• Title/Summary/Keyword: tor-generator

Search Result 8, Processing Time 0.018 seconds

ON TOR-TORSION THEORIES

  • GOLRIZ M.;BIJANZADEH M. H.
    • Communications of the Korean Mathematical Society
    • /
    • v.20 no.2
    • /
    • pp.209-219
    • /
    • 2005
  • Tor-torsion theory was defined by Jan Trlifaj in 2000. In this paper we introduce the notion of Co envelopes, CoCovers and Tor-generators as dual of envelopes, covers and generators in cotorsion(Ext-torsion) theory and deduce that each R-module has a projective and a cotorsion coprecover.

Key Findings from the Artist Project on Aerosol Retention in a Dry Steam Generator

  • Dehbi, Abdelouahab;Suckow, Detlef;Lind, Terttaliisa;Guentay, Salih;Danner, Steffen;Mukin, Roman
    • Nuclear Engineering and Technology
    • /
    • v.48 no.4
    • /
    • pp.870-880
    • /
    • 2016
  • A steam generator tube rupture (SGTR) event with a stuck-open safety relief valve constitutes one of the most serious accident sequences in pressurized water reactors (PWRs) because it may create an open path for radioactive aerosol release into the environment. The release may be mitigated by the deposition of fission product particles on a steam generator's (SG's) dry tubes and structures or by scrubbing in the secondary coolant. However, the absence of empirical data, the complexity of the geometry, and the controlling processes have, until recently, made any quantification of retention difficult to justify. As a result, past risk assessment studies typically took little or no credit for aerosol retention in SGTR sequences. To provide these missing data, the Paul Scherrer Institute (PSI) initiated the Aerosol Trapping In Steam GeneraTor (ARTIST) Project, which aimed to thoroughly investigate various aspects of aerosol removal in the secondary side of a breached steam generator. Between 2003 and 2011, the PSI has led the ARTIST Project, which involved intense collaboration between nearly 20 international partners. This summary paper presents key findings of experimental and analytical work conducted at the PSI within the ARTIST program.

A numerical study on the optimum size for the orifice located on the steam generator cassette of integral reactor (일체형원자로 증기발생기 카세트 하단에 설치된 오리피스의 최적설계 연구)

  • Kang Hyung Seok;Yoon Juhyeon;Kim Hwan Yeol;Cho Bong Hyun;Lee Doo Jeong
    • 한국전산유체공학회:학술대회논문집
    • /
    • 1998.05a
    • /
    • pp.75-81
    • /
    • 1998
  • A new advanced integral reactor of 330 MWt capacity named SMART(System-integrated Modular Advanced ReacTor) is currently under development at KAERI(Korea Atomic Energy Research Institute). One of the major design features of the integral reactor is locating the steam generators(SG) inside reactor vessel and eliminating the possibility of LB LOCA(large Break Loss of Coolant Accident). Orifices are fitted at the low part of steam generator cassette to stabilize and balance coolant flow distribution in the MCP (Main Circulation Pump) pressure header. A sensitivity analysis is conducted to determine the optimum orifice size using computer code 'CFX'.

  • PDF

Development of an Automatic Mesh-Generation Program in Irregular Domains (불규칙영역에서의 격자망 자동발생 프로그램의 개발)

  • 김성희;권순국
    • Magazine of the Korean Society of Agricultural Engineers
    • /
    • v.37 no.2
    • /
    • pp.21-30
    • /
    • 1995
  • In order to save time and efforts in generating finite element meshes in irregular houndaries of domains, it is needed to develop an automatic mesh-generator which can hoth promote the accuracy of solutions and reduce the run-time in operating finite ele- ment models. In this study, the advancing front technique of triangular mesh generation and the transforming technique from triangular meshes to quadrilateral meshes were used to de- velop a computer program for the automatic triangular and quadrilateral meshes in the mixed shape. Furthermore, to enhance the quadrilateral mesh quality, the techniques of Laplancian smoothing and interior mesh modification were employed. The mesh genera- tor was applied to evaluate its applicability to irregular and complex geometries such as Nakdong river bay. In has hoen shown that the automatic mesh generator developed is capable of automatically generating meshes for irreguiar and complex geometries with high qualities of meshes and with the simple input data of arbitrarily specified nodal spacing in bound- aries.

  • PDF

Development of a computer code for thermal-hydraulic design and analysis of helically coiled tube once-through steam generator

  • Zhang, Yaoli;Wang, Duo;Lin, Jianshu;Hao, Junwei
    • Nuclear Engineering and Technology
    • /
    • v.49 no.7
    • /
    • pp.1388-1395
    • /
    • 2017
  • The Helically coiled tube Once-Through Steam Generator (H-OTSG) is a key piece of equipment for compact small reactors. The present study developed and verified a thermal-hydraulic design and performance analysis computer code for a countercurrent H-OTSG installed in a small pressurized water reactor. The H-OTSG is represented by one characteristic tube in the model. The secondary side of the H-OTSG is divided into single-phase liquid region, nucleate boiling region, postdryout region, and single-phase vapor region. Different heat transfer correlations and pressure drop correlations are reviewed and applied. To benchmark the developed physical models and the computer code, H-OTSGs developed in Marine Reactor X and System-integrated Modular Advanced ReacTor are simulated by the code, and the results are compared with the design data. The overall characteristics of heat transfer area, temperature distributions, and pressure drops calculated by the code showed general agreement with the published data. The thermal-hydraulic characteristics of a typical countercurrent H-OTSG are analyzed. It is demonstrated that the code can be utilized for design and performance analysis of an H-OTSG.

A Sensitivity Study of a Steam Generator Tube Rupture for the SMART-P (SMART 연구로의 증기발생기 전열관 파열사고 민감도 분석)

  • Kim Hee-Kyung;Chung Young-Jong;Yang Soo-Hyung;Kim Hee-Cheol;Zee Sung Quun
    • Journal of the Korean Society of Safety
    • /
    • v.20 no.2 s.70
    • /
    • pp.32-37
    • /
    • 2005
  • The purpose of this study is for the sensitivity study f9r a Steam Generator Tube Rupture (SGTR) of the System-integrated Modular Advanced ReacTor for a Pilot (SMART-P) plant. The thermal hydraulic analysis of a SGIR for the Limiting Conditions for Operation (LCO) is performed using TASS/SMR code. The TASS/SMR code can calculate the core power, pressure, flow, temperature and other values of the primary and secondary system for the various initiating conditions. The major concern of this sensitivity study is not the minimum Critical Heat Flux Ratio(CHFR) but the maximum leakage amount from the primary to secondary sides at the steam generator. Therefore the break area causing the maximum accumulated break flow is researched for this reason. In the case of a SGIR for the SMART-p, the total integrated break flow is 11,740kg in the worst case scenario, the minimum CHFR is maintained at Over 1.3 and the hottest fuel rod temperature is below 606"I during the transient. It means that the integrity of the fuel rod is guaranteed. The reactor coolant system and the secondary system pressures are maintained below 18.7MPa, which is system design pressure.

A Study on the Removing Method of Hunting by Equalizing Line during Parallel Running of alternator Equipped with converter (컨버터가 내장된 교류발전기 병렬운전중의 헌팅을 균압선을 이용해 제거하는 방법에 관한 연구)

  • 노창주
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.23 no.3
    • /
    • pp.352-359
    • /
    • 1999
  • This paper is a research for removing the alternators hunting which came about during the par-allel running. The four-pole six-phase alternator is equipped with the converter made out of twelve diodes to rectify all the waves. The hunting came about during the battery charging due to the hunting inducing point existed in r. p. m band 1575[rpm-1690[rpm] To remove the hunting inducing point We modified the four-pole six-phase alternator into the four-pole twevel-phase and increased the short-circuit ratio by decreasing the field coil pitch and increasing the field coil turns. But this method has two defects the first the alternator structure becomes complicating and the second the second the alternator equipped with the converter used in general purpose lately such as the car alternator can not be run in parallel wlthout modifying. To remove the defects the equalizing line was connected between the same phase of the alterna-tor to flow the synchronizing current which syncronize the phases of generator electromotive forces by which the alternator can be run in parallel without reference to the hunting inducing point and without modifying.

  • PDF

Experimental Study on Design Verification of New Concept for Integral Reactor Safety System (일체형원자로의 신개념 안전계통 실증을 위한 실험적 연구)

  • Chung, Moon-Ki;Choi, Ki-Yong;Park, Hyun-Sik;Cho, Seok;Park, Choon-Kyung;Lee, Sung-Jae;Song, Chul-Hwa
    • Proceedings of the KSME Conference
    • /
    • 2004.04a
    • /
    • pp.2053-2058
    • /
    • 2004
  • The pressurized light water cooled, medium power (330 MWt) SMART (System-integrated Modular Advanced ReacTor) has been under development at KAERI for a dual purpose : seawater desalination and electricity generation. The SMART design verification phase was followed to conduct various separate effects tests and comprehensive integral effect tests. The high temperature / high pressure thermal-hydraulic test facility, VISTA(Experimental Verification by Integral Simulation of Transient and Accidents) has been constructed to simulate the SMART-P (the one fifth scaled pilot plant) by KAERI. Experimental tests have been performed to investigate the thermal-hydraulic dynamic characteristics of the primary and the secondary systems. Heat transfer characteristics and natural circulation performance of the PRHRS (Passive Residual Heat Removal System) of SMART-P were also investigated using the VISTA facility. The coolant flows steadily in the natural circulation loop which is composed of the steam generator (SG) primary side, the secondary system, and the PRHRS. The heat transfers through the PRHRS heat exchanger and ECT are sufficient enough to enable the natural circulation of the coolant.

  • PDF