• 제목/요약/키워드: time of concentration ratio

검색결과 1,290건 처리시간 0.028초

시간활동양상에 따른 주택의 시간대별 실내·실외 초미세먼지 농도비 (Indoor to Outdoor Ratio of Fine Particulate Matter by Time of the Day in House According to Time-activity Patterns)

  • 박진현;김은채;최영태;류현수;김순신;우병렬;조만수;양원호
    • 한국환경보건학회지
    • /
    • 제46권5호
    • /
    • pp.504-512
    • /
    • 2020
  • Objective: The purpose of this study was to evaluate the indoor to outdoor ratio (I/O ratio) of time activity patterns affecting PM2.5 concentrations in homes in Korea through a simulation. Methods: The time activity patterns of homemakers were analyzed based on the 'Time-Use Survey' data of the National Statistical Office in 2014. From September 30 to October 2, 2019, the experimenter lived in multifamily housing located in Guro-gu, Seoul. The I/O ratio of PM2.5 concentration was measured by installing sensor-based instruments. Results: The average indoor and outdoor PM2.5 concentrations during the three days were 33.1±48.9 and 45.9±25.3 ㎍/㎥, respectively. The average I/O ratio was 0.75±0.60. The indoor concentration tended to increase when PM2.5 source activity such cooking and cleaning was present and outdoor PM2.5 was supplied through ventilation. Conclusions: This study could be used as basic data for estimating indoor PM2.5 concentrations with personal activity pattern and weather conditions using outdoor concentrations.

세라믹막을 이용한 Lactobacillus cell의 농축 공정의 특성 (Characteristics of the Concentration Process of Lactobacillus Cell Using a Ceramic Membrane)

  • 이용택;송민호
    • 멤브레인
    • /
    • 제14권3호
    • /
    • pp.192-200
    • /
    • 2004
  • 본 연구에서는 유기질막에 비해 안정성이 우수하고 사용수명이 긴 세라믹 막을 이용하여 혐기성 Lactobacillus 균주의 농축에 관해서 연구하였다. Cell harvesting (CH)에 영향을 주는 인자로 막투과 압력, 온도, 선속도 등에 대해 조사하였으며 세라믹 막을 이용하여 농축율 변화에 따른 플럭스와 TMP (transmembrane pressure)의 변화, 일정 VCF(volumetric concentration factor)에서 TMP변화 등의 최적조건에 관해 알아보았다. 그 결과 플럭스는 TMP, 선속도, VCF가 증가함에 따라 투과수량도 증가함을 알 수 있었다. 온도가 증가할수록 점도에 의해 초기 플럭스도 증가하지만 시간이 경과함에 따라 막 표면의 겔층의 형성으로 온도의 영향은 미미하였다. 또한 농축비 이하의 일정한 VCF에서 운전할 경우 플럭스가 안정적임을 알 수 있었다. 선속도 5 m/s, 공급액의 온도 $37^{\circ}C$, TMP 1 bar에서 6∼8 h 운전할 경우 PS 406 원액의 생균수는 4.9{\times}10^9$으로 약 8배 농축됨을 알 수 있었다.

서울시 지하철 2호선의 가을철 객실 PM2.5 농도의 특성 (Characteristics of In-cabin PM2.5 Concentration in Seoul Metro Line Number 2 in Autumn)

  • 신혜린;정현희;이기영
    • 한국환경보건학회지
    • /
    • 제45권2호
    • /
    • pp.186-191
    • /
    • 2019
  • Objectives: Subway is one of the most common transportation modes in Seoul, Korea. The objectives of this study were to determine characteristics of in-cabin $PM_{2.5}$ concentration in Seoul Metro Line Number 2 and to identify factors of the $PM_{2.5}$ concentration. Methods: In-cabin $PM_{2.5}$ concentrations in Seoul Metro Line Number 2 were measured using real-time monitors and the factors affecting $PM_{2.5}$ concentration in cabin were observed. Linear regression analysis of in-cabin $PM_{2.5}$ concentration and indoor/outdoor (I/O) ratio were performed. Results: In-cabin $PM_{2.5}$ concentration was associated with the in-cabin $PM_{2.5}$ concentration in previous station. In-cabin $PM_{2.5}$ concentration was correlated with ambient $PM_{2.5}$ concentration and associated with underground station with control of the in-cabin $PM_{2.5}$ concentration in previous station. I/O ratio increased as the number of passengers increased and when passing through the underground station with control of I/O ratio in previous station. Conclusion: In-cabin $PM_{2.5}$ concentration was affected by ambient $PM_{2.5}$ concentration. Therefore, management of in-cabin $PM_{2.5}$ concentrations should be based on outdoor air quality.

외기 오존 농도에 따른 반도체 작업환경 및 사무실에서의 오존 농도 변화 연구 (A Study of Ozone Variations in a Semiconductor Fabrication Facility and Office Related to the Ozone Concentration in the Outdoor Air)

  • 이지은;정명구;최광민
    • 한국산업보건학회지
    • /
    • 제26권2호
    • /
    • pp.188-197
    • /
    • 2016
  • Objectives: The purpose of this study was to evaluate the ozone exposure levels and the variations in ozone concentration in a semiconductor fabrication facility and office in relation to the ozone concentration in the outdoor air. Methods: This study was performed in an office, semiconductor fabrication facility(such as etching, diffusion, diffusion plenum), and outdoors from June to August, 2015. Measurements were taken six times at the same places using an active sampler(pumped) and real-time equipment. Ozone monitoring by the active sampler method and analysis were carried out by OSHA Method ID-214. Real-time measurement was carried out by ozone measuring equipment using a non-dispersive ultraviolet absorption method. Results: Ozone concentrations in the semiconductor fabrication facility and office were 0.7~7.1 ppb in area samples and 0.72~4.07 ppb in real-time measurement, which were 0.88~8.88% of the occupational exposure limit. The concentration of ozone generated by a laser printer in the office was less than 2 ppb. There was not a significant difference between ozone concentrations before and after using the laser printer. The indoor/outdoor concentration ratio(I/O ratio) in the semiconductor fabrication facility and office was 0.05 and 0.06, respectively. Conclusions: All the samples contained ozone levels lower than the occupational exposure limit and it was confirmed that the concentration of outdoor ozone had no significant effect on indoor ozone concentration.

Water purification from pesticides by spiral wound nanofiltration membrane

  • Bottino, A.;Capannelli, G.;Comite, A.;Ferrari, F.;Firpo, R.
    • Membrane and Water Treatment
    • /
    • 제2권1호
    • /
    • pp.63-74
    • /
    • 2011
  • A spiral wound nanofiltration (NF) membrane (GE Osmonics, DK 4040F) was used to remove pesticides from water. Several solutions of single pesticides and their mixtures were prepared. The pesticides initial concentration ranged from ca. 50 ng/L (single pesticide) to ca. 700 ng/L (as sum of 14 pesticides) and progressively increased with time since the NF experiments were carried out in a concentration mode up to a Volume Concentration Ratio, VCR = 10. Permeate flux and pesticides retention were evaluated as a function of the Volume Concentration Ratio. The permeate flux did not practically change by varying VCR. Pesticide retention was found to be around 97-98% both in the cases of single pesticide solutions and different mixtures of pollutants, and was not affected by the VCR. Pesticides concentration in permeate samples was found to be lower than the maximum concentration level fixed in European directive.

HALOE 자료를 이용한 중위도 지역의 오존농도 추이분석 (Trend Analysis for Stratospheric Ozone Concentration in the Middle Latitude Northern Hemisphere Using HALOE Data)

  • 가수현;권미라;오정진
    • 한국대기환경학회지
    • /
    • 제21권4호
    • /
    • pp.413-422
    • /
    • 2005
  • The ozone concentration measured by HALOE (Ver 19) from Oct. 1991 to Dec. 2003 is used for analyzing the variation of ozone concentration. The HALOE loaded in UARS is observing several gases in the atmosphere, from 10km to 80km. Fourier analysis of these data in the middle latitude northern hemisphere is reported in this paper. To detect any possible long term trends, the fourier transformed time series was back transformed after removing signals with time periods of less than 6 months. Although the results clearly show the strong annual cycle, it is difficult to show any long term trends from the fourier series. We also compared the ozone volume mixing ratio's from HALOE with that from the ground-based radiometry to evaluate the accuracy of microwave observation at Sookmyung Women's University.

전해질 성분 및 농도, 이온교환 수지 비율에 따른 이온교환 특성 연구 (A Study on Ion Exchange Characteristics with Composition and Concentration of Electrolyte, Ratio of Ion Exchange Resin)

  • 안현경;이인형;윤형준;정현준
    • 한국산학기술학회논문지
    • /
    • 제7권4호
    • /
    • pp.727-732
    • /
    • 2006
  • 본 연구에서는 전해질 성분 및 농도, 이온교환 수지 조성비율을 통해 이온교환 수지탑의 성능을 평가하고, 이온교환 수지에 의한 입자성 물질 제거의 능력과 입자성 물질이 이온교환 특성에 미치는 영향을 조사하였다. 이온교환 수지탑 배열 순서에 따라 파과(돌파)시점이 연장되며, 파과(돌파)순서는 음이온의 경우 $Cl^{-}, 양이온의 경우 $Na^{+} 순 이였으며, 전해질의 농도가 증가할수록 파과시간이 단축되었다. 이온교환 수지의 조성비 변화에서는 양음이온교환 수지 조성비가 1:2의 경우 1:1및 1:3의 경우보다 파과(돌파)시간이 연장되었으며 동일한 전해질 농도에서 입자 농도가 증가하면 20% 미만으로 파과(돌파)시간이 단축되었다. 양이온 교환수지 비율이 높으면 양이온의 파과(돌파)시점이 늦어져 이온교환 수지탑의 수명이 연장되고, 입자성 물질은 전해질 농도와 무관하게 이온교환 수지의 세공을 막아 이온교환 용량을 감소시켜 파과(돌파)시간을 단축시키는 것으로 조사되었다.

  • PDF

단백포소화약제의 유동성 변화에 따른 소화 특성 (The Extinguishing Characteristics by Fluidity Variation of Protein Foam Extinguishing Agent)

  • 신창섭;정현정
    • 한국안전학회지
    • /
    • 제29권2호
    • /
    • pp.18-23
    • /
    • 2014
  • Foam extinguishing agent is widely used for extinguishing combustible liquid fires. Compared to other foam type extinguishing agents, protein foam has relatively low cost and low toxicity and produces stable foam blanket which is excellent in heat resistance and sealability, despite it has weak fluidity. Therefore the study investigated foaming characteristics followed by various factors affecting the fluidity of the protein foam extinguishing agent. The extinguishing characteristics differentiated by the changes in fluidity were also experimented. Foaming performance was compared by measuring the expansion ratio and the 25% drainage time. Moreover, the 25% drainage time and the extinguishing time was compared. The results showed that the 25% drainage time and the expansion ratio were increased as the pressure of nozzle and the concentration of hydrolyzed protein liquid enlarged. However the foaming and extinguishing performance were not improved when the condition exceeded certain level of pressure and concentration. The fastest fire extinguishing condition was the nozzle pressure 4bar with the 85wt.% of concentration of hydrolyzed protein liquid.

정적연소기에서의 메탄-공기 혼합기의 연소특성(3) : 배기배출물 (Combustion Characteristics of Methane-Air Mixture in a Constant Volume Combustion Chamber(3) : Exhaust Emission)

  • 최승환;전충환;장영준
    • 한국자동차공학회논문집
    • /
    • 제12권2호
    • /
    • pp.1-8
    • /
    • 2004
  • A cylindrical constant volume combustion chamber was used to investigate the exhaust emission characteristics of homogeneous charge, stratified pattern and inhomogeneous charge under various conditions using gas chromatography. In the case of homogeneous charge condition, the $CO_2$ concentration is proportional to excess air ratio and overall charge pressure, the $CO_2$ concentration is proportional to excess air ratio and the UHC concentration is inversely proportional to ignition time and overall charge pressure. In the case of stratified pattern, the RI(rich injection) condition shows better exhaust emission characteristics, especially $CO_2$, than that of HI (homogeneous injection) or LI (lean injection) conditions. In inhomogeneous charge conditions, when initial charge pressure is increased, $CO_2$ and UHC concentration is reduced but $O_2$ concentration is increased. And when the excess air ratio of initial charge mixture is 3.0, UHC and $CO_2$concentration show lowest values.

Phenol 함유폐수의 처리를 위한 영향인자와 성능특성 (Influence factors and Efficiencies Characteristics for Treatment of Wastewater Containing Phenol)

  • 강선태;김정목
    • 상하수도학회지
    • /
    • 제10권4호
    • /
    • pp.119-126
    • /
    • 1996
  • Influence factors and efficiency characteristics for treatment of wastewater containing phenol were studied with using Pseudomonas sp. B3. It took 130 hours to remove phenol, when only activated sludge of terminal disposal palnt of sewage was innoculated in batch culture, but it was required just 36 hours, when bacteria degrading phenol and activated sludge were simultaneously innoculated. If only phenol an carbon source was used, it necessary 36 hours for biodegradation of phenol, while glucose was added to medium, it took 73 hours. It was revealed as excellent effluent and SVI, when the F/M ratio, COD and phenol concentration were 53mg/l and 1.2mg/l, respectively, and optimum F/M ratio was revealed 0.31. The reactor were seriously shocked as reducing hydraulic retention time at constant phenol concentration more than increasing phenol concentration at constant hydraulic retention time, when volumetric loading rate was increased to $0.8kg\;phenol/m^3{\codt}d$ from $1.6kg\;phenol/m^3{\codt}d$. And also the effluent phenol concentration was 34mg/l after starting 12 hours of shocking and reactor was recovered as steady state after 65 hours of changing in the former test. Although the effluent phenol concentration was maximum value with 12mg/l after starting 20 hours of shocking and reactor was recovered as steady state after 54 hours of changing in the later test.

  • PDF