• Title/Summary/Keyword: tin colloid

Search Result 44, Processing Time 0.024 seconds

Camparison of the Efficiency for Tc-99m Tin-colloid and Tc-99m Phytate in Sentinel Node Detection in Breast Cancer Patients (유방암 환자의 전초림프절 검사에서 Tc-99m Tin-colloid와 Tc-99m Phytate의 효용성에 대한 비교)

  • Seok, Ju-Won;Kim, In-Ju
    • Nuclear Medicine and Molecular Imaging
    • /
    • v.42 no.6
    • /
    • pp.451-455
    • /
    • 2008
  • Purpose: Lymphoscintigraphy and sentinel node biopsy has become a standard method for detection of axillary lymph node metastasis in breast cancer patients, but the standard radiopharmaceutical was not prepared. About detection of axillary lymph node metastasis by lymphoscintigraphy and sentinel node biopsy in breast cancer patient, we compared the results of Tc-99m Tin-colloid and Tc-99m Phytate by subareolar injection. Materials and Methods: This study included 382 breast cancer patients who were performed operation during 2001-2008. Three hundred forty nine patients was injected 0.8ml of Tc-99m Tin-colloid (37-185 MBq) by subareolar injection. Thirty three patients was injected 0.8ml of Tc-99m Phytate (37-185 MBq). Lymphoscintigraphy was performed in supine position and sentinel node localization was performed by hand-held gamma probe in operation. Result: Among 349 patients by Tc-99m Tin-colloid, 312 cases (89.4%) localized the sentinel node by lymphoscintigraphy, 304 cases (87.1%) localized by gamma probe. Among 33 patients by Tc-99m Phytate, 32 cases (97.0%) localized by lymphoscintigraphy, 33 cases (100%) localized by gamma probe. Detection rate by lymphoscintigraphy and gamma probe was superior for Tc-99m Phytate compared to that with Tc-99m Tin-colloid, with a statistically significant difference. (p<0.05, p<0.05) Conclusion: Tc-99m Phytate is a better choice for localization of sentinel node than Tc-99m Tin-colloid in breast cancer patients.

Preclinical application of 188Re-Tin colloid for treatment of mouse tumor model with peritoneal effusion

  • Jin, Yong Nan;Lee, Yong Jin;Kim, Young Joo;Lee, Yun-Sang;Jeong, Jae Min
    • Journal of Radiopharmaceuticals and Molecular Probes
    • /
    • v.3 no.2
    • /
    • pp.80-84
    • /
    • 2017
  • Re-188 is an excellent and practical radioisotope produced by W-188/Re-188-generator for therapy. We prepared Re-188-tin colloid for therapy of various diseases and tried to treat peritoneal effusion in animal model. Sarcoma-180 cells were injected into ICR mice to induce peritoneal effusion and the mice were grown for 3 d. Re-188-tin colloids (0.25, 0.5, and 1 mCi/mL per 30 g body weight) were injected into the mice and the mice were grown for 90 d. Planar gamma scintigraphy showed even distribution of Re-188-tin colloid radioactivity. Bax expression was found to be dose dependent to Re-188-tin colloid. Normal saline treated group showed the shortest survival time. Among the treated groups, 0.5 mCi dose group showed the longest survival time. In conclusion, Re-188-tin colloid was prepared successfully and showed the feasibility to use as a peritoneal effusion treatment in mice.

Initial experience with intra-articular 188Re-tin colloid as a "radiation synovectomy" agent in various joints

  • Shinto, Ajit S;Indira, VU;Kamaleshwaran, KK;Banka, Vinay Kumar;Aswathy, KK;Thirumalaisamy, SG;Rajamani, V;Mallia, Madhav;Banerjee, Sharmila
    • Journal of Radiopharmaceuticals and Molecular Probes
    • /
    • v.1 no.2
    • /
    • pp.109-117
    • /
    • 2015
  • Radiation synovectomy has been proposed as a promising palliative therapy for recurrent joint effusions for the last two or three decades. Ionizing radiations emitted by intrarticularly administered radiolabelled colloids. The aim of this study was to assess the effectiveness of radiation synovectomy (RSV) using $^{188}Re$-tin colloid in the treatment of recurrent joint effusions and chronic synovitis of knee joints. Three phase bone scan was acquired for the concerned joint prior to radiosynovectomy. $^{188}Re$-tin colloid was prepared as per the reported protocol. 9 patients, diagnosed with rheumatoid arthritis and suffering from chronic resistant synovitis of the knee, ankle or elbow joints were administered the radiopharmaceuticals, checked for radiochemical purity >95% by intraarticular route. A whole body scan was acquired 2 h post-radiosynovectomy. In all the 9 treatments, no leakage to non-target organs was visible in the whole body scan. Static scans of the joint revealed complete retention of $^{188}Re$-tin colloid in the joints post administration of the agent. Clinically all patients exhibited a complete or partial response. RSV with $^{188}Re$-tin colloid was safe and effective in patients with chronic synovitis of rheumatoid origin.

DA-7911, $^{188}Rhenium-tin$ Colloid, as a New Therapeutic Agent of Rheumatoid Arthritis

  • Shin, Chang-Yell;Son, Miwon;Ko, Jun-Il;Jung, Mi-Young;Lee, In-Ki;Kim, Soon-Hoe;Kim, Won-Bae;Jeong, Jae-Min;Song, Yeong-Wook
    • Archives of Pharmacal Research
    • /
    • v.26 no.2
    • /
    • pp.168-172
    • /
    • 2003
  • Radiation synovectomy is one of the most useful methods for treating patients with refractory synovitis because of its convenience, long-term effects, repeatability and the avoidance of surgery. In this study, we investigated the toxicity, stability and biodistribution of a rhenium-188 ($^{188}$Re)-tin colloid to evaluate its suitability as a synovectomy agent. Twenty four hours after injecting the $^{188}$Re-tin colloids (74 KBq/0.1 mL) into the tail vein of ICR mice, most of the $^{188}$Retin colloidal particles was found in the lungs. In addition, there were no particle size changes at either room temperature or at $37^{\circ}C$ after injecting the $^{188}$Re-tin colloids in human plasma and synovial fluid. In vitro stability tests showed that the $^{188}$Re-tin colloid remained in a colloidal form without a critical size variation over a 2-day period. We investigated the leakage of $^{188}$Retin colloids from the intraarticular injection site with gamma counting in New Zealand white rabbits. The $^{188}$Re-tin colloids (55.5 MBq/0.15 mL) were injected at the cavum articular and the mean retention percentage of the $^{188}$Re-tin colloid was 98.7% for 1 day at the injection site, which suggests that there was neither change in the particle size nor leakage at the injection sites. In the biodistribution study with the SD rats, the liver showed the highest radioactivity (0.0427% ID/organ) except for the injected knees (99.49%). In the SD rats, mild toxicities including the skin or a synovium inflammation were observed as a result of a radioactivity of 15 mCi/kg at the intraarticular injection site. However, there was no systemic toxicity. In the Ovalbumin (OVA)-induced arthritic rabbits, the $^{188}$Re-tin colloid improved the macroscopic, the histological score and reduced the knee joint diameter when compared to the arthritic control. In conclusion, a $^{188}$Re-tin-colloid is considered as a strong candidate for radiation synovectomy with a superior efficacy and safety.

$^{99m}Tc-Tin$ Colloid Uptake Ratio of Femoral Head in Healthy Korean (정상 한국인 대퇴골두의 $^{99m}Tc-Tin$ Colloid 섭취율)

  • Zhi, Won-Hee;Sohn, Hyung-Sun;Kim, Choon-Yul;Bahk, Yong-Whee
    • The Korean Journal of Nuclear Medicine
    • /
    • v.23 no.2
    • /
    • pp.215-218
    • /
    • 1989
  • Tc-99m-tin colloid distribution in the hip is studied in 76 patients with no hepatic and hip disorder, because knowledge of normal uptake pattern in the hip is important in evaluation of femoral head vasculature after a fracture. The uptake in femoral head is decreased or disappeared with increasing age due to conversion of red marrow to white marrow.

  • PDF

Comparison of 99mTc-Tin colloid colloid and 99mTc-DISIDA Hepatoscintigraphy in Miniature Pigs (미니돼지에서 99mTc-Tin colloid와 99mTc-DISIDA를 사용한 간신티그라피의 비교 연구)

  • Shim, Kyung-Mi;Kim, Se-Eun;Lee, Won-Guk;Koong, Sung-Soo;Bae, Chun-Sik;Lee, Jae-Yeong;Choi, Seok-Hwa;Han, Ho-Jae;Kang, Seong-Soo;Park, Soo-Hyun
    • Journal of Life Science
    • /
    • v.16 no.6
    • /
    • pp.1060-1065
    • /
    • 2006
  • Non-invasive evaluation of liver function in animal models remains a challenge. Hepatoscintigraphy provides information about changes in liver size and shape, and enables to understand general liver function. Futhermore it is readily used to diagnosis complications of liver transplantation like hepatitis, rejections and biliary complications. In this study, we investigated the usefulness of evaluating the liver function in miniature pigs with $^{99m}Tc-Tin$ colloid and $^{99m}Tc-DISIDA$ which are the most commonly used radiopharmaceuticals in human medicine. In result, $^{99m}Tc-Tin$ colloid was uptaked in lung, liver, gastric wall and kidney in miniature pigs. And $^{99m}Tc-DISIDA$ showed continuous uptake images of heart, lung, liver, gallbladder and duodenum, and it was similar to human's. Therefore we could conclude $^{99m}Tc-Tin$ colloid would not be suitable for evaluating hepatic function because of it's nonspecific affinity, however $^{99m}Tc-DISIDA$ scintigraphy would be an effective method for detecting hepatobiliary function in miniature pigs.

Miniaturized Chromatographic Quality Control of $^{99m}Tc$ Radiopharmaceuticals (Miniaturized Chromatography에 의한 $^{99m}Tc$-표지 방사성의약품의 정도 관리)

  • Yeom, Mi-Kyoung;Jeong, Jae-Min;Jin, Kwang-Ho;Cho, Kyu-Jin;Chung, June-Key;Lee, Myung-Chul;Koh, Chang-Soon
    • The Korean Journal of Nuclear Medicine
    • /
    • v.24 no.1
    • /
    • pp.133-137
    • /
    • 1990
  • The general use of a number of $^{99m}Tc-labelled$ compounds makes the need for good routine quality control procedures, especially the labelling efficiency measurements. The purpose of these study were to measure the labelling efficiency of $^{99m}Tc-labelled$ MDP, DTPA, Tin colloid, and Antimony sulfide colloid using miniaturized paper and instant thin layer chromatography. The chromatographic systems include whatman 3 MM paper and acetone, Gelman ITLC-SG and 0.9% sodium chloride. The chromatographic strips are miniaturized $(1\times10\;cm)$, marked and numbered. Labelling efficiencies of $^{99m}Tc-labelled$ DTPA and Tin colloid were above 98.0%. $^{99m}Tc-labelled$ Antimony sulfide colloid was 90.0%. And labelling efficiency of $^{99m}Tc-labelled$ MDP was 89.0% Coefficient variance of $^{99m}Tc-labelled$ MDP, DTPA, Tin colloid, and Antimony sulfide colloid were 5.14%, 2.06%, 1.82% and 4.90%, respectively. We found that this miniaturized chromatographic quality control was simple and reliable.

  • PDF

Significance of $^{99m}Tc-tin$ Colloid Scan in Rejection of Transplanted Kidney (이식신(移植腎) 거부반응(拒否反應)에서 $^{99m}Tc-tin$ colloid 스캔의 의의)

  • Oh, Ha-Young;Kim, Seung-Taik;Park, Seon-Yang;Kim, Sung-Gwon;Lee, Myung-Chul;Cho, Bo-Youn;Lee, Jung-Sang;Koh, Chang-Soon
    • The Korean Journal of Nuclear Medicine
    • /
    • v.16 no.2
    • /
    • pp.49-58
    • /
    • 1982
  • Renal transplant uptake of $^{99m}Tc-tin$ colloid was evaluated in 26 patients. Seventy-seven examinations were performed comparing transplant with bone marrow activity, clinical and/or pathological diagnosis. There were 13 instances of acute rejection; 7 of these exhibited slight uptake of radiocolloid in the renal transplant, 1 had marked uptake, and 5 had no evidence of uptake. There were 7 instances of chronic rejection; 5 of which demonstrated marked transplant uptake of radiocolloid, 1 had slight uptake, and 1 had no evidence of uptake. There were 2 instances of acute tubular necrosis and 55 instances of normal transplant function, but none of these exhibited transplant uptake of radiocolloid. From the result, the uptake of $^{99m}Tc-tin$ colloid by renal transplant appears to signal rejection as long. as the vascular supply is not severely compromised. Acute rejection may be represented by slight radiocolloid uptake, and chronic rejection by marked uptake when compared to bone marrow activity.

  • PDF

Comparison of the Results for Sentinel Lymph Node Mapping in the Breast Cancer Patients using $^{99m}Tc$-Antimony Trisulfide Colloid, $^{99m}Tc$-Tin Colloid, and $^{99m}Tc$-Human Serum Albumin (유방암 환자에서 $^{99m}Tc$-Antimony Trisulfide Colloid, $^{99m}Tc$-Tin Colloid, $^{99m}Tc$-Human Serum Albumin을 이용한 감시림프절 매핑 성적의 비교)

  • Jang, Sung-June;Moon, Seung-Hwan;Kim, Seok-Ki;Kim, Bom-Sahn;Kim, Seok-Won;Chung, Ki-Wook;Kang, Keon-Wook;Lee, Eun-Sook
    • Nuclear Medicine and Molecular Imaging
    • /
    • v.41 no.6
    • /
    • pp.546-552
    • /
    • 2007
  • Purpose: In the breast cancer patient, lymphatic mapping and sentinel lymph node biopsy are the most important procedure for axillary lymph node staging. We aimed to compare the three radiocolloids [$^{99m}Tc$-antimony trisulfide colloid (ASC), $^{99m}Tc$-tin colloid (TC), and $^{99m}Tc$-human serum albumin (HSA)] for sentinel lymph node mapping. Subjects and Methods: Totally, 397 patients with clinically N0 stage were enrolled. $^{99m}Tc$-ASC was injected in 202 out of 397 patients, $^{99m}Tc$-TC was injected in 120 patients, and $^{99m}Tc$-HSA was injected in the remaining 75 patients. The sentinel lymph nodes were localized by lymphoscintigraphy and selected using intraoperative gamma probe. All sentinel lymph nodes were investigated by intraoperative pathologic consultation. The axillary lymph nodes which were harvested by the lymph node dissection were also investigated. Results: The patients of each group showed similar clinical characteristics. There were no significant differences (p>0.05) in the identification rate of sentinel lymph nodes (IR), false negative rate (FNR), and negative predictive value (NPV). The axillary lymphadenectomy revealed axillary lymph node metastases in those three groups (ASC-33.2%, TC-31.7%, HSA-22.7%). The IR, FNR, and NPV were not significantly different among those groups. Conclusion: Those three $^{99m}Tc$-labeled radiocolloids showed equivalent results in sentinel lymph node mapping of breast cancer.