• Title/Summary/Keyword: time to $V_{max}$

Search Result 128, Processing Time 0.025 seconds

Nitrate uptake of the red tide dinoflagellate Prorocentrum micans measured using a nutrient repletion method: effect of light intensity

  • Lee, Kyung Ha;Jeong, Hae Jin;Kim, Hye Jeong;Lim, An Suk
    • ALGAE
    • /
    • v.32 no.2
    • /
    • pp.139-153
    • /
    • 2017
  • The ability of a red tide species to take up nutrients is a critical factor affecting its red tide dynamics and species competition. Nutrient uptake by red tide species has been conventionally measured by incubating nutrient-depleted cells for a short period at 1 or 2 light intensities. This method may be applicable to certain conditions under which cells remain in oligotrophic water for a long time and high nutrients are suddenly introduced. Thus, a new method should be developed that can be applicable to the conditions under which cells are maintained in eutrophicated waters in healthy conditions and experience light and dark cycles and different light intensities during vertical migration. In this study, a new repletion method reflecting these conditions was developed. The nitrate uptake rates of the red tide dinoflagellate Prorocentrum micans originally maintained in nitrate repletion and depletion conditions as a function of nitrate concentration were measured. With increasing light intensity from 10 to $100{\mu}E\;m^{-2}s^{-1}$, the maximum nitrate uptake rate ($V_{max}$) of P. micans increased from 3.6 to $10.8 pM\;cell^{-1}d^{-1}$ and the half saturation constant ($K_{s-NO3}$) increased from 4.1 to $6.9{\mu}M$. At $20{\mu}E\;m^{-2}s^{-1}$, the $V_{max}$ and $K_{s-NO3}$ of P. micans originally maintained in a nitrate repletion condition were similar to those maintained in a nitrate depletion condition. Thus, differences in cells under nutrient repletion and depletion conditions may not affect $K_{s-NO3}$ and $V_{max}$. Moreover, different light intensities may cause differences in the nitrate uptake of migratory phototrophic dinoflagellates.

Square-Wave Voltammetric Study of Uranium(Ⅵ)-Cupferron Complex (Uranium(Ⅵ)-Cupferron 착물의 네모파 전압전류법적 연구)

  • Son, Se Cheol;Seo, Mu Yeol;Eom, Tae Yun;Choe, In Gyu
    • Journal of the Korean Chemical Society
    • /
    • v.38 no.3
    • /
    • pp.234-240
    • /
    • 1994
  • Square-wave voltammetric behavior for uranium(VI)-cupferron complex was studied in 0.1 M acetate buffer solution(pH5.0). The optimum condition for square-wave voltammetric analysis of uranium was also investigated. The reduction of uranium(VI)-cupferron complex was found to be irreversible and only uranium(VI)-cupferron complex was adsorbed on the electrode surface during the deposition time. Detection limit of uranium(VI) was 7.9nM(2 ppb) where the deposition time was 30sec at -0.1 V vs. Ag/AgCl. The amount of uranium(VI)-cupferron complex adsorbed on the electrode surface was ${\Gamma}_{max} = (4.9{\pm}0.3){\times}10^{-10} mol{\cdot}cm^{-2}$.

  • PDF

Bioequivalence and Pharmacokinetics of 70 mg Alendronate Sodium Tablets by Measuring Alendronate in Plasma

  • Yun Min-Hyuk;Woo Jong-Su;Kwon Kwang-Il
    • Archives of Pharmacal Research
    • /
    • v.29 no.4
    • /
    • pp.328-332
    • /
    • 2006
  • The bioequivalence and pharmacokinetics of alendronate sodium tablets were examined by determining the plasma concentration of alendronate. Two groups, consisting of 24 healthy volunteers, each received a 70 mg reference alendronate sodium tablet and a test tablet in a $2{\times}2$ crossover study. There was a 6-day washout period between doses. The plasma alendronate concentration was monitored for 7 h after the dose, using HPLC-Fluorescence Detector (FD). The area under the plasma concentration-time curve from time 0 to the last sampling time at 7 h $(AUC_{0-7h})$ was calculated using the linear-log trapezoidal rule. The maximum plasma drug concentration $(C_{max})$ and the time to reach $C_{max}(T_{max})$ were derived from the plasma concentration-time data. Analysis of variance was performed using logarithmically transformed $AUC_{0-7h}\;and\;C_{max}$, and untransformed $T_{max}$. For the test medication versus the reference medication, the $AUC_{0-7h}\;were\;87.63{\pm}29.27\;vs.\;102.44{\pm}69.96ng\;h\;mL^{-1}$ and the $C_{max}$ values were $34.29{\pm}13.77\;vs.\;38.47{\pm}24.39ng\;mL^{-1}$ respectively. The $90\%$ confidence intervals of the mean differences of the logarithmic transformed $AUC_{0-7h}$ and $C_{max}$ values were log 0.8234-log 1.1597 and log 0.8222-log 1.1409, respectively, satisfying the bioequivalence criteria guidelines of both the US Food and Drug Administration and the Korea Food and Drug Administration. The other pharmacokinetic parameters for the test drug versus reference drug, respectively, were: $t_{1/2},\;1.87{\pm}0.62\;vs.\;1.77{\pm}0.54\;h;\;V/F,\;2061.30{\pm}986.49\;vs.\;2576.45{\pm}1826.05\;L;\;CL/F,\;835.32{\pm}357.35\;vs.\;889.48{\pm}485.87\;L\;h^{-1}; K_{el},\;0.42{\pm}0.14\;vs.\;0.40{\pm}0.18\;h^{-1};\;Ka,\;4.46{\pm}3.63\;vs.\;3.80{\pm}3.64\;h^{-1};\;and\;T_{lag},\;0.19{\pm}0.09\;vs.\;0.18{\pm}0.06\;h$. These results indicated that two alendronate formulations(70-mg alendronate sodium) were biologically equivalent and can be prescribed interchangeably.

Effects of Percutaneous Balloon Mitral Valvuloplasty on Static Lung Function and Exercise Performance (승모판협착증 환자에서 경피적 풍선확장판막성형술의 폐기능 및 운동부하 검사에 대한 효과)

  • Kim, Yong-Tae;Kim, Woo-Sung;Lim, Chae-Man;Chin, Jae-Yong;Koh, Youn-Suck;Kim, Jae-Joong;Park, Seong-Wook;Park, Seung-Jung;Lee, Jong-Koo;Kim, Won-Dong
    • Tuberculosis and Respiratory Diseases
    • /
    • v.41 no.1
    • /
    • pp.1-10
    • /
    • 1994
  • Background: Patients with mitral stenosis(MS) have been demonstrated to have a variable degree of pulmonary dysfunction and exercise impairment. The hemodynamic changes of MS can be reversed after percutaneous mitral balloon valvuloplasty(PMV), but the extent and time course of the imporvement in pulmonary function and exercise capacity are not defined. Methods: In order to investigate the early(3 weeks or less)and late(3 months or more) effects of PMV on pulmonary function and determine if the pulmonary dysfunction is reversible even in patients with moderate to severe pulmonary hypertension, we performed the spirometry, measurements of diffusing capacity and lung volumes, and incremental exercise tests in patients with MS before and after PMV. Results: In 46 patients with MS(age: $40{\pm}12$years, male to female ratio: 1:2, mitral valve area: $0.8{\pm}0.2cm^2$) there was a significant increase in FVC(P<0.0025), $FEV_1$(P<0.001), $FEF_{25-75%}$(P<0.001, $FEF_{50%}$(P<0.001), PEF(P<0.0005), MVV(P<0.005), $\dot{V}O_2$max (P<0.0001), and AT(P<0.0001) after average 10 days of PMV. Also there was a significant decrease in DLco(P<0.0001) and DL/VA(P<0.0001). At later($5{\pm}2$months) follow-up in 11 patients, there was no further improvement in any parameters of pulmonary function and exercise test. Twenty nine patients with sinus rhythm were divided into 16 patients with pulmonary arterial pressure(PAP) more than 35mmHg and/or tricuspid regurgitation grade n or more(group A) and 13 patients with PAP less than 35mmHg(group B). Group A Patients had significantly lower FVC(P<0.001), $FEV_1$(P<0.001), DLco(P<0.05), $\dot{V}O_2$ max(P<0.025) and mitral valve area(P<0.025) than group B patients. Group A patients after PMV, showed significant increase in FVC(P<0.001), maximum $O_2$ pulse(P<0.00001) and $\dot{V}O_2$ max(P<0.00025). Both group showed an increase in AT(P<0.0001, P<0.005), but group A showed greater decrease in $\dot{V}E/\dot{V}O_2$ and $\dot{V}E/\dot{V}CO_2$ both at AT(P<0.001, P<0.001) and $\dot{V}O_2$ max(P<0.0001, P<0.0001) after PMV compared with group B. Conclusion: These data suggest that patients with MS can show increased pulmonary function and exercise performance within 1 month after PMV. Patients with moderate to severe pulmonary hypertension had a significant increase in exercise performance compared with those with mild to no pulmonary hypertension and it is thought to be related to a significat decrease of ventilation for a given oxygen consumption at maximum exercise.

  • PDF

Studies on the Bioavailability of Berberine Preparations (베르베린 제제의 생체 이용율에 관한 연구)

  • Yang, Jae-Heon;Kim, Young-Il
    • Journal of Pharmaceutical Investigation
    • /
    • v.22 no.1
    • /
    • pp.55-62
    • /
    • 1992
  • In order to measure the bioavailability of Coptidis Rhizoma preparations, berberine was extracted by the mixture (1:1 v/v) of methanol and water from Coptidis Rhizoma and formulated into pills with some excipients. Disintegration time, dissolution rate, intestinal absorption rate, antibacterial effect, and serum concentration were measured. All pills were disintegrated about 60 minutes in gastric and intestinal juices and disintegration time did not change upon storage at $40^{\circ}C$ for 30 days. The pills manufactured using the extract which was extracted with the solvent containing dilute sulfuric acid showed faster dissolution and absorption from the small intestine than the other samples. It also showed not only the largest area under the serum concentration time curve and relative bioavailability, but also more potent antibacterial effect against gram-positive and gram-negative bacterias than the other samples. The correlation of the dissolution rate with absorption rate constant or $t_{max}$ showed a significant linear relationship.

  • PDF

A Bottleneck Search Algorithm for Digraph Using Maximum Adjacency Merging Method (최대 인접 병합 방법을 적용한 방향 그래프의 병목지점 탐색 알고리즘)

  • Lee, Sang-Un
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.12 no.5
    • /
    • pp.129-139
    • /
    • 2012
  • Given digraph network $D=(N,A),n{\in}N,a=c(u,v){\in}A$ with source s and sink t, the maximum flow from s to t is determined by cut (S, T) that splits N to $s{\in}S$ and $t{\in}T$ disjoint sets with minimum cut value. The Ford-Fulkerson (F-F) algorithm with time complexity $O(NA^2)$ has been well known to this problem. The F-F algorithm finds all possible augmenting paths from s to t with residual capacity arcs and determines bottleneck arc that has a minimum residual capacity among the paths. After completion of algorithm, you should be determine the minimum cut by combination of bottleneck arcs. This paper suggests maximum adjacency merging and compute cut value method is called by MA-merging algorithm. We start the initial value to S={s}, T={t}, Then we select the maximum capacity $_{max}c(u,v)$ in the graph and merge to adjacent set S or T. Finally, we compute cut value of S or T. This algorithm runs n-1 times. We experiment Ford-Fulkerson and MA-merging algorithm for various 8 digraph. As a results, MA-merging algorithm can be finds minimum cut during the n-1 running times with time complexity O(N).

Column filled with Fe-GAC and GAC to remove both As(V) and Fe(III) (비소와 철 동시제거를 위한 Fe-GAC와 GAC로 충진된 컬럼)

  • Lee, Yong-Soo;Do, Si-Hyun;Hong, Seong-Ho
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.30 no.1
    • /
    • pp.87-97
    • /
    • 2016
  • First of all, Fe or/and Mn immobilized granular activated carbons (Fe-GAC, Mn-GAC, (Fe, Mn)-GAC) were synthesized and tested to remove arsenate (As(V)). The results in batch test indicated that Fe-GAC removed As(V) effectively, even though the surface area of Fe-GAC was reduced largely. Moreover, adsorption isotherm test indicated that the experimental data fit well with Langmuir model and the maximum adsorption capacity ($q_{max}$) of Fe-GAC for As(V) was $3.49mg\;g^{-1}$, which was higher than GAC ($2.24mg\;g^{-1}$). In column test, the simulated water, which consisted of As(V), Fe(III), Mn(II) and Ca(II) in tap water, was used. Fe-GAC column with 1 hr of pre-washing time treated As(V) effectively while GAC column removed Fe(III) better than Fe-GAC column. Moreover, the increasing pre-washing time from 1 to 9 hour in Fe-GAC column enhanced Fe(III) removal with little negative impact of As(V) removal. Mostly, the column filled with Fe-GAC and GAC (i.e. the mass ratio of Fe-GAC:GAC = 2:8) showed the higher treatability of both As(V) and Fe(III), even it operated with 1 hr pre-washing time.

Pulsed-Power System for Leachate Treatment Applications

  • Jang, Sung-Roc;Ryoo, Hong-Je;Ok, Seung-Bok
    • Journal of Power Electronics
    • /
    • v.11 no.4
    • /
    • pp.612-619
    • /
    • 2011
  • This paper presents a water treatment system for leachate from sewage-filled ground that uses a pulsed-power modulator developed based on semiconductor switches in order to realize a long life, a high repetition rate, and a fast rising time. The specifications of the developed pulsed-power modulator are the pulsed output voltage, the output current, the pulse repetition rate (PRR), the pulse width, and an average output power of $60\;kV_{max}$, $300\;A_{max}$, 3000, $50\;{\mu}s$, and 15 kW, respectively. The pulsed-power water treatment system was introduced and analyzed using an equivalent electrical circuit model to optimize the output voltage waveform. The experimental results verify that the proposed water treatment system can be effectively used for industrial applications.

Algorithm for Maximum Degree Vertex Partition of Cutwidth Minimization Problem (절단 폭 최소화 문제의 최대차수 정점 분할 알고리즘)

  • Sang-Un Lee
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.24 no.1
    • /
    • pp.37-42
    • /
    • 2024
  • This paper suggests polynomial time algorithm for cutwidth minimization problem that classified as NP-complete because the polynomial time algorithm to find the optimal solution has been unknown yet. To find the minimum cutwidth CWf(G)=max𝜈VCWf(𝜈)for given graph G=(V,E),m=|V|, n=|E|, the proposed algorithm divides neighborhood NG[𝜈i] of the maximum degree vertex 𝜈i in graph G into left and right and decides the vertical cut plane with minimum number of edges pass through the vertex 𝜈i firstly. Then, we split the left and right NG[𝜈i] into horizontal sections with minimum pass through edges. Secondly, the inner-section vertices are connected into line graph and the inter-section lines are connected by one line layout. Finally, we perform the optimization process in order to obtain the minimum cutwidth using vertex moving method. Though the proposed algorithm requires O(n2) time complexity, that can be obtains the optimal solutions for all of various experimental data

Pharmacokinetic analysis for the development of new potent anti-HIV-1 agents, the KR-V series (새로운 항HIV-1제, KR-V series의 개발을 위한 약물동태연구)

  • Lee, Young-mi;Kim, Jin-suk;Han, Sang-seop;Shin, Ho-chul
    • Korean Journal of Veterinary Research
    • /
    • v.40 no.3
    • /
    • pp.471-478
    • /
    • 2000
  • The pharmacokinetic properties of KR-V compounds, recently developed as new anti-HIV agents, were studied after i.v. and p.o. administration in rats. The concentrations of the KR-V series were determined in rat plasma using an high-performance liquid chromatography (HPLC)-UV detection system. Of the 19 KR-V compounds investigated in the present study, only KR-V 3, 10, 14, 16 and 18-1 showed oral bioavailability. The plasma concentration-time data could be adequately described by an one-compartment open model. In the i.v. kinetic study (10mg/kg), the CLt of KR-V 3, 10, 14 and 16 (>4L/hr/kg) were significantly higher than that of KR-V 18-1 (1.1 L/hr/kg). The AUC of KR-V 18-1 was greater ($8.97{\mu}g{\cdot}hr/ml$) than that of the other compounds, but the Vd (0.58 L/kg) was lower. In the p.o. kinetic study (50mg/kg), although the t-1/2 of KR-V 18-1 was shorter than that of the other compounds, the AUC ($3.659{\mu}g{\cdot}hr/ml)$ and $C_{max}(1.891{\mu}g/ml$) were markedly higher. In a seperated in vitro experiment, only KR-V 18-1, of the 5 compounds with bioavailibility, exhibits potent activity against HIV-1 mutant strains. Therefore, KR-V 18-1 is expected to become a new potent anti-AIDS drug candidate/lead compound.

  • PDF