• 제목/요약/키워드: time-step analysis

검색결과 1,643건 처리시간 0.03초

Development of higher performance algorithm for dynamic PIV

  • NISHIO Shigeru
    • 한국가시화정보학회:학술대회논문집
    • /
    • 한국가시화정보학회 2004년도 Proceedings of 2004 Korea-Japan Joint Seminar on Particle Image Velocimetry
    • /
    • pp.25-32
    • /
    • 2004
  • The new algorithm for higher performance of dynamic PIV has been proposed. Present study considered mathematical basis of PIV analysis for multiple-time-step images and it enables us to analyze the high time-resolution PIV, which is obtained by dynamic PIV system. Conventional single pair image PIV analysis gives us the velocity field data in each time step but it sometimes contains unnecessary information of target flow. Present technique utilize multi-time step correlation information, and it is analyzed.

  • PDF

Evaluation of Ergonomic Performance of Medical Smart Insoles

  • Yi, Jae-Hoon;Lee, Jin-Wook;Seo, Dong-Kwon
    • Physical Therapy Rehabilitation Science
    • /
    • 제11권2호
    • /
    • pp.215-223
    • /
    • 2022
  • Objective: This study was to resolve the limitations of the experimental environment and to solve the shortcomings of the method of measuring human gait characteristics using optical measuring instruments. Design: A cross-sectional study. Methods: Fifteen healthy adults without a history of orthopedic surgery on the lower extremities for the past 6 months were participated. They were analyzed gait variables using the smart guide and the 3D image analysis at the same time, and their results were compared. Visual-3D was used to calculate the analysis variables. Results: The reliability and validity of the data according to the two measuring instruments were found to be very high; gait speed(0.85), cycle time(0.99), stride time of both feet(0.98, 0.97) stride legnth of both feet(0.86, 0.88) stride per minute of both feet(0.99, 0.96), foot speed of both feet(0.90, 0.91), step time of both feet(0.77, 0.71), step per minute(0.72, 0.74), stance time of both feet(0.96, 0.97), swing time of both feet(0.93, 0.79), double step time(0.81), initial double step time(0.84) and terminal step time(0.76). Conclusions: In the case of the smart insole, which measures human gait variables using the pressure sensor and inertial sensor inserted in the insole, the reliability and validity of the measured data were found to be very high. It can be used as a device to replace 3D image analysis when measuring pathological gait.

와전류를 포함하는 시간차분 해석의 계산오차에 대한 연구 (Study on the Error Estimation of Time-step Analysis for a Problem with Eddy Current)

  • 최명현;김병택
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2008년도 제39회 하계학술대회
    • /
    • pp.854-855
    • /
    • 2008
  • This paper deals with the computation error produced in the time step analysis for a electric machine with eddy current. To investigate the error in quantity, the analytic equations representing the steady state results of time-step analysis are deduced. Using the equations, the characteristics of errors are calculated for a general electric circuit, with variation of the circuit parameters and step size.

  • PDF

가변시간간격을 갖는 Newmark 시간적분법의 사다리꼴법칙에 대한 안정성과 정확도 (Stability and accuracy for the trapezoidal rule of the Newmark time integration method with variable time step sizes)

  • 노용수;정진태;배대성
    • 대한기계학회논문집A
    • /
    • 제21권10호
    • /
    • pp.1712-1717
    • /
    • 1997
  • Stability and accuracy for the trapezoidal rule of the Newmark time integration method are analyzed when variable time step sizes are adopted. A new analytic approach to stability and accuracy analysis is also proposed for time integration methods with variable time step sizes. The trapezoidal rule with variable time step sizes has the "actual" unconditional stability which is the same as that of the method with constant time step sizes. However, the method with variable time step sizes is first-order accurate while the method with constant time step sizes is second-order accurate. accurate.

Analysis of delay compensation in real-time dynamic hybrid testing with large integration time-step

  • Zhu, Fei;Wang, Jin-Ting;Jin, Feng;Gui, Yao;Zhou, Meng-Xia
    • Smart Structures and Systems
    • /
    • 제14권6호
    • /
    • pp.1269-1289
    • /
    • 2014
  • With the sub-stepping technique, the numerical analysis in real-time dynamic hybrid testing is split into the response analysis and signal generation tasks. Two target computers that operate in real-time may be assigned to implement these two tasks, respectively, for fully extending the simulation scale of the numerical substructure. In this case, the integration time-step of solving the dynamic response of the numerical substructure can be dozens of times bigger than the sampling time-step of the controller. The time delay between the real and desired feedback forces becomes more striking, which challenges the well-developed delay compensation methods in real-time dynamic hybrid testing. This paper focuses on displacement prediction and force correction for delay compensation in the real-time dynamic hybrid testing with a large integration time-step. A new displacement prediction scheme is proposed based on recently-developed explicit integration algorithms and compared with several commonly-used prediction procedures. The evaluation of its prediction accuracy is carried out theoretically, numerically and experimentally. Results indicate that the accuracy and effectiveness of the proposed prediction method are of significance.

승강장 안전발판 시스템의 내구성 평가 (Durability Evaluation of Platform Safety Step System)

  • 박민흥;곽희만;김민호
    • 한국신뢰성학회지:신뢰성응용연구
    • /
    • 제16권2호
    • /
    • pp.125-133
    • /
    • 2016
  • Purpose: The purpose of this study is to evaluate durability of platform safety step system in railway. Method: We performed finite element analysis & durability analysis of platform safety step system with VPD (Virtual Product Development) techniques and examined the durability standard & qualification life through the rig test during no failure test time in reliability qualification test. We continued to test 1 million cycles in KRS (Korea Railway Standard) for system's robust design performance. Result: FEM analysis results are 14.9MPa & 14.7MPa of pin-joint, pivot and durability analysis result is above 1 million cycles. we calculated theoretically no failure test time 855,000 cycles and through the 1 million cycles durability rig test in KRS standard we confirmed product quality. Conclusion: This platform safety step system was designed very safe in terms of a mechanical strength & durability.

SED2D모형을 이용한 저수지 퇴사거동 모의-모의시간간격의 민감도를 중심으로 (Simulation of Sediment Deposition Behavior in a Reservoir using a SED2D model: Focusing on Sensitivity of Simulation Time Step)

  • 김대근
    • 상하수도학회지
    • /
    • 제26권1호
    • /
    • pp.87-95
    • /
    • 2012
  • In this study, the following conclusions were obtained from an investigation of the effect of the simulation time step on the simulation results of the two-dimensional, vertically averaged sediment transport model SED2D and an analysis of the deposited sediment distribution in suspended sediments of reservoirs according to grain size. The simulation time step has a significant effect on the deposited sediment distribution in a reservoir. In particular, if the simulation time step is set to be excessively large, physically invalid results are obtained. Additionally, in order to determine an appropriate simulation time step for SED2D, the selection of a simulation time step that will allow the analysis of the suspended sediment concentration profile at the main points of the simulation domain is necessary. The deposited sediment distribution in a reservoir according to grain size, including suspended sediments of clay, silt, and sand, was successfully simulated. Such information will prove valuable in application to the establishment of efficient management and reduction measures of reservoir sediment deposits.

Determination of Proper Time Step for Molecular Dynamics Simulation

  • 조종철;김병철
    • Bulletin of the Korean Chemical Society
    • /
    • 제21권4호
    • /
    • pp.419-424
    • /
    • 2000
  • In this study we have investigated the determination of proper time step in molecular dynamics simulation.Since the molecular dynamics is mathematically related to nonlinear dynamics, the analysis of eigenvalues isused to explain the relationship between the time step and dynamics. The tracings of H2 and CO2 molecular dynamics simulation agrees very well with the analytical solutions. For H2, the time step less than 1.823 fs pro-vides stable dynamics. ForCO2, 3.808 fs might be the maximum time step for proper molecular dynamics. Al-though this results were derived for most simple cases of hydrogen and carbon dioxide, we could quantitatively explain why improperly large time step destroyed the molecular dynamics. From this study we could set the guide line of the proper time step for stable dynamics simulation in molecular modeling software.

반용융 단조에서 응고 현상을 고려한 가압유지 단계의 유한요소해석 (Finite Element Analysis of Compression Holding Step Considering Solidification for Semi-Solid Forging)

  • 최재찬;박형진;조해용
    • 한국정밀공학회:학술대회논문집
    • /
    • 한국정밀공학회 1997년도 춘계학술대회 논문집
    • /
    • pp.597-601
    • /
    • 1997
  • The technology of Semi-Solid Forging(SSF) has been actively developed to fabricate near-net shape products using light and hardly formable materials. Generally, the SSF process is composed of slug heating,forming,compression holding and ejecting step. After forming step in SSF, the slug is comperssed during a certain holding time in order to be completely filled in the die cavity and be accelerated in solidification rate. This paper presents the analysis of temperature,solid fraction and shrinkage at compression holding step for a cylindrical slug,then predicts the solidification time to obtain the final shaped part. Enthalpy-based finite element analysis is performed to solve the heat transfer problem considering phase change in solidification.

  • PDF

반용융 단조에서 응고 현상을 고려한 가압유지 단계의 유한요소해석 (Finite Element Analysis of Compression Holding step Considering Solidification for Semi-Solid Forging)

  • Park, J.C.;Park, H.J.;Cho, H.Y.
    • 한국정밀공학회지
    • /
    • 제14권10호
    • /
    • pp.102-108
    • /
    • 1997
  • The technology of Semi-Solid Forging (SSF) has been actively developed to fabricate near-net- shape products using light and hardly formable materials. Generally, the SSF process is composed of slug heating, forming, compression holding and ejecting step. After forming step in SSF, the slug is compressed during a certain holding time in order to be completely filled in the die cavity and be accelerated in solidification rate. This paper presents the analysis of temperature, solid fraction and shrinkage at compression holding step for a cylindrical slug, then predicts the solidification time to obtain the final shaped part. Enthalpy-based finite element analysis is performed to solve the heat transfer problem considering phase change in solidification.

  • PDF