• 제목/요약/키워드: topographies

검색결과 85건 처리시간 0.164초

임플란트의 표면처리 유형에 따른 골 치유 양상 (Bone Healing around Screw - shaped Titanium Implants with Three Different Surface Topographies)

  • 고영한;김영준;정현주
    • Journal of Periodontal and Implant Science
    • /
    • 제31권1호
    • /
    • pp.41-57
    • /
    • 2001
  • It is well known that the apposition of bone at implant surface would be influenced by the microstructure of titanium implants. The purpose of this study was to compare bone healing around the screw-shaped titanium implant with three different surface topographies in the canine mandibles by histological and biomechanical evaluation. All mandibular premolars of six mongrel dogs were extracted and implants were placed one month later. The pure titanium implants had different surface topographies: smooth and machined ($Steri-OSS^{(R)}$: Group II); sandblasted and acid-etched ($ITI^{(R)}$, SLA: Group III) surface. The fluorescent dyes were injected on the 2nd (calcein), 4th (oxytetracycline HCI) and 12th (alizarin red) weeks of healing. Dogs were sacrificed at 4 and 12 weeks after implantation. The decalcified and undecalcified specimens were prepared for histological and histo-metrical evaluation of implant-bone contact. Some specimens at 12 weeks after implantation were used for removal torque testing. Histologically, direct bone apposition to implant surface was found in all of the treated groups. More mature and dense bone was observed at the implant-bone interface at 12 weeks than that at 4 weeks after implantation. Under the fluorescent microscope, thick regular green fluorescent lines which mean early bone apposition were observed at the implant-bone interface in Group III, while yellow and red fluorescent areas were found at the implant-bone interface in Group I and II. The average implant-bone contact ratios at 4 weeks of healing were 54.3% in Group I, 57.7% in Group II and 66.2% in Group III. In Group I, implant-bone contact ratio was significantly lower than Group II and III(p<0.05). The average implant-to-bone contact ratios at 12 weeks after implantation were 64.3% in Group I, 66.7% in Group II and 71.2% in Group III. There was no significant difference among the three groups. In Group I and II, the implant-bone contact ratio at 12 weeks increased significantly in comparison to ratio at 4 weeks(p<0.05). The removal torque values at 12 weeks after implantation were 90.9 Ncm in Group I, 81.6 Ncm in Group II and 77.1 Ncm in Group III, which were significantly different(p<0.05). These results suggest that bone healing begin earlier and be better around the surface-treated implants compared to the smooth surface implants. The sandblasted and acid-etched implants showed the most favorable bone response among the three groups during the early healing stage and could reduce the waiting period prior to implant loading.

  • PDF

선삭에서의 가공 표면 제어 (ENGINEERED SURFACE CONTROL IN TURNING PROCESS)

  • 홍민성
    • 한국생산제조학회지
    • /
    • 제4권3호
    • /
    • pp.48-57
    • /
    • 1995
  • The feasibility of generating controller surface topographies in single-point conventional turning operations is investigated. First, a mathematical model of the surface generation process was developed. Second, in order to control the texture of the machined surface, a micro-positioning stage and the associated command generation software were designed and built. Experimental examples have shown that surface texture can be precisely controlled and is in good agrement with the theoretical predictions.

  • PDF

Carbide분말상의 무전해 도금 (Electroless Deposition on Carbide Powders)

  • 이창언;최순돈
    • 한국표면공학회지
    • /
    • 제28권1호
    • /
    • pp.3-13
    • /
    • 1995
  • Electroless Ni and Cu platings were conducted on $B_4C$ and SiC. In the electroless Ni plating, the deposition rate on $B_4C$ was higher than on SiC. However, the electroless Cu deposition occured with high deposition rate regardless of the carbide substrates used in this study. Uniformity of the deposits was better in the electroless Cu deposition than in the electroless Ni deposition. In the topographies of the electroless depositions, Ni deposits have grown as colony, whereas Cu deposits have grown as fine individual grains.

  • PDF

ENGINEERED SURFACE CONTROL IN TURNING PROCESS

  • 홍민성
    • 한국공작기계학회:학술대회논문집
    • /
    • 한국공작기계학회 1995년도 춘계학술대회 논문집
    • /
    • pp.24-33
    • /
    • 1995
  • The feasibility of generating controlled surface topographies in single-point conventional turning operations is investigated. First a mathematical model of the surface generation process was developed. Second in order to control the texture of the machined surface a micro-positioning stage and the associated command generation software were designed and built. Experimental examples have shown that surface texture can be precisely controlled and is in good agreement with the theoretical predictions.

  • PDF

Comparion of stability in titanium implants with different surface topographies in dogs

  • Kim, Nam-Sook;Vang, Mong-Sook;Yang, Hong-So;Park, Sang-Won;Park, Ha-Ok;Lim, Hyun-Pil
    • The Journal of Advanced Prosthodontics
    • /
    • 제1권1호
    • /
    • pp.47-55
    • /
    • 2009
  • STATEMENT OF PROBLEM. A few of studies which compared and continuously measured the stability of various surface treated implants in the same individual had been performed. PURPOSE. We aim to find the clinical significance of surface treatments by observing the differences in the stabilization stages of implant stability. MATERIAL AND METHODS. Eight different surface topographies of dental implants were especially designed for the present study. Machined surface implants were used as a control group. 4 nano-treated surface implants(20 nm $TiO_2$ coating surface, heat-treated 80 nm $TiO_2$ coating surface, CaP coating surface, heat treated CaP coating surface) and 3 micro-treated surface implants [resorbable blast media(RBM) surface, sandblast and acid-etched(SAE) surface, anodized RBM surface] were used as experiment groups. All 24 implants were placed in 3 adult dogs. $Periotest^{(R)}$ & ISQ values measured for 8 weeks and all animals were sacrificed at 8 weeks after surgery. Then the histological analyses were done. RESULTS. In PTV, all implants were stabilized except 1 failed implants. In ISQ values, The lowest stability was observed at different times for each individual. The ISQ values were showed increased tendency after 5 weeks in every groups. After 4 to 5 weeks, the values were stabilized. There was no statistical correlation between the ISQ values and PTV. In the histological findings, the bone formation was observed to be adequate in general and no differences among the 8 surface treated implants. CONCLUSIONS. In this study, the difference in the stability of the implants was determined not by the differences in the surface treatment but by the individual specificity.

양빈 후 지형변화에 따른 해운대 이안류 수치모의 (A numerical study on rip currents at the Haeundae coast changed after the beach nourishment)

  • 최준우
    • 한국수자원학회논문집
    • /
    • 제55권9호
    • /
    • pp.669-678
    • /
    • 2022
  • 연안정비사업으로 추진된 해운대 해수욕장의 대규모 양빈(2013~2015)으로 해운대 해변의 해안선 및 수심지형에 급한 인위적 변동이 있었다. 기존 연구에서는 양빈 직, 전후의 수심지형을 입력 조건으로 Boussinesq 방정식 모형인 FUNWAVE를 이용하여 수치모의를 수행, 수심지형 변화에 따른 이안류 발생 특성을 분석하였다. 양빈 직후 쇄파대 폭의 감소로 이안류의 강도 및 발생정도가 감소하였다. 본 연구에서는 대규모 양빈 후 수년이 지난 2017년 및 2020년에 다시 측량된 수심지형을 이용하여 동일한 조건으로 수치모의를 수행하여 결과를 제시하였다. 그리고 양빈 전 및 직후, 그리고 수년이 지난 후의 해운대 이안류를 비교하였다. 시간이 지남에 따라 단면경사가 완만해 지고 쇄패대 폭이 증가되어 이안류의 강도와 발생정도가 다시 증가하고 있다고 판단된다.

휴대폰 카메라용 비구면 Glass 렌즈 전사특성 분석 (Transcription Characteristics in the Molding of Aspheric Glass Lenses for Camera Phone Module)

  • 차두환;이준기;김민제;이동길;김혜정;김정호
    • 한국소성가공학회:학술대회논문집
    • /
    • 한국소성가공학회 2008년도 추계학술대회 논문집
    • /
    • pp.363-366
    • /
    • 2008
  • The transcription characteristics in the molding of aspheric glass lenses for camera phone modules have been investigated experimentally. The surface topographies of both the form and the roughness were compared between the mold and the molded lens. The molded lens showed a transcription ratio of 93.4%, which is obtained by comparing the form accuracy (PV) values of the mold and the molded lens. The transcription of the roughness topography was ascertained by bearing ratio analysis.

  • PDF

Fabrication of Protein A-Viologen Hetero LB Film for Antibody Immobilization

  • 이헌주;최정우;이우창;오병근;이원홍
    • 한국생물공학회:학술대회논문집
    • /
    • 한국생물공학회 2001년도 추계학술발표대회
    • /
    • pp.859-862
    • /
    • 2001
  • For the development of preferable immunosensor and protein chip, the viologen Langmuir-Blodgett (LB) multilayer was fabricated on the surface, and then protein A was adsorbed on the proposed viologen LB film by electrostatic attractive force. The Immunoglobulin G (IgG) labeled with fluorescence marker was self-assembled on the fabricated protein A film. The topographies of the deposited films were investigated by using atomic force microscope (AFM). The immobilization of IgG was verified by fluorescence spectrum. Such structures can be used as sublayers for various kinds of IgG immobilization toward immunosensors and protein chip.

  • PDF

A STUDY ON THE CALCULATING THE AMOUNT OF UPDATING DIGITAL MAP USING REMOTELY SENSED DATA

  • Yoon Yeo-Sang;Cho Hong-Beom;Kang In-Gu
    • 대한원격탐사학회:학술대회논문집
    • /
    • 대한원격탐사학회 2005년도 Proceedings of ISRS 2005
    • /
    • pp.272-275
    • /
    • 2005
  • The digital map expresses natural topographies and artificial things with 3D position coordinates in the computer such as the road, railway, building, river, mountain, paddy and dryland. Therefore, the digital map is regarded as an important factor in the information-oriented society. However, it is difficult to maintain the most recent topographic information all the times because of restricted budget and time. For that, the efficient method corresponded with the digital map should be presented. This study aims to suggest the way to make an estimate of updating cost for 1:5,000 scale digital map by using remotely sensed data. To predict updating area of the digital map, the screen digitizing method was applied to the overlapped images and digital maps.

  • PDF

휴대폰 카메라용 비구면 Glass렌즈 전사특성 분석 (Transcription Characteristics in the Molding of Aspheric Glass Lenses for Camera Phone Module)

  • 차두환;김혜정;김정호
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2008년도 추계학술대회 논문집 Vol.21
    • /
    • pp.336-336
    • /
    • 2008
  • The transcription characteristics in the molding of aspheric glass lenses for camera phone modules have been investigated experimentally. The surface topographies of both the form and the roughness were compared between the mold and the molded lens. The molded lens showed a transcription ratio of 93.4%, which is obtained bycomparing the form accuracy (PV) values of the mold and the molded lens. The transcription of the roughness topography was ascertained by bearing ratio analysis.

  • PDF