• Title/Summary/Keyword: tooth loss

Search Result 600, Processing Time 0.026 seconds

THE INFLUENCE ON THE ERUPTION OF MANDIBULAR 1st PREMOLARS AFTER PREMATURE LOSS OF MANDIBULAR 1st DECIDUOUS MOLARS (하악(下顎) 제1유구치(第一乳臼齒) 조기상실(早期喪失)이 하악(下顎) 제1소구치(第一小臼齒) 맹출(萌出)에 미치는 영향(影響))

  • Cha, Bong-Ik
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.11 no.1
    • /
    • pp.91-101
    • /
    • 1984
  • The purpose of this study is to determine what influence the lesion and the premature loss of mandibular 1st deciduous molar have on the eruption of its successor, and the author devided 580 cases of orthopantomograms from age 3 to 9 years old children into 3 groups: Control Group: both side normal Study I Group: one normal and the other lesion. Study II Group: one normal and the other premature loss before 8 years old. and observed the amount of differences and the relative position in eruption between study-tooth successor and normal-tooth successor, The following results were obtained: 1. The differences in eruption between right and left mandibular 1st primary molars of Study Group were greater than those of Control Group. 2. The successors of lesioned-teeth showed more accelerated eruption than the antimeres in 40.9% and more delayed, in 22.7%. 3. The successors of premature lost-teeth showed more accelerated eruption than the antimeres in 61.7% and more delayed, in 4.3%.

  • PDF

Full mouth rehabilitation of iatrogenic attrition patient (의원성 마모 환자의 전악 수복 증례)

  • Lim, Na-Kyung;Shin, Soo-Yeon
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.59 no.2
    • /
    • pp.228-237
    • /
    • 2021
  • Physiologic tooth attrition is accepted as a natural change. But when pathologic changes, such as loss of occlusal vertical dimension, masticatory pain, loss of masticatory function, and loss of esthetics occur, restorative measures should be taken by dentist. A patient visited the clinic with the chief complaint of 'My lower teeth bite the palate and it hurts'. It was diagnosed as iatrogenic attrition of lower natural dentition caused by inappropriate upper restorations, resulting in traumatic overbite. Through model analysis and diagnostic wax up, increase in vertical dimension was decided. Upper and lower dentitions were restored with new prostheses. After restoration, satisfactory outcomes were achieved both in functional and esthetic aspects.

Evaluation of the Effect of Various Root Planing Instruments on the Root Surfaces (수종의 기구를 이용한 치근면 활택술후 치근면의 변화)

  • Kim, Tae-Beom;Lim, Sung-Bin;Chung, Chin-Hyung
    • Journal of Periodontal and Implant Science
    • /
    • v.29 no.1
    • /
    • pp.65-80
    • /
    • 1999
  • The purpose of this study was to evaluate the effects of periodontal curet and various rotating instruments on the root surfaces. Thirty-five extracted teeth with advanced periodontal disease were used. They was root planed with periodontal curet, periodontal Perio-Clean bur, periodontal Roto-Perio bur, resin polishing ET bur, and resin polishing diamond fissure bur. To find dentinal tubule orifices on the root surface, tetracycline HCI solution was applied to the one tooth of treated each group. Then, root surfaces were investigated using scanning electron microscope. Amount of loss of cementum was evaluated by loss of tooth substance index. The results were as follows. 1. Groups treated with periodontal curet and Perio-Clean bur showed irregular surface and concavities. Concavities seemed to be lacunae of cementocyte. Other groups treated with Roto-Perio bur, resin polishing ET bur, and resin polishing diamond fissure bur showed partially opened dentinal tubule orifice. 2. Groups treated with periodontal curet and Perio-Clean bur and tetracycline HCl showed irregular surface. No dentinal tubule orifice was seen. Other groups treated with Roto-Perio bur, resin polishing ET bur, and resin polishing diamond fissure bur and tetracycline HCl showed dentinal tubule orifice with various shape and size. 3. Loss of tooth substance indices were compared between groups. There was no statistically difference between periodontal curet and Perio-Clean bur groups. There were statistically differences between periodontal curet and Roto-Perio bur, ET bur, and diamond fissure bur groups. As a result of this study, groups treated with Roto-Perio bur, resin polishing ET bur, and resin polishing diamond fissure bur showed more cementum removed than groups treated with periodontal curet and Perio-Clean bur. Therefore, in a conventional treatment for periodontal disease, it was recommended that periodontal curet or Perio-Clean bur should be used. In a treatment for regeneration of periodontal tissue, it was recommended that Roto-Perio bur, resin polishing ET bur, or resin polishing diamond fissure bur should be used

  • PDF

Interproximal contact loss between implant-supported prostheses: a clinical report (임플란트 고정성 보철물 사이에서의 인접면 접촉상실: 증례보고)

  • Yeon-Hee Park;Kyoung-A Kim;Jung-Jin Lee;Jae-Min Seo
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.62 no.1
    • /
    • pp.47-53
    • /
    • 2024
  • Interproximal contact loss (ICL) is the most frequent complication in partially edentulous patients treated with implant-supported prostheses. However, in most cases, ICL occurs between the implant prosthesis and the natural tooth due to the movement of the natural tooth. There are several causes of ICL that occur between an implant prosthesis and a natural tooth. There are only a few reported cases of ICL occurring between implant prostheses, and explaining the causes of ICL between implant prostheses and natural teeth is challenging. This clinical report describes cases of ICL between implant prostheses and discusses its causes and countermeasures.

The effects of alveolar bone loss and miniscrew position on initial tooth displacement during intrusion of the maxillary anterior teeth: Finite element analysis

  • Cho, Sun-Mi;Choi, Sung-Hwan;Sung, Sang-Jin;Yu, Hyung-Seog;Hwang, Chung-Ju
    • The korean journal of orthodontics
    • /
    • v.46 no.5
    • /
    • pp.310-322
    • /
    • 2016
  • Objective: The aim of this study was to determine the optimal loading conditions for pure intrusion of the six maxillary anterior teeth with miniscrews according to alveolar bone loss. Methods: A three-dimensional finite element model was created for a segment of the six anterior teeth, and the positions of the miniscrews and hooks were varied after setting the alveolar bone loss to 0, 2, or 4 mm. Under 100 g of intrusive force, initial displacement of the individual teeth in three directions and the degree of labial tilting were measured. Results: The degree of labial tilting increased with reduced alveolar bone height under the same load. When a miniscrew was inserted between the two central incisors, the amounts of medial-lateral and anterior-posterior displacement of the central incisor were significantly greater than in the other conditions. When the miniscrews were inserted distally to the canines and an intrusion force was applied distal to the lateral incisors, the degree of labial tilting and the amounts of displacement of the six anterior teeth were the lowest, and the maximum von Mises stress was distributed evenly across all the teeth, regardless of the bone loss. Conclusions: Initial tooth displacement similar to pure intrusion of the six maxillary anterior teeth was induced when miniscrews were inserted distal to the maxillary canines and an intrusion force was applied distal to the lateral incisors. In this condition, the maximum von Mises stresses were relatively evenly distributed across all the teeth, regardless of the bone loss.

Immediate implant placement in areas of aesthetic priority (상악 전치부에서 단일 치아 발거 후 즉시 임플란트 식립)

  • Lee, Seung-Hoon;Kim, Young-Sung;Kim, Won-Kyung;Lee, Young-Kyoo
    • Journal of Periodontal and Implant Science
    • /
    • v.37 no.3
    • /
    • pp.637-646
    • /
    • 2007
  • Implants placed immediately after tooth extraction have been shown to be a successfully predictable treatment modality. Several clinical papers suggest that placing implants immediately after tooth extraction may provide some advantages: reduction of the number of surgical procedures or patient visits, preservation of the dimensions of alveolar ridge, and shortening of the interval between the removal of the tooth and the insertion of the implant supported restoration. In this case report, three patients received single immediate implant placements to replace a maxillary anterior tooth at the time of extraction. As the three cases were somewhat different, treatment protocols had to be modified as follows: Case 1. Immediate implant placement with healing abutment connection. Case 2. Immediate implant placement with immediate provisionalization. Case 3. Immediate implant placement with Guided Bone Regeneration(GBR). Every implant of these cases was placed in proper position buccolingually, mesiodistally and apicocoronally, The procedures following implantation such as immediate provisionalization and GBR were free of problem. Healing of each case was uneventful. In all cases, treatment outcomes were mostly satisfactory and the results maintained during follow-up periods. However, one case (Case 3) showed some papilla loss due to failure in delicate soft tissue handling during surgery. This papilla loss was compromised by prosthetic means. In conclusion, immediate implant placement in the fresh extraction socket can be a valid and successful option of treatment in aesthetic area. Moreover, this treatment protocol seems to maintain the preexisting architecture of soft and hard tissues in most cases.

A case of full mouth rehabilitation in patient with loss of vertical dimension and deep bite due to tooth wear (치아 마모로 인한 수직고경감소와 과개교합을 가진 환자에서 전악 수복 증례)

  • Seo, Seong-Yong;Lee, Na-Young;Kang, Jeong-Kyung
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.56 no.1
    • /
    • pp.31-39
    • /
    • 2018
  • The collapse of the posterior occlusion destroys the normal occlusal plane and causes excessive wear reducing the vertical dimension. Reduced vertical dimension of occlusion causes not only aesthetic and functional problems but also overloading on the temporomandibular joints and abnormalities of muscle nerve system. In order to improve the collapsed occlusal relationship, it is necessary to consider the change of the vertical dimension. It is necessary to make a precise diagnosis and analysis before the treatment and to evaluate the adaption of patient to the new vertical dimension of occlusion. A patient with excessive overbite often has occlusal problems of tooth wear and tooth eruption. Considering these considerations, overall prosthodontic restoration is required to solve the problem. A patient of 68 year old man in this case who suffered major tooth wear and maxillary posterior teeth loss was treated with elevation of vertical dimension of occlusion by maxillary removable dental prosthesis and mandibular fixed prosthesis.

Mandibular full-arch rehabilitation with increased vertical dimension of a patient with severe tooth wear (심한 치아 마모 환자의 수직 교합고경 증가를 동반한 하악 편악 수복 증례)

  • Kim, Hyun-Jin;Kim, Jong-Jin;Baik, Jin;Cha, Hyun-Suk;Lee, Joo-Hee
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.38 no.3
    • /
    • pp.162-170
    • /
    • 2022
  • In the case of patients with pathological tooth wear, it is necessary to evaluate the loss of the vertical dimension. Setting the appropriate vertical dimension is important to rehabilitate the patient's stable intermaxillary relationship. A 77-year-old female patient's chief complaint was the pain of the mandibular incisors and the lack of molars. At the first visit, pathologic tooth wear of the mandibular incisors were observed. After diagnosis and evaluation, loss of vertical dimension was not observed, but insufficient intermaxillary space for prosthetic restoration was confirmed. Mandibular rehabilitation was performed with vertical dimension increase and this showed satisfactory results both functionally and aesthetically.

A 5-year retrospective clinical study of the Dentium implants

  • Lee, Jeong-Yol;Park, Hyo-Jin;Kim, Jong-Eun;Choi, Yong-Geun;Kim, Young-Soo;Huh, Jung-Bo;Shin, Sang-Wan
    • The Journal of Advanced Prosthodontics
    • /
    • v.3 no.4
    • /
    • pp.229-235
    • /
    • 2011
  • PURPOSE. The aim of this retrospective study was to evaluate cumulative survival rate (CSR) of Implantium implants followed for 5 years and association between risk factors and the CSR. MATERIALS AND METHODS. A total of two hundred forty-nine Implantium Implants System (Dentium, Seoul, Korea) placed in ninety-five patients from 2004 to 2009 were investigated with several identified risk factors (sex, systemic disease, smoking, alchohol, reason of tooth loss, length, arch (maxilla or mandible), replace tooth type (incisor, canine, premolar or molar) Kennedy classification, prosthodontic type, prosthodontic design, opposite dentition, abutment type, occlusal material, occlusal unit, splint to tooth, cantilever, other surgery). Clinical examination (mobility, percussion, screw loosening, discomfort, etc.) and radiographic examination data were collected from patient records including all problems during follow-up period according to protocols described earlier. Life table analysis was undertaken to examine the CSR. Cox regression method was conducted to assess the association between potential risk factors and overall CSR. RESULTS. Five of 249 implants were failed. Four of these were lost before loading. The 5-year implant cumulative survival rate was 97.37%. Cox regression analysis demonstrated a significant predictive association between overall CSR and systemic disease, smoking, reason of tooth loss, arch, Kennedy classification and prosthodontic design (P<.05). The screw related complication was rare. Two abutment screw fractures were found. Another complications of prosthetic components were porcelain fracture, resin facing fracture and denture fracture (n=19). CONCLUSION. The 5-year CSR of Implantium implants was 97.37 %. Implant survival may be dependent upon systemic disease, smoking reason of tooth loss, arch, Kennedy classification and prosthodontic design (P<.05). The presence of systemic diseases and combination of other surgical procedures may be associated with increased implant failure.

Full mouth rehabilitation of the patient with severe tooth erosion using collarless porcelain fused to gold restorations: a case report (Collarless 금속 도재 보철물을 이용한 심한 erosion 환자의 전악수복 증례)

  • Song, Hee-Jin;Lim, Young-Jun;Kwon, Ho-Beom;Kim, Myung-Joo
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.50 no.4
    • /
    • pp.324-329
    • /
    • 2012
  • Excessive tooth wear causes loss of tooth structure, disharmony of occlusal plane, functional and esthetic problems. Although the decrease of occlusal vertical dimension may be compensated by growth of alveolar bone, if the length of tooth is not enough for the retention of restoration, minimum increase of occlusal vertical dimension is required without discomfort of the patient. In this case, 33-year-old woman drinks more than 1 liter of soft drinks a day and has bruxism in night time, visited in Seoul National University Dental Hospital with chief complaint of generalized tooth wear and related esthetic and functional problems. It was considered as a loss of occlusal vertical dimension based on the accelerated tooth wear caused by erosion and bruxism and facial appearance, phonetic, esthetic, functional evaluations. It was planned to raise occlusal vertical dimension by provisional restoration two times for patient's adaptation, 3 mm and 2 mm each, total 5 mm. Confirming no discomfort and clinical symptom during total 16 weeks after restoration with provisional fixed restoration, it was restored with porcelain fused to gold crown and bridge. Because the patient was young woman, anterior teeth were restored with collarless porcelain fused to gold crown. This case presents that satisfactory esthetic and functional result by full mouth rehabilitation with increase of occlusal vertical dimension.