• Title/Summary/Keyword: tooth shade

Search Result 81, Processing Time 0.029 seconds

Natural Tooth Color Evaluation in the Korean Elderly Population

  • Bye-Ri Han;Mi-Yeon Kim;Sun-Ho Kim;Jeong-Hee Kim;Ran-Ah Kim
    • Journal of Korean Dental Science
    • /
    • v.16 no.2
    • /
    • pp.192-203
    • /
    • 2023
  • Purpose: This study is to investigate the distribution of natural tooth shades in the Korean elderly population to quantify the correlation and changes of tooth color with age and gender. In addition, the possible effects of habits on tooth color were assessed. Materials and Methods: The tooth color of one of the maxillary central incisors of 200 Korean individuals aged 50 to 89 years, males and female, was measured using the portable intraoral spectrophotometer (VITA Easyshade V). CIELab and CIELCh color coordinates were recorded. We conducted the survey about the tobacco smoking, chronic disease, medication, eating habits, oral health behaviors and satisfaction with tooth color. Experimental data were statistically analyzed by using the t-test (P<0.05), two-way analysis of variance and Pearson's correlation test. Result: The most frequent color in the Korean elderly population was 3M3 & A3.5 shade. L* and h* values decreased, whereas C*, a* and b* values increased progressively with age. There was a significant interaction between age and color coordinates for b* values (r=0.245, P<0.05). Males generally have significantly higher C*, a*, b* values and lower L*, h* value compared to females. Individuals who consumed alcohol had a higher L* value (P<0.05). Conclusion: Within the limitation of this study, the central incisors were getting darker, more reddish, and yellowish with age. Information on the chromatic range of natural teeth by age and gender could help to select colors for esthetic dental restorations.

Shade Comparative Analysis of Natural tooth Measured by Visual and Two Colorimeters(ShadeEye®,Shadepilot®) (2종 측색기와 시각을 이용한 자연치아의 색조 비교 분석)

  • An, Jin-Hee;Choi, Mee-Ra;Shim, Hye-Won
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.29 no.1
    • /
    • pp.81-93
    • /
    • 2013
  • The objectives were to evaluate the accuracy of shade selection by human visual system(VS) and 2 different colorimeters ($ShadeEye^{(R)}$(SE) and Shadepilot (SP)). Maxillary anterior teeth of 30 volunteers which had no caries or restorations were included in the study. Firstly, the accordance in shade selection by 3 dentists and 2 colorimeters was investigated. Secondly, the color of the teeth were measured by 1 observer's naked eye and 2 colorimeters under different illumination conditions (Sunny versus cloudy day). Additionally testing of inter-observer variability selected colors by 2 novice and 2 experienced dentists were compared. For comparing visual and 2 different colorimeters, SP(60%) showed significantly highest rate of accordance than the visual (23.3%) or SE (16.7%) and lowest mean ${\Delta}E$ ($2.62{\pm}0.74$ versus $3.83{\pm}1.38$;SE or $4.04{\pm}1.61$;VS)(p<0.001). If accuracy of shade selection were measured using VS, the mean ${\Delta}E$ value of cloudy day was higher than that of sunny day ($4.35{\pm}1.70$ versus $3.53{\pm}1.31$; p<0.001). There were no significant difference of the mean ${\Delta}E$ value between sunny and cloudy day in both SE and SP. Inter- observer repeatability was higher in 2 experienced group (73.3%) than novice group (36.7%). The mean ${\Delta}E$ of experienced group was lower than that of novice group ($3.60{\pm}1.47$ versus $4.70{\pm}1.67$; p<0.001). Colorimeters (SE or SP) is more accurate and more reproducible compared with human shade assessment. Using visual system may be limited by cloudy and inexperience of tester, then more experience and using colorimeters may be helpful of raising the accurate repeatability of shade selection.

A CLINICAL EVALUATION OF A BLEACHING STRIP CONTAINING 2.9% HYDROGEN PEROXIDE (2.9% 과산화수소를 함유한 부착형 미백제의 임상적 효능과 안전성에 관한 연구)

  • Park Eun-Sook;Seong So-Rae;Hong Seong-Tae;Kim Ji-Eun;Lee So-Young;Hwang Soo-Youn;Lee Shin-Jae;Jin Bo-Hyoung;Son Ho-Hyun;Cho Byeong-Hoon
    • Restorative Dentistry and Endodontics
    • /
    • v.31 no.4
    • /
    • pp.269-281
    • /
    • 2006
  • This study evaluated the effectiveness and safety of an experimental bleaching strip (Medison dental whitening strip. Samsung medical Co., Anyang, Korea) containing 2.9% hydrogen peroxide. Twenty-three volunteers used the bleaching strips for one and a half hour daily for 2 weeks. As control group. the same strips in which hydrogen peroxide was not included were used by 24 volunteers with the same protocol. The shade change (${\Delta}E^{*}$, color difference) of twelve anterior teeth was measured using Shade Vision (X-Rite Inc., S.W. Grandville, MI, USA). Chroma Meter (Minolta Co., Ltd. Osaka. Japan) and Vitapan classical shade guide (Vita Zahnfabrik, Germany). The shade change of overall teeth in the experimental group was significantly greater than that in the control group (p < 0.05) and was easily perceivable. The change resulted from the increase of lightness (CIE $L^{*}$ value) and the decrease of redness (CIE $a^{*}$ value) and yellowness (CIE $b^{*}$ value). The shade change of individual tooth was greatest in canine. and smallest in central incisor. The safety of the bleaching strip was also confirmed.

Tooth whitening maintenance efficacy of dentifrices containing several active ingredients in vitro and in vivo (유효성분들을 배합한 치약제의 실험실적 및 임상적 치아미백유지 효과)

  • Ahn, Jae-Hyun;Kim, Ji-Hye;Kim, Jong-Hoon
    • Journal of Korean society of Dental Hygiene
    • /
    • v.15 no.2
    • /
    • pp.325-332
    • /
    • 2015
  • Objectives: The purpose of this study was to investigate tooth whitening maintenance efficacy of several dentifrices containing effective ingredients for tooth whitening. Methods: Hydroxyapatite specimens(HAPs) staining was done by using modified Stookey's methods. HAPs were treated with 2.9% hydrogen peroxide containing strip for whitening, and were shaken with several dentifrice slurry(dentifrice 1 : artificial saliva 2) for 30 minutes. The HAPs were finally dipped in staining solution for an hour. Shaking and dipping were repeated 4 times and lightness values were measured by colorimeter at each step. In clinical test, test 4 dentifrice and control dentifrice were evaluated by 21 subjects for 2 months after receiving institutional review board(IRB) approval. Organoleptic(vita shade guide) and instrumental(SHADEEYE-NCC) evaluation were performed for whiteness change of teeth. Statistical analysis was performed using repeated measures ANOVA, Tukey's post hoc test and ${\chi}^2$-test(p<0.05). Results: All dentifrices showed statistical significance in comparison with control dentifrice containing sodium fluoride and test 4 dentifrice containing sodium pyrophosphate, sodium metaphosphate, candelilla wax, and sodium fluoride showed statistical significance in comparison with other dentifrices by inhibiting staining in vitro(p<0.05). In clinical test, test 4 dentifrice showed better effects than control dentifrice in organoleptic and instrumental evaluation in tooth whitening maintenance efficacy(p<0.05). The awareness toward tooth whitening maintenance efficacy for 2 months use showed that test 4 dentifrice was much better than control dentifrice, but did not show statistically significant(p>0.05). Conclusions: Dentifrice containing sodium pyrophosphate, sodium metaphosphate, candelilla wax and sodium fluoride was more effective in keeping teeth white.

Evaluation of the Color Adjustment Potential of Single-Shade Composite Resin in Primary Teeth (유치에서의 단일 색조 복합레진의 색조 적응력 평가)

  • Yongsoon Kim;Howon Park;Juhyun Lee;Haeni Kim
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.50 no.1
    • /
    • pp.113-120
    • /
    • 2023
  • Restoring composite resins with the optimal shades for all primary teeth is a great challenge for pediatric dentists. A newly developed single-shade composite resin can exhibit a color similar to that of the surrounding tooth structure based on the structural color phenomenon. This study aims to evaluate the color adjustment potential (CAP) of a single-shade composite resin compared to conventional multi-shade composite resins in primary teeth. A single-shade composite resin and two conventional multi-shade composite resins were included in this study. Two types of specimens, a single specimen and a dual specimen, were evaluated. For single specimens, duplications of the primary second molar denture teeth were made using experimental composite resins. For dual specimens, cavities were prepared on the buccal surfaces of extracted primary second molars and restored with experimental composite resins. The L*, a*, and b* values were measured using a colorimeter for the extracted teeth and specimens. The mean ΔEab* values for single and dual specimens and CAP were calculated. Bonferroni post-hoc analysis was performed to confirm the statistical significance between the ΔEab* and CAP values of the experimental resins. Among the single specimens, the single-shade composite resin showed significantly higher ΔESingle compared to other composite resins (p < 0.0167). There was no significant difference between ΔEDual for all experimental resins. The single-shade composite resin showed highest CAP compared to other multi-shade composite resins. A single-shade composite resin exhibited the most prominent color adaptability compared to other conventional multi-shade composite resins for primary second molars. A single-shade composite resin can simplify shade matching and provide esthetic outcomes for the restoration of primary second molars.

INFLUENCE OF SEVERAL POSTS AND IPS-EMPRESS INGOT THICKNESS ON THE FINAL SHADE OF ALL-CERAMIC CROWNS (수종의 post와 IPS-Empress Ingot 두께가 전부 도재 수복물 최종색조에 미치는 영향)

  • Bok Won-Mi;Choi Keun-Bae;Park Charn-Woon;Ahn Seung-Geun
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.42 no.5
    • /
    • pp.514-523
    • /
    • 2004
  • Statement of problem: All-ceramic restorations have been advocated for superior esthetics. Various post and core systems have been used to improve the strength of damaged teeth, but it is unclear whether they affect the final shade of finished all-ceramic restorations. Purpose: The influence of different types of post and core systems on light transmission through all-ceramic crowns was assessed by spectrophotometric analysis. Also the masking effect of different thickness of ceramic ingot was evaluated. Material and Methods : Forty-five sample disks (15mm in diameter) at several thickness(1.0, 1.5, 2.0mm) and value(shade 100, 200, 300) were made in heat pressed ceramic(IPS-Empress). Background specimens simulating gold-alloy cast posts(Type III casting gold alloy), metal posts(Ni-Cr casting alloy) and ceramic posts(CosmoPost) were fabrica-ted. Resin composite(Z250, A3 shade) was used as a tooth substrate reference. For each combination, the change in color was measured with a spectrophotometer. Readings were performed for 2 conditions (1) ability of ceramic to mask the core in relation to its thickness(1.0, 1.5, or 2.0mm) ; (2) influence of post and core types on the final color of the ceramic. Data were recorded according to the CIE $L^*a^*b^*$ systems and color difference($\Delta$E) was calculated. Results: 100 shade ingot: when ceramic thickness was 1.0mm, $\Delta$E value for ceramic post larger than 1 but $\Delta$E value for metal and gold post was larger than 2. For ceramic thickness of 1.5mm, only $\Delta$E value for metal was larger than 2, and the other samples' $\Delta$E value was smaller than 2. For ceramic thickness of 2.0mm, $\Delta$E values for all specimens was smaller than 2. 200 shade ingot: when ceramic thickness was 1.0mm, $\Delta$E value for ceramic post was smaller than 1 but $\Delta$E value for metal and gold post was larger than 2. For ceramic thickness of 1.5 mm, only the $\Delta$E value for metal was larger than 2, and the other samples' $\Delta$E value was smaller than 2. For ceramic thickness of 2.0mm, $\Delta$E values for all specimens was smaller than 1. 300 shade ingot: when ceramic thickness was 1.0mm, only $\Delta$E value for metal was larger than 2 and the other samples' $\Delta$E value was smaller than 2. For ceramic thickness of 1.5mm, $\Delta$E values for all specimens was smaller than 1. For ceramic thickness of 2.0mm, $\Delta$E values for all specimens was smaller than 1. Conclusion: The final esthetic result of the IPS-Empress glass-ceramic restoration was not affected by the presence of different core materials when the thickness was more than 2.0 mm. When ceramic thickness decreases to 1.5mm, it is advised to take the substrate aspects into consideration. If the ceramic thickness is less than 1.0mm, using the tooth color matched substrate is strongly recommended.

CEREC 3D System을 이용한 당일수복 (one-day treatment) 임상증례

  • Jeong, Hyo-Gyeong
    • Journal of the Korean Academy of Esthetic Dentistry
    • /
    • v.17 no.1
    • /
    • pp.23-30
    • /
    • 2008
  • Application of CAD/CAM is changing the way partial or full veneer all ceramic restoration is made. CAD/CAM systems, which were used mainly in other industries, have been developed and introduced for the dental purposes recently. It produced a flood of information on the CAD/CAM systems. It also influenced the development of restorative materials and all ceramic is substituting the traditional restorative materials of gold, composite resin and metal. Price increase of gold and other raw materials made the all ceramic more appealing. The introduction of a CEREC 3D system was innovative in several ways. Image of the prepared tooth is captured by camera and impression taking is unnecessary. Restoration can be delivered to the patient on one appointment and it will satisfy the demand of busy patients. One-day treatment with direct CAD/CAM system saves time compared to indirect CAD/CAM system. More superior restoration can be produced if lab work such as the adaptability check and shade selection is cooperated with lab technician. Short working time and comparably superior shade compatibility of color block was close to ideal. In the future, restorations with better quality can be fabricated in less time to busy patients thanks to the development of CAD/CAM system and dental materials.

  • PDF

Shade Comparative Analysis of Natural Tooth using Spectrophotometric Methods (분광측정기를 이용한 자연 치아의 색조 비교 분석)

  • Kim, Sa-Hak;Hwang, Seong-Sig;Lee, Hye-Eun
    • The Journal of the Korea Contents Association
    • /
    • v.16 no.2
    • /
    • pp.772-781
    • /
    • 2016
  • This study is to set the objective criteria on maxillary incisors shade selection by using the colorimetric Shade-Eye NCC as measuring in CIE $L^*$, $a^*$, $b^*$ values, and look into the meaning by analyzing its values. We explain the purpose of this study and gotten their agreement from patients visiting the dentist, 111 people's (men 50, women 61) three teeth, the maxillary central incisor, maxillary lateral incisor, maxillary canines, total of 333 teeth colorimetry. As a result of comparing the differences in colors between cervical margin and incisal edge, ${\Delta}E^*$ of canine is shown as low as $5.81({\pm}2.98)$, followed by lateral incisor of maxilla as $6.51({\pm}3.23)$ and central incisor of maxilla $7.51({\pm}3.04)$. Females show higher luminosity(L*) than males do in all teeth- central incisor, lateral incisor and canine; in yello chroma(b*) males' central incisor is slightly higher than that of females (p<0.05). Age significantly influences the luminosity and red (a*) and yellow chroma (b*) of central incisor(L*); the luminosity(L*), and yellow chroma(b*) of lateral incisor and canine (p<0.05). Smoking doesn't significantly influence the color of natural teeth. Drinking reduces the luminosity of central incisor as well as red chroma of lateral incisor(p<0.05). A chronic illness is likely to reduce the luminosity of central incisor and lateral incisor(p<0.05).

CLINICAL STUDY OF SHADE IMPROVEMENT AND SAFETY OF POLYMER-BASED PEN TYPE BlancTis Forte WHITENING AGENT CONTAINING 8.3% CARBAMIDE PEROXIDE (8.3% Carbamide Peroxide 함유 펜 형 자가미백제인 BlancTis Forte의 색조개선 및 안전성에 관한 임상연구)

  • Lee, Jin-Kyung;Min, Sun-Hong;Hong, Sung-Tae;Oh, So-Ram;Chung, Shin-Hye;Hwang, Young-Hye;You, Sung-Yeop;Bae, Kwang-Shik;Baek, Seung-Ho;Lee, Woo-Cheol;Son, Won-Jun;Kum, Kee-Yeon
    • Restorative Dentistry and Endodontics
    • /
    • v.34 no.2
    • /
    • pp.154-161
    • /
    • 2009
  • This clinical study evaluated the whitening effect and safety of polymer based-pen type BlancTis Forte (NIBEC) containing 8.3% carbamide peroxide. Twenty volunteers used the BlancTis Forte whitening agent for 2 hours twice a day for 4 weeks. As a control. Whitening Effect Pen (LG) containing 3% hydrogen peroxide was used by 20 volunteers using the same protocol. The change in shade (${\Delta}E^*$, color difference) was measured using $Shadepilot^{TM}$ (DeguDent) before, during, and after bleaching (2 weeks, 4 weeks, and post-bleaching 4 weeks). A clinical examination for any side effects (tooth hypersensitivity or soft tissue complications) was also performed at each check-up. The following results were obtained. 1. Both the experimental and control groups displayed a noticeable change in shade (${\Delta}E$) of over 2. No significant differences were found between the two groups (p > 0.05), implying that the two agents have a similar whitening effect.2. The whitening effect was mainly due to changes in a and b values rather than in L value (brightness). The experimental group showed a significantly higher change in b value, thus yellow shade, than the control (p < 0.05). 3. None of the participants complained of tooth hypersensitivity or soft tissue complications, confirming the safety of both whitening agents.

A GEOMETRIC STANDARDIZATION OF PERIAPICAL INTRAORAL RADIOGRAPHY (구내 표준 방사선 사진촬영의 위치 표준화)

  • Choi Bong-In;Nah Kyung-Soo
    • Journal of Korean Academy of Oral and Maxillofacial Radiology
    • /
    • v.21 no.2
    • /
    • pp.415-423
    • /
    • 1991
  • This study was performed to evaluate the geometric standardization of periapical intraoral radiography. Image distortion was measured by analysing serial radiography obtained from dry skull using 5 types of bite registration device. After 16 weeks, the angular distortion of Pattern resin was 0.26±0.14 degree(Horizontal angle 0.17±0.14, Vertical angle 0.16±0.11) which was the lowest among the 5 registration device, and that of putty type Exaflex was 0.49±0.35 degree(Horizontal angle 0.42±0.35, Vertical angle 0.17±0.13) which was the highest. The mean amount of distortion variance of Tooth shade acrylic at each experimental period was 0.06±0.08 which was the lowest among the 5 registration device, and that of XCP alone was 0.ll±0.13 which was the highest.

  • PDF