• Title/Summary/Keyword: tip shape

Search Result 572, Processing Time 0.023 seconds

Formation of Switching Zones in an AFM Tip/Ferroelectric Thin Film/BE System (AFM팁/강유전박막/전극 시스템에서의 스위칭 영역의 형성)

  • Kim, Sang-Joo;Shin, Joon-Ho;Kim, Yun-Jae
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.27 no.6
    • /
    • pp.849-856
    • /
    • 2003
  • A three-dimensional constitutive model for polarization switching in ferroelectric materials is used to predict the formation of switching zones in an atomic force microscopy(AFM) tip/ferroelectric thin film/bottom electrode system via finite element simulation. Initially the ferrolectric film is poled upward and the bottom electrode is grounded. A strong dc field is imposed on a fixed point of the top surface of the film through the AFM tip. A small switching zone with downward polarization is nucleated and grows with time. It is found that initially the shape of the switched zone is that of a bulgy dagger, but later turn to the shape of a reversed cup with the lower part wider than the upper part. It can also be concluded that the size of switching zones increases with the period of applied electric potential. The present results are qualitatively consistent with experimental observations.

Study on Noise Reduction of an Axial Fan for Refrigerator through Modification of the Blade Tip (깃 끝단 개선을 통한 냉장고용 축류홴 저소음화에 대한 연구)

  • 김창준;전완호;정용규
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2002.05a
    • /
    • pp.639-644
    • /
    • 2002
  • In this paper, a successful noise reduction of an axial flow fan for a refrigerator is presented. The vortex sheet generated at the blade tip of fan was suppressed by changing the shape of the tip. The structure of vortex sheet and detailed flow pattern around the fan were studied by two-dimensional LDV(Laser-Doppler Velocimetry). Effective ways to work out the result as mentioned above are to make the tip of the blade varied in thickness and to have elliptical shapes. To seek the optimal value fur the shape of new fan, several cases were examined. Through the application of the methods, the refrigerator became less noisy by 3.8 dB(A) in terms of air-borne noise produced only by the axial flow fan compared to the current one.

  • PDF

Infleunce of Nozzle Tip Size on the Preparation of Nano-Sized Tin Oxide Powder by Spray Pyrolysis Process

  • Yu, Jaekeun;Kim, Donghee
    • Korean Journal of Materials Research
    • /
    • v.23 no.2
    • /
    • pp.81-88
    • /
    • 2013
  • In this study, using a tin chloride solution as the raw material, a nano-sized tin oxide powder with an average particle size below 50 nm is generated by a spray pyrolysis process. The properties of the tin oxide powder according to the nozzle tip size are examined. Along with an increase in the nozzle tip size from 1 mm to 5 mm, the generated particles that appear in the shape of droplets maintain an average particle size of 30 nm. When the nozzle tip size increases from 1 mm to 2 mm, the average size of the generated particles is around 80-100 nm, and the ratio of the independent particles with a compact surface structure increases significantly. When the nozzle tip size is at 3 mm, the majority of the generated particles maintain the droplet shape, the average size of the droplet-shaped particles increases remarkably compared to the cases of other nozzle tip sizes, and the particle size distribution also becomes extremely irregular. When the nozzle tip size is at 5 mm, the ratio of droplet-shaped particles decreases significantly and most of the generated particles are independent ones with incompact surface structures. Along with an increase in the nozzle tip size from 1 mm to 3 mm, the XRD peak intensity increases, whereas the specific surface area decreases greatly. When the nozzle tip size increases up to 5 mm, the XRD peak intensity decreases significantly, while the specific surface area increases remarkably.

Improvement of the Carbon Nanotube Tip by Focused Ion Beam and it Performance Evaluation (탄소나노튜브 팁의 집속이온빔에 의한 개선 및 성능 평가)

  • Han, Chang-Soo;Shin, Young-Hyun;Yoon, Yu-Hwan;Lee, Eung-Sug
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.31 no.1 s.256
    • /
    • pp.139-144
    • /
    • 2007
  • This paper presents development of carbon nanotube (CNT) tip modified by focused ion beam (FIB) and experimental results in non-contact mode of atomic force microscopy (AFM) using fabricated tip. We used an electric field which causes dielectrophoresis, to align and deposit CNTs on a conventional silicon tip. The morphology of the fabricated CNT tip was then modified into a desired shape using focused ion beam. We measured anodic aluminum oxide sample and trench structure to estimate the performance of FIB-modified tip and compared with those of conventional Si tip. We demonstrate that FIB modified tip in non contact mode had superior characteristics than conventional tip in the respects of wear, image resolution and sidewall measurement.

Development of a Shape Inspection System of the Light Guide Panel

  • Youn, Sang-Pil;Lee, Young-Chon;Ryu, Young-Kee
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2001.10a
    • /
    • pp.53.3-53
    • /
    • 2001
  • This paper deals with the development of a shape inspection system of the Light Guide Panel(LGP), and the study for the performance of the system. The conventional contact sensing methods have been used to inspect the shape. However the contact-sensing methods have some problems. The contact between a tip of the sensor and the surface of objects make a sensor tip abraded and generate a defect on the surface of objects. In this paper, we employed the Non-Contact Optical Sensor[1] to measure the shape inspection system of LGPs, The Sensor composed of Hologram laser[3] unit used for CD Optical Pickup[2] is low cost and has a good performance to measure a transparent objects. From the results of experiments for LGP shape inspection ...

  • PDF

Dendrite Tip Shapes of Pivalic Acid-Ethanol and Succinonitrile-Salol Systems (Pivalic Acid-Ethanol 및 Succinonitrile-Salol 계에서의 수지상정 선단의 형상)

  • Suk, Myung-Jin;Park, Young-Min;Oh, Sung-Tag;Chang, Si-Young
    • Korean Journal of Metals and Materials
    • /
    • v.49 no.7
    • /
    • pp.570-576
    • /
    • 2011
  • The shape of a dendrite tip has long been approximated by a paraboloid of revolution, but many attempts have been made as well to more accurately match the dendrite tip profile using other mathematical functions: power function, 4th order polynomial, and hyperbolic function. In the present work, dendrite tip shapes were matched by parabolic function. The differences between the dendrite tip shapes of pivalic acid(PVA)-ethanol(Eth) and succinonitrile(SCN)-salol systems, characterized by anisotropic and isotropic solid-liquid interfacial properties, respectively, were quantitatively treated using shape parameters. The PVA-Eth system showed a slightly higher Z/R value than the SCN-salol system, their Z/R values lying in the range 2-4. (Z is the distance from the tip beyond which the parabolic fit starts to deviate from the profile, and R the tip radius.) ${\lambda}_P$ is the distance from the tip beyond which side branching starts to appear, and is larger in the PVA-Eth system than the SCNsalol system. ${\lambda}_P$ is different for both sides of the 2-dimensional dendrite profile. The difference of ${\lambda}_P$ between both sides of the dendrite is larger for PVA-Eth system than for SCN-salol, implying that the dendrite of PVA-Eth is less symmetric than that of SCN-salol.

Wear Characteristics of Atomic force Microscope Tip (Atomic Force Microscope Tip 의 마멸특성에 관한 연구)

  • 정구현;김대은
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.20 no.5
    • /
    • pp.189-195
    • /
    • 2003
  • Atomic Force Microscope (AFM) has been widely used in micro/nano-scale studies and applications for. the last few decade. In this work, wear characteristics of silicon-based AFM tip was investigated. AFM tip shape was observed using a high resolution SEM and the wear coefficient was approximately calculated based on Archard's wear equation. It was shown that the wear coefficient of silicon and silicon nitride were in the range of ${10}^{-1}$~${10}^{-3}$ and ${10}^{-3}$~${10}^{-4}$, respectively. Also, the effect of relative humidity and sliding distance on adhesion-induced tip wear was discussed. It was found that the tip wear has more severe for harder test materials. Finally, the probable wear mechanism was analyzed from the adhesive and abrasive interaction point of view.

Wear Characteristics of Atomic Force Microscope Tip

  • Chung, Koo-Hyun;Kim, Dae-Eun
    • International Journal of Precision Engineering and Manufacturing
    • /
    • v.5 no.2
    • /
    • pp.39-45
    • /
    • 2004
  • Atomic Force Microscope (AFM) has been widely used in micro/nano-scale studies and applications for the last few decades. In this work, wear characteristics of silicon-based AFM tip was investigated. AFM tip shape was observed using a high resolution SEM and the wear coefficient was approximately calculated based on Archard's wear equation. It was shown that the wear coefficient of Si and ${Si}_3$$N_4$ tips were in the range of ${10}^{-1}$~${10}^{-3}$and ${10}^{-3}$~${10}^{-4}$, respectively. Also, the effect of relative humidity and sliding distance on adhesion-induced tip wear was investigated. It was found that the tip wear has more severe for harder counter surface materials. Finally, the probable wear mechanism was analyzed from the adhesive and abrasive interaction point of view.

A Study on Design of Nozzle Tip for Airless Spray Coating (에어리스 스프레이 도장용 노즐 팁 설계에 관한 연구)

  • Kim, Dong-Keon;Kim, Soon-Kyung
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • v.11 no.6
    • /
    • pp.183-188
    • /
    • 2012
  • This study was carried out to design the spray nozzle tip for airless spray coating. Airless spray coating is the process of coating an object with a liquid spray of paint or other fluid. The nozzle tip controls the fluid flow rate and creates back pressure in the system. The nozzle tip also defines the spray pattern by the size and shape of the orifice. The spray pattern of nozzle tip was investigated numerically using ANSYS CFX ver. 14.0. It was observed that performance result of designed nozzle tip was correspond well, compared with that of GARCO nozzle tip.