Estimating the Cost of Air Pollution on Morbidity: Focusing on Hospital Visit for Acute Respiratory Diseases (대기오염으로 인한 건강효과의 경제적 비용 -급성 호흡기 질환 외래환자를 중심으로-)

  • Shin, Young Chul
    • Environmental and Resource Economics Review
    • /
    • v.11 no.4
    • /
    • pp.659-687
    • /
    • 2002
  • This study used a discrete choice model to investigate an association between air pollution and hospital visits for acute respiratory symptoms with the national health interview survey conducted in 1998 in South Korea. The results showed that $NO_2$ and TSP were significantly related to hospital visits in a single-pollutant model, but when they were simultaneously considered, only $NO_2$ remained significant. It was estimated as $NO_2$ level increased by 10%(0.0027ppm) from 0.027ppm (the mean $NO_2$ level), hospital visits increase by 0.176%. This study also measured respondent's out-of-pocket expense and the time cost for commuting and waiting for the visit. We found that on the average, out-of-pocket expense is 5,600 won per hospital visit, but the total cost per hospital visit is measured at 33,440 won with time cost of commuting and waiting at 27,840 won. Time cost was over 63.6~83.3% of the total cost per hospital visit.

  • PDF

Time Domain Acoustic Holography by Step-by-step Measurement (단계적 측정법에 의한 시간 영역 음향 홀로그래피)

  • 윤호성;남경욱;김양한
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2003.05a
    • /
    • pp.635-639
    • /
    • 2003
  • When we carry out acoustic holography, step-by-step measurement provides us larger aperture size with same number of microphones. But when we carry out step-by-step measurement, it is blown that sound signal must be stationary. However, when transfer function between input and output signal is time-invariant, we can apply step-by-step measurement to acoustic holography even if sound signal is transient We have to do only some Processing on signals from step-by-step measurements to make the signal data of each step compatiable with other steps. This paper accounts for that processing method.

  • PDF

Monitoring for the Fermentation Conditions of Sweet Persimmon Vinegar using Response Surface Methodology (반응표면분석에 의한 단감식초 제조조건의 모니터링)

  • 정용진;서권일;이기동;윤광섭;강미정;김광수
    • Journal of the East Asian Society of Dietary Life
    • /
    • v.8 no.1
    • /
    • pp.57-65
    • /
    • 1998
  • To utilize deteriorated sweet persimmon effectively, response surface methodology(RSM) was used to determine the optimal vinegar fermentation conditions and monitored by a divided two stage fermentation. The optimum conditions for maximum alcohol content were obtained when the first stage (alcohol fermentation) was carried out with an initial sugar concentration of 18.5$^{\circ}$Brix, agitation rate of 140.8 rpm, fermentation time of 127.6 hr. When sugar concentration was 14$^{\circ}$Brix maximum alcohol content(7.1%) was predicted at fermentation conditions of 160 rpm in agitation rate, 140hr in fermentation time. The optimum conditions for maximum acidity were obtaiend when second stage(vinegar fermentation)was carried out 249.5 rpm in agitation rate, 148.8 hr in fermentation time. Predicted values at the optimum conditions were similar to experimental values.

  • PDF

Removal Method for a Deposit at Sewerage with Polymer Additives (폴리머를 이용한 하수관로에서의 퇴적물 제거 기법)

  • Jeon, Chan-Yeal;Oh, Yool-Kwon;Hwang, Se-Joon
    • Journal of the Korean Society of Safety
    • /
    • v.17 no.4
    • /
    • pp.153-159
    • /
    • 2002
  • This experimental study is aimed to increasing the velocity in the sewerage and also development of easy removal method for a corrosion and sand in the flow pipe. And the result by the increasing the out flow per unit time, diameter of sewerage pipe is becoming small size, cut down the construction fee and the same time reducing the tubulent flow pattern in the flow pipe. As a result of detected experimental velocity signal from the probe in the test wall surface, reducing the pump power and increasing the out flow unit time. Apparent water velocity decreases as the value of void ratio increases depends on the varies center of pipe.

Study of Changes of Characteristics of SCR in accordance with a rise in temperature (온도상승에 따른 SCR 특성 변화에 관한연구)

  • Lee Young-Soo;Lee Kan-Woon;Park Moon-Dong;Cha Jae-Man
    • Proceedings of the KIEE Conference
    • /
    • summer
    • /
    • pp.1199-1201
    • /
    • 2004
  • When The temperature of the joining of SCR rises major changes of characteristics are increase of leakage current, decrease of break-down voltage, and increase of turn off time. Because these changes promote the inferiority of SCR it(SCR) will get out of control and its life time will be shortened and finally it will be destroyed. In this paper, we will measure the changes of the characteristics in accordance with a rise in temperature. On the basis of the result we will find out the appropriate time to change SCR and we will use the result for the maintenance of SCR and increase of reliability of SCR.

  • PDF

Temperature Distribution of Tracking Degradation Using IRR-Camera (적외선방사카메라를 이용한 트래킹열화 온도분포)

  • Jeong, Seung-Chun;Lim, Jang-Seob;Chen, Jong-Cheol;Jung, Woo-Seong;Lee, Jin
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2000.05a
    • /
    • pp.59-63
    • /
    • 2000
  • The conventional tracking testing as IEC-60587 is widely used in surface aging measurement of outside insulator because those testing can carry out very short time in Lab testing. Also IEC-60587 testing is able to offer the standard judgement of relative degradation level of outside HV machine. Therefore it is very useful method compare to previous conventional tracking testing method and effective Lab testing method. But surface discharges(SD) have very complex characteristics of discharge pattern so it is required estimation research to development of precise analysis method. In recent, the study of IIR-camera is carrying out discover of temperature of power equipment through condition diagnosis and system development of degradation diagnosis. In this study, SD occurred from IEC-60587 is measured with partial temperature distribution in real time, the degradation grade of SD is analyzed through produced patterns in IEC-60587 according to applied time.

  • PDF

Control of Magnetic Bearing using ATmega128(Focused on experiments) (ATmega128 소자를 이용한 자기베어링 제어(실험을 중심으로))

  • Yang, Joo-Ho;Choi, Gyo-Ho;Choung, Kwang-Gyo
    • Journal of Power System Engineering
    • /
    • v.17 no.4
    • /
    • pp.139-146
    • /
    • 2013
  • Because the magnetic bearing supports levitating body without contact, wear, noise and vibration, it is very useful to high revolution machinery. In this paper we selected ATmega 128, a less expensive and widely used micro controller, for control the magnetic bearing system. And we selected the sampling time and the control gain of PID controller through trial-and-error. The control program of the one board controller utilized lookup table to reduce calculation time, and bit shifting for the integer calculation in instead of floating point calculation. As the results, the controller carried out relatively high speed PID control on sampling time 0.25 ms. At last the rotation test for the magnetic bearing system was carried out by 3 phase induction motor and air turbine.

Development of Nexus for BIM and Documents based on Maintenance Process (유지보수공사 프로세스기반 BIM-문서 넥서스 구축)

  • Han, Ji-Ho;Park, Sang-Hun;Yoon, Sun-Jae;Koo, Kyo-Jin
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2021.05a
    • /
    • pp.168-169
    • /
    • 2021
  • Maintenance is carried out over a long period of time, and various documents are utilized in the maintenance work. In maintenance work which is progressed simultaneously in a short period of time, it is important to provide relevant information to the parties in a timely manner. As the types of work increase, manager needs more time and effort to select and utilize the documents. It is necessary to have an information system that supports the person in charge by grasping work procedures for each construction and providing the necessary documents and information for that step. This paper proposes an process based nexus model that can provide necessary documents to the parties to the work steps by linking the maintenance work process and BIM. Through the nexus model presented, manager can efficiently acquire the necessary documents and utilize them for the construction works currently being carried out.

  • PDF

A Unit Touch Gesture Model of Performance Time Prediction for Mobile Devices

  • Kim, Damee;Myung, Rohae
    • Journal of the Ergonomics Society of Korea
    • /
    • v.35 no.4
    • /
    • pp.277-291
    • /
    • 2016
  • Objective: The aim of this study is to propose a unit touch gesture model, which would be useful to predict the performance time on mobile devices. Background: When estimating usability based on Model-based Evaluation (MBE) in interfaces, the GOMS model measured 'operators' to predict the execution time in the desktop environment. Therefore, this study used the concept of operator in GOMS for touch gestures. Since the touch gestures are comprised of possible unit touch gestures, these unit touch gestures can predict to performance time with unit touch gestures on mobile devices. Method: In order to extract unit touch gestures, manual movements of subjects were recorded in the 120 fps with pixel coordinates. Touch gestures are classified with 'out of range', 'registration', 'continuation' and 'termination' of gesture. Results: As a results, six unit touch gestures were extracted, which are hold down (H), Release (R), Slip (S), Curved-stroke (Cs), Path-stroke (Ps) and Out of range (Or). The movement time predicted by the unit touch gesture model is not significantly different from the participants' execution time. The measured six unit touch gestures can predict movement time of undefined touch gestures like user-defined gestures. Conclusion: In conclusion, touch gestures could be subdivided into six unit touch gestures. Six unit touch gestures can explain almost all the current touch gestures including user-defined gestures. So, this model provided in this study has a high predictive power. The model presented in the study could be utilized to predict the performance time of touch gestures. Application: The unit touch gestures could be simply added up to predict the performance time without measuring the performance time of a new gesture.

Analysis for Electrical Fire Possibility Using Fuzzy Logic with Input Variables of Overcurrent and Saturation Time in the Indoor Wiring (전기배선에서 과전류와 포화시간을 입력변수로 갖는 퍼지기반 전기화재가능성 분석)

  • Kim, Eun-Jin;Kim, Doo-Hyun;Kim, Sung-Chul
    • Journal of the Korean Society of Safety
    • /
    • v.30 no.6
    • /
    • pp.34-39
    • /
    • 2015
  • The study is aimed to develop fuzzy logic system that has overcurrent and saturation time as input variable and possibility of electrical fire as output variable by making bad conductor area with physical damage to indoor wiring. Most previous studies focused on thermal characteristics depending on the current size and no study considered the current size and saturation time at the same time. Therefore, the paper made into account current value and saturation time together. To this end, it created bad conductor area half the size of IV conductor (1.6 mm) on purpose and transmit electrical current from 10A to 60A by unit of 2A to find out the thermal characteristics and saturation time for current. Based on the data that came out, the study applied fuzzy logic and established the current and saturation time as input variable and chance of fire as output variable. As a result, the center of area of the system that depended only on the existing current value was 75 while the system that applied both current and saturation time presented the chance of fire at 92. It is found that the chance of bad conductor area and deteriorated insulation of electrical wire had current and saturation time as important variables. The data can be used as basic data like deteriorated wire insulation or operation features of circuit breaker in investigating the cause of electrical fire.