• Title/Summary/Keyword: time interval signal

Search Result 302, Processing Time 0.068 seconds

A New Algorithm for P_wave Detection in the ECG signal (심전도 신호 P파 검출 알고리즘에 관한 연구)

  • Joang, Hee-Kyo;Kim, Kwang-Keun;Hwang, Sun-Chul;Lee, Myoung-Ho
    • Proceedings of the KOSOMBE Conference
    • /
    • v.1989 no.05
    • /
    • pp.15-18
    • /
    • 1989
  • This paper presents a new algorithm for P-wave detection in the ECG signal. We detect the peak and valley point using significant point extraction algorithm with 9-point derivative. Because P-wave duration is changed according to heart-rates, we search for the R-peak and calculate the R-R interval time prior to the determination of P-wave duration threshold values in order to actively adapt to the change of P duration. We determine the parameters for P-wave detection and then P-peak, P-onset and P-offset are detected by these parameters. The results obtained from the proposed algorithm have detected successively P-wave almost more than 90%.

  • PDF

스토케스틱 방법에 의한 공작기계의 안정성 해석

  • Kim, Gwang-Jun
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.1 no.1
    • /
    • pp.34-49
    • /
    • 1984
  • The stability of machine tool systems is analyzed by considering the machining process as a stochastic process without decomposing into machine tool structural dynamics and cutting processes. In doing so the time series analysis technique developed by Wu and Pandit is applied systematically to the relative vibration between cutting tool and work- piece measured under actual working conditions. Various characteristic properties derived from the fitted ARMA(Autoregressive Moving Average) Models and those from raw data directly are investigated in relation with the system stability. Both damping ratio and absolute value of the characteristic roots of the AR part of the most significant dynamic mode are preferred as stability indicating factors to the other pro-perties such as theoretical variance .gamma. (o) or absolute power of the most dominant dynamic mode. Maximum aplitude during a certain interval and variance estimated from raw data are shown to be very sensi- tive to the type of the signal and the location of measurement point although they can be obtained rather easily. The relative vibration signal is also analyzed by FFT(Fast Fourier Transform) Analyzer for the purpose of comparison with the spectrums derived from the fitted ARMA models.

  • PDF

A DSP System for On-line Monitoring in Laser Welding Using a IR and UV Sensors (IR 및 UV센서를 이용한 레이저 용접시의 실시간 모니터링 DSP 시스템)

  • Yoon Choong-Sup
    • Journal of Welding and Joining
    • /
    • v.23 no.4
    • /
    • pp.53-58
    • /
    • 2005
  • We designed a weld monitoring system with UV and IR sensors using a embedded DSP controller for implementing a distribution system; running stand alone and communication with outside by industrial standard protocols. Also this system provided a USB port in order to be acquiring data in PC. The user interface program in PC visualized the IR and W data in time, frequency and state space. A correlation of IR and UV signals showed closely related to weld quality. A rapid change of geometry can be found through a moving average filter. And the average value of IR signal at an interval represented a welding width and depth. Through these results, we proposed a monitoring algorithm for a integer type DSP.

A Stable Pitch ]Determination via Dyadic Wavelet Transform (DyWT) (Dyadic Wavelet Transform 방식의 Pitch 주기결정)

  • Kim Namhoon;Yoon Gibum;Ko Hanseok
    • Proceedings of the Acoustical Society of Korea Conference
    • /
    • autumn
    • /
    • pp.197-200
    • /
    • 2000
  • This paper presents a time-based Pitch Determination Algorithm (PDA) for reliable estimation of pitch Period (PP) in speech signal. In proposed method, we use the Dyadic Wavelet Transform (DyWT), which detects the presence of Glottal Closure Instants (GCI) and uses the information to determine the pitch period. And, the proposed method also uses the periodicity property of DyWT to detect unsteady GCI. To evaluate the performance of the proposed methods, that of other PDAs based on DyWT are compared with what this paper proposed. The effectiveness of the proposed method is tested with real speech signals containing a transition between voiced and the unvoiced interval where the energy of voiced signal is unsteady. The result shows that the proposed method provides a good performance in estimating the both the unsteady GCI positions as well as the steady parts.

  • PDF

The Advanced z-Transform and Analysis of Sampled-Data Systems

  • Chung, Tae-Sang
    • Proceedings of the KIEE Conference
    • /
    • 1996.11a
    • /
    • pp.49-51
    • /
    • 1996
  • The z-transform method is a basic mathematical tool in analyzing and designing sampled-data control systems. However, since the z-transform method relates only the sampling-instants signals, another mathematical tool is necessary to describe the continous signals between the sampling instants. For this purpose the delayed and the modi fled z-transform methods were developed. The definition of the modi fled z-transform includes a sample in the interval [-T,0] of the original signal in its series expression, where the signal value is always zero for any physical system. From this reason one step skew of the time index always appears in its application formulas. This introduces an unnecessary operation and a gap in linking the mathematical formula and its physical interpretation. Considering the conceptual difficulty and application inconvenience, a method of using the advanced z-transform in analysis of sampled-data control systems is developed as a replacement of the modi fled z-transform. With one formulation of the advanced z-transform, now it is possible to relate both the signals of the sampling instants and those in between without any complication and conceptual difficulty.

  • PDF

Echolocation Signals of Pipistrellus abramus in Relation to Environmental Type (환경특성에 따른 집박쥐의 반향정위(Echolocation) 시그널 분석)

  • Chung, Chul-Un;Han, Sang-Hoon;Kim, Sung-Chul;Lee, Chong-Il
    • Korean Journal of Environment and Ecology
    • /
    • v.23 no.6
    • /
    • pp.553-563
    • /
    • 2009
  • This study was conducted to analyze the changes in the echolocation of Pipistrellus abramus according to environmental characteristics. The survey was conducted in the day-roosting site of P. abramus located in Gyeongju City (North Gyeongsang Province) from April to August, 2009. The environmental characteristics during the research were classified in six categories: the emergence time after sunset moving time from day roost to feeding areas; rice fields; forest edges; open spaces; and residential areas. Analysis results showed that there are differences in environmental characteristics and also differences between the moving time to the habitat and the moving time to capture preys. At the emergence time from day roost, Pipistrellus abramus used a FM signal with a short pulse-duration. In open spaces, however, they used a CF signal with a long pulse-duration. In different environmental situations, they used both FM and CF signals, although the types of pulse which they used were different. Except pulse-duration, there were significant differences in pulse-interval, peak-frequency, starting-frequency and ending-frequency between the movement among habitats and the movement to capture preys. Except the emergence time from day-roost, they showed a narrow band FM signal and a long pulse-duration that are suitable to search for insects by sensing echoes of insects when they moved among their habitats. When they were out to capture their preys, they showed a broad band FM signal and a short pulse-duration which enabled them to widely search and accurately locate their preys.

Beacon Geolocation Scheme of COSPAS-SARSAT System for Heavy Disaster Environment (다중 재난 상황에 적합한 COSPAS-SARSAT 탐색구조 비컨 위치추정 기법)

  • Kim, Jaehyun;Lee, Sanguk;Sin, Cheonsig;Ahn, Woo-Geun
    • Journal of Satellite, Information and Communications
    • /
    • v.10 no.4
    • /
    • pp.146-150
    • /
    • 2015
  • The COSPAS-SARSAT committee decides MEOSAR (Medium-Earth Orbit for search and rescue) service development for installing 406MHz SAR instruments on their respective MEO navigation satellite system of the United States, EU, and Russia, since 2000. The transmitted beacon signal is separately arrived by satellites with different FOA (Frequency of Arrival) and TOA (Time of Arrival). It is directly transferred to MEOLUT. In MEOLUT, a LUT track at least 3 or 4 satellites simultaneously and estimate location of beacon using time difference of arrival (TDOA) and frequency difference arrival (FDOA). But the transmitted distress signals may be overlapped each other because the distress beacons transmit signal on mean interval of 50 seconds in arbitrary time. It's difficult that simultaneously estimate location of beacon by current scheme for several overlapped distress signal. So we use cross ambiguity function (CAF) Map algorithm and present Multi-CAF MAP scheme in order to satisfy performance requirement of system. The performance is analyzed for COSAPS-SARSAT MEOSAR.

Efficient Implementation of FMCW Radar Signal Processing Parts Using Low Cost DSP (저가형 DSP를 사용하는 FMCW 레이더 신호처리부의 효율적 구현 방안)

  • Oh, Woojin
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.20 no.4
    • /
    • pp.707-714
    • /
    • 2016
  • Active driving safety systems for vehicle, such as the front collision avoidance, lane departure warning, and lane change assistance, have been popular to be adopted to the compact car. For improving performance and competitive cost, FMCW radar has been researched to adopt a phased array or a multi-beam antenna, and to integrate the front and the side radar. In this paper we propose several efficient methods to implement the signal processing module of FMCW radar system using low cost DSP. The pulse width modulation (PWM) based analog conversion, the approximation of time-eating functions, and the adoption of vector-based computation, etc, are proposed and implemented. The implemented signal processing board shows the real-time performance of 1.4ms pulse repetition interval (PRI) with 1024pt-FFT. In real road we verify the radar performance under real-time constraints of 10Hz update time.

The Processing Method of Stream Data in the Small-size Operating System (소규모 운영체제에서의 스트림데이터 처리기법)

  • Kim, Jin-Deog
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2007.10a
    • /
    • pp.871-874
    • /
    • 2007
  • Stream data need a efficient data management with high reliability and real time processing. The characteristics of these data are a large volume, a short report interval and asynchronous report time. The typical queries of these systems consist of the current query to search the latest signal value, the snapshot query to search the signal value of a past time, the historical query to search the signal value of a past time to current. This paper proposes the efficient method to manage the above signals by using a file structured database in QNX operating systems. The query model to accommodate various query for stream data is proposed. The proposed methods are applied to reactive protection system to verify their usefulness. The COM(Cabinet Operator Module) based on the QNX employs file database that adopts a delta version and a buffering method for the resource limit of a small storage and a low computing power.

  • PDF

An Efficient Real Time Processing Method for Frequently Updated Data (빈번한 변경이 요구되는 데이터의 효율적인 실시간 처리 기법)

  • Kim Jin-Deog;Jin Kyo-Hong;Lee Sung-Jin;Jung Hae-Won
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2006.05a
    • /
    • pp.461-465
    • /
    • 2006
  • Recently, the operator modules to control external devices are concerned about automatic management system to process continuously changed signals. They need a efficient data management with high reliability and real time processing. The characteristics of these data are a large volume, a short report interval and asynchronous report time. The typical queries of these systems consist of the current query to search the latest signal value, the snapshot query to search the signal value of a past time, the historical query to search the signal value of a past tine to current. In this paper, we propose the efficient method to manage the above signals by using a file structured database in QNX operating systems. The data communications among the devices are done by Profibus-FMS protocol and the file databases are used for adjusting monitoring frequency and storing signals. The file database adopts a delta version and a periodical back up in due consideration of the resource limit of a small storage and a low computing power in QNX COM(Cabinet Operator Module).

  • PDF