• Title/Summary/Keyword: time of loading

Search Result 2,546, Processing Time 0.03 seconds

A STUDY ON THE EAST/WEST STATION KEEPING PLANNING CONSIDERING WHEEL OFF-LOADING

  • Lee, Sang-Cherl;Park, Bong-Kyu;Kim, Bang-Yeop;Ju, Gwang-Hyeok;Yang, Koon-Ho
    • 대한원격탐사학회:학술대회논문집
    • /
    • 대한원격탐사학회 2006년도 Proceedings of ISRS 2006 PORSEC Volume I
    • /
    • pp.263-266
    • /
    • 2006
  • Now, on the developing COMS(Communication, Ocean and Meteorological Satellite) has solar panel on the South panel only. Therefore, the wheel off-loading has to be performed periodically to reduce a induced momentum energy by a asymmetric solar panel. One of two East/West station keeping maneuver to correct simultaneously longitude and eccentricity, orbit corrections may be performed during one of the two wheel off-loading manoeuvres per day to get enough observation time for meteorological and ocean sensor. In this paper, we applied a linearized orbit maneuver equation to acquire maneuver time and delta-V. Nonlinear simulation for the station keeping is performed and compared with general station keeping strategy for fuel reduction.

  • PDF

Development of implant loading device for animal study about various loading protocol: a pilot study

  • Yoon, Joon-Ho;Park, Young-Bum;Cho, Yuna;Kim, Chang-Sung;Choi, Seong-Ho;Moon, Hong-Seok;Lee, Keun-Woo;Shim, June-Sung
    • The Journal of Advanced Prosthodontics
    • /
    • 제4권4호
    • /
    • pp.227-234
    • /
    • 2012
  • PURPOSE. The aims of this pilot study were to introduce implant loading devices designed for animal study and to evaluate the validity of the load transmission ability of the loading devices. MATERIALS AND METHODS. Implant loading devices were specially designed and fabricated with two implant abutments and cast metal bars, and orthodontic expansion screw. In six Beagles, all premolars were extracted and two implants were placed in each side of the mandibles. The loading device was inserted two weeks after the implant placement. According to the loading protocol, the load was applied to the implants with different time and method, simulating early, progressive, and delayed loading. The implants were clinically evaluated and the loading devices were removed and replaced to the master cast, followed by stress-strain analysis. Descriptive statistics of remained strain (${\mu}{\varepsilon}$) was evaluated after repeating three cycles of the loading device activation. Statistic analysis was performed using nonparametric, independent t-test with 5% significance level and Friedman's test was also used for verification. RESULTS. The loading devices were in good action. However, four implants in three Beagles showed loss of osseointegration. In stress-strain analysis, loading devices showed similar amount of increase in the remained strain after applying 1-unit load for three times. CONCLUSION. Specialized design of the implant loading device was introduced. The loading device applied similar amount of loads near the implant after each 1-unit loading. However, the direction of the loads was not parallel to the long axis of the implants as predicted before the study.

Effect of Biofilter Operation Parameters on Dimethyl Disulfide Removal : Loading, Time, and Concentration

  • Arpacioglu, Bora C.;Kim, Jo-Chun;Allen, Eric R.;Kim, Seoung-Hyun
    • 한국환경과학회지
    • /
    • 제11권8호
    • /
    • pp.783-791
    • /
    • 2002
  • A laboratory-scale dual-column biofilter system was used to study the biofiltration of dimethyl disulfide(DMDS). The biofiltration of DMDS was found to depend on the pollutant loadings rather than the inlet concentrations. It was estimated that the pollutant was only inhibitory to the operation of the biofilters at DMDS concentrations greater than 5500 ppmv A residence time of 30 seconds(120 m$^3$/m$^2$/h volumetric loading) was determined as appropriate for efficient operation(>90%). The maximum elimination capacity for both compost mixtures under the current experimental conditions was found to range from 7.5 to 10 g-DMDS/m$^3$/h. A lower DMDS maximum elimination capacity was exhibited under acidified conditions.

컨테이너선의 적재계량에 관한 연구 (On the Loading Plan of Container Ship)

  • 강기중;이철영
    • 한국항해학회지
    • /
    • 제14권4호
    • /
    • pp.1-15
    • /
    • 1990
  • With increasing ship's speed turnround and port time becomes a large percentage of total roundtrip time and this causes to accelerate the introduction of the various kind of modern handling equipment, the standardization of cargoes, and the improvement of the ship. However, it is still a drag on efficient operation of ship. Similarly, the turnround time at the container port is very important as a measure for the decision of the efficiency of port. To decrease operating coasts, the minimization of the time need to cargo handling at the ports of call must be achieved. Thus the optimization of the time need to cargo handling at the ports of call must be achieved. Thus the optimized Container Loading Plan is necessary, especially under the rapid speed of container operations. For the container loading plan, in this thesis, we use the hungarian method and the branch and bound method to get the initial disposition of both maximization of ship's GM and minimization of shift number to the obstructive container in a yard area. We apply the dynamic programming algorithm to get the final disposition for minimizing total turnroudn time and finally we analyzed the results to check whether the initial disposition is proper or not.

  • PDF

광주 도심지역에서 측정한 Aethalometer 검댕입자 자료의 보정 (Compensation of Aethalometer Black Carbon Data Observed at a Gwangju Site)

  • 박승식;정정훈;조성용;김승재
    • 한국대기환경학회지
    • /
    • 제25권6호
    • /
    • pp.571-578
    • /
    • 2009
  • $PM_{2.5}$ black carbon (BC) concentrations were measured to investigate the filter spot loading effect in raw BC data at 5-minute time-based resolution using a single-wavelength aethalometer at a Gwangju site. Also the elemental carbon (EC) concentrations from 24-hr integrated filter-based measurements of $PM_{2.5}$ particles were determined to compare with the loading compensated BC values. Close examination of the time-series BC data showed clearly the "gaps" when the filter tape advances, suggesting the correction of raw BC data. Therefore, we calculated the average BC concentration in each range of attenuation (ATN) to decide if there was (or was not) an effect on the aethalometer data according to the loading of the filter spot. A consistent decrease of average BC concentration was found with increasing ATN values for every month, suggesting there was a consistent "spot loading effect" in the raw BC data. The loading compensated BC concentration according to a simple compensation model with loading effect was 1.01~1.15 times greater than the raw BC data. The 24-hr average concentration of EC observed during summer sampling period was about 3% higher than the original 24-hr average BC value and 2% lower than the loading compensated BC concentration.

추계론적 유한 요소법을 이용한 동하중을 받는 비선형 구조물의 안전성 평가 (Nonlinear Structural Safety Assessment under Dynamic Excitation Using SFEM)

  • Huh, Jungwon
    • 한국전산구조공학회논문집
    • /
    • 제13권3호
    • /
    • pp.373-384
    • /
    • 2000
  • 단기 동 하중(특히 지진하중)을 받는 비선형 강 프레임 구조물의 안전성을 평가하기 위하여 추계론적 유한요소 개념에 근거한 비선형 시간영역 신뢰성 해석 기법을 제안하였다. 제안된 알고리즘에서는 유한요소 공식화가 응답 표면법, 1차 신뢰성 방법, 그리고 반복 선형보간 기법의 개념들과 결합되어 지는데, 이것이 추계론적 유한요소 개념으로 귀결된다. 실제 지진하중의 시간이력이 구조물의 진동을 위해 사용되므로 사실적인 하중조건의 재현이 가능하다. 가상 응력에 기초한 유한요소 기법이 본 알고리즘의 효율성을 증대하기 위해 사용된다. 본 알고리즘은 지진하중 또는 임의의 단기 동적하중을 받는 유한요소 기법으로 표현되는 어떠한 선형 및 비선형 구조물과 관련된 위험도를 평가할 수 있는 잠재성을 가지고 있다. 수치예제를 통하여 알고리즘을 설명하였으며, 몬테카를로 시뮬레이션 기법을 사용하여 본 알고리즘을 검증하였다.

  • PDF

통신해양기상위성의 휠오프로딩 지상국 소프트웨어 검증시험 (Ground Software Validation Test for Wheel Off-loading of COMS)

  • 박영웅;양군호
    • 항공우주기술
    • /
    • 제9권2호
    • /
    • pp.51-56
    • /
    • 2010
  • 통신해양기상위성의 정상임무 수행시 자세제어계에 대한 중요한 지상국 소프트웨어에는 궤도위치 유지와 휠오프로딩이 있는데, 본 논문에서는 외팔보 태양전지판 형상으로 인해 E3000 heritage로부터 설계 변경을 수행하여 해석을 수행한 휠오프로딩 임무에 대한 지상국 소프트웨어 검증시험을 정리하여 기술하였다. 휠오프로딩 지상국 소프트웨어는 크게 2가지로 구분되는데, 하나는 휠오프로딩을 위한 추력기 조합 변경 시기에서의 변수 변경이고 다른 하나는 위성으로 전달해야 하는 모멘텀기준값 변경이다.

Unique local deformations of the superelastic SMA rods during stress-relaxation tests

  • Ashiqur Rahman, Muhammad;Rahman Khan, Mujibur
    • Structural Engineering and Mechanics
    • /
    • 제22권5호
    • /
    • pp.563-574
    • /
    • 2006
  • This paper studies mechanical behavior of the superelastic shape memory alloy (SMA) rods in terms of local deformations and time via tensile loading-unloading cycles for both ends fixed end constraints. Besides the unique stress induced martensitic transformation (SIMT), SMA's time dependent behavior when it is in mixed-phase condition upon loading and unloading, also need careful attention with a view of investigating the local deformation of the structural elements made of the same material. With this perspective, the so-called stress-relaxation tests have been performed to demonstrate and investigate the local strains-total strains relationships with time, particularly, during the forward SIMT. Some remarkable phenomena have been observed pertaining to SIMT, which are absent in traditional materials and those unique phenomena have been explained qualitatively. For example, at the stopped loading conditions the two ends (fixed end and moving end of the tensile testing machine) were in fixed positions. So that there was no axial overall deformation of the specimen but some notable increase in the axial local deformation was shown by the extensometer placed at the middle of the SMA specimen. It should be noted that this peculiar behavior termed as 'inertia driven SIMT' occurs only when the loading was stopped at mixed phase condition. Besides this relaxation test for the SMA specimens, the same is performed for the mild steel (MS) specimens under similar test conditions. The MS specimens, however, show no unusual increase of local strains during the stress relaxation tests.

STS316L의 고온피로균열에 미치는 인장유지시간의 효과 및 결정립크기에 따른 크리프 거동에 관한 연구 (The Effect of Tensile Hold time on the Fatigue Crack Propagation Property and Grain Size on the Creep Behavior in STS 316L.)

  • 김수영
    • 한국공작기계학회:학술대회논문집
    • /
    • 한국공작기계학회 2000년도 춘계학술대회논문집 - 한국공작기계학회
    • /
    • pp.373-378
    • /
    • 2000
  • The heat resistant material, in service, may experience static loading, cyclic loading, or a combination of two. An experimental study of crack growth behavior of STS 316L austenitic stainless steel under fatigue, and creep-fatigue loading conditions were carried out on compact tension specimens at various tensile hold times. In the crack growth experiments under hold times. In the crack growth experiments under hold time loading conditions, tensile hold times were ranged from 5 seconds to 100 seconds and its behavior was characterized using the $\Delta$K parameter. The crack growth rates generally increase with increasing hold times. However in this material, the trend of crack growth rates decreases with increasing hold times for short hold time range relatively. It is attributed to a decline in the cyclic crack growth rate as a result of blunting at the crack tip by creep deformation. The effect of grain size on the creep behavior of STS 316L was investigated. Specimens with grain size of 30, 65 and 125${\mu}{\textrm}{m}$ were prepared through various heat treatments and they were tested under various test conditions. The fracture mode of 316L changed from transgranular to intergranular with increasing grain size.

  • PDF

Experimental study on the dynamic behavior of pervious concrete for permeable pavement

  • Bu, Jingwu;Chen, Xudong;Liu, Saisai;Li, Shengtao;Shen, Nan
    • Computers and Concrete
    • /
    • 제22권3호
    • /
    • pp.291-303
    • /
    • 2018
  • As the concept of "sponge city" is proposed, the pervious concrete for permeable pavement has been widely used in pavement construction. This paper aims at investigating the dynamic behavior and energy evolution of pervious concrete under impact loading. The dynamic compression and split tests are performed on pervious concrete by using split Hopkinson pressure bar equipment. The failure criterion on the basis of incubation time concept is used to analyze the dynamic failure. It is demonstrated that the pervious concrete is of a strain rate sensitive material. Under high strain rate loading, the dynamic strength increases while the time to failure approximately decreases linearly as the strain rate increases. The predicted dynamic compressive and split tensile strengths based on the failure criterion are in accordance with the experimental results. The total damage energy is found to increase with the increasing of strain rate, which means that more energy is needed to produce irreversible damage as loading rate increases. The fractal dimensions are observed increases with the increasing of impact loading rate.