여부에 따라 환자를 분류하였고 $^{201}Tl$ 심근관류 SPECT 촬영 시 이중 에너지 창을 이용하여 영상을 획득하였다. 획득한 영상에서 $^{201}Tl$ 창과 $^{99m}Tc$ 창에서 계수된 카운트의 비율을 전날 전신 뼈 검사의 시행 유무에 따라 비교 분석하였다. 실험에는 anthropomorphic torso phantom을 사용하였으며 심근($^{201}Tl$)과 심근 이외의 부분($^{99m}Tc$)에 각각 14.8 MBq, 44.4 MBq를 투여 하였다. 영상획득은 시간 간격을 두고 게이트 법 적용 없이 $^{201}Tl$ 심근관류 SPECT를 시행하여 얻었고 Xeleris ver 2.0551를 이용하여 공간 분해능을 측정 분석하였다. 수집한 환자 데이터에서 $^{201}Tl$ 창과 $^{99m}Tc$ 창에서 계수된 카운트 비율 비교 결과 전날 전신 뼈 스캔을 시행한 경우 Bone tracer 주입 후 12시간에서 24시간까지의 비율이 Ventri에서는 1:0.411 에서 1:0.114, Infinia에서는 1:0.249에서 1:0.079로 지수함수적으로 감소하며 시간 경과에 따라 유의한 차이(Ventri p=0.0001, Infinia p=0.0001)를 나타내었다. 또한 전신 뼈 스캔을 시행하지 않은 경우의 비율은 Ventri에서 평균 1:$0.067{\pm}0.006$, Infinia에서 1:$0.063{\pm}0.007$로 나타났다. Phantom 실험 후 공간 분해능 측정 결과는 $^{99m}Tc$의 첨가 여부와 시간 경과에 따라서 FWHM의 유의한 변화는 나타나지 않았다 (p=0.134). Anthropomorphic torso phantom을 이용한 실험과 환자 데이터 분석을 통해 bone tracer 주입 16시간 이 후에 시행된$^{201}Tl$ 심근관류 SPECT 영상은 $^{99m}Tc$에 의해 공간 분해능에 유의한 영향을 받지 않는다는 것을 확인하였다. 하지만 이는 영상의 질적 평가만 이루어진 것으로 환자의 피폭과 검사의 정밀도 및 정확도에 관한 연구가 추가로 필요한 실정이다. 추후 서로 다른 동위원소 사용에 따른 crosstalk contamination의 영향에 대한 정확하고 표준화된 유효성 검정으로 검사 간격에 대한 정확한 가이드라인 제시가 이루어져야 할 것이다.

  • PDF

중국 성인여성의 치수규격선정을 위한 체간부 체형분류 (Classification of Upper Body Types for the Establishment of a Size Standard for Chinese Women)

  • 장희경;손희순
    • 패션비즈니스
    • /
    • 제15권1호
    • /
    • pp.103-114
    • /
    • 2011
  • This study is to provide basic information on clothing fitness necessary to develop apparel products for Korean companies that want to enter or have already made inroads into the Chinese market. In an effort to serve this purpose, a standard upper torso body model for Chinese women was established by applying the Rohrer Index and Size Designation of Clothes - Women of GB/T 1335.2-1997 to Chinese women in their 20s to determine body types and its characteristics. First, according to the result of applying the Rohrer Index to categorize body types, Type 1 showed the longest vertical body length and a short horizontal length with the lowest degree of flatness. Type 2 was a standard body type with a height of 158.73cm, weight of 53.02kg and the Rohrer Index of 1.32. Type 3 had a thick and flat body shape that had the highest degree of flatness and the shortest vertical length in its upper torso among all three types of body. Second, F-test was conducted on 4 distinctive body types obtained from comparing obesity scores to verify differences in body shapes for different degree of obesity. The test result indicated significant differences in 3 of the 4 body types and showed different structural components for different degree of obesity. Third, the result of comparing correlational distributions of body types and height range, and body types and degree of obesity for all and specified age groups revealed that about 33.30% of the body types appeared in Type2-A followed by 20.18% in Type1-A, 18.40% in Type2-Y and 7.91% in Type1-Y respectively. Body types and degree of obesity for two different age groups were most frequent in Type2-A. For the group of young women in their early 20s appeared the most in Type2-A, Type1-A, Type2-Y and Type 1-Y respectively and young women in late 20s were frequent in the order of Type2-A, Type2-Y, Type1-A and Type1-Y.

양전자단층촬영(PET)시 환자의 특성에 따른 외부 방사선량률 측정 (Measuring external Radiation dose Ratio by Traits of Patients during Positron Emission Tomography(PET))

  • 조용귀;김성철;안성민
    • 한국콘텐츠학회논문지
    • /
    • 제13권12호
    • /
    • pp.860-868
    • /
    • 2013
  • PET/CT Torso를 위해 방사성의약품($^{18}F$-FDG) 투여 후 환자 개인의 특성에 따라 환자로부터 방출되는 외부 방사선량률을 여러 가지 방법으로 측정하여 방사선 선원으로부터 안전성을 확보하고, 경각심을 제공함으로서 방사선 노출에 의한 작업종사자와 환자 보호자, 수시출입자 등의 피폭선량을 저감하기 위함이다. 2013년1월에서 6월까지 PET Torso를 시행하는 환자들 중 80명을 대상으로 방사성의약품을 투여 후 환자의 체형(비만도), 수분 공급, 신장 상태, 방사성의약품 투여량에 따라 시간 변화에 의한 환자로부터 방출되는 외부 방사선량률을 각각 측정 하였다. 방사성의약품 투여 직후부터 환자 개인의 특성에 따라 외부 방사선량률을 측정한 결과 방사성의약품 투여량이 증가할수록 외부 방사선량률이 높았고, 환자 체형에 따른 외부 방사선량률은 유의한 차이가 없었다. 수분을 공급 했을 때와 신장이 정상일 때가 그렇지 않을 때 보다 외부 방사선량률이 낮았다. 방사선 안전관리를 준수하기 위하여 방사선 작업종사자는 선원을 취급하기 전 충분한 교육과 모의 훈련을 통해 작업시간을 최소화 할 수 있도록 노력해야 할 것이며, 개인 방사선 방호구를 착용하여 외부 방사선원으로부터 피폭을 최소화 시켜야 한다.

20대 남성 체형 특성에 따른 토르소 원형 개발 연구 (Development of Torso Pattern according to the Physical Types of Men in 20s)

  • 황은경;김인숙
    • 복식문화연구
    • /
    • 제12권3호
    • /
    • pp.415-428
    • /
    • 2004
  • The purpose of this thesis was to develop torso patterns according to the physical types of men in 20s. The procedure and results are as follows; 1. Of the men in 20s meeting the national average of physique, 4 men were selected and classified into 2 physical types according to their chest and waist circumference drops. One group had 20㎝ drop (Y type) while the other had 16㎝ drop (N type). Through evaluation performed by clothing construction professionals on the 4 upper bodice blocks drafted according to the existent drafting method and dressed on the 4 men, several problems have been found. These problems were adjusted and supplemented to make two new blocks. The fit of the new blocks were evaluated and proved to be satisfactory. 2. The following is the adjustments made to the existent men's torso patterns which had been utilized as the objects the first evaluation experiment. ① Though the back waist length of the pattern from the existent drafting method covered the center back length of the body in both Y type and N type, the front length did not causing it to stand away from the body. To adjust this, 2.0㎝ has been added to the center front length of each pattern so that the waist line could make a bar level to the ground. ② The shoulder line of the pattern from the existent drafting method had the tendency to fall backward. To make the shoulder line to fall in place, it has been moved 1.0㎝ to the front. 0.5㎝ has been added to the should length. ③ The neckline had a tendency to climb up. It has been lowered by 0.5㎝ until the line touched the center front neck point. ④ Though different in degree, the neck circumference did not allow enough width for both physique type causing the neckline to pull at side neck point with diagonal crease. To adjust this, 0.3㎝ and 0.6㎝ has been added to the Y type and N type respectively so that the neckline would touch the side neck point and the neckline could naturally fall into its original position. ⑤ Though different in degree, there was not enough space at the armhole causing wrinkles around this area. Therefore, 0.25㎝ and 0.5㎝ has been added to the front and back of the armholes of the Y and N types respectively. The armhole was made 1.0㎝ deeper only for the N type. ⑥ 1.0㎝ in the front and 0.5㎝ in the back were added to the side scam for the Y type while 0.5㎝ in the front and 0.25㎝ in the back were added for N type. This eliminated the unwanted wrinkles to give the silhouette a smooth look.

  • PDF

Tl-201을 이용한 심근관류 SPECT에서 Body contour와 Circular mode의 영상 획득 차이에 따른 영상의 질 비교 (The Comparison of Image Quality Using Body Contour and Circular Method with L-mode in Myocardial Perfusion SPECT)

  • 김성환;남기표;류재광;윤순상
    • 핵의학기술
    • /
    • 제16권1호
    • /
    • pp.3-7
    • /
    • 2012
  • 심근관류 SPECT의 영상획득 방법에는 Body contour와 Circular 방식이 있고, 환자와 검출기 사이의 거리를 줄이기 위해 Body contour 방식을 주로 사용한다. 그러나 이중(Dual) 검출기 장비에서 수직방식으로 검출기를 설정하여 영상을 획득하는 경우에는 환자와 검출기 사이의 거리가 Body contour 방식이 Circular 방식에 비해 더 증가하는 경향이 있다. 본 연구의 목적은 이중 검출기 장비에서 수직방식으로 검출기를 설정하여 영상을 획득하는 경우, Body contour 방식과 Circular 방식에서 환자와 검출기 사이의 거리를 비교하고, 거리에 따라 영상에 미치는 영향을 파악하여 영상의 질을 높이기 위한 방안을 제시하고자 시행하였다. 실험에 사용된 장비는 GE INFINIA Gamma Camera와 Anthropomorphic torso 모형에 심장 모형을 삽입하여 영상을 획득하였고, 2011년 8월 본원에서 심근관류 SPECT를 시행한 환자 40명을 대상으로 하였다. 모형 제작은 실제 환자조건과 동일하게 하기 위하여 심근에 74 kBq (0.22 mCi)/cc, 폐에 2.59 kBq ($60{\mu}Ci$)/cc, 연부조직에 11.1 kBq (2.2 mCi)/cc의 201-Tl을 주입하여 제작하였고, 영상획득 조건은 회전각 $6^{\circ}$, 50 sec/frame으로 환자와 동일한 조건으로 하였다. 영상획득 방식에 따른 차이를 확인하기 위해 Body contour와 Circular 방식으로 영상을 획득하여 환자와 검출기 사이의 거리를 각각 측정하여 비교하였고, 정상군과 비 정상군의 영상을 육안 분석하였다. 거리에 따라 영상에 미치는 영향을 확인하기 위해, 모형 실험에서 Circular 방식으로 회전반경을 18.8, 21.8, 23.8, 25.8, 28.8 cm 로 다르게 설정하여 영상을 획득하였고, 각 영상에서 심첨(Apex)에 관심영역을 설정하여 반치폭을 비교하였다. 모형 실험 결과, Body contour를 이용한 실험에서 산출된 반치폭은 6.23 mm이고, Circular mode에서 18.8, 21.8, 23.8, 25.8, 28.8 cm의 회전반경으로 산출된 반치폭은 각각 5.41, 6.24, 6.33, 6.42, 6.93 mm이다. 환자 데이터에서 Body contour의 회전반경이 -3.5 cm ~ 9.5 cm으로 차이를 보였고, Circular mode에 비해 평균 2.5 cm 더 큰 차이를 보였다. 본 연구를 통해, INFINIA 장비에서 Circular mode가 Body contour를 사용한 영상 획득 방법보다 낮은 반치폭을 보였다. 비록 INFINIA장비의 두 가지 영상 획득 방식에 대한 비교였지만, INFINIA장비를 이용한 심근관류 검사에서는 Circular mode 의 영상 획득 방식이 더 적합하다고 사료된다.

  • PDF

Simulated Annealing 기법을 이용한 인체 수직 전신 진동 모델의 파라미터 선정 (Mathematical Model Development of Whole-body Vertical Vibration, Using a Simulated Annealing Method)

  • 최준희;김영은;백광현
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2000년도 추계학술대회논문집A
    • /
    • pp.381-386
    • /
    • 2000
  • Simple spring-damper-mass models have been widely used to understand whole-body vertical biodynamic response characteristics of the seated vehicle driver. However, most previous models have not considered about the non-rigid masses(wobbling masses). A simple mechanical model of seated human body developed in this study included the torso represented by a rigid and a wobbling mass. Within the 0.5-20Hz frequency range and for excitation amplitudes maintained below $5ms^{-2}$, this 4-degree-of-freedom driver model is proposed to satisfy the measured vertical vibration response characteristics defined from a synthesis of published data for subjects seated erect without backrest support. The parameters are identified by using the combinatorial optimization technique, simulated annealing method. The model response was found to be provided a closer agreement with the response characteristics than previously published models.

  • PDF