• 제목/요약/키워드: tomography, x-ray computed

검색결과 697건 처리시간 0.035초

골결손부 치유과정에서 cone beam형 전산화단층영상의 정확도 (The accuracy of the imaging reformation of cone beam computed tomography for the assessment of bone defect healing)

  • 강호덕;김규태;최용석;황의한
    • Imaging Science in Dentistry
    • /
    • 제37권2호
    • /
    • pp.69-77
    • /
    • 2007
  • Purpose: To evaluate the accuracy of the imaging reformation of cone beam computed tomography for the assessment of bone defect healing in rat model. Materials and Methods: Sprague-Dawley strain rats weighing about 350 gms were selected. Then critical size bone defects were done at parietal bone with implantation of collagen sponge. The rats were divided into seven groups of 3 days, 1 week, 2 weeks, 3 weeks, 4 weeks, 6 weeks, and 8 weeks. The healing of surgical defect was assessed by multi planar reconstruction (MPR) images and three-dimensional (3-D) images of cone beam computed tomography, compared with soft X-ray radiograph and histopathologic examination. Results: MPR images and 3-D images showed similar reformation of the healing amount at 3 days, 1 week, 2 weeks, and 8 weeks, however, lower reformation at 3 weeks, 4 weeks, and 6 weeks. According to imaging-based methodologies, MPR image revealed similar reformation of the healing amount than 3-D images compare with soft X-ray image. Among the four threshold values for 3-D images, 400-500 HU revealed similar reformation of the healing amount. Histopathologic examination confirmed the newly formed trabeculation correspond with imaging-based methologies. Conclusion: MPR images revealed higher accuracy of the imaging reformation of cone beam computed tomography and cone beam computed tomography is a clinically useful diagnostic tool for the assessment of bone defect healing.

  • PDF

정상 성인의 좌심실 벽두께와 내강 크기에 대한 심초음파영상과 전산화단층영상의 비교 (Comparison of Echocardiography and Computed Tomography on Cardiac Wall Thickness and Internal Dimension Size of Left Ventricle in Normal Adults)

  • 지명훈;김성환;성열훈
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제41권6호
    • /
    • pp.545-552
    • /
    • 2018
  • The purpose of this study was evaluated the relationship between echocardiography and cardiac computed tomography in normal adults by visual assessment, and evaluated the effective doses of cardiac computed tomography. The subjects were 100 normal patients who visited two general hospitals in Chungnam, from January 1 to May 30, 2018. We obtained images by using these modalities and evaluated the wall thickness and internal dimension of the Left Ventricle with visual assessment. To evaluate the appropriateness of the visual evaluation, two evaluators who were trained for one week were measured and the agreement between the evaluators were verified by statistical analysis. The effective doses of computed tomography were evaluated using the dose length product. As a result, there was a high correlation between the two modalities. The agreement between the two visual evaluator were also highly agreed. The mean X-ray dose of the subjects was $11.1{\pm}3.1mSv$. Although the purpose of imaging is somewhat different in the clinical setting, echocardiography could achieve the same results as radiation-invasive computed tomography. It is thought that utilization will become even larger.

Physiologic Cervical Alignment Change between Cervical Spine X-ray and Computed Tomography

  • Lee, Ho Jin;Kim, Il Sup;Hong, Jae Taek
    • Journal of Korean Neurosurgical Society
    • /
    • 제64권5호
    • /
    • pp.784-790
    • /
    • 2021
  • Objective : The purpose of this study was to investigate the correlations among various radiological parameters used to determine cervical alignment from cervical spine radiographs (X-CS) and cervical spine computed tomography (CT-CS), both within and between modalities. Methods : This study included 168 patients (≤60 years old) without a definite whole spine deformity who underwent CT-CS and X-CS. We measured occipital slope (O-s), C1 slope, C2 slope, C7 slope, sella turcica - C7 sagittal vertical axis (StC7-SVA), spino-cranial angle, T1 slope, and C27-SVA. We calculated the O-C2 angle, O-C7 angle, and C2-7 angle from the measured parameters and conducted correlation analyses among multiple parameters. Results : The intrinsic correlation features among multiple cervical parameters were very similar for both X-CS and CT-CS. The two SVA parameters (C27-SVA and StC7-SVA) were mainly influenced by the upper cervical slope parameters (r=|0.13-0.74|) rather than the lower slope cervical parameters (r=|0.08-0.13|). The correlation between X-CS and CT-CS for each radiological parameter was statistically significant (r=0.26-0.44) except for O-s (r=0.10) and StC7-SVA (r=0.11). Conclusion : The correlation patterns within X-CS and CT-CS were very similar in this study. The correlation between X-ray and CT was statistically significant for most radiological parameters, and the correlation score increased when the horizontal gaze was consistently maintained. The lower cervical parameters were not statistically associated with translation-related parameters (C2-7 SVA and StC7-SVA). Therefore, the upper cervical segment may be a better predictor for determining head and neck translation.

전산화 단층촬영 영상 분석에 의한 탄소/탄소 목삽입재의 밀도 분포 측정 (Density Profile Measurement of Needle-punched Carbon/Carbon Nozzle Throat by the Analysis of Computed Tomography Image)

  • 김동륜;윤남균;이진용
    • 한국추진공학회:학술대회논문집
    • /
    • 한국추진공학회 2005년도 제25회 추계학술대회논문집
    • /
    • pp.469-474
    • /
    • 2005
  • 전산화 단층촬영법을 이용하여 탄소/탄소 목삽입재의 밀도 분포를 평가 하였다. 전산화 단층촬영 법의 Beam hardening, 전기적 잡음 및 산란 X-ray의 영상을 토정하고 신호 대 잡음비를 높여 최적화할 때 측정된 제작된 탄소/탄소 복합재료의 밀도는 98.74%의 신뢰도 수준에서 ${\pm}0.01g/cm^3$ 분포를 갖는 것으로 평가 되었다. 전산화 단층촬영 결과의 검증은 탄소/탄소 목삽입재를 절단하며 수침법에 의한 밀도 측정과 주사전자현미경 관찰을 통하여 수행되었으며 단층촬영결과는 수침법에 의한 밀도 분포와 주사전자현미경의 결과와 일치하였다.

  • PDF

Utility of the computed tomography indices on cone beam computed tomography images in the diagnosis of osteoporosis in women

  • Koh, Kwang-Joon;Kim, Kyoung-A
    • Imaging Science in Dentistry
    • /
    • 제41권3호
    • /
    • pp.101-106
    • /
    • 2011
  • Purpose : This study evaluated the potential use of the computed tomography indices (CTI) on cone beam CT (CBCT) images for an assessment of the bone mineral density (BMD) in postmenopausal osteoporotic women. Materials and Methods : Twenty-one postmenopausal osteoporotic women and 21 postmenopausal healthy women were enrolled as the subjects. The BMD of the lumbar vertebrae and femur were calculated by dual energy X-ray absorptiometry (DXA) using a DXA scanner. The CBCT images were obtained from the unilateral mental foramen region using a PSR-$9000N^{TM}$ Dental CT system. The axial, sagittal, and coronal images were reconstructed from the block images using $OnDemend3D^{TM}$. The new term "CTI" on CBCT images was proposed. The relationship between the CT measurements and BMDs were assessed and the intra-observer agreement was determined. Results : There were significant differences between the normal and osteoporotic groups in the computed tomography mandibular index superior (CTI(S)), computed tomography mandibular index inferior (CTI(I)), and computed tomography cortical index (CTCI). On the other hand, there was no difference between the groups in the computed tomography mental index (CTMI: inferior cortical width). Conclusion : CTI(S), CTI(I), and CTCI on the CBCT images can be used to assess the osteoporotic women.

요로결석 위치 진단에 대한 복부자세 변화에 따른 연구 (A Study on the Diagnosis of Urinary Stone Location by Abdominal Positioning Variations)

  • 김동진;채종상;유채민;이배원
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제41권1호
    • /
    • pp.7-12
    • /
    • 2018
  • Patients who visit the emergency room with urinary stones have difficulty lying down in a supine position due to severe pain when performing the KUB test. The purpose of this study was to find methods to reduce the patients' pain and image distortion, and obtain medical images with high diagnostic values. After checking the standard classification of disease and cause of death, the target group consisted of 121 patients who had clearly distinguished stones from computed tomography. Patients with stones in the ureteralvesical junction were excluded. Qualitative image evaluation was performed by confirming the location of the stone in the computed tomography images. and evaluated the rate of visual discrimination of stones possible through KUB and abdominal plain X-ray. Quantitative image evaluation was performed on the KUB, abdominal plain X-ray images. The transverse process of the first lumbar vertebrae served as the standard point, and the length from this point to the lower part of the stone was measured. Results from looking at the rate of visual discrimination of stones possible through KUB and abdominal plain X-ray showed: 94 patients (77.6%) for KUB images and 91 patients (75.2%) for computed tomography images. The standard deviation for KUB and abdominal X-ray was 3 (2.4%). Comparing and analyzing the location from KUB images and abdominal plain X-ray images, the stone position was 10.1 mm in the kidney, 10.5 mm in the ureteropelvic junction, and 9.7 mm in the ureters. It was shown that the stone moved 10 mm on average with significant statistical difference (P<0.05). In cases where the pain is so severe that it is impossible to perform the test in the supine position, an alternative may be to check the stone position by performing a modified KUB test by having the patient stand in a vertical position. In the future, this will provide convenience to both the examiner and the patient when performing the examination, and it will contribute with its reproducibility.

Microfocus X-ray CT Analysis of Shrinking Direction in Resin Composite.

  • Inai, N.;Katahira, N.;Hashimoto, K.;Tagami, J.;Hirakimoto, A.;Marshall, S.J.;Marshall. G.W.
    • 대한치과보존학회:학술대회논문집
    • /
    • 대한치과보존학회 2001년도 추계학술대회(제116회) 및 13회 Workshop 제3회 한ㆍ일 치과보존학회 공동학술대회 초록집
    • /
    • pp.559.1-559
    • /
    • 2001
  • The aim of the study was to determine the direction and the rate of polymerization shrinkage of light-cured resin composite. Materials and Methods: A microfocus x-ray CT(computed tomography) instrument (SMX-255CT, Shimadzu Co., Kyoto, Japan) was used to analyze and characterize the pre-and post-gel phases. A microfocus x-ray tube was used to enable a focus dimension of 4 microns.(omitted)

  • PDF

전산화단층촬영장치에서 링 아티팩트 제거 (Removal of Ring Artifact in Computed Tomography)

  • 천권수
    • 한국방사선학회논문지
    • /
    • 제9권6호
    • /
    • pp.403-408
    • /
    • 2015
  • 경엑스선은 물체의 내부구조 관찰에 유용하고 의료 및 산업분야에 광범위하게 사용되고 있다. 전산화단층촬영기법은 수백장의 투영영상을 이용하여 재구성함으로써 물체의 2차원 단면 영상을 얻을 수 있다. 단면 영상의 품질은 투영영상에 크게 의존한다. 투영영상을 얻는 검출기의 픽셀에 따라 링 아티팩트가 나타난다. 본 연구는 visual C++기반으로 한 원형 팬텀에서 검출기의 검출 에러에 따른 링 아티팩트 비를 조사하였다. 평행빔 및 부채살빔에서 링 아티팩트 비는 검출기의 검출 에러에 비례하여 나타났고, 회전 중심에 가까울수록 링 아티팩트는 강하게 나타났다. 전산화단층촬영의 단면 영상에서 링 아티팩트를 줄이기 위해서는 영상재구성 이전에 검출기의 보정이 필요함을 알 수 있었다.