• Title/Summary/Keyword: tooth

Search Result 5,811, Processing Time 0.038 seconds

Sequential traction of a labio-palatal horizontally impacted maxillary canine with a custom three-directional force device in the space of a missing ipsilateral first premolar

  • Yang, Shuliang;Yang, Xiao;Jin, Anting;Ha, Nayong;Dai, Qinggang;Zhou, Siru;Yang, Yiling;Gong, Xinyi;Hong, Yueyang;Ding, Qinfeng;Jiang, Lingyong
    • The korean journal of orthodontics
    • /
    • v.49 no.2
    • /
    • pp.124-136
    • /
    • 2019
  • Orthodontic treatment is more complicated when both soft and hard tissues must be considered because an impacted maxillary canine has important effects on function and esthetics. Compared with extraction of impacted maxillary canines, exposure followed by orthodontic traction can improve esthetics and better protect the patient's teeth and alveolar bone. Therefore, in order to achieve desirable tooth movement with minimal unexpected complications, a precise diagnosis is indispensable to establish an effective and efficient force system. In this report, we describe the case of a 31-year-old patient who had a labio-palatal horizontally impacted maxillary left canine with a severe occlusal alveolar bone defect and a missing maxillary left first premolar. Herein, with the aid of three-dimensional imaging, sequential traction was performed with a three-directional force device that finally achieved acceptable occlusion by bringing the horizontally impacted maxillary left canine into alignment. The maxillary left canine had normal gingival contours and was surrounded by a substantial amount of regenerated alveolar bone. The 1-year follow-up stability assessment demonstrated that the esthetic and functional outcomes were successful.

Accuracy of implant digital scans with different intraoral scanbody shapes and library merging according to different oral exposure height (구내 스캔바디의 형태에 따른 임플란트의 디지털 스캔 정확도 및 구강 내 노출 높이에 따른 라이브러리 중첩 정확도 비교 연구)

  • Jeong, Byungjoon;Lee, Younghoo;Hong, Seoung-Jin;Paek, Janghyun;Noh, Kwantae;Pae, Ahran;Kim, Hyeong-Seob;Kwon, Kung-Rock
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.59 no.1
    • /
    • pp.27-35
    • /
    • 2021
  • Purpose: The purpose of this study is to compare the accuracy of digital scans of implants according to different shapes of scanbodies, and to compare the accuracy of library merging according to different oral exposure height. Materials and methods: A master model with a single tooth edentulous site was prepared. For the first experiment, three types of intraoral scanbodies were prepared, divided into three groups, and the following experiments were conducted for each group: An internal hex implant was placed. The master model with the scanbody connected was scanned with a model scanner, and a master reference file (control group) was created. 10 files (experimental group) were created by performing 10 consecutive scans with an intraoral scanner. After superimposing the control and experimental groups, the following values were calculated: 1) Distance deviation of a designated point on the scanbody 2) Angle deviation of the major axis of the scanbody. For the second experiment, the scanbody scan data were prepared in 6 different heights. Library files were merged with each of the scan data. The distance and angular deviation were calculated using the 7 mm scan data as control group. Results: In the first experiment, there were no significant differences between A and B (P=.278), B and C (P=.568), and C and A (P=.711) in the distance deviations. There were no significant differences between A and B (P=.568), B and C (P=.546), and C and A (P=.112) in the angular deviations. Also, the scanbody showed significantly higher library merging accuracy in the groups with high oral exposure height (P<.5). Conclusion: There were no significant differences in scan accuracy according to the different shapes of scanbodies, and the accuracy of library merging increased according to exposure height of the scanbody in the oral cavity.

The Demands and Awareness of Pediatric Dentists on the Korean National Health Insurance System (국민건강보험에 대한 소아치과 의사들의 요구와 인식 조사 )

  • Yunhyeong, Kim;Yongkwon, Chae;Koeun, Lee;Misun, Kim;Ok Hyung, Nam;Sungchul, Choi;Hyoseol, Lee
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.49 no.3
    • /
    • pp.285-299
    • /
    • 2022
  • The aim of this study is to investigate the awareness and perception of pediatric dentists regarding dental health insurance (DHI) system in Korea. Online surveys were sent to the members of the Korean Academy of Pediatric Dentistry (KAPD), and the responses were collected. The survey, consisting of 41 questions, was subdivided into 'general background of the respondents', 'the awareness on national health insurance (NHI) and DHI', 'the awareness on DHI pertaining to pediatric dentistry', 'issues that need improvement on DHI pertaining to pediatric dentistry', 'DHI claims', and 'the roles of KAPD in DHI'. In total, 302 responded, with a response rate of 28.9%. Excluding 2 questionnaires with insufficient answers, a total of 300 survey results were analyzed. According to the analysis, pediatric dentists thought that the coverage of DHI was not as sufficient compared to that of NHI, but were expecting its scope to broaden in the future. The satisfaction rate was higher in pit and fissure sealant and composite resin filling than in caries-detecting quantitative light-induced fluorescence. Pediatric dentists considered permanent tooth composite resin filling (65.7%) needed an increase in insurance copayment, while topical fluoride application (74.7%) to require insurance coverage. DHI claims were generally handled by dental hygienists and/or nursing assistants. Approximately half of the respondents answered that they have had experiences on appealing for insurance denials. Lastly, pediatric dentists generally had a positive attitude towards providing information for the DHI. This study is expected to be used as a sound dataset for the DHI policy development concerning pediatric dentistry.

Comparison of Color Stability and Surface Roughness of 3D Printing Resin by Polishing Methods (연마 방법에 따른 3D 프린팅 레진의 색조 안정성과 표면 조도의 비교)

  • Heeju Kim;Yujin Kim;Jongsoo Kim;Joonhaeng Lee;Mi Ran Han;Jisun Shin;Jongbin Kim
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.50 no.2
    • /
    • pp.205-216
    • /
    • 2023
  • This study aimed to compare the color stability and surface roughness of three-dimensional (3D) printing resin according to polishing methods. 3D-printed resin specimens were fabricated at TC-80DP (Graphy, Seoul, Korea) with a stereolithography 3D printer, and the specimens were divided into three groups, each of which was not polished, was polished using Enhance®, and was polished using a Sof-LexTM disc. The CIE L*a*b* value and the surface roughness of each group were measured and immersed in artificial saliva and orange juice after 0, 1, 7, 30, and 60 days, and the color difference (ΔE*) was calculated. As a result of the study, no noticeable color change was observed in artificial saliva, but a noticeable color change was demonstrated in orange juice after 60 days of immersion, and the difference was significant. In the Sof-LexTM group, surface roughness according to the solution was found to be significantly higher in the orange juice than that in artificial saliva. No significant difference in color change was found according to the polishing method, but surface roughness was significantly lower in the Sof-LexTM group than both that of the unpolished group and that of the Enhance® group. Nevertheless, all groups exhibited clinically acceptable properties regardless of their higher surface roughness than the threshold for plaque accumulation. Overall, this study recommends utilizing Sof-LexTM for polishing 3D printing resin when used in primary anterior tooth coverage.

Evaluation of the Color Adjustment Potential of Single-Shade Composite Resin in Primary Teeth (유치에서의 단일 색조 복합레진의 색조 적응력 평가)

  • Yongsoon Kim;Howon Park;Juhyun Lee;Haeni Kim
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.50 no.1
    • /
    • pp.113-120
    • /
    • 2023
  • Restoring composite resins with the optimal shades for all primary teeth is a great challenge for pediatric dentists. A newly developed single-shade composite resin can exhibit a color similar to that of the surrounding tooth structure based on the structural color phenomenon. This study aims to evaluate the color adjustment potential (CAP) of a single-shade composite resin compared to conventional multi-shade composite resins in primary teeth. A single-shade composite resin and two conventional multi-shade composite resins were included in this study. Two types of specimens, a single specimen and a dual specimen, were evaluated. For single specimens, duplications of the primary second molar denture teeth were made using experimental composite resins. For dual specimens, cavities were prepared on the buccal surfaces of extracted primary second molars and restored with experimental composite resins. The L*, a*, and b* values were measured using a colorimeter for the extracted teeth and specimens. The mean ΔEab* values for single and dual specimens and CAP were calculated. Bonferroni post-hoc analysis was performed to confirm the statistical significance between the ΔEab* and CAP values of the experimental resins. Among the single specimens, the single-shade composite resin showed significantly higher ΔESingle compared to other composite resins (p < 0.0167). There was no significant difference between ΔEDual for all experimental resins. The single-shade composite resin showed highest CAP compared to other multi-shade composite resins. A single-shade composite resin exhibited the most prominent color adaptability compared to other conventional multi-shade composite resins for primary second molars. A single-shade composite resin can simplify shade matching and provide esthetic outcomes for the restoration of primary second molars.

Estimation of Mandibular Third Molar Development Using the Correlation in Dental Developmental Stages (치아 발육 단계의 상관관계를 이용한 하악 제3대구치 발육 평가)

  • Junyoung Kim;Hyuntae Kim;Teo Jeon Shin;Hong-Keun Hyun;Young-Jae Kim;Jung-Wook Kim;Ki-Taeg Jang;Ji-Soo Song
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.50 no.4
    • /
    • pp.373-384
    • /
    • 2023
  • This study aims to confirm the average chronologic age according to the developmental stages of the mandibular canine (L3), first and second premolars (L4, L5), and second and third molars (L7, L8) in children and adolescents, and to confirm the developmental stage of L3, L4, L5, and L7, which can estimate the development of L8. A total of 1,956 digital panoramic radiographs of healthy individuals aged between 6 and 15 years who visited Seoul National University Dental Hospital from January 2019 to December 2020 were selected. The developmental stages of L3, L4, L5, L7, and L8 on both sides were evaluated using the dental maturity scoring system proposed by Demirjian and Goldstein. The average age at which the follicle of L8 was first observed was around 9.34 ± 1.35 years and varied from 6 to 12 years. The possibility of agenesis of L8 was high when no traces of L8 were observed after the following stages: L3, L4, and L5 at the developmental stage F and L7 at the developmental stage E; the age was about 10 years. In estimating the development of L8, when only one tooth was considered, estimation accuracy with L5 was the highest, and there was no significant difference when all four teeth were included. This study showed the age distribution according to the developmental stages of L3, L4, L5, L7, and L8 in children and adolescents and confirmed the developmental stages of L3, L4, L5, and L7, which can be used to estimate the development of L8.

Comparison of marginal and internal fit of 3-unit monolithic zirconia fixed partial dentures fabricated from solid working casts and working casts from a removable die system (가철성 다이 시스템으로 제작된 작업 모형과 솔리드 작업 모형 상에서 제작된 지르코니아 3본 고정성 치과 보철물의 변연 및 내면 적합도 비교)

  • Wan-Sun Lee
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.40 no.2
    • /
    • pp.72-81
    • /
    • 2024
  • Purpose: This study aimed to assess the marginal and internal fit of 3-unit monolithic zirconia fixed partial dentures (FPDs) fabricated via computer-aided design and computer-aided manufacturing (CAD/CAM) from solid working casts and removable die system. Materials and Methods: The tooth preparation protocol for a zirconia crown was executed on the mandibular right first premolar and mandibular right first molar, with the creation of a reference cast featuring an absent mandibular right second premolar. The reference cast was duplicated using polyvinyl siloxane impression, from which 20 working casts were fabricated following typical dental laboratory procedures. For comparative analysis, 10 FPDs were produced from a removable die system (RD group) and the remaining 10 FPDs from the solid working casts (S group). The casts were digitized using a dental desktop scanner to establish virtual casts and design the FPDs using CAD. The definitive 3-unit monolithic zirconia FPDs were fabricated via a CAM milling process. The seated FPDs on the reference cast underwent digital evaluation for marginal and internal fit. The Mann-Whitney U test was applied for statistical comparison between the two groups (α = 0.05). Results: The RD group showed significantly higher discrepancies in fit for both premolars and molars compared to the S group (P < 0.05), particularly in terms of marginal and occlusal gaps. Color mapping also highlighted more significant deviations in the RD group, especially in the marginal and occlusal regions. Conclusion: The study found that the discrepancies in marginal and occlusal fits of 3-unit monolithic zirconia FPDs were primarily associated with those fabricated using the removable die system. This indicates the significant impact of the fabrication method on the accuracy of FPDs.

Association between the usage of dental floss and interdental brushes and the prevalence of systemic diseases (치실 및 치간칫솔 사용과 전신질환 유병률의 연관성)

  • Seon-Jip Kim;Hye-Jin Kwon;Hyun-Jae Cho
    • Journal of Korean Dental Hygiene Science
    • /
    • v.7 no.1
    • /
    • pp.17-28
    • /
    • 2024
  • Background: Oral health has a significant impact on systemic health, and the close association between oral and systemic diseases has been continuously reported. To prevent oral diseases, the role of oral hygiene products such as dental floss and interdental brushes, in addition to tooth brushing, is becoming increasingly important. This study aims to analyze the effect of using oral hygiene products on the lifetime prevalence of systemic diseases among Korean adults. Methods: This study utilized data from the 7th Korea National Health and Nutrition Examination Survey (2016-2018). The study population consisted of 13,199 adults aged 19 years and older. The independent variable was the use of oral hygiene products, and the dependent variable was the prevalence of systemic diseases diagnosed by a physician. Demographic variables, health status, and behavioral variables were included as covariates, and multivariable logistic regression analysis was performed. Results: The use of dental floss showed no significant association with the prevalence of systemic diseases. However, those who did not use interdental brushes had a 22% lower likelihood of dyslipidemia (OR 0.777, 95% CI 0.660-0.913). Among participants with periodontal disease, those who did not use dental floss had a significantly higher risk of myocardial infarction (OR 11.488, 95% CI 1.438-91.772). Conversely, those who did not use interdental brushes had lower risks of dyslipidemia, myocardial infarction, and angina, particularly among women and individuals under 65 years of age. Conclusion: This study found a low overall association between the use of oral hygiene products and the prevalence of systemic diseases, but there was a notable association with cardiovascular diseases. To reduce the risk of myocardial infarction, the prevention and treatment of periodontal disease, along with proper oral hygiene management, are crucial. Future prospective studies are needed to clearly establish the causal relationship between oral hygiene and systemic diseases.

A Study on the Stress Distribution of Tooth/Implant Connected with Konus Telescope Denture Using 3-Dimensional Finite Element Method (이중관으로 연결된 자연치와 임플랜트의 악골 내응력분포에 관한 3차원 유한요소분석)

  • Lee, Su-Ok;Choi, Dae-Gyun;Kwon, Kung-Rock;Woo, Yi-Hyung
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.46 no.4
    • /
    • pp.381-395
    • /
    • 2008
  • Purpoose: For decades dental implants have been used widely in the field of prosthetic dentistry. However there is confusion when establishing treatment plans in cases where some teeth are remained but an insufficient number of implants can be used due to limited anatomical status and ecomomical problems. Many clinicians have tried to connect natural teeth and implants, and it still has controversy. But, there have been few studies on mechanical analysis of connecting natural teeth and implants with konus telescopic removable partial dentures. The purpose of this study was to analyze the stress distribution of prosthesis, abutment and alveolar bone when teeth and implants were connected with the konus telescopic denture, by means of 3-dimensional finite element analysis. Material and methods: The assumption of this study was that there were 2 mandibular canine (11 mm in length, 4 mm in diameter) and 2 implants(10 mm in length, 4 mm in diameter) which are located in the second premolar region. The mandible, teeth, implants, abutments, and connectors are modeled, and analyzed with the commercial software, ANSYS Version 8.1(Swanson, Inc., USA). The control group used implants instead of natural teeth. 21038 elements, 23544 nodes were used in experimental group and 107595 elements, 21963 nodes were used in control group, Stress distribution was evaluated under 150 N vertical load on 3 experimental conditions - between teeth and implants (Load case 1), posterior to implants (Load case 2), between natural teeth (Load case 3). Results: 1. In all load cases, higher von mises stress value was observed in the experimental group. 2. Maximum von miss stress observed in all load cases and all locations were as follows ; a. 929.44 Mpa in the experimental group, 640.044 Mpa in the control group in outer crown and connector - The experimental group showed 1.45 times high value compared with the control group. b. 145,051 Mpa in the experimental group, 142.338 Mpa in the control group in abutment - The experimental group showed 1.02times high value compared with the control group. c. 32.489 Mpa in the experimental group, 25.765 Mpa in the control group in alveolar bone - The experimental group showed 1.26times higher value compared with the control group. 3. All maximum von mises stress was observed in load case 2, and maxim von mises stress in alveolar bone was 32.489 Mpa at which implant failure cannot occur. 4. If maximum von mises stress is compared between two groups, the value of the experimental group is 1.02 times higher than the control group in abutment, 1.26 times higher than the control group in alveolar bone. Conclusion: If natural teeth and implants are connected with the konus telescopic denture, maximum stress will be similar in abutment, 1.26 times higher in alveolar bone than the control group. With this result, there may be possible to make to avoid konus telescopic dentures where natural teeth and implants exist together.

ERUPTION TIME AND SEQUENCE OF PERMANENT TEETH IN STUDENTS FROM E-ELEMENTARY SCHOOL (E-초등학교 어린이의 영구치 맹출시기 및 순서)

  • Kwon, Joung-Hyun;Choi, Byung-Jai;Lee, Jae-Ho;Kim, Seong-Oh;Son, Heung-Kyu;Choi, Hyung-Jun
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.36 no.2
    • /
    • pp.253-261
    • /
    • 2009
  • The purpose of this study was to present new data on the timing and sequence of permanent teeth emergence and to compare these findings with the results of earlier studies. The dental examinations had been performed to E-elementary school students, who visited the Yonsei University Dental Hospital between 1998 and 2005; 1,307 boys and 1,312 girls with the age ranging from 6 to 12 years old. The followings were concluded. 1. Eruption time of the maxillary permanent teeth is as follows. It was 6.81 years in male and 6.73 years in female for the central incisor, 7.78 years in male and 7.65 years in female for the lateral incisor, 10.48 years in male and 9.92 years in female for the canine, 9.76 years in male and 9.63 years in female for the first premolar, 10.66 years in male and 10.49 years in female for the second premolar, 6.39 years in male and 6.26 years in female for the first permanent molar, and 12.13 years in male and 12.03 years in female for the second permanent molar. 2. Eruption time of the mandibular permanent teeth is as follows. The central incisor could not be determined in this study, but it is assumed to erupt before the age of 6.08. In the mandible, eruption time was 6.78 years in male and 6.65 years in female for the lateral incisor, 9.76 years in male and 9.05 years in female for the canine, 9.82 years in male and 9.59 years in female for the first premolar, 10.67 years in male and 10.52 years in female for the second premolar, 6.22 years in male and 6.12 years in female for the first permanent molar, and 11.58 years in male and 11.14 years in female for the second permanent molar. 3. The eruption sequence is as follows. In the maxilla, the first permanent molar erupted first, followed by the central incisor, the lateral incisor, the first premolar, the canine, the second premolar, and the second permanent molar. In the mandible, the central incisor erupted first, followed by the first permanent molar, the lateral incisor, the canine, the first premolar, the second premolar, and the second permanent molar. 4. Tooth eruption occurred earlier in female compared to male by average of 0.19 year in the maxilla and 0.29 year in the mandible. 5. In both male and female, the hiatus (interval of rest) occurred between the emergence of lateral incisor and first premolar in the maxilla while it was observed between the lateral incisor and canine in the mandible. Male had a hiatus of 1.98 years in the maxilla and 2.90 years in the mandible, while the female's were 1.98 years and 2.40 years, respectively.

  • PDF