• 제목/요약/키워드: toluene/hexane

검색결과 118건 처리시간 0.023초

확산포집기를 이용한 공기 중 유기용제 포집에 관한 연구 (A Study on Organic Solvent Measurement Using Diffusive Sampler)

  • 박미진;윤충식;백남원
    • 한국산업보건학회지
    • /
    • 제4권2호
    • /
    • pp.208-223
    • /
    • 1994
  • The purpose of this study was to evaluate the efficiency of diffusive(or passive) sampler in measuring airbone organic solvents. Diffusive samplers are generally simple in construction and do not require power for operation. The efficiency of the diffusive samplers has not sufficiently been investigated in Korea. Three types of samplers were studied in this study. The sampling and analytical results by passive samplers were compared with results by charcoal tube method recommended by NIOSH(National Institute for Occupational Safty and Health). The following characteristics are identified and studied as critical to the performance passive monitors; recovery, reverse diffusion, storage stability, accuracy and precision, face velocity and humidity, n-Hexane, TCE(trichloroethylene) and toluene were used as test vapors. A dynamic vapor exposure system consisting of organic vapor generator and sampling chamber for evaluating diffusive samplers are made. The results of the study are summarized as follows. 1. NIOSH recommands that the overall accuracy of a sampling method in the range of 0.5 to 2.0 times the occupational health standard should be ${\pm}25$ percent for 95 percent confidence level. Among three types of diffusive samplers, sampler A has permeation membrane and samplers Band C have diffusive areas, samplers A and B met the criterion that overall accuracy for 95% confidence level of the samplers were within ${\pm}25$ percent of the reference value. Sampler C had overall accuracy ${\pm}9.6%$ and ${\pm}11.8%$ in hexane and TCE, respectively. The concentration of toluene was overestimated in sampler C with overall accuracy of ${\pm}43.9%$. 2. The desorption efficiencies of diffusive samplers were 96-107%. 3. There was no significant sampe loss during four weeks of storage both with and without refrigeration. 4. There was no significant reverse diffusion, when the samplers were exposure to clean air for 2 hours after sampling for 2 hours at the level of 2 TLY. 5. In case of 8 hours sampling, relative differences(RD) of concentrations between charcoal tube method and diffusive method were 15-39%, 13-46%, and 4-35% for sampler A, B and C, respectively. The performance was poor in 8 hours sampling for multiple substance monitors. 6. At high velocity(100 cm/sec), samplers B and C overestimated the concentrations of organic vapors, and sampler A with permeation membrance gave better results. 7. At 80% relative humidity, samplers showed no siginificant effect. Low humidity also did not affect the diffusive samplers.

  • PDF

모 공단 대기 중 휘발성 유기화합물 측정에 관한 연구 (The study on the measurement of volatile organic compounds in the air of A and B industrial area)

  • 신호상;안혜실
    • 분석과학
    • /
    • 제17권2호
    • /
    • pp.130-144
    • /
    • 2004
  • 최근 A, B 공단지역 및 주변 지역의 대기오염문제가 중요한 이슈가 됨에 따라 이 지역의 대기 중 VOCs를 측정하였다. 시료는 air sampler를 사용하여 Carbotrap에 흡착시킨 후 열탈착시스템을 사용하여 탈착시켜 가스크로마토그래피/질량분석법(GC/MS)으로 분석하였다. 모든 휘발성유기화합물들은 좋은 크로마토그래프 성질을 보였고 GC/MS-SIM에서 높은 감도를 보였다. 검출한계는 0.01-0.1 ppt(v/v)를 검량선의 직선성은 0.995이상을 보였다. 분석 결과 benzene, toluene, ethylbenzene, xylene, n-hexane, fluorotrichloromethane, carbon tetrachloride, 1,2-dichloroethane, 1,1,1-trichloroethane, trichloroethylene, tetrachloroethylene, styrene, 1,3,5-trimethylbenzene, 1,2,4-trimethylbenzene, sec-butylbenzene, naphthalene 등 16개의 VOCs가 검출되었으며, 평균 농도로서 0.81, 5.02 1.30, 3.0, 0.81, 37.9, 0.07, 0.15, 0.15, 0.79, 0.06, 0.33, 0.03, 0.12, 0.23 그리고 0.35 ppb(v/v)으로 나타났다. 전반적으로 총 VOCs의 농도는 여름철보다 가을 및 겨울철에 더 높게 검출되었으나 WHO의 기준치를 초과한 경우는 없었다.

알루미늄클로라이드 촉매를 이용한 Tricyclopentadiene 유도체의 이성화 반응 연구(I) (A Study on the Isomerization Reactions of Tricyclopentadiene Derivatives Using Aluminum Chloride(AlCl3) Catalyst(I))

  • 주현혜;권태수;박창선;한정식
    • 한국추진공학회지
    • /
    • 제16권2호
    • /
    • pp.17-24
    • /
    • 2012
  • Tetrahydrotricyclopentadiene(이하 THTCPD)의 이성질체는 높은 밀도와 높은 발열량을 가지고 있어 고성능 액체 연료의 주요성분물질로 활용이 가능하다. 본 연구에서는 상온에서 고체 상태로 유동성이 좋지 않은 THTCPD를 유동성이 우수한 액체상태 특성을 가질 수 있게 할 수 있는 최적의 반응조건을 찾는 것이다. THTCPD의 이성화 반응은 반응온도 변화와 반응용매의 영향 등의 다양한 반응조건을 통해 살펴보았다. 알루미늄클로라이드 촉매를 사용하여 THTCPD 이성화 반응을 실험한 결과 Dichloromethane(Methylene Chloride: MC), 1,2-Dichloroethane(Ethylene Chloride: EC), Chloroform과 같은 할로겐 함유 극성용매가 n-Hexane, Toluene과 같은 비극성 탄화수소형 용매보다 이성화 반응에서 우수한 특성을 나타내었으며, 반응온도의 변화도 이성화반응에 크게 영향을 미치는 것을 알 수 있었다.

알루미늄클로라이드 촉매를 이용한 Tricyclopentadiene 유도체의 이성화 반응 연구(I) (A Study on the isomerization reactions of Tricyclopentadiene Derivatives using aluminum chloride($AlCl_3$) catalyst(I))

  • 주현혜;주형욱;박창선;한정식
    • 한국추진공학회:학술대회논문집
    • /
    • 한국추진공학회 2010년도 제35회 추계학술대회논문집
    • /
    • pp.800-803
    • /
    • 2010
  • Tetrahydrotricyclopentadiene(이하 THTCPD)의 이성질체는 높은 밀도와 높은 발열량을 가지고 있어 고성능 액체 연료의 주요성분으로 활용이 가능하다. 본 연구에서는 상온에서 고체상태로 유동성이 좋지 않은 THTCPD를 흐름성이 우수한 액체상태 특성을 가질 수 있게 할 수 있는 최적의 반응조건을 찾는 것이다. THTCPD의 이성화 반응은 반응온도 변화와 반응용매의 영향 등의 다양한 반응조건을 통해 살펴보았다. 알루미늄클로라이드 촉매를 사용하여 실험한 결과 사용한 반응용매 중 Dichloromethane(Methylene Chloride: MC), 1,2-Dichloroethane(Ethylene Chloride: EC), Chloroform이 n-Hexane, Toluene보다 이성화 반응에서 우수한 특성을 나타내었으며, 반응온도도 이성화반응에 영향을 크게 미치는 것을 알 수 있었다.

  • PDF

사업장 자체측정기관 국내, 외 정도관리 참여 결과 (The Result of Quality Control in POSCO's Industrial Hygiene Laboratory)

  • 이영세;이송권;조기현;채종홍;김용래
    • 한국산업보건학회지
    • /
    • 제5권1호
    • /
    • pp.87-103
    • /
    • 1995
  • Since being granted permission for self-assessment of the work environment by the Department of Labor in 1992, POSCO's Industrial Hygiene Laboratory has participated in domestic and Foreign Quality Control Programs 8 times and has obtained remarkable results. It has made a lot of effort to be a proficient laboratory with the ability to observe and analyse environmental monitoring data. The summary of results is as follows: 1. POSCO's Industrial Hygiene Laboratory has received a "P(Proficient)" grade from the round 115 to round 119 of AIHA/NIOSH PAT Program for analysis of such metals as lead, cadmium, zinc, and chromium, and also has received a "P(Proficient)" grade from its round 119 of for organic solvent analysis, i,e,. Trichloroethylene(TCE), Carbon Tetr-achloride(CTC), 1,2-Dichloroethane(DCE), 1,1,1-Trichloroethane(MCM), Tetrachloroethylene (PCE), Chloroform(CFM), Benzene(BNZ), toluene(TOL), and O-xylene(OXY). 2. In the Quality Control Evaluation Program performed by the Industrial Health Research Institute,Korea Industrial Safety Corporation, POSCO has passed impressively in the3-metal analysis test for lead, cadmium, cupper, and in the 6 organic solvent analysis test for Benzene(BNZ), toluene(TOL), O-xylene(OXY), Trichloroethylene(TCE) and Methyl isobutyl keton(MIBK), n-Hexane with 2 standard deviations. These analytic techniques should be practically applied to various fields, and reliable results of environmental monitoring should be considered to improve the work environment and to keep workers from occupation related diseases.

  • PDF

복합유기용제의 누적 폭로 정도에 따른 신경행동학적 변화 (Neurobehavioral Changes according to Cumulative Exposure of Complex Organic Solvents)

  • 이덕희;박인근;김진하;이용환;강성규;김두희
    • Journal of Preventive Medicine and Public Health
    • /
    • 제28권2호
    • /
    • pp.386-397
    • /
    • 1995
  • A cross sectional study was performed to evaluate the neurobehavioral effects of chronic exposure of complex organic solvents, using NCTB(Neurobehavioral Core Test Battery) recommended by WHO(World Health Organization). Forty female shoe factory workers and twenty-two controls matched with age were participated. The tests were performed in the morning before start of work, to exclude the effects of acute exposure. Workers were exposed mainly to toluene, methyl ethyl ketone, n-hexane, cyclo-hexane, dichloroethylene, trichloroethylene, benzene, xylenes etc. The ranges of present solvent exposure of hygienic effect were $0.46\sim0.71$ in the process using adhesives indirectly, and $1.83\sim2.39$ in the process using it directly. We reclassified the subjects, according to cumulative exposure. It showed significantly poorer performances in high exposed group on Santa Ana Dexterity and Benton Visual Retention, compared with control group. After controlling confounder, the significances were still remained. But, further cohort studies, having the information of personal exposure dose from entering a factory, are required to clarify the effects of chronic exposure of complex organic solvents in relation to dose and duration of exposure.

  • PDF

확산형포집기(3M OVM #3500)와 활성탄관의 유기용제 포집농도 비교 및 확산형포집기의 현장 적용 가능성 (Comparison between the Charcoal Tube Sampling Method and the Diffusive Sampler, and the Applicability of Diffusive Sampler in the Field)

  • 장성호;김형아
    • 한국산업보건학회지
    • /
    • 제15권3호
    • /
    • pp.261-269
    • /
    • 2005
  • To investigate the field applicability of a diffusive sampler (3M OVM #3500, passive sampling method) authors conducted a simultaneous measurement of personal organic solvents exposure in the air of the workplaces by charcoal tube with low volume sampler (active sampling method) and diffusive sampler. Samples were collected and analyzed by NIOSH method ($NMAM^{(R)}$) from thirty-eight workers in 12 factories who work in 6 different processes. Geometric mean (GM) and geometric standard deviation (GSD) were used to describe the result. To compare the results of the two methods, paired t-test was used. According to the manual of the exposure assessment of the mixed organic solvents (Ministry of Labor, Korea), Em was calculated. Simple linear regression was used to evaluate the relationship between the two methods. Results were as follows; 1. Eight different solvents (ethyl acetate, n-hexane, toluene, xylene, acetone, isopropyl alcohol, methyl ethyl ketone (MEK), and methyl isobutyl ketone) were detected simultaneously in the two methods and the concentrations of the personal exposure were lower than 0.5 TLV level. The concentration of the charcoal tube method was higher than that of a diffusive sampler in n-hexane and MEK (p<0.05). 2. Em of the charcoal tube method was higher than that of diffusive sampler method but not significantly different and was lower than the OEL (Occupational Exposure Limit) in all 6 processes. 3. There was a significant correlation between the two methods in low concentrations of the 8 organic solvents (p<0.05). In conclusion, there was no difference in charcoal tube method and diffusive sampler method in low concentrations of some organic solvents, diffusive sampler can be applied to assess the personal monitoring in low level exposure.

Occupational Neurotoxic Diseases in Taiwan

  • Liu, Chi-Hung;Huang, Chu-Yun;Huang, Chin-Chang
    • Safety and Health at Work
    • /
    • 제3권4호
    • /
    • pp.257-267
    • /
    • 2012
  • Occupational neurotoxic diseases have become increasingly common in Taiwan due to industrialization. Over the past 40 years, Taiwan has transformed from an agricultural society to an industrial society. The most common neurotoxic diseases also changed from organophosphate poisoning to heavy metal intoxication, and then to organic solvent and semiconductor agent poisoning. The nervous system is particularly vulnerable to toxic agents because of its high metabolic rate. Neurological manifestations may be transient or permanent, and may range from cognitive dysfunction, cerebellar ataxia, Parkinsonism, sensorimotor neuropathy and autonomic dysfunction to neuromuscular junction disorders. This study attempts to provide a review of the major outbreaks of occupational neurotoxins from 1968 to 2012. A total of 16 occupational neurotoxins, including organophosphates, toxic gases, heavy metals, organic solvents, and other toxic chemicals, were reviewed. Peer-reviewed articles related to the electrophysiology, neuroimaging, treatment and long-term follow up of these neurotoxic diseases were also obtained. The heavy metals involved consisted of lead, manganese, organic tin, mercury, arsenic, and thallium. The organic solvents included n-hexane, toluene, mixed solvents and carbon disulfide. Toxic gases such as carbon monoxide, and hydrogen sulfide were also included, along with toxic chemicals including polychlorinated biphenyls, tetramethylammonium hydroxide, organophosphates, and dimethylamine borane. In addition we attempted to correlate these events to the timeline of industrial development in Taiwan. By researching this topic, the hope is that it may help other developing countries to improve industrial hygiene and promote occupational safety and health care during the process of industrialization.

유기합성실험실 연구자의 단위작업별 노출 평가 (Task-based Exposure Assessment among Laboratory workers in Organic Synthesis Laboratories)

  • 최영은;추연희;이익모;박정임
    • 한국산업보건학회지
    • /
    • 제29권1호
    • /
    • pp.1-12
    • /
    • 2019
  • Objective: Significant concerns have been raised over chemical exposure and potential health risks such as increased cancer mortality among laboratory workers. The aim of this study was to investigate the overall exposure and unit task exposure levels of researchers in organic synthesis laboratories at universities. Methods: Seventy-seven personal Time-weighted average(TWA) samples and 139 task-based samples from four organic synthesis laboratories at two universities were collected over three days. The concentrations of acetone, chloroform, dichloromethane(DCM), diethyl ether, ethyl acetate, n-hexane, tetrahydrofuran(THF), benzene, toluene, and xylene were determined using the GC-FID. Results: The most frequently used chemicals in the laboratories were acetone, DCM, n-hexane, methanol, and THF. Carcinogens such as benzene, chloroform, and DCM were used in one or more laboratories. The TWA full-shift exposures of researchers to acetone was the highest(ND-59.3 ppm). Benzene was observed above the occupational exposure limit in 18-40% of the samples. The levels of exposure to organic solvents were statistically different by task(p<0.05), while washing task was the highest. Washing was not perceived as a part of the real lab tasks. Rather it was considered as simple dish-washing or experimental preparation and performed in an open sink where exposure to organic solvents was unavoidable. TWAs and task-based concentrations were compared by substance, which suggests that TWA-based assessment could not reflect short-term and high concentration exposures. Conclusions: Laboratory workers may be exposed to various organic solvents at levels of concern. TWA-based measurement alone cannot guarantee holistic exposure assessment among lab workers as their exposures are very dependent on their tasks. Further investigation and characterization for specific tasks and overall chronic exposures will help protect lab workers from unnecessary exposure to chemicals while they perform research.

효소 및 미생물의 고정화에 관한 연구 제1보. 방사선조사에 의한 Glucose Oxidase의 고정화법 (Studies on the Immobilization of Enzymes and Microoganism Part 1. Immobilizing Method of Glucose Oxidase by Gamma Radiation)

  • Kim, Sung-Kih
    • 한국미생물·생명공학회지
    • /
    • 제7권1호
    • /
    • pp.1-8
    • /
    • 1979
  • 혈액 및 생체반응물질등에 함유된 미량의 glucose를 효소적으로 간편하게 측량하기 위하여 먼저 고가의 glucose oxidase를 고정화 시켰다. 전리 방사선조사에 의하여 이 효소를 쉽게 고정화 시킬수 있는 방법과 그 알맞는 조건 및 높은 잔여 활성에 관한 결과는 다음과 같다. 1) 여러가지 monomer 및 polymer의 combination 중에서 AA-Bis, NK ester 23G, 물 (1:1:2)에 가용성 효소 1ml를 고정화 시켰을 경우를 비롯하여 GOD의 잔여활성이 50%이상인 여러 monomer Combination 찾았다 2) Carrier의 방사선중합에 필요한 선량은 100 krad 이상 이였으나, 400~500krad가 적당하였고, solvent는 toluene, n-haxane, petoleum ether chloroform 등을 이용할 때 고정화된 GOD의 잔여 활성 및 이화학적 성장이 좋았다. 3) GOD 고정화에 이용될 수 있는 완충 용액은 tris-glycerol buffer (pH 7.0)가 phosphate (pH 7.0) 보다 높은 활성을 보여 주었다. 4) 고정화된 GOD의 최적 pH는 6.0~6.5 또 온도는 30~4$0^{\circ}C$로서 가용성 효소보다 작용범위가 넓었고, pH 및 온도의 변화도 완만하였다. The author acknowledges with gratitude financial assistance from International Atomic Energy Agency, Vienna, Austria and also sincerely thanks Dr. K. Kawashima and his colleagues, National Food Research Institute, Tokyo, Iapan for encouragement and assistance.

  • PDF