• 제목/요약/키워드: titanium surface

검색결과 1,169건 처리시간 0.027초

다양한 치태조절기구가 타이타늄 임프란트의 표면조도와 형태에 미치는 영향 (The Effect of Various Plaque Control Devices on Roughness and Morphology of Titanium Implant Surface)

  • 최승환;임정수;송인택;김형섭
    • Journal of Periodontal and Implant Science
    • /
    • 제28권2호
    • /
    • pp.337-350
    • /
    • 1998
  • The purpose of this' study was to compare surface roughness and morphologic changes after use of various plaque control devices to titanium implant surfaces. The study materials were 6 ITI titanium implants($Bonefit^{(R)}$) and 5 plaque control devices. 6 implants were divided into 6 different groups and instrumented by each plaque control devices as follows. 1) Group I : untreated control 2) Group II : Titanium curette(Titanium $curette^{(R)}$, 3i) 80 vertical/horizontal strokes 3) Group III : Plastic curette($Implacare^{(R)}$, Hu-Friedy) 80 vertical/horizontal strokes 4) Group N : Plastic tip-ultrasonic scaler($Amdent^{(R)}$, Amdent) 160 seconds 5) Group V : Rotating interdental brush($Identobrush^{(R)}$, Identoflex) 160 seconds 6) Group VI : Abrasive rubber cup polisher($Zircate^{(R)}$, Prophy paste, Dentsply) 160 sec-onds. All specimens were prepared for evaluation by surface roughness tester, optical stereomicroscopy(OM) and scanning electron microscopy(SEM). The Ra and Rt mean values of the tested specimens were 1) Group I ($Ra=0.170{\pm}0.007{\mu}m$, $Rt=1.297{\pm}0.016{\mu}m$) 2) Group II ($Ra=0.209{\pm}0.006{\mu}m$, $Rt=1.602{\pm}0.110{\mu}m$) 3) Group III ($Ra=0.179{\pm}0.001{\mu}m$, $Rt=1.429{\pm}0.055{\mu}m$) 4) Group IV ($Ra=0.182{\pm}0.005{\mu}m$, $Rt=1.511{\pm}0.085{\mu}m$) 5) Group V ($Ra=0.301{\pm}0.008{\mu}m$, $Rt=1.882{\pm}0.131{\mu}m$) 6) Group VI ($Ra=0.147{\pm}0.010{\mu}m$, $Rt=1.059{\pm}0.021{\mu}m$) In Ra values, experimental group II, V, VI were statistically significant different when compared with control. OM and SEM observation showed that experimental group III, IV were minimal changes when compared with control and group VI was smoothest among other experimental groups. The results suggested that plastic curette and plastic tip-ultrasonic scaler were predictable devices to titanium implant surface.

  • PDF

전자빔 증착법에 의한 티타늄 전극 구조 염료 태양전지 제작에 관한 연구 (A Study on the Fabrication of Dye-Sensitized Solar Cells Consisting of Ti Electrodes by Electron-beam Evaporation Method)

  • 김윤기;심충환;김현규;성열문;김동현;이해준;박정후;이호준
    • 전기학회논문지
    • /
    • 제59권4호
    • /
    • pp.754-758
    • /
    • 2010
  • In general, Dye-sensitized Solar Cells(DSCs) consist of the nanocrystalline titanium dioxide($TiO_2$) layer which is fabricated on a transparent conductive oxide(TCO) layer such as $F/SnO_2$ glass, a dye adhered to the $TiO_2$, an electrolyte solution and platinum-coated TCO. Among these components, two TCO substrates are estimated to be about 60% of the total cost of the DSCs. Currently novel TCO-less structures have been investigated in order to reduce the cost. In this study, TCO-less DSCs consisting of titanium electrodes were investigated. The titanium electrode is deposited on top of the porous $TiO_2$ layer using electron-beam evaporation process. The porosity of the titanium electrode was found out by the SEM analysis and dye adhesion. As a result, when the thickness of the titanium electrode increased, the surface resistance decreased and the conversion efficiency increased relatively.

Cyanide removal simulation from wastewater in the presence of titanium dioxide nanoparticles

  • Safavi, Banafshe;Asadollahfardi, Gholamreza;Darban, Ahmad khodadadi
    • Advances in nano research
    • /
    • 제5권1호
    • /
    • pp.27-34
    • /
    • 2017
  • One of the methods of removing cyanide from wastewater is surface adsorption. We simulated the removal of cyanide from a synthetic wastewater in the presence of Titanium dioxide nano-particles absorbent uses VISUAL MINTEQ 3.1 software. Our aim was to determine the factors affecting the adsorption of cyanide from synthetic wastewater applying simulation. Synthetic wastewater with a concentration of 100 mg/l of potassium cyanide was used for simulation. The amount of titanium dioxide was 1 g/l under the temperature of $25^{\circ}C$. The simulation was performed using an adsorption model of Freundlich and constant capacitance model. The results of simulation indicated that three factors including pH, nanoparticles of titanium dioxide and the primary concentration of cyanide affect the adsorption level of cyanide. The simulation and experimental results had a good agreement. Also by increasing the pH level of adsorption increases 11 units and then almost did not change. An increase in cyanide concentration, the adsorption level was decreased. In simulation process, rising the concentrations of titanium dioxide nanoparticles to 1 g/l, the rate of adsorption was increased and afterward no any change was observed. In all cases, the coefficient of determination between the experimental data and simulation data was above 0.9.

Acidic Properties and Catalytic Activity of Titanium Sulfate Supported on TiO2

  • Sohn, Jong-Rack;Lee, Si-Hoon;Cheon, Park-Won;Kim, Hea-Won
    • Bulletin of the Korean Chemical Society
    • /
    • 제25권5호
    • /
    • pp.657-664
    • /
    • 2004
  • Titanium sulfate supported on $TiO_2$was prepared by impregnation of powdered $TiO_2$with an aqueous solution of titanium sulfate followed by calcining in air at high temperature. For Ti$(SO_4)_2/TiO_2$ samples calcined at 300 $^{\circ}C$, no diffraction lines of titanium sulfate are observed at $Ti(SO_4)_2$loading up to 30 wt%, indicating good dispersion of $Ti(SO_4)_2$ on the surface of $TiO_2$. The acidity of the catalysts increased in proportion to the titanium sulfate content up to 20 wt% of $Ti(SO_4)_2$. 20 wt% $Ti(SO_4)_2/TiO_2$ calcined at 300 $^{\circ}C$ exhibited maximum catalytic activities for 2-propanol dehydration and cumene dealkylation. The catalytic activities for these reactions, were correlated with the acidity of catalysts measured by ammonia chemisorption method.

Thermal Decomposition of Tetrakis(ethylmethylamido) Titanium for Chemical Vapor Deposition of Titanium Nitride

  • Kim, Seong-Jae;Kim, Bo-Hye;Woo, Hee-Gweon;Kim, Su-Kyung;Kim, Do-Heyoung
    • Bulletin of the Korean Chemical Society
    • /
    • 제27권2호
    • /
    • pp.219-223
    • /
    • 2006
  • The thermal decomposition of tetrakis(ethylmethylamido) titanium (TEMAT) has been investigated in Ar and $H_2$ gas atmospheres at gas temperatures of 100-400 ${^{\circ}C}$ by using Fourier Transform infrared spectroscopy (FTIR) as a fundamental study for the chemical vapor deposition (CVD) of titanium nitride (TiN) thin film. The activation energy for the decomposition of TEMAT was estimated to be 10.92 kcal/mol and the reaction order was determined to be the first order. The decomposition behavior of TEMAT was affected by ambient gases. TEMAT was decomposed into the intermediate forms of imine (C=N) compounds in Ar and $H_2$ atmosphere, but additional nitrile (RC$\equiv$N) compound was observed only in $H_2$ atmosphere. The decomposition rate of TEMAT under $H_2$ atmosphere was slower than that in Ar atmosphere, which resulted in the extension of the regime of the surface reaction control in the CVD TiN process.

질소이온 주입이 생체적합성 티타늄 임플란트의 마모특성에 미치는 영향 (Effect of Nitrogen Ion Implantation on Wear Behavior of Biocompatible Ti Implant)

  • 변응선;김동수;이구현;정용수
    • 연구논문집
    • /
    • 통권30호
    • /
    • pp.137-145
    • /
    • 2000
  • Since the concept of osseointegration was introduced, titanium and titanium-based alloy materials have been increasingly used for bone-anchored metal in oralmaxillofacial and orthopedic reconstruction. Successful osseointegration has been attributed to biocompatibility and surface condition of metal implant among other factors. Although titanium and titanium alloys have an excellent over the metal ion release and biocompatibility, considerable controversy has developed over the metal ion and wear debris in vivo and vitro. In this study, nitrogen ion implantation technique was used to improve the corrosion resistance and wear property of titanium materials, ultimately to enhance the tissue reaction to titanium implants As ion implantation energy was increased, projected range of nitrogen ion the Ti substrate was gradually increased. Under condition of constant ion energy. atomic concentration of nitrogen was also increased with ion doses. The friction in Hank's solution was increased with ion doses. The friction coefficient of ion implanted specimens in HanK's solution was increased from 0.39, 0.47 to 0.52, 0.65 respectively under high energy and ion dose conditions. As increasing ion energies and ion dose, amount of wear was reduced.

  • PDF

이중층 티타늄 전극으로 구성된 TCO-less 염료감응형 태양전지 제작에 관한 연구 (Fabrication of Transparent Conductive Oxide-less Dye-Sensitized Solar Cells Consisting of Titanium Double Layer Electrodes)

  • 심충환;김윤기;김동현;이해준;이호준
    • 전기학회논문지
    • /
    • 제60권1호
    • /
    • pp.114-118
    • /
    • 2011
  • Dye-Sensitized Solar Cells(DSSCs) consist of a titanium dioxide($TiO_2$) nano film of the photo electrode, dye molecules on the surface of the $TiO_2$ film, an electrolyte layer and a counter electrode. But two transparent conductive oxide(TCO) substrates are estimated to be about 60[%] of the total cost of the DSSCs. Currently novel TCO-less structures have been investigated in order to reduce the cost. In this study, we suggested a TCO-less DSSCs which has titanium double layer electrodes. Titanium double layer electrodes are formed by electron-beam evaporation method. Analytical instruments such as electrochemical impedance spectroscopy, scanning electron microscope were used to evaluate the TCO-less DSSCs. As a result, the proposed structure decreases energy conversion efficiency and short-circuit current density compared with the conventional DSSCs structure with FTO glass, while internal series impedance of TCO-less DSSCs using titanium double layer electrodes decreases by 27[%]. Consequently, the fill factor is improved by 28[%] more than that of the conventional structure.

MMO(Ti/Ru) 코팅된 타이타늄의 고분자 전해질 연료전지 양극환경에서의 전기화학적 거동 (Electrochemical Characteristics of MMO(Ti/Ru)-Coated Titanium in a Cathode Environment of Polymer Electrolyte Membrane Fuel Cell)

  • 허호성;김성종
    • Corrosion Science and Technology
    • /
    • 제21권5호
    • /
    • pp.340-347
    • /
    • 2022
  • In this research, mixed metal oxide (TiO2, RuO2) coating was applied to grade 1 titanium as a bipolar plate for polymer electrolyte membrane fuel cell (PEMFC). Electrochemical experiments were carried out in an aqueous solution of pH 3 (H2SO4 + 0.1 ppm HF, 80 ℃) determined by DoE. The air was bubbled to simulate a cathode environment. Potentiodynamic polarization test revealed that corrosion current densities of the titanium substrate and MMO-coated specimen were 0.180 µA/cm2 and 4.381 µA/cm2, respectively. There was no active peak. After potentiostatic experiment, current densities of the titanium substrate and the MMO-coated specimen were 0.19 µA/cm2 and 1.05 µA/cm2, respectively. As a result of observing the surface before and after the potentiostatic experiment, cracked dried clay structures were observed without corrosion damage. Both the titanium substrate and the MMO-coated specimen could not satisfy the interfacial contact resistance suggested by the DoE. Thus, further research is needed before they could be applied as bipolar plates.

표면처리가 장갑재료의 방호한계에 미치는 영향 (An Effect of surface treatment on a Protection Ballistic Limits in armor material)

  • 손세원;김희재;이두성;홍성희;유명재
    • 한국정밀공학회지
    • /
    • 제20권12호
    • /
    • pp.126-134
    • /
    • 2003
  • In order to investigate the effect of surface treatment in Aluminium alloy and Titanium alloy which are used to armor material during ballistic impact, a ballistic testing was conducted. Anodizing was used to achieve higher surface hardness of Aluminium alloy and Iron plating in PVD(Physical Vapor Deposition) method was used to achieve higher surface hardness of Titanium alloy. Surface hardness test were conducted using a Micro victor's hardness tester. Ballistic resistance of these materials was measured by protection ballistic limit(V-50), a statical velocity with 50% probability penetration. Fracture behaviors and ballistic tolerance, described by penetration modes, are respectfully observed from the results of V-50 test and Projectile Through Plates (PTP) test at velocities greater than V-50. PTP tests were conducted with 0$^{\circ}$obliquity at room temperature using 5.56mm ball projectile. V-50 tests were conducted with 0$^{\circ}$obliquity at room temperature with projectiles that were able to achieve near or complete penetration during PTP tests. Surface hardness, resistance to penetration. and penetration modes of surface treated alloy laminates are compared to those of surface non-treated alloy laminates. A high speed photography was used to analyze the dynamic perforation phenomena of the test materials.