• Title/Summary/Keyword: tooth fracture

Search Result 332, Processing Time 0.033 seconds

An assessment of accuracy of half-guided implant surgery using implant surgical guide: A case report (임플란트 수술용 가이드를 사용한 부분 유도 임플란트 수술의 정확도 평가: 증례보고)

  • Kim, Choongkil;Lee, Wonsup;Kwon, Ho-Beom
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.57 no.2
    • /
    • pp.150-159
    • /
    • 2019
  • Nowadays, dental implant is one of the widely used treatment options for edentulous patients. Recently, a method of improving the accuracy of implant surgery using an implant surgical guide has been introduced and widely used in order to accurately place the implant in a proper position. Full-guided and half-guided implant surgery can be distinguished according to the level of surgical guide application during the implant surgery. It is true that full-guided implant surgery exhibits higher accuracy, but half- guided implant surgery is often performed in a clinical situation due to the factors such as the circumstances of the operation. A partially edentulous patient who lost teeth due to tooth fracture and periodontal disease was treated using implant and fixed prosthesis. Half-guided implant surgery was performed using an implant surgical guide during implant surgery, the accuracy of implant placement was analyzed.

Fabrication of fixed prosthesis by employing functionally generated path technique and dual scan technique in a tardive dyskinesia patient: a case report (지연성 운동이상증 환자에서 functionally generated path 술식과 이중스캔법을 이용한 고정성 보철물 제작: 증례 보고)

  • Shilpa;Du-Hyeong Lee
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.61 no.3
    • /
    • pp.227-233
    • /
    • 2023
  • Tardive dyskinesia is an involuntary neurological movement disorder caused by long-term use of dopamine receptor-blocking drugs leading to dental implications like uncontrolled gnashing and grinding of teeth which in turn imperil the oral rehabilitation procedures as the excessive load increases the risk of prosthesis fracture. A 40-year male with a medical history of tardive dyskinesia visited the hospital to receive oral rehabilitation for missing maxillary anterior teeth. After the oral examination, tooth preparation was done on teeth 13, 15, and 23. After that silicon impression was made and the gypsum cast was digitalized using a desktop scanner and an interim prosthesis was fabricated by milling a resin block. During the try-in, the occlusal one-third of the interim prosthesis was trimmed, and an auto-polymerizing acrylic resin was applied on the occlusal surfaces and inserted in the patient's mouth. Then, the functionally generated path (FGP) of occluding surfaces of opposing arches was traced on the resin surface. When the resin was hardened, the modified interim prosthesis was removed and digitized using an intraoral scanner. The scan image was used in designing the occlusal morphology of definitive prosthesis by modifying the design of the interim prosthesis using the dual scan method. Lastly, a monolithic zirconia prosthesis was fabricated by milling a zirconia block. The definitive prosthesis was delivered reflecting the patient's occlusal scheme. This case report shows that the FGP technique with the dual scan method can help in fabricating fixed prosthesis with harmonious occlusion in a tardive dyskinesia patient.

Fabricating retrofit crowns to an existing removable partial denture by CAD-CAM: a case report (CAD-CAM을 이용한 RPD 지대치의 retrofit crown 제작 증례)

  • Hyuksoon Lee;Seong-A Kim;Joo-Hyuk Bang;Sung Yong Kim;Hee-Won Jang;Keun-Woo Lee;Yong-Sang Lee
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.62 no.2
    • /
    • pp.140-145
    • /
    • 2024
  • Removable partial denture wearers are exposed to the risks that remaining teeth get damaged by caries, attritions, erosion, and fracture. In the case of damaged abutment tooth which should fit to Removable partial denture (RPD), the fabrication of surveyed crown is followed by the making of RPD. However, making new denture takes a long time, and needs several processes and costs. Also, patients should get used to new denture. If other abutment teeth and edentulous ridges provide the existing denture with support, retention, and stability, use of existing denture is considered clinically acceptable. In this situation, fabricating retrofit crowns to an existing removable partial denture makes patient use existing denture, cuts costs, and reduces discomfort. In this case, severely worn teeth were restored using monolithic zirconia crown which fit to an existing removable partial denture by CAD-CAM. Moreover, support, retention, and stability of the denture were improved, and both doctor and patient were satisfied with the result.

An effect of Dentin Bonding Procedure on the Shear Bond Strength of Resin Cement to Porcelain Restoration (도재 수복물 합착시 상아질 접착 술식이 레진 시멘트의 전단결합강도에 미치는 영향)

  • Kang, Hae-Jin;Shin, Soo-Yeon
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.28 no.1
    • /
    • pp.67-78
    • /
    • 2012
  • The purpose of this study was to determine whether there were differences in shear bond strength to human dentin using IDS technique compared with DDS. Forty freshly extracted human molars were and devided into 4 groups. The control group specimens were, on the morrow of tooth preparation, light-cured after application of dentin bonding agent and cemented with resin cement. The IDS/SE(immediate dentin sealing, Clearfil$^{TM}$ SE Bond) and IDS/SB (immediate dentin sealing, Adapter$^{TM}$ Single Bond 2) specimens were, on the morrow of tooth preparation, light-cured after application of dentin bonding agent(Clearfil$^{TM}$ SE Bond and Adapter$^{TM}$ Sing Bond 2, respectively), whereas DDS specimens were not treated with any dentin bonding agent. IDS/SE, IDS/SB and DDS specimens were thermocycled. Following that delay, specimens were cemented with resin cement. The dentin bonding agent was left unpolymerized until the application of porcelain restoration. Shear bond strengths were measured using a universal testing machine. Specimens also were evaluated for mode of fracture using an optical microscope. The mean shear bond strengths of control group and IDS/SE groups were not statistically different from one another. The bond strength of IDS/SE group had a significantly higher mean than that of DDS group. There was no significant difference in the mean shear bond strength between IDS/SB(4.11MPa) and DDS group. The evaluation of failure modes indicates that most failures in the control group and IDS/SE groups were mixed, whereas failures in the DDS group were interfacial. When preparing teeth for indirect ceramic restoration, IDS with Clearfil$^{TM}$ SE Bond results in improved shear bond strength compared with DDS.

Clinical Evaluation of Implant-Supported Fixed Prostheses (임플란트-지지 고정성 보철물의 임상적 상태에 대한 평가)

  • Park, Chan-Yong;Yun, Mi-Jung;Huh, Jung-Bo;Jeong, Chang-Mo;Jeon, Yeong-Chan
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.29 no.4
    • /
    • pp.317-326
    • /
    • 2013
  • This study was to compare the cumulative survival rate of implant-supported fixed prostheses and to analyze association between risk factors and cumulative survival rate of implant-supported fixed prostheses. In order to assess the clinical status of implant-supported fixed prostheses, individuals who treated in the Department of Prosthodontics, Pusan National University Dental Hospital, between 2000 to 2007 were examined. The results of this study were as follows: 1. Length of service of implant-supported fixed prostheses was $6.6{\pm}32.0$ years (mean), 11.7 years (median). 2. Age and sex of patient was found to have no statistically significant influence on longevity of implant-supported fixed prostheses (P>.05). 3. Reason of tooth extraction wax found to have statistically significant influence on implant-supported fixed prostheses (P<.05). The longevity of fixed prostheses was low in tooth extraction case due to periodontal disease (median:9.0 years). 4. Location of implant-supported fixed prostheses was found to have statistically significant influence on longevity of fixed prostheses (P<.05). The longevity of fixed prostheses was low in molar region (median:8.8 years). 5. Number of units in implant-supported fixed prostheses was found to have no statistically significant influence on longevity of fixed prostheses (P>.05). 6. Condition of opposing dentition was found to have no statistically significant influence on longevity of implant-supported fixed prostheses (P>.05). 7. Food impaction (40.5%), porcelain fracture (25.8%), screw loosening (23.6%) were frequent complications.

IMMOBILIZATION OF LOWER MANDIBULAR ALVEOLAR BONE FRACTURE USING RESIN-WIRE OPEN CAP SPLINT (하악 유전치부 치조골 골절시 resin-wire open cap splint를 이용한 고정)

  • Kwon, Joung-Hyun;Choi, Byung-Jai;Choi, Hyung-Jun;Kim, Seong-Oh;Son, Heung-Kyu;Lee, Jae-Ho
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.35 no.1
    • /
    • pp.175-180
    • /
    • 2008
  • Traumatic injuries to the primary dentition are commonly encountered problems in dental practice. It is found that 30% of the children had injuries to the primary dentition and 22% to the permanent dentition. The greatest incidence of trauma to the primary dentition occurs at the ages of 2 and 3 as children start to learn motor coordination. Because teeth and alveolar bone are traumatized simultaneously, alveolar bone fractures are likely to occur when multiple teeth are involved in injuries. Dental splints are indicated for the management of maxillofacial fractures. They enable anatomic reduction of fractured segments and help immobilization and maintenance of the fragments after reduction. They also act as a stabilizer during rehabilitation. Various types of dental splints are available. In this case, routine resin-wire splint technique could not be applied because of the child's uncooperative behavior. Oral sedation was not indicated because N.P.O. had not been preceded. Therefore, we decided to use open-cap acrylic splint instead. Stabilization using open cap acrylic splint requires minimum chair time with reduced discomfort to both patient and dentist. It is an effective means of splint for uncooperative children and especially useful when other means of fixation have been failed. Because trauma on the primary dentition can affect the underlying permanent tooth germ, it is important to monitor eruption process of the permanent dentition.

  • PDF

Effects of chromium chloride addition on coloration and mechanical properties of 3Y-TZP (크롬염화물 첨가에 따른 지르코니아 색상 및 물리적 성질 변화에 관한 연구)

  • Oh, Gye-Jeong;Seo, Yoon-Jeong;Yun, Kwi-Dug;Lim, Hyun-Pil;Park, Sang-Won;Lee, Kyung-Ku;Lim, Tae-Kwan;Lee, Doh-Jae
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.49 no.2
    • /
    • pp.120-127
    • /
    • 2011
  • Purpose: The purpose of this study was to examine the effects of chromium chloride addition on coloration, mechanical property and microstructure of 3Y-TZP. Materials and methods: Chromium chloride was weighed as 0.06, 0.12, and 0.25 wt% and each measured amount was dissolved in alcohol. $ZrO_2$ powder was mixed with each of the individual slurry to prepare chromium doped zirconia specimen. The color, physical properties and microstructure were observed after the zirconia specimen were sintered at $1450^{\circ}C$. In order to evaluate the color, spectrophotometer was used to analyze the value of $L^*$, $C^*$, $a^*$ and $b^*$, after placing the specimen on a white plate, and measured according to the International Commission on Illumination (CIE) standard, Illuminant D65 and SCE system. The density was measured in the Archimedes method, while microstructures were evaluated by using the scanning electron microscopy (SEM) and XRD. Fracture toughness was calculated Vickers indentation method and indentation size was measured by using the optical microscope. The data were analyzed with 1-way ANOVA test (${\alpha}$ = 0.05). The Tukey multiple comparison test was used for post hocanalysis. Results: 1. Chromium chloride rendered zirconia a brownish color. While chromium chloride content was increased, the color of zirconia was changed from brownish to brownish-red. 2. Chromium chloride content was increased; density of the specimen was decreased. 3. More chromium chloride in the ratio showed increase size of grains. 4. But the addition of chromium chloride did not affect the crystal phase of zirconia, and all specimens showed tetragonal phase. 5. The chromium chloride in zirconia did not showed statistically significant difference in fracture toughness, but addition of 0.25 wt% showed a statistically significant difference (P<.05). Conclusion: Based on the above results, this study suggests that chromium chlorides can make colored zirconia while adding in a liquid form. The new colored zirconia showed a slight difference in color to that of the natural tooth, nevertheless this material can be used as an all ceramic core material.

A Study on the Traumatic Teeth Damage of Children (어린이의 외상성 치아손상에 관한 연구)

  • Yoo, Su-Min;Park, Ho-won
    • Journal of dental hygiene science
    • /
    • v.4 no.1
    • /
    • pp.21-25
    • /
    • 2004
  • In modern times, children's trauma is increasing every year because of car accidents and life environment changes. There is a limit to prevent traumatic damage for oral cavity organization. The fundamental data of trauma treatment and prevention will be presented through the survey and analysis of traumatic teeth damage. I examined 113 patients from Oct. 4th, 2000 to Feb. 27th, 2004 at Dept. of Children's Dental Clinic, Kangnung National University. The results are as follows. (1) The trauma frequency of male subjects is higher than that of female at a rate of 2.05:1. The average age is 5.27 for men and 5.27 for women. The highest percentage of trauma patients is among 2 year old children. It is 21.2%. (2) A patient survey was taken at a trauma treatment hospital. On the first day 34.4% of the patients had come to receive treatment of their first set of teeth. However, after a week, 38.8% of the patients had received treatment on their permanent teeth. (3) As a result of falling, 59% of patients needing treatment on their first set of teeth. 55.1% of patients is permanent teeth. As a result of bump against physical solid, 26.6% of patients is the first set of teeth and 26.5% of patients is permanent teeth. (4) Teeth damage happened at home. 42.1% were male. 35.1% were female. According to trauma, 59.4% of teeth damage happened at home. 28.6% of permanent teeth damage happened at school or kindergarten. (5) According to trauma, the number of teeth damaged was in the first set of teeth are as follows: 56.3%, one-31.3%, three or four-6.3% each. For permanent teeth: two-46.9%, one-28.6%, four over-16.3% and three-8.2%. Over four teeth is larger number for permanent teeth. (6) 56% of first set of teeth patients and 43.4% of permanent teeth patients were male. 56.8% of first set of teeth patients and 43.2% of permanent teeth were female. Trauma happened to both male and female frequently in the first set of teeth. (7) Most of the tooth damage which was in the first set of teeth and permanent teeth was done to the upper jaw. 75% of patients are the first set of teeth. 63.8% of patients are permanent teeth. Trauma is very high in the two mid teeth of the upper jaw. (8) According to trauma survey, 30.2% is from impulse. 28.0% is from crown fracture, 14.7% is from depression. 8.9% is from concussion. 7.1% is from full dislocation of a joint. 2.2% of patients are extrusion. 1.8% is from displacement. According to teeth damage trauma, 35.8% is pulse in the first set of teeth. The breaking of the crown of a tooth happened a lot in permanent teeth. (9) According to data, 43.2% of teeth damage in the first set of teeth goes without treatment. In permanent teeth, it is 38.9%. After treatment, 22.0% of first set of teeth treatment requires a dental pulp treatment. In permanent teeth, which is used for temporary acid etching resin restoration.

  • PDF

BOND STRENGTH OF BONDED AMALGAM USING DENIAL ADHESIVES (치과용 접착제를 사용한 접착 아말감의 결합 강도)

  • Kam, Dong-Hoon;Lee, Sang-Dae;Hahn, Se-Hyun
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.26 no.2
    • /
    • pp.284-295
    • /
    • 1999
  • The purpose of this study was to measure and analyze the bond strength of bonded amalgam using dental adhesives and to compare this with light-curing composite resin. Sections 8mm in diameter were punched out from the labial surface of bovine anterior teeth. These were embedded in clear acrylic resin blocks with labial surface facing out. 55 specimens were made for enamel and dentin each. After dividing these into 5 groups, group 1: Superbond C&B, group 2: Panavia 21, group 3: All-Bond 2, group 4: Fuji I Glass Ionomer Luting Cement, group 5: Scotchbond Multi-Purpose(Restorative Z-100), molds with holes of 6.3mm in diameter and 1.5mm in depth were placed over the specimens. The exposed tooth surfaces were treated with adhesives and the molds were filled with amalgam. In group 5, the mold was filled with composite resin and light-cured for 40 seconds. The author measured all specimens for bond strength 24 hours after amalgam filing and analyzed fracture surfaces. The following results were obtained: 1. Among the dentin groups, groups 1, 2 and 4 showed significantly lower bond strength compared with group 5(P<0.05). 2. Among the enamel groups, group 4 showed significantly lower bond strength compared with group 5(P<0.05). 3. In group 2, 2D showed significantly lower bond strength compared with group 2E(P<0.05). Other adhesives showed no such differences in bond strength between dentin and enamel(P>0.05). 4. Cohesive failure was observed in groups 1E and 5D, while mixed failure was seen in groups 1 and 5. Only adhesive failures were noted in groups 2, 3, 4.

  • PDF

Fracture Resistance of Low Invasive Fixed Partial Dentures (수종 저 침습 고정성 국소의치의 수직하중에 대한 저항)

  • Choi, Jong-In;Kim, Yu-Lee;Shin, Chang-Yong;Dong, Jin-Keun
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.26 no.3
    • /
    • pp.241-251
    • /
    • 2010
  • This study aims at contributing to the restorative dentistry by examining results in the vertical load test of four different low invasive fixed partial dentures. Based on a hypothesis on the right upper first molar is missing, three units of FPDs were made for the second premolar and the second molar abutment. that is, twelve metal dies and FPDs were made for resin bonded FPD and Two Key Bridges and Human Bridge without occlusal rest and Human Bridge with occlusal rest. By using universal test machine, the numerical maximum value were recorded during the vertical load test of each FPDs after the bonding process treated by Maxcem which is resin cement. The failure process and its result of prosthesis were also observed. The maximum load was 7,295 N, 4,729 N, 2,190 N, 3,073 N from groups of resin bonded FPD, Two Key Bridge, Human Bridge without occlusal rest and Human Bridge with occlusal rest respectively. There was a statistical significance among the groups of resin bonded FPD, Two Key Bridge and Human Brides. However, there was no significant difference between Human Bridge without occlusal rest and Human Bridge with occlusal rest. Regarding the failure of prosthesis, the groups of Resin Bonded FPD and Two Key Bridge showed that one of the abutment teeth in the both side of retention part was highly failed earlier than the other one (83.2% and 66.6% respectively). While, Human Bridge without occlusal rest and Human Bridge with occlusal rest showed high percentage of failure in the abutment teeth in the both side of retention part at the same time (91.6% and 58.3% respectively). This study demonstrates that the group of Human Bridges has low resistance to the vertical loads of low invasive FPDs in comparison with the groups of resin bonded FPD and Two Key Bridge. Nevertheless, the maximum occlusal load of the restorative position, resistance to diverse restoration failure, amount of tooth reduction and patients' cooperation should be considered when they are applied in the clinic in order to choose an appropriate restoration for each patient.