• Title/Summary/Keyword: tomosynthesis

Search Result 44, Processing Time 0.023 seconds

Digital Tomosynthesis using a Flat-panel Detector based Micro-CT

  • Mandai, Koushik Kanti;Choi, Jeong-Min;Cho, Min-Hyoung;Lee, Soo-Yeol
    • Journal of Biomedical Engineering Research
    • /
    • v.29 no.5
    • /
    • pp.364-370
    • /
    • 2008
  • Recent development in large area flat-panel x-ray detector technology enables clinical application of digital tomosyntesis. Unlike conventional motion tomography using x-ray films, flat-panel x-ray detectors provide projection images in digital formats so that tomographic images can be synthesized in a more flexible way. For the digital tomosynthesis, precise movements of the x-ray source and the x-ray detector with respect to a fulcrum point are necessary. In this study, we apply the digital tomosynthesis technique to the flat-panel detector based micro-CT in which the flat-panel detector and the x-ray source rotate together on a circular arc. The experimental results suggest that flat-panel detector based 3D CTs can be used for digital tomosynthesis in the clinical environment.

Utilization of Mammogram in the Tomosynthesis (토모신테시스의 유방촬영에서의 활용)

  • Lee, Mi-Hwa
    • The Journal of the Korea Contents Association
    • /
    • v.15 no.11
    • /
    • pp.322-328
    • /
    • 2015
  • This study evaluated the diagnostic value and compares the Mammogram Tomosynthesis, and as compared to the AGD, was studied with respect to utilization of Tomosynthesis. During January 2015 one month were enrolled patients admitted to 62 people present. The ACR phantom was used. AEC was set to be. kVp is fixed and given a step-by-step changing the mAs analyzed AGD. Tomosynthesis was superior to the distinction of breast lesions when compared with Mammogram showed a noticeable difference in contrast. AGD(Average Glandular Dose) was higher 0.33 mGy. However, in the long run, the dose was reduced. Tomosynthesis is therefore increase the diagnostic value of the breast, a examination that can reduce the dose.

Effect of the Number of Projected Images on the Noise Characteristics in Tomosynthesis Imaging

  • Fukui, Ryohei;Matsuura, Ryutaro;Kida, Katsuhiro;Goto, Sachiko
    • Progress in Medical Physics
    • /
    • v.32 no.2
    • /
    • pp.50-58
    • /
    • 2021
  • Purpose: In this study, we investigated the relationship between the noise characteristics and the number of projected images in tomosynthesis using a digital phantom. Methods: The digital phantom consisted of a columnar phantom in the center of the image and a spherical phantom with a diameter of 80 pixels. A virtual scan was performed, and 128 projected images (Tomo_w/o) of the phantoms were obtained. The image noise according to the Poisson distribution was added to the projected images (Tomo_×1). Furthermore, another projected image with additional noise was prepared (Tomo_×1/2). For each dataset, we created datasets with 64 (half) and 32 (quarter) projections by removing the even-numbered images twice from the 128 (fully) projected images. Tomosynthesis images were reconstructed by filtered back projection (FBP). The modulation transfer function (MTF) was estimated using the sphere method, and the noise power spectrum (NPS) was estimated using the two-dimensional Fourier transform method. Results: The MTFs did not change between datasets, and the NPSs improved as the number of projected images increased. The noise characteristics of the Tomo_×1_half images were the same as those of the Tomo_×1/2_full. Conclusions: To achieve a reduction in the patient dose in tomosynthesis acquisition, we recommend reducing the number of projected images rather than reducing the dose per projection.

Analysis of X-ray image qualities-accuracy of shape and clearness of image-using X-ray digital tomosynthesis

  • Roh, Young Jun;Kang, Sung Taek;Kim, Hyung Cheol;Kim, Sung-Kwon
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 1997.10a
    • /
    • pp.572-576
    • /
    • 1997
  • X-ray laminography and DT(digital tomosynthesis) that can form a cross-sectional image of 3-D objects promise to be good solutions for inspecting interior defects of industrial products. The major factors of the digital tomosynthesis that influence on the quality of x-ray cross-sectional images are also discussed. The quality of images acquired from the DT system varies according to image synthesizing methods, the number of images used in image synthesizing, and X-ray projection angles. In this paper, a new image synthesizing method named 'log-root method' is proposed to get clear and accurate cross-sectional images, which can reduce both artifact and blurring generated by materials out of focal plane. To evaluate the quality of cross-sectional images, two evaluating criteria: (1) shape accuracy and (2) clearness in the cross-sectional image are defined. Based on this criteria, a series of simulations were performed, and the results show the superiority of the new synthesizing method over the existing ones such as averaging and minimum method.

  • PDF

Tomosynthesis Feasibility Study for Visualization of Interiors of Wood Columns Surrounded with Walls

  • LEE, Jun Jae;KIM, Chul-Ki
    • Journal of the Korean Wood Science and Technology
    • /
    • v.50 no.4
    • /
    • pp.246-255
    • /
    • 2022
  • The need for non-destructive testing and evaluation of Korean traditional wooden buildings is increasing because of their widespread deterioration. Among all types of deterioration, termite damage in wooden columns is the most difficult to detect with the naked eye because it starts inside the wood, and the initial deterioration is small. X-ray computed tomography (CT) is the best technology to investigate the inner state of wood that has less damage, but applying it to wooden columns between walls is challenging. Therefore, the feasibility of tomosynthesis, which is a method to reconstruct a coronal section of a subject with a few X-ray projections from a limited angle of rotation, was studied as an alternative to CT. Pine (P. densiflora) with three artificial holes was prepared as a specimen to evaluate the quality of reconstructed tomosynthesis images according to the different number of projections. The quality of the tomosynthesis images in the in-focus plane was evaluated using the contrast-to-noise ratios, while a vertical resolution between the images was assessed by determining the artificial spread function. The quality of the tomosynthesis image in the in-focus plane increased as the number of projections increased and then remained constant as the number of projections reached 21 or over. In the case of vertical resolution, there was no significant difference when 21 projections or more were used to reconstruct the images. A distinct difference between coronal section images was found when the distance was more than 10 mm from one plane to another plane.

Evaluation of the Usefulness of Digital Tomosynthesis in the Chest (흉부영역에서 디지털 토모신테시스의 유용성 평가)

  • Jang, Dong-Hyuk;Shim, Sung-Shine;Choi, Jae-Wook;Choi, Jun-Gu
    • The Journal of the Korea Contents Association
    • /
    • v.12 no.10
    • /
    • pp.340-348
    • /
    • 2012
  • To evaluate the usefulness of tomosynthesis in the chest area, simple radiograph, low-dose CT, and tomosynthesis examinations were performed, and their absorbed doses were compared, and finally the images were evaluated. The absorbed dose recorded with the simple Radiograph examination was $0.33{\pm}0.27$ mGy, that of low-dose CT $1.26{\pm}0.56$ mGy, and that of tomosynthesis $0.55{\pm}0.02$ mGy, which indicate significance differences in absorbed doses among the examinations(p<0.001). Based on the evaluations of the images, The simple radiograph scores were $1.66{\pm}0.72$, $1.61{\pm}0.63$, and $1.57{\pm}0.73$, respectively; low-dose CT scores were $2.92{\pm}0.26$, $2.91{\pm}0.29$, and $2.88{\pm}0.32$, respectively; and tomosynthesis scores were $2.69{\pm}0.51$, $2.76{\pm}0.43$, and $2.66{\pm}0.61$, respectively. That is, there were statistically significant differences among the examinations(p<0.001), although there was no significant difference between low-dose CT and tomosynthesis examinations. Therefore, tomosynthesis is judged to be a useful examination that can minimize radiation doses to patients during chest examinations and enhance diagnostic efficacy.

Development of Image Reconstruction Algorithm for Chest Digital Tomosynthesis System (CDT) and Evaluation of Dose and Image Quality (흉부 디지털 단층영상합성 시스템의 영상 재구성 알고리즘 개발 및 선량과 화질 평가)

  • Kim, Min Kyoung;Kwak, Hyeng Ju;Kim, Jong Hun;Choe, Won-Ho;Ha, Yun Kyung;Lee, So Jung;Kim, Dae Ho;Lee, Yong-Gu;Lee, Youngjin
    • Journal of the Institute of Electronics and Information Engineers
    • /
    • v.53 no.9
    • /
    • pp.143-147
    • /
    • 2016
  • Recently, digital tomosynthesis system (DTS) has been developed to reduce overlap using conventional X-ray and to overcome high patient dose problem using computed tomography (CT). The purpose of this study was to develop image reconstruction algorithm and to evaluate image characteristics and dose with chest digital tomosynthesis (CDT) system. Image reconstruction was used for filtered back-projection (FBP) methods and system geometry was constructed ${\pm}10^{\circ}$, ${\pm}15^{\circ}$, ${\pm}20^{\circ}$, and ${\pm}30^{\circ}$ angular range for acquiring phantom images. Image characteristics carried out root mean square error (RMSE) and signal difference-to-noise ratio (SDNR), and dose is evaluated effective dose with ${\pm}20^{\circ}$ angular range. According to the results, the phantom image with slice thickness filter has superb RMSE and SDNR, and effective dose was 0.166 mSv. In conclusion, we demonstrated usefulness of developed CDT image reconstruction algorithm and we constructed CDT basic output data with measuring effective dose.

Enhancement of Image Sharpness in X-ray Digital Tomosynthesis Using Self-Layer Subtraction Backprojection Method (관심 단층 제거 후 역투사법을 이용한 X-선 디지털 영상합성법에서의 단층영상 선명도 향상에 관한 연구)

  • Shon, Cheol-Soon;Cho, Min-Kook;Lim, Chang-Hwy;Cheong, Min-Ho;Kim, Ho-Kyung;Lee, Sung-Sik
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.27 no.1
    • /
    • pp.8-14
    • /
    • 2007
  • X-ray digital tomosynthesis is widely used in the nondestructive testing and evaluation, especially for the printed circuit boards (PCBs). In this study, we propose a simple method to reduce the blur artefact, frequently claimed in the conventional digital tomosynthesis based on SAA (shift-and-add) algorithm, and thus restore the image sharpness. The proposed method is basically based on the SAA, but has a correction procedure by finding blur artefacts from the forward-and back-projection for the firstly obtained, manipulated backprojection data. The manipulation is the replacement of the original data at the POI (plane-of-interest) by zeros. This method has been compared with the conventional SAA algorithm using the experimental measurements and Monte Carlo simulation for the designed PCB phantom. The comparison showed a much enhancement of sharpness in the images obtained from the proposed method.

Design and Performance Improvement of a Digital Tomosynthesis System for Object-Detector Synchronous Rotation (물체-검출기 동기회전 방식의 X-선 단층영상시스템 설계 및 성능개선에 관한 연구)

  • Kang, Sung-Taek;Cho, Hyung-Suck;Roh, Byung-Ok
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.5 no.4
    • /
    • pp.471-480
    • /
    • 1999
  • This paper presents design and performance improvement of a new digital tomosynthesis (DTS) system for object-detector synchronous rotation. Firstly, a new DTS system, called OSDR (Object-Detector Synchronous Rotation) is suggested and designed to acquire X-ray digital images. Secondly, the shape distortion of DTS images generated by an image intensifier is modeled. And a new synthesis algorithm, which overcomes the limitations of the existing synthesis algorithm, is suggested to improve the sharpness of the synthesized image. Also an artifact analysis of the DTS system is performed. Thirdly, some performance indices, which evaluate quantitatively performance improvement, are defined. And the experimental verification of the performance improvement is accomplished by the ODSR system newly designed. The advantages of the ODSR system are expressed quantitatively, compared with an existing system.

  • PDF

Digital Breast Tomosynthesis in Addition to Conventional 2D-Mammography Reduces Recall Rates and is Cost-Effective

  • Agostino, Pozzi;Angelo, Della Corte;el Lakis, Mustapha A;Heon-Jae, Jeong
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.17 no.7
    • /
    • pp.3521-3526
    • /
    • 2016
  • Digital breast tomosynthesis (DBT) as a breast cancer screening modality, through generation of three-dimensional images during standard mammographic compression, can reduce interference from breast tissue overlap, increasing conspicuity of invasive cancers while concomitantly reducing false-positive results. We here conducted a systematic review on previous studies to synthesize the evidence of DBT efficacy, eventually 18 articles being included in the analysis. The most commonly emerging topics were advantages of DBT screening tool in terms of recall rates, cancer detection rates and cost-effectiveness, preventing unnecessary burdens on women and the healthcare system. Further research is needed to evaluate the potential impact of DBT on longer-term outcomes, such as interval cancer rates and mortality, to better understand the broader clinical and economic implications of its adoption.