• 제목/요약/키워드: tooth shade

검색결과 81건 처리시간 0.028초

Esthetic rehabilitation of single anterior edentulous space using fiber-reinforced composite

  • Kim, Hyeon;Song, Min-Ju;Shin, Su-Jung;Lee, Yoon;Park, Jeong-Won
    • Restorative Dentistry and Endodontics
    • /
    • 제39권3호
    • /
    • pp.220-225
    • /
    • 2014
  • A fiber-reinforced composite (FRC) fixed prosthesis is an innovative alternative to a traditional metal restoration, as it is a conservative treatment method. This case report demonstrates a detailed procedure for restoring a missing anterior tooth with an FRC. A 44-year-old woman visited our department with an avulsed tooth that had fallen out on the previous day and was completely dry. This tooth was replanted, but it failed after one year. A semi-direct technique was used to fabricate a FRC fixed partial prosthesis for its replacement. The FRC framework and the pontic were fabricated using a duplicated cast model and nanofilled composite resin. Later on, interproximal contact, tooth shape, and shade were adjusted at chairside. This technique not only enables the clinician to replace a missing tooth immediately after extraction for minimizing esthetic problems, but it also decreases both tooth reduction and cost.

Evaluation of the repeatability and matching accuracy between two identical intraoral spectrophotometers: an in vivo and in vitro study

  • Kim, Hee-Kyung
    • The Journal of Advanced Prosthodontics
    • /
    • 제10권3호
    • /
    • pp.252-258
    • /
    • 2018
  • PURPOSE. The purpose of this study was to evaluate the repeatability and matching accuracy between two identical intraoral spectrophotometers. MATERIALS AND METHODS. The maxillary right central incisor, canine, and mandibular left central incisor of each of 30 patients were measured using 2 identical intraoral spectrophotometers with different serial numbers (EasyShade V). The color of each shade tab from 3 shade guides (VITA 3D-Master) was also determined with both devices. All measurements were performed by a single operator. Statistical analyses were performed to verify the repeatability, accuracy, and the differences between the devices with paired t-tests, one-way ANOVA, and intra-class correlation coefficients (ICCs) (${\alpha}=.05$). RESULTS. A high level of measurement repeatability (ICC>0.90) among $L^*$, $a^*$, and $b^*$ color components was observed within and between devices (P<.001). Intra-device matching agreement rates were 80.00% and 81.11%, respectively, while inter-device matching agreement rate was 51.85%. ANOVA revealed no significant different color values within each device, while paired t-test provided significant different color values between both devices. The CIEDE2000 color differences between both devices were $2.28{\pm}1.61$ ${\Delta}E_{00}$ for in-vivo readings. Regarding the clinical matching accuracy of both devices, ${\Delta}E_{00}$ values between teeth and matching shade tabs were $3.05{\pm}1.19$ and $2.86{\pm}1.02$, respectively. CONCLUSION. Although two EasyShade V devices with different serial numbers show high repeatability of CIE $L^*$, $a^*$, and $b^*$ measurements, they could provide different color values and shade for the same tooth.

배경 색조 차단 목적의 불투명 복합 레진의 두께와 반투명도 (Thickness and translucency of opaque shade composite resin for masking effect)

  • 백경원;김성준
    • 대한치과의사협회지
    • /
    • 제49권4호
    • /
    • pp.203-210
    • /
    • 2011
  • The aims of this study were to evaluate the adequate thickness of opaque resins for situations such as an oral black cavity and discolored tooth structure, as well as the translucency of each opaque material at various thicknesses. Six opaque-shade composite resins (Z-350 OA3, Amelogen Universal A2O, Esthet-X A2O, Esthet-X A4O, Charmfil UO and Aelite Universal OA3) were prepared in metal molds with a hole of 8 mm in diameter and various thicknesses (0.5mm, 1.0mm, 1.5mm, 2.0mm, 2.5mm, 3.0 mm and 4.0mm). Four backgrounds (white tile, black tile, C4 shade porcelain and opaque resin itself) were used to determine the translucency parameter (between black and white backgrounds). and to mimic a black oral cavity (between black and opaque resin backgrounds) and a discolored tooth structure (between C4 and opaque resin backgrounds). Color measurements were made by a colorimeter to determine the CIELAB values of each specimen with each background and to calculate the translucency parameter and ${\Delta}E^*$ value difference among the specimens on the backgrounds. The translucency parameter and ${\Delta}E^*$ obtained between black and opaque resin backgrounds decreased in similar pattern as thickness increased. A C4 background was masked by resin thicknesses of 0.5-1.0mm, while a black background required thicknesses of 1.0-2.0mm. Adequate knowledge about differences in the optical character like translucency of the materials used is essential, together with the accumulated experience of the individual clinician.

치아미백에 관한 부산시민의 인식 및 지식도 조사 연구 (A research on the questionnaires about Busan citizen's understanding of the Tooth Bleaching)

  • 이혜진;전은숙
    • 한국치위생학회지
    • /
    • 제6권1호
    • /
    • pp.79-91
    • /
    • 2006
  • Through the investigation and analysis for awareness about Tooth Bleaching treatment for general adults, to rethink the real ideas of Tooth Bleaching which adults has already had and to find the method for generalized Tooth Bleaching, this study made a survey about General Awareness and Common sense for Tooth Bleaching and Oral Health Knowledge and Generalization Methods for 570adult citizen in Busan from 1th August to 10th September. The obtained results were as follows 1. Tooth Shade self contentment was found low, self-discontent respondents were 73.5% and self-content respondents were 26.5%. 2. Tooth Bleaching recognition was found high, as for the recognition period, between 2 and 5 years is 65.5% and as for the recognition route, 33.9% were through broadcast medium. 3. General knowledge for Tooth Bleaching was found low as 2.34(1.12) of 5 score and it is similar to ages and occupations(pE0.001, pE0.05). 4. Tooth Bleaching treatment method appears Home Bleaching and In-Office bleaching was 73.5% and 26.5% respectively. The other side medical institution chosen for Tooth Bleaching treatment appears dental hospital or dental clinic and Home bleaching was 75.6% and 12.1% respectively. 5. To generalize the Tooth Bleaching Care, recommendations of oral health care team and oral health education and development of information data also need to be performed.

  • PDF

복합레진의 광중합 전·후와 shade guide의 색차 비교 (COLOR DIFFERENCES BETWEEN RESIN COMPOSITES BEFORE- AND AFTER-POLYMERIZATION, AND SHADE GUIDES)

  • 전이주;조성식;엄정문
    • Restorative Dentistry and Endodontics
    • /
    • 제24권2호
    • /
    • pp.299-309
    • /
    • 1999
  • The composite resin, due to its esthetic qualities, is considered the material of choice for restoration of anterior teeth. With respect to shade control, the direct-placement resin composites offer some distinct advantages over indirect restorative procedures. Visible-light-cured (VLC) composites allow dentists to match existing tooth shades or to create new shades and to evaluate them immediately at the time of restoration placement. Optimal intraoral color control can be achieved if optical changes occurring during application are minimized. An ideal VLC composite, then, would be one which is optically stable throughout the polymerization process. The shade guides of the resin composites are generally made of plastic, rather than the actual composite material, and do not accurately depict the true shade, translucency, or opacity of the resin composite after polymerization. So the numerous problems associated with these shade guides lead to varied and sometimes unpredictable results. The aim of this study was to assess the color changes of current resin composite restorative materials which occur as a result of the polymerization process and to compare the color differences between the shade guides provided with the products and the actual resin composites before- and after-polymerization. The results obtained from this investigation should provide the clinician with information which may aid in improved color match of esthetic restoration. Five light activated, resin-based materials (${\AE}$litefil, Amelogen Universal, Spectrum TPH VeridonFil-Photo, and Z100) and shade guides were used in this study. Three specimens of each material and shade combination were made. Each material was condensed inside a 1.5mm thick metal mold with 10mm diameter and pressed between glass plates. Each material was measured immediately before polymerization, and polymerized with Curing Light XL 3000 (3M Dental products, USA) visible light-activation unit for 60 seconds at each side. The specimens were then polished sequentially on wet sandpaper. Shade guides were ground with polishing stones and rubber points (Shofu) to a thickness of approximately 1.5mm. Color characteristics were performed with a spectrophotometer (CM-3500d, Minolta Co., LTD). A computer-controlled spectrophotometer was used to determine CIELAB coordinates ($L^*$, $a^*$ and $b^*$) of each specimen and shade guide. The CIELAB measurements made it possible to evaluate the amount of the color difference values (${\Delta}E{^*}ab$) of resin composites before the polymerization process and shade guides using the post-polishing color of the composite as a control, CIE standard D65 was used as the light source. The results were as follows. 1. Each of the resin composites evaluated showed significant color changes during light-curing process. All the resin composites evaluated except all the tested shades of 2100 showed unacceptable level of color changes (${\Delta}E{^*}ab$ greater than 3.3) between pre-polymerization and post-polishing state. 2. Color differences between most of the resin composites tested and their corresponding shade guides were acceptable but those between C2 shade of ${\AE}$litefil and IE shade of Amelogen Universal and their respective shade guides exceeded what is acceptable. 3. Comparison of the mean ${\Delta}E{^*}ab$ values of materials revealed that Z100 showed the least overall color change between pre-polymerization and post-polishing state followed by ${\AE}$litefil, VeridonFil-Photo, Spectrum TPH, and Amelogen Universal in the order of increasing change and Amelogen Universal. Spectrum TPH, 2100, VeridonFil-Photo and ${\AE}$litefil for the color differences between actual resin and shade guide. 4. In the clinical environment, the shade guide is the better choice than the shade of the actual resin before polymerization when matching colors. But, it is recommended that custom shade guides be made from resin material itself for better color matching.

  • PDF

Influences of luting cement shade on the color of various translucent monolithic zirconia and lithium disilicate ceramics for veneer restorations

  • Ghada Alrabeah;Nawaf Alamro;Atif Alghamdi;Ahmed Almslam;Meshari Azaaqi
    • The Journal of Advanced Prosthodontics
    • /
    • 제15권5호
    • /
    • pp.238-247
    • /
    • 2023
  • PURPOSE. The purpose of this study was to assess the effect of resin cement shade on the color of different novel ultratranslucent monolithic zirconia and lithium disilicate veneer materials. MATERIALS AND METHODS. For a total of 40 specimens, flat cylindrical discs with a 9-mm diameter and 0.5-mm thickness were created using CAD/CAM technology. The specimens were divided into five groups according to their material (n = 8) (e.max, Prettau, Aidite, Shofu and Dima) using A1 shade. Resin discs with the same diameter and shade as the specimens served as tooth-colored substructures. Three shades (neutral, light and warm) of resin cement try-in pastes (Variolink Esthetic LC) were used as the luting cement material. The color of each material group was measured before and after cementation using the three cement shades, and the CIE L*a*b* coordinates were obtained with a spectrophotometer. Values for the translucency parameter (TP) and color change delta E (E) before (baseline) and after cementation of each specimen were determined. To compare differences among the material groups within each shade of cement and among various shades of cement within each material, the data were analyzed using one-way ANOVA and post hoc testing. RESULTS. Color coordinates L*, a* and b* significantly changed after the application of try-in pastes relative to baseline values, with a noticeable decrease in lightness (L*) (P < .05). A significant color change (ΔE) was observed in all tested materials after cementation, with ΔE values exceeding 3.3 (P < .05). Although TP changed after cementation for most materials tested, these changes were not statistically significant (P > .05). Shofu and Dima ceramics showed the lowest TP values, while Aidite and Prettau showed the highest TP values. For e.max, translucency decreased after cementation with neutral and warm shades, and it significantly increased after cementation with a light shade. CONCLUSION. The shade of cement significantly altered the final color of the ceramic veneer material to a level above the threshold at which the clinical perception of color change occurred (> 3.3). The TP was not influenced by the cement shade. The translucency levels of the novel ultratranslucent multilayer monolithic zirconia ceramics Aidite and Prettau were higher than that of the lithium disilicate e.max material.

지르코니아 코아의 색조부여가 전부도재관의 색조에 미치는 영향에 대한 분광측색분석 (Spectrophotometric analysis of the influence to shade of zirconia core on the color of ceramic)

  • 백기현;우이형;권긍록;김형섭
    • 대한치과보철학회지
    • /
    • 제46권4호
    • /
    • pp.409-419
    • /
    • 2008
  • 연구목적: 인간은 누구나 아름다움을 추구하는 욕망을 가지고 있으며 치의학 분야에서도 심미란 중요한 치료목적 중의 하나이다. 최근에는 부하를 많이 받는 구치부에까지 심미적 요구가 증가됨에 따라 지르코니아를 이용한 코아의 사용이 증가되고 있다. 기본적으로 zirconium oxide의 색상은 흰색-상아색이며, 만약 하부구조물이 이미 인접치의 색조와 조화되어 있다면 색조 부여에 훨씬 유리할 것이며, 원하는 색상을 내기 위하여 필요한 도재층의 두께를 감소시킬 수 있어 더 많은 치질을 보존할 수 있을 것이다. 연구재료 및 방법: 이 연구에서는 현재 임상에서 사용되고 있는 3가지 지르코니아 시스템의 코아 색조 부여 유무와 도재층의 두께가 전부도재관의 색조에 미치는 영향을 알아보기 위하여, 각 시스템의 코아에 색조 부여를 한 실험군과 부여하지 않은 실험군으로 구분하여 코아에 축성한 도재층의 두께에 따른 각각의 색조를 분광측색장치를 이용하여 CIE $L^{*}a^{*}b^{*}$ 색체계를 사용하여 색차를 비교, 분석하였다. 결과: 도재층 0.5 mm 축성시 Lava Frame Zirconia 군과 KaVo Everest Zirconia 군은 코아의 색조 부여 유무에 따라 육안으로 인지 가능한 색조 차이를 보이지 않았으나, Digident CAD/CAM Zirconia 군의 경우 육안으로 인지 가능한 색조차이를 보여 하부 코아의 색조가 충분히 피개되지 못하는 것으로 나타났다. 또한 도재층의 두께를 0.4 mm로 감소시켰을 때 코아 자체에 색조를 부여한 Lava Frame Zirconia 군과 KaVo Everest Zirconia 군의 경우 육안으로 인지 가능한 색조의 차이를 보이지 않았으나, 불투명 도재를 도포한 Digident CAD/CAM Zirconia 군의 경우 육안으로 인지 가능한 색조의 차이를 보였다. 결론: 코아 자체에 색조를 부여할 경우 지르코니아 코아 자체의 색을 피개하기 위해 도포하는 불투명 도재층 축성에 필요한 두께를 감소시킬 수 있어 색조 재현에 더욱 유리하며, 치아의 삭제량을 감소시킬 수 있을 것으로 판단되었다.

Study of the most frequent natural tooth colors in the Spanish population using spectrophotometry

  • Gomez-Polo, Cristina;Gomez-Polo, Miguel;Martinez Vazquez de Parga, Juan Antonio;Celemin Vinuela, Alicia
    • The Journal of Advanced Prosthodontics
    • /
    • 제7권6호
    • /
    • pp.413-422
    • /
    • 2015
  • PURPOSE. To identify the most frequent natural tooth colors using the Easyshade Compact (Vita -Zahnfabrik) spectrophotometer on a sample of the Spanish population according to the 3D Master System. MATERIALS AND METHODS. The middle third of the facial surface of natural maxillary central incisors was measured with an Easyshade Compact spectrophotometer (Vita Zahnfabrik) in 1361 Caucasian Spanish participants aged between 16 and 89 years. Natural tooth color was recorded using the 3D Master System nomenclature. The program used for the present descriptive statistical analysis of the results was SAS 9.1.3. RESULTS. The results show that the most frequent dental color in the total sample studied is 3M1 (7.05%), followed by the intermediate shade 1M1.5 (6.91%) and 2L1.5 (6.02%). CONCLUSION. According to the research methodology used, and taking into account the limitations of this study, it can be proposed that the most frequent color among the Spanish population is 3M1; the most common lightness group is 2; the most frequent hue group according to the 3D Master System is M and the most frequent chroma group is 1.5.

전문가 미백시 sealing technique의 효율성에 관한 연구 (The effectiveness of sealing technique on in-office bleaching)

  • 이윤;권소란;박정원
    • Restorative Dentistry and Endodontics
    • /
    • 제33권5호
    • /
    • pp.463-471
    • /
    • 2008
  • 본 연구는 전문가 미백시 Sealed bleaching technique의 효율과 안정성을 평가하기 위해 split arch design의 randomized clinical trial을 시행하였다. 10명의 건전한 자연치를 가진 성인 환자의 상악 전치부를 좌우측으로 무작위로 나누어 전문가 미백 술식을 시행하였다. Brite powder (PacDent, Walnut, USA) 한 스푼에 10 방울의 3% 과산화수소수와 0.4ml의 carbamide peroxide gel (KoolWhite, PacDent, Walnut, USA)을 혼합하여 미백제로 사용하였다. 편측의 세 치아를 대조군으로 지정하여 통상적인 방법으로 전문가 미백을 시행하였고, 반대측의 세 치아는 실험군으로 미백제 위에 linear low density polyethylene (LLDPE) wrap을 적용후 BT Cool light을 1시간 동안 적용하여 광활성화 하였다. 치아의 색조는 shadeguide를 이용하여 평가하는 방법과 spectrophotometer를 이용하여 측정하는 두 가지 방법을 이용하였으며, 술전, 술후, 체크시의 색조 측정 결과를 paired-t test로 분석하여 다음의 결과를 얻을 수 있었다. Shade guide로 평가한 결과 실험군과 대조군 모두에서 술후와 체크시의 색조와 술전의 색조와는 유의한 차이가 있었다 (p<.05). 또한 술전에는 대조군과 실험관간의 색조의 유의차가 없었던 반면 술후와 체크 (p<.05)시 모두에서 두 군간의 차이가 있었다 (p<.05). Spectrophotometer로 측정한 ${\Delta}E$ 값의 경우, 술후에는 대조군에서 $4.35{\pm}1.38$, 실험군에서 $5.08{\pm}1.34$로 나타났으며, 체크시에는 대조군에서 $3.73{\pm}1.95$, 실험관에서는 $4.38{\pm}2.08$로 나타났다. ${\Delta}E$는 술전과 술후를 비교한 값, 그리고 술전과 체크시를 비교한 값 모두에서 실험군과 대조군 간의 유의차가 있었다 (p<05). 따라서 이 연구에서 사용된 미백 술식을 사용할 경우, sealed bleaching technique이 미백의 효율성을 높인다고 결론지을 수 있다.

15% 과산화수소 함유 전문가용 치아 미백제의 광활성화 여부에 따른 미백효과 및 안전성에 관한 임상평가 (Clinical assessment of whitening efficacy and safety of in-office tooth whitening system containing 15% hydrogen peroxide with or without light activation)

  • 노영석;노영지;유연지;이향옥;임상민;권현정;김예은;박성연;윤희영;이정현;이찬희;오소람;금기연
    • Restorative Dentistry and Endodontics
    • /
    • 제36권4호
    • /
    • pp.306-312
    • /
    • 2011
  • 연구목적: 본 임상 연구의 목적은 15% 과산화수소를 함유한 전문가용 치아 미백제의 광활성화 여부에 따른 미백효과와 안전성에 관해 평가하는 것이다. 연구 재료 및 방법: 33명의 지원자를 광조사를 하는 실험군(n = 17)과 광조사를 하지 않는 대조군(n = 16)으로 무작위로 나누고 Zoom2 미백제(15% $H_2O_2$, Discus Dental)로 총 45분간 치료하였다. Vitapan Classical shade guide와 Shadepilot (DeguDent)을 이용해 스크리닝 검사 시, 미백직후, 미백 종료 1달 및 3달 후 색조측정을 시행하였다. 통계분석을 위해 t-test, repeated measure ANOVA 와 카이제곱 검정을 시행하였다. 결과: Zoom2 미백제는 미백 전후를 비교할 때 실험군과 대조군 모두에서 뚜렷한 색조 변화를 가져왔다. 하지만, 두 군 사이의 색조 변화량을 비교했을 때 통계학적으로 유의성 있는 차이는 관찰되지 않았다(p > 0.05). 또한 미백 종료 3달 후에도 치아의 색조 회귀는 관찰되지 않았다. 미백 후 일시적인 지각과민증은 전체 환자의 39.4%에서 보고되었지만, 두 군간의 차이는 보이지 않았다(p > 0.05). 결론: 광조사로 인해 부가적인 미백효과의 증가는 물론 어떠한 부작용 증가도 관찰되지 않았다.