• Title/Summary/Keyword: time correlation

Search Result 7,291, Processing Time 0.046 seconds

Soil Classification of Paddy Soils by Soil Taxonomy (미국신분류법(美國新分類法)에 의(依)한 답토양의 분류(分類)에 관한 연구)

  • Joo, Yeong-Hee;Shin, Yong-Hwa
    • Korean Journal of Soil Science and Fertilizer
    • /
    • v.11 no.2
    • /
    • pp.97-104
    • /
    • 1979
  • According to Soil Taxonomy which has been developed over the past 20 years in the soil conservation service of the U. S. D. A, Soils in Korea are classified. This system is well suited for the classification of the most of soils. But paddy field soils have some difficulties in classification because Soil Taxonomy states no proposals have yet been developed for classifying artificially irrigated soils. This paper discusses some problems in the application of Taxonomy and suggestes the classification of paddy field soils in Korea. Following is the summary of the paper. 1. Anthro aquic, Aquic Udipsamments : The top soils of these soils are saturated with irrigated water at some time of year and have mottles of low chroma(2 or less) more than 50cm of the soil surface. (Ex. Sadu, Geumcheon series) 2. Anthroaquic Udipsamments : These sails are like Anthroaquic, Aquic Udipsamments except for the mottles of low chroma within 50cm of the soil surface. (Ex. Baegsu series) 3. Halic Psammaquents : These soils contain enough salts as distributed in the profile that they interfere with the growth of most crop plants and located on the coastal dunes. The water table fluctuates with the tides. (Ex. Nagcheon series) 4. Anthroaquic, Aquic Udifluvents : They have some mottles that have chroma of 2 or less in more than 50cm of the surface. The upper horizon is saturated with irrigated water at sometime. (Ex. Maryeong series) 5. Anthro aquic Udifluvents : These soils are saturated with irrigated water at some time of year and have mottles of low chroma(2 or less) within 50cm of the surface soils. (Ex. Haenggog series) 6. Fluventic Haplaquepts : These soils have a content of organic carbon that decreases irregularly with depth and do not have an argillic horizon in any part of the pedon. Since ground water occur on the surface or near the surface, they are dominantly gray soils in a thick mineral regolith. (Ex Baeggu, Hagseong series) 7. Fluventic Thapto-Histic Haplaquepts : These soils have a buried organic matter layer and the upper boundary is within 1m of the surface. Other properties are same as Fluventic Haplaquepts. (Ex. Gongdeog, Seotan series) 8. Fluventic Aeric Haplaquepts : These soils have a horizon that has chroma too high for Fluventic Haplaquepts. The higher chroma is thought to indicate either a shorter period of saturation of the whole soils with water or some what deeper ground water than in the Fluventic Haplaquepts. The correlation of color with soil drainage classes is imperfect. (Ex. Mangyeong, Jeonbug series) 9. Fluventic Thapto-Histic Aeric Haplaquepts : These soils are similar to Fluventic Thapto Histic Haplaquepts except for the deeper ground water. (Ex. Bongnam series) 10. Fluventic Aeric Sulfic Haplaquepts : These soils are similar to Fluventic Aeric Haplaquepts except for the yellow mottles and low pH (<4.0) in some part between 50 and 150cm of the surface. (Ex. Deunggu series) 11. Fluventic Sulfaquepts : These soils are extremely acid and toxic to most plant. Their horizons are mostly dark gray and have yellow mottles of iron sulfate with in 50cm of the soil surface. They occur mainly in coastal marshes near the mouth of rivers. (Ex. Bongrim, Haecheog series) 12. Fluventic Aeric Sulfaquepts : They have a horizon that has chroma too high for Fluventic Sulfaquepts. Other properties are same as Fluventic Sulfaquepts. (Ex. Gimhae series) 13. Anthroaquic Fluvaquentic Eutrochrepts : These soils have mottles of low chroma in more than 50cm of the surface due to irrigated water. The base saturation is 60 percent or more in some subhroizon that is between depth of 25 and 75cm below the surface. (Ex. Jangyu, Chilgog series) 14. Anthroaquic Dystric Fluventic Eutrochrepts : These soils are similar to Anthroaquic Fluvaquentic Eutrochrepts except for the low chroma within 50cm of the surface. (Ex. Weolgog, Gyeongsan series) 15. Anthroaquic Fluventic Dystrochrepts : These soils have mottles that have chroma of 2 or less within 50cm of the soil surface due to artificial irrigation. They have lower base saturation (<60 percert) in all subhorizons between depths of 25 and 75cm below the soil surface. (Ex. Gocheon, Bigog series) 16. Anthro aquic Eutrandepts : These soils are similar to Anthroaquic Dystric Fluventic Eutrochrepts except for lower bulk density in the horizon. (Ex. Daejeong series) 17. Anthroaquic Hapludalfs : These soils' have a surface that is saturated with irrigated water at some time and have chroma of 2 or less in the matrix and higher chroma of mottles within 50cm of the surface. (Ex. Hwadong, Yongsu series) 18. Anthro aquic, Aquic Hapludalfs : These soils are similar to Anthro aquic Hapludalfs except for the matrix that has chroma 2 or less and higher chroma of mottles in more than 50cm of the surface. (Ex. Geugrag, Deogpyeong se ries)

  • PDF

An experimental study on the impact of an agreement on the means to achieve nursing goals in the early postpartum period of primiparous mothers and enhance their self-confidence and satisfaction in maternal role performance (산욕초기 초산모의 간호목표달성방번 합의가 어머니 역할수행에 대한 자신감 및 만족도에 미치는 영향에 관한 실험적 연구)

  • 이영은
    • Journal of Korean Academy of Nursing
    • /
    • v.22 no.1
    • /
    • pp.81-115
    • /
    • 1992
  • The problem addressed by this study was to determine the effect of nurse - patient agreement on the means to achieve nursing goals in the early postpartum period of primiparous mothers. It was hypothesized that the experimental treatment would result in hegher self-confidence and satisfaction in maternal role performance. This purpose was to contribute to the planning of nursing care to enhance self- confidence and satisfaction in maternal role performance and to the development of relevant nursing theory. Especially, the early postpartum period is crucial toward in recovery from childbirth and attainment of the maternal role. Maternal role attaintment is a complex social and cognitive process of stimulus -response accomplished by learning. Most women attain the maternal role sucessfully. But, some primiparous mothers experience difficultites in attainment of the maternal role due to lack of experience and knowledge. Self-confidence and satisfaction in maternal role performance are important factors in attainment and adjustment to the maternal role (Mercer, 1981a, 1981b ; Lederman, Weigarten, and Lederman, 1981 :Bobak and Jensen, 1985). Nursing is defined as behaviors of nurses add patients that attain nursing goals through action, reaction, interaction, and transaction. For attainment of nursing goals, active participating transactions must occur by agreement on the means to achieve those goals through nurse -patient mutual goal setting and establishment of their active relationships(King, 1981, Ha, 1977). Based on King's theory of goal attainment (1981), this stuy was planned as a non-equivalent control group, non -synchronized quasi -experimental design using agreement on the means to achieve nursing goals in early postpartum as the experimental treatment. The data were collected from July 20 to Sep. 1, 1991 by questionnaires with 60 primiparous mothers planing to breast feed after normal deliveries at W hospital in Pusan, Korea. The subjects were divided into a control group(conventional group) -those admitted from July 20 to Aug. 12, and an experimental group(agreement group) - those admitted from Aug. 13 to Sep. 1. The instument for agreement on the means to nursing goals in the early postpartum period included five steps - identification of disturbances of problems through action, reaction, and interaction with primiparous mothers : mutual early postpartal nursing goal setting : exploration of the means to achieve goals ; agreement on the means (self- care, ealry maternal -infant contact, performance of mothering behavior, and communicating about the infant's behavior and health condition) : implementation of the means. This instrument was developed on the basis of King's elements that lead to transactions in nurse-patient interactions. Lederman et al's (1981) scale for Confidence in ability to cope with tasks of motherhood and Lederman et al's(1981) scale for Mother's satisfaction with motherhood and infant care were used to measure self-confidence and satisfaction in maternal role performance ·with the subjects immediately after admission and on the day of discharge. Self-care performance in the experimental group was measured by self -evaluation tool developed by the investigator from the literature concerned. The tools to measure Pelf-confidence and satisfaction in maternal role performance, and the tool to measure self-evaluation of self-care performance were tested for internal reliability. Cronbach's Alphas were 0.94, 0.94, and 0.63. The data were analysed by using in S.P.S.S. computerized program and included percentage, x²-test, t-test, ANOVA, and Pearson Correlation Coefficient. The conclusions obtained from this study are summerized as follows : 1. The degree of self-confidence in maternal role performance of the total subjects group measured before the experimental treatment was above average with a mean score of 2.77(range 2.14-3.64). Out of 14 items, those with relatively high mean scores were ‘I would like to be a better mother than I am’(3.95), and ‘I have my doubts about whether I am a good mother’(2.87). Those with low mean scores were ‘I know that my baby wants most of the times’(2.28), ‘When the baby cries, I can tell what she /he wants’(2.37), and ‘I have confidence in my ability to care for the baby’(2;50). That is, the self - confidence of Primiparous mothers was considerably high in mothering, but rather low in activities concerning the infant care and understanding of the infant behavior. The degree of satisfaction in maternal role performance of the total subjects group measured before the experimental treatment was high with a mean score of 3.18(range 1.92-3.92). Out of 13 items, those with relatively high mean scores were ‘I am glad 1 had this baby now’(3.75), ‘I play with the baby between feedings when s/he is awake and quiet’(3.67), and ‘I enjoy being a mother’(3.27). Those with low mean scores were ‘I am upset about having too many responsibilities as a mother’(2.78), ‘It bothers me to get up for the baby at night’(2.82), and ‘I get annoyed if the baby frequently interrupts my activities’.(2.82), That is, the satisfaction of primiparous mothers was considerably high in mothering and infant care, but rather low in restraints in time or on the mother's self accomplishment and development. 2. Agreement on the means to achieve nursing goals in the early postpartum period included process of mutual goal setting, exploration of the means to achieve goals, and ahreement in concert means to achieve goals based on the mothers' condition, concerns, self-perception of the nurse - patient interactions. In the process of agreement, there was agreement that the means to achieve goals should be through trust and establishment of active relationships with the nurse through identification of problems according to planned nursing goals and active interaction, such as explanations, teaching, changing of opinions, acceptance or rejection of explanations, and proposing of questions. Therefore agreement on the means to achieve nursing goals in the early postpartum period appears to be an effective nursing intervention for primiparous mothers. 3. The degree of self- confidence in maternal role performance of the exprimental group was higher than that of the control group(t=3.95, p<0.01). Out of 14 items, those with higher score in the experimental group were ‘I would like to be a better mother than I am’(t=1.93, p<0.05), ‘I know that my baby wants most of the times’(t=2.75, p<0.01), ‘When the baby cries, 1 can tell what she/he wants’(t=2.10, p<0.05), ‘I have confidence in my ability to care for the baby’(t=3.72, p<0.01), ‘I trust my own judement in deciding how to care for the baby’(t=1.96, p<0.05), ‘I feel that I know my baby and what to do for him /her’(t=2.44, p<0.01), ‘I am concerned about being able to meet the baby's needs’(t=2.87, p<0.01), ‘I know what my baby likes and dislikes’(t=3.26, p<0.01), ‘I don't know to care for the baby as well as I should’(t=2.07, p<0.05), and ‘I am unsure about whether I give enough attention to the baby’(t=3.04, p<0.01), That is, the degree of self-confidence in mothering, activities concerning infant care, and understanding of infant behavior of the experimental group was higher than that of the control group. Therefore, the first hypothesis, that the degree of self-confidence in maternal role performance of the experimental group would be higher than that of the control group, was supported(t=3.95, p<0.01). 4. The degree of satisfaction in the maternal role performance of the exprimental group was higer than that or the control group(t=2.31, p<0.05). Out of 13 items, those with higher score in the experimental group were ‘I am glad I had this baby now’(t=2.29, p<0.05), ‘I enjoy taking care of the baby’(t=2.4g, p<0.01), ‘It is boring for me to care for the baby and do the same thing over and over’(t=2.87, P<0.01), ‘I am unhappy with the amount of time I have for activities other than childcare’(t=2.51, p<0.01), and ‘When bathing and diapering the baby, I would like to be doing something else’(t=2.43, p<0.01). That is, the degree of satisfaction in mothering, infant care, and restraints in time of on the mother's self accomplishment and development in the experimental group was higher than that of the control group. Therefore, the second hypothesis, that the degree of satisfaction in maternal role performance of the experimental group would be higher than that of the control group, was supported(t=2.31, p<0.05). 5. The third hypothesis, that the higher the degree of satisfaction in materenal role performance, the higher the degree of self-confidence in materenal role performance in the experimental group, was supported (r=0.57, p<0.01)

  • PDF

Radioimmunoassay Reagent Survey and Evaluation (검사별 radioimmunoassay시약 조사 및 비교실험)

  • Kim, Ji-Na;An, Jae-seok;Jeon, Young-woo;Yoon, Sang-hyuk;Kim, Yoon-cheol
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.25 no.1
    • /
    • pp.34-40
    • /
    • 2021
  • Purpose If a new test is introduced or reagents are changed in the laboratory of a medical institution, the characteristics of the test should be analyzed according to the procedure and the assessment of reagents should be made. However, several necessary conditions must be met to perform all required comparative evaluations, first enough samples should be prepared for each test, and secondly, various reagents applicable to the comparative evaluations must be supplied. Even if enough comparative evaluations have been done, there is a limit to the fact that the data variation for the new reagent represents the overall patient data variation, The fact puts a burden on the laboratory to the change the reagent. Due to these various difficulties, reagent changes in the laboratory are limited. In order to introduce a competitive bid, the institute conducted a full investigation of Radioimmunoassay(RIA) reagents for each test and established the range of reagents available in the laboratory through comparative evaluations. We wanted to share this process. Materials and Methods There are 20 items of tests conducted in our laboratory except for consignment tests. For each test, RIA reagents that can be used were fully investigated with the reference to external quality control report. and the manuals for each reagent were obtained. Each reagent was checked for the manual to check the test method, Incubation time, sample volume needed for the test. After that, the primary selection was made according to whether it was available in this laboratory. The primary selected reagents were supplied with 2kits based on 100tests, and the data correlation test, sensitivity measurement, recovery rate measurement, and dilution test were conducted. The secondary selection was performed according to the results of the comparative evaluation. The reagents that passed the primary and secondary selections were submitted to the competitive bidding list. In the case of reagent is designated as a singular, we submitted a explanatory statement with the data obtained during the primary and secondary selection processes. Results Excluded from the primary selection was the case where TAT was expected to be delayed at the moment, and it was impossible to apply to our equipment due to the large volume of reagents used during the test. In the primary selection, there were five items which only one reagent was available.(squamous cell carcinoma Ag(SCC Ag), β-human chorionic gonadotropin(β-HCG), vitamin B12, folate, free testosterone), two reagents were available(CA19-9, CA125, CA72-4, ferritin, thyroglobulin antibody(TG Ab), microsomal antibody(Mic Ab), thyroid stimulating hormone-receptor-antibody(TSH-R-Ab), calcitonin), three reagents were available (triiodothyronine(T3), Tree T3, Free T4, TSH, intact parathyroid hormone(intact PTH)) and four reagents were available are carcinoembryonic antigen(CEA), TG. In the secondary selection, there were eight items which only one reagent was available.(ferritin, TG, CA19-9, SCC, β-HCG, vitaminB12, folate, free testosterone), two reagents were available(TG Ab, Mic Ab, TSH-R-Ab, CA125, CA72-4, intact PTH, calcitonin), three reagents were available(T3, Tree T3, Free T4, TSH, CEA). Reasons excluded from the secondary selection were the lack of reagent supply for comparative evaluations, the problems with data reproducibility, and the inability to accept data variations. The most problematic part of comparative evaluations was sample collection. It didn't matter if the number of samples requested was large and the capacity needed for the test was small. It was difficult to collect various concentration samples in the case of a small number of tests(100 cases per month or less), and it was difficult to conduct a recovery rate test in the case of a relatively large volume of samples required for a single test(more than 100 uL). In addition, the lack of dilution solution or standard zero material for sensitivity measurement or dilution tests was one of the problems. Conclusion Comparative evaluation for changing test reagents require appropriate preparation time to collect diverse and sufficient samples. In addition, setting the total sample volume and reagent volume range required for comparative evaluations, depending on the sample volume and reagent volume required for one test, will reduce the burden of sample collection and planning for each comparative evaluation.

Role, Change, Job Satisfaction and Obstacles in Carrying out the Role of Public Health Nurses in Health Center (보건소 보건간호사의 역할변화, 역할수행의 장애요인과 만족도)

  • Ahn, Kyeong-Sook;Jung, Moon-Sook
    • Journal of agricultural medicine and community health
    • /
    • v.20 no.1
    • /
    • pp.1-13
    • /
    • 1995
  • Based on the questionnaires sent to 270 nurses of public health centers in kyungnam during the period of March 19 to April 11 in 1992, this study was written for the of finding out the grade of satisfaction, obstacles in carrying out duties concerned with nursing services and the change of nurses role needed according to the change of the local public health administration. The first-ranking tasks carried by nurses of public health center are believed to have been family planning activities before the 1970's, nursing services during the 1970's, mother-child health activities during the 1980's, and nursing services during the period of 1990 to 1992. As far as the priority order of all the family planning activities is concerned, the counseling of the insertion of intrauterine contraceptive device, the use of oral pill or the distribution of condom was placed emphasis on before 1970, and publicity activities of family planning after that time. The first priority order of mother-child health activities has been put on the registration of pregnant women since 1970, with prenatal examination and vaccination ranking next to it. The priority order for activities against tuberculosis was laid on finding out and registration of new T.B. patients every year, with patients' control, and medication or injection ranking next to it. As for the priority order of nursing services, traveling medical examination and treatment ranked the first-stressed activity before 1970, with medication and injection ranking next to it. The first priority order management activity of communicable diseases was put on vaccination before 1970, with medication and injection. ranking next. And consultation and education ranked second to it during 1990 to 1992. As for the health services of the aged, traveling examination and treatment ranked the order, with the assistance of medical examination ranking next to it. As far as troubles and obstacles shown in case of family planning, the rate of residents' lack understanding was 28.8%, that of lacking budget 13.6%, and the imperfection of public health administration system 11.9%. In the case of tuberculosis control, residents' lacking understanding was 32.5%, the deficiency of public health administration system 18.2%, over-duty(shortage of hands) 15.6%, and the insufficiency skill and know-how 13.0%. In the case of nursing services, the deficiency of public health administration system was 18.2%, each over-duty(the shortage of hands) and the shortage of facilities and equipment 15.6% respective, and residents' lacking understanding 13.0%. The rate of dissatisfaction with the chance or possibility of promotion for his or her career or capability was shown to be 49.2%, and 65.9% of the health nurses expressed their complaints of the deficiency of the chance of the promotion to a professional or expert. when the public health nurses were asked in the questionably whether they were satisfied or not with current state of equipment and facilities needed for public health service, 49.6% of them answered in the negative. The grade of the satisfaction with the current individual position was shown to be low as much as the status of his or her position was now. 37.6% of those asked in the research answered to have the readiness to switch jobs for the reasons of dissatisfaction and so on with lacking promotion chance as well as bad working condition. Significant correlation between the grade of job satisfaction and the current status of the po as found to be in this research, which showed that the lower the status of position was, the lower the grade of job satisfaction was. But little correlation between the grade of job satisfaction and his or her schooling and career was found. In order to carry out primary health care successfully, it can be said that more education and publicity activities to make public health nurses and residents see it in a new light are requested. In addition to it, it is suggested that the improvement of promotion system for public health nurses and the enlargement of job province should also be taken in consideration of the high dissatisfaction with and complaints of the chance of promotion and the system of position. In order words, it is important that considerations for system improvement enough to make nursing services pleasant and satisfactory should be taken into.

  • PDF

Sensory Information Processing

  • Yoshimoto, Chiyoshi
    • Journal of Biomedical Engineering Research
    • /
    • v.6 no.2
    • /
    • pp.1-8
    • /
    • 1985
  • The wall shear stress in the vicinity of end-to end anastomoses under steady flow conditions was measured using a flush-mounted hot-film anemometer(FMHFA) probe. The experimental measurements were in good agreement with numerical results except in flow with low Reynolds numbers. The wall shear stress increased proximal to the anastomosis in flow from the Penrose tubing (simulating an artery) to the PTFE: graft. In flow from the PTFE graft to the Penrose tubing, low wall shear stress was observed distal to the anastomosis. Abnormal distributions of wall shear stress in the vicinity of the anastomosis, resulting from the compliance mismatch between the graft and the host artery, might be an important factor of ANFH formation and the graft failure. The present study suggests a correlation between regions of the low wall shear stress and the development of anastomotic neointimal fibrous hyperplasia(ANPH) in end-to-end anastomoses. 30523 T00401030523 ^x Air pressure decay(APD) rate and ultrafiltration rate(UFR) tests were performed on new and saline rinsed dialyzers as well as those roused in patients several times. C-DAK 4000 (Cordis Dow) and CF IS-11 (Baxter Travenol) reused dialyzers obtained from the dialysis clinic were used in the present study. The new dialyzers exhibited a relatively flat APD, whereas saline rinsed and reused dialyzers showed considerable amount of decay. C-DAH dialyzers had a larger APD(11.70$\pm$1.32mmHg/min)compared to CF dialyzers(4.32$\pm$0.55mmHg/min)(p<0.05). However, there was no observable difference in the UFR between the two dialyzers. Neither APD nor UFR showed any significant increase with an increasing number of reuses for up to more than 20reuses. A substantial number of failures observed in APD(larger than 20mmHe/min)on the reused dialyzers(2 out of 40 CP and S out 26 C-DAK) were attributed to the Possible damage on the fibers. The CF 15-11 HFDs which failed APD test did not show changes in the UFR compared to normal dialyzers indicating that APD is a more sensitive test than UFR test to evaluate the integrity of the fibers. 30527 T00401030527 ^x For quantitative measurement of reflected light from a clinical diagnostic strip, a prototype old reflectance photometer was designed. The strip loader and cassette were made to obtain more accurate reflectance parameters. The strip was illuminated at 45˚c through optical fiber and the intensity of reflected light was determined at rectanguLat angle using a photodiode. The kubelka-munk coefficient and reflection optical density were determined ar four different wavelengths(500, 550, 570 and 610nm) for blood glucose strip. For higher concentration than 300mg/41 about glucose, a saturation state of abforbance was observed at 500, 550 and 570nm. The correlation between glucose concentration and parameters was the best at 610nm. 30535 T00401030535 ^x Radiation-induced fibrosarcoma tumors were grown on the flanks of C3H mice. The mice were divided into two groups. One group was injected with Photofrin II, intravenously (2.5mg/kg body weight). The other group received no Photofrin II. Mice from both groups were irradialed for approximately 15 minutes at 100, 300, or 500 mW/cm2 with the argon (488nm/514.5 nm), dye(628nm) and gold vapor (pulsed 628 nm) laser light. A photosensitizer behaved as an added absorber. Under our experimental conditions, the presence of Photolfrin II increased surface temperature by at least 40% and the temperature rise due to 300 mW/cm2 irradiation exceeded values for hyperthermia. Light and temperature distributions with depth were estimated by a computer model. The model demonstrated the influence of wavelength on the thermal process and proved to be a valuable tool to investigate internal temperature rise. 30536 T00401030536 ^x We investigated the structural geometry of thirty-eight Korean femurs. The purpose of this study is to identify major geometrical differences between Korean femurs 3nd others that we believe belong to Caucasians so that we would be able to get insights into the femoral component design that fits Asians including Koreans. We utilized computerized tomography (CT) images of femurs extracted from cadavers. The CT images were transformed into bitmap data by using a film scanner, and then analyzed by using a commercially available software called Image v.1.0 and a Macintosh IIci computer.The resulting data were compared with already published data. The major results show that the geometry of the Korean femurs is significantly different from that of Caucasians: (1) the anteversion angle and the canal flare index are greater by the amount of approximately 8˚ and 0.5, respectively, (2) the shape of the isthmus cross section is more round, and (3) the distance between the teaser trochanter and the proximal border of the isthmus is shelter by about 15 mm. The results suggested that the femoral component suitable for Asians should be different from the currently-used components designed and manufactured mostly by European or American companies. 30537 T00401030537 ^x It is well known that nonlinear propagation characteristics of the wave in the tissue may give very useful information for the medical diagnoisis. In this paper, a new method to detect nonlinear propagation characteristics of the internal vibration in the tissue for the low frequency mechanical vibration by using bispectral analysis is proposed. In the method, low frequency vibration of f0( = 100Hz) is applied on the surface of the object, and the waveform of the internal vibration x (t) is measured from Doppler frequency modulation of silmultaneously transmitted probing ultrasonic waves. Then, the bispectra of the signal x (t) at the frequencies (f0, f0) and (f0, 2f0) are calculated to estimate the nonlinear propagation characteristics as their magnitude ratio, w here since bispectrum is free from the gaussian additive noise we can get the value with high S/N. Basic experimental system is constructed by using 3.0 MHz probing ultrasonic waves and the several experiments are carried out for some phantoms. Results show the superiority of the proposed method to the conventional method using power spectrum and also its usefulness for the tissue characterization. 30541 T00401030541 ^x This paper describes the implementation of a computerized radial pulse diagnosis by aids of a clinical expert. On this base, we composed of the radial pulse diagnosis system in korean traditional medicine. The system composed of a radial pulse wave detection system and a radial pulse diagnosis system. With a detection system, we detected Inyoung and Cheongu radial pulse wave and processed it. Then, we have got the characteristic parameters of radial pulse wave and also quantified that according to the method of Inyoung-Cheongu Comparison Radial Pulse Diagnosis. We defined the jugement standard of radial pulse diagnosis system and then we confirmed the possibility for realization of automatic radial pulse diagnosis in korean traditional medicine. 30545 T00401030545 ^x Microspheres are expected to be applied to biomedical areas such as solid-phase immunoassays, drug delivery systems, immunomagnetic cell separation. To synthesize microspheres for biomedical application, "two stage shot growth method" was developed. The uniformity ratio of synthesized microspheres was always smaller than 1.05. And the surface charge density (or the number of ionizable functional groups) of the microspheres synthesized by "two stage shot growth method" was 6~13 times higher than that of the microspheres synthesized by conventional seeded batch copolymerization. As a previous step for biomedical application, adsorption experiments of bovine albumin on microspheres were carried out under various conditions. The maximum adsorbed amount was obtained in the neighborhood of pH 4.5. Isoelectric point of bovine albumin is pH 5.0, so experimental result shows that it shifted to acid area. The adsorption isotherm was obtained, the plateau region was always reached at 2.Og/L (bulk concentration of bovine albumin).The effect of the kind and the amount of surface functional group was also examined. 30575 T00401030575 ^x A medical image workstation was developed using multimedia technique. The system based on PC-486DX was designed to acquire medical images produced by medical imaging instruments and related audio information, that is, doctors' reporting results. Input information was processed and analyzed, then the results were presented in the form of graph and animation. All the informations of the system were hierarchically related with the image as the apex. Processing and analysis algorithms were implemented so that the diagnostic accuracy could be improved. The diagnosed information can be transferred for patient diagnosis through LAN(local area network). 30592 T00401030592 ^x In the conventional infrared imaging system, complex infrared lens systems are usually used for directing collimated narrow infrared beams into the high speed 2-dimensional optic scanner. In this paper, a simple reflective infrared optic system with a 2-dimensional optic scanner is proposed for the realization of medical infrared thermography system. It has been experimentally proven that the intfrared thermography system composed of the proposed optic system has the temperature resolution of 0.1˚c under the spatial resolution of lmrad, the image matrix size of 256 X 240, and tile imaging time of 4 seconds. 30593 T00401030593 ^x In this paper, MIIS (Medical Image Information System) has been designed and implemented using INGRES RDBMS, which is based on a client/server architecture. The implemented system allows users to register and retrieve patient information, medical images and diagnostic reports. It also provides the function to display these information on workstation windows simultaneously by using the designed menu-driven graphic user interface. The medical image compression/decompression techniques are implemented and integrated into the medical image database system for the efficient data storage and the fast access through the network. 30594 T00401030594 ^x In this paper, computerized BEAM was implemented for the space domain analysis of EEG. Trans-formation from temporal summation to two-dimensional mappings is formed by 4 nearest point inter-polaton method. Methods of representation of BEAM are two. One is dot density method which classify brain electrical potential 9 levels by dot density of gray levels and the other is colour method which classify brain electrical 12 levels by red-green colours. In this BEAM, instantaneous change and average energy distribution over any arbitrary time interval of brain electrical activity could be observed and analyzed easily. In the frequency domain, the distribution of energy spectrum of a special band can easily be distinguished normality and abnormality. 30608 T00401030608 ^x Laboratory information system (LIS) is a key tool to manage laboratory data in clinical pathology. Our department has developed an information system for routine hematology using down-sized computer system. We have used an IBM 486 compatible PC with 16MB main memory, 210 MB hard disk drive, 9 RS-232C port and 24 pin dot printer. The operating system and database management system were SCO UNIX and SCO foxbase, respectively. For program development, we used Xbase language provided by SCO foxbase. The C language was used for interface purpose. To make the system use friendly, pull-down menu was used. The system connected to our hospital information system via application program interface (API), so the information related to patient and request details is automatically transmitted to our computer. Our system interfaced with fwd complete blood count analyzers(Sysmex NE-8000 and Coulter STKS) for unidirectional data tansmission from analyzer to computer. The authors suggests that this system based on down-sized computer could provide a progressive approach to total LIS based on local area network, and the implemented system could serve as a model for other hospital's LIS for routine hematology. 30609 T00401030609 ^x To develop an artificial bone substitute that is gradually degraded and replaced by the regenerated natural bone, the authors designed a composite that is consisted of calcium phosphate and collagen. To use as the structural matrix of the composite, collagen was purified from human umbilical cord. The obtained collagen was treated by pepsin to remove telopeptides, and finally, the immune-free atelocollagen was produced: The cross linked atelocollagen was highly resistant to the collagenase induced collagenolysis. The cross linked collagen demonstrated an improved tensile strength. 30618 T00401030618 ^x This paper is a study on the design of adptive filter for QRS complex detection. We propose a simple adaptive algorithm to increase capability of noise cancelation in QRS complex detection with two stage adaptive filter. At the first stage, background noise is removed and at the next stage, only spectrum of QRS complex components is passed. Two adaptive filters can afford to keep track of the changes of both noise and QRS complex. Each adaptive filter consists of prediction error filter and FIR filter The impulse response of FIR filter uses coefficients of prediction error filter. The detection rates for 105 and 108 of MIT/BIH data base were 99.3% and 97.4% respectively. 30619 T00401030619 ^x To develop an artificial bone substitute that is gradually degraded and replaced by the regenerated natural bone, the authors designed and produced a composite that is consisted of calcium phosphate and collagen. Human umbilical cord origin pepsin treated type I atelocollagen was used as the structural matrix, by which sintered or non-sintered carbonate apatite was encapsulated to form an inorganic-organic composite. With cross linking atelocollagen by UV ray irradiation, the resistance to both compressive and tensile strength was increased. Collagen degradation by the collagenase induced collagenolysis was also decreased. 30620 T00401030620 ^x We have developed a monoleaflet polymer valve as an inexpensive and viable alternative, especially for short-term use in the ventricular assist device or total artificial heart. The frame and leaflet of the polymer valve were made from polyurethane, To evaluate the hemodynamic performance of the polymer valve a comparative study of flow dynamics past a polymer valve and a St. Jude Medical prosthetic valve under physiological pulsatile flow conditions in vitro was made. Comparisons between the valves were made on the transvalvular pressure drop, regurgitation volume and maximum valve opening area. The polymer valve showed smaller regurgitation volume and transvalvular pressure drop compared to the mechanical valve at higher heart rate. The results showed that the functional characteristics of the polymer valve compared favorably with those of the mechanical valve at higher heart rate. 30621 T00401030621 ^x Explosive evaporative removal process of biological tissue by absorption of a CW laser has been simulated by using gelatin and a multimode Nd:YAG laser. Because the point of maximun temperature of laser-irradiated gelatin exists below the surface due to surface cooling, evaporation at the boiling temperature is made explosively from below the surface. The important parameters of this process are the conduction loss to laser power absorption (defined as the conduction-to-laser power parameter, Nk), the convection heat transfer at the surface to conduction loss (defined as Bi), dimensionless extinction coefficient (defined as Br.), and dimensionless irradiation time (defined as Fo). Dependence of Fo on Nk and Bi has been observed by experiment, and the results have been compared with the numerical results obtained by solving a 2-dimensional conduction equation. Fo and explosion depth (from the surface to the point of maximun temperature) are increased when Nk and Bi are increased.To find out the minimum laser power for explosive evaporative removal process, steady state analysis has been also made. The limit of Nk to induce evaporative removal, which is proportional to the inverse of the laser power, has been obtained. 30622 T00401030622 ^x N1 and N2 gross neural action potentials were measured from the round window of the guinea pig cochlea at the onset of the acoustic stimuli. N1-N2 audiograms were made by means of regulating stimulant intensities in order to produce constant N1-N2 potentials as criteria for different input tone pip frequencies. The lowest threshold was measured with an input tone pip I5 dB SPL in intensity and 12 KHz in frequency when the animal was in normal physiological condition. The procedure of experimental measurements is explained in detail. This experimental approach is very useful for the investigation of the Cochlear function. Both noN1inear and active functions of the Cochlea can be monitored by N1-N2 audiograms. 30623 T00401030623 ^x In electrical impedance tomography(EIT), we use boundary current and voltage measurements toprovide the information about the cross-sectional distribution of electrical impedance or resistivity. One of the major problems in EIT has been the inaccessibility of internal voltage or current data in finding the internal impedance values. We propose a new image reconstruction method using internal current density data measured by NMR. We obtained a two-dimensional current density distribution within a phantom by processing the real and imaginary MR images from a 4.77 NMR machine. We implemented a resistivity mage reconstruction algorithm using the finite element method and sensitivity matrix. We presented computer simulation results of the mage reconstruction algorithm and furture direction of the research. 30624 T00401030624 ^x A new method of digital image analysis technique for discrimination of cancer cell was presented in this paper. The object image was the Thyroid eland cells image that was diagnosed as normal and abnormal (two types of abnormal: follicular neoplastic cell, and papillary neoplastic cell), respectively. By using the proposed region segmentation algorithm, the cells were segmented into nucleus. The 16 feature parameters were used to calculate the features of each nucleus. A9 a consequence of using dominant feature parameters method proposed in this paper, discrimination rate of 91.11% was obtained for Thyroid Gland cells. 30625 T00401030625 ^x An electrical stimulator was designed to induce locomotion for paraplegic patients caused by central nervous system injury. Optimal stimulus parameters, which can minimize muscle fatigue and can achieve effective muscle contraction were determined in slow and fast muscles in Sprague-Dawley rats. Stimulus patterns of our stimulator were designed to simulate electromyographic activity monitored during locomotion of normal subjects. Muscle types of the lower extremity were classified according to their mechanical property of contraction, which are slow muscle (msoleus m.) and fast muscle (medial gastrocneminus m., rectus femoris m., vastus lateralis m.). Optimal parameters of electrical stimulation for slow muscles were 20 Hz, 0.2 ms square pulse. For fast muscle, 40 Hz, 0.3 ms square pulse was optimal to produce repeated contraction. Higher stimulus intensity was required when synergistic muscles were stimulated simultaneously than when they were stimulated individually. Electrical stimulation for each muscle was designed to generate bipedal locomotion, so that individual muscles alternate contraction and relaxation to simulate stance and swing phases. Portable electrical stimulator with 16 channels built in microprocessor was constructed and applied to paraplegic patients due to lumbar cord injury. The electrical stimulator restored partially gait function in paraplegic patients. 30626 T00401030626 ^x Two-Dimensional modelling of the Cochlear biomechanics is presented in this paper. The Laplace partial differential equation which represents the fluid mechanics of the Cochlea has been transformed into two-dimensional electrical transmission line. The procedure of this transformation is explained in detail. The comparison between one and two dimensional models is also presented. This electrical modelling of the basilar membrane (BM) is clearly useful for the next approach to the further. Development of active elements which are essential in the producing of the sharp tuning of the BM. This paper shows that two-dimension model is qualitatively better than one-dimensional model both in amplitude and phase responses of the BM displacement. The present model is only for frequency response. However because the model is electrical, the two-dimensional transmission line model can be extended to time response without any difficult. 30627 T00401030627 ^x A method has been proposed for the fully automatic detection of left ventricular endocardial boundary in 2D short axis echocardiogram using geometric model. The procedure has the following three distinct stages. First, the initial center is estimated by the initial center estimation algorithm which is applied to decimated image. Second, the center estimation algorithm is applied to original image and then best-fit elliptic model estimation is processed. Third, best-fit boundary is detected by the cost function which is based on the best-fit elliptic model. The proposed method shows effective result without manual intervention by a human operator. 30628 T00401030628 ^x The intelligent trajectory control method that controls moving direction and average velocity for a prosthetic arm is proposed by pattern recognition and force estimations using EMG signals. Also, we propose the real time trajectory planning method which generates continuous accelleration paths using 3 stage linear filters to minimize the impact to human body induced by arm motions and to reduce the muscle fatigue. We use combination of MLP and fuzzy filter for pattern recognition to estimate the direction of a muscle and Hogan's method for the force estimation. EMG signals are acquired by using a amputation simulator and 2 dimensional joystick motion. The simulation results of proposed prosthetic arm control system using the EMf signals show that the arm is effectively followed the desired trajectory depended on estimated force and direction of muscle movements. 30638 T00401030638 ^x A new neural network architecture for the recognition of patterns from images is proposed, which is partially based on the results of physiological studies. The proposed network is composed of multi-layers and the nerve cells in each layer are connected by spatial filters which approximate receptive fields in optic nerve fields. In the proposed method, patterns recognition for complicated images is carried out using global features as well as local features such as lines and end-points. A new generating method of matched filers representing global features is proposed in this network. 30659 T00401030659 ^x An implementation scheme of the magnetic nerve stimulator using a switching mode power supply is proposed. By using a switching mode power supply rather than a conventional linear power supply for charging high voltage capacitors, the weight and size of the magnetic nerve stimulator can be considerably reduced. Maximum output voltage of the developed magnetic nerve stimulator using the switching mode power supply is 3, 000 volts and switching time is about 100 msec. Experimental results or human nerve stimulations using the developed stimulator are presented. 30768 T00401030768 ^x In this paper, we describe the design methodology and specifications of the developed module-based bedside monitors for patient monitoring. The bedside monitor consists of a main unit and module cases with various parameter modules. The main unit includes a 12.1" TFT color LCD, a main CPU board, and peripherals such as a module controller, Ethernet LAN card, video card, rotate/push button controller, etc. The main unit can connect at maximum three module cases each of which can accommodate up to 7 parameter modules. They include the modules for electrocardiograph, respiration, invasive blood pressure, noninvasive blood pressure, temperature, and SpO2 with Plethysmograph.SpO2 with Plethysmograph.

  • PDF

High Resolution HC$_3$N Observations toward the Central Region of Sagittarius B2

  • H.S-Ching;Oh, M.ishi;M.Morimoto
    • Bulletin of the Korean Space Science Society
    • /
    • 1993.10a
    • /
    • pp.17-17
    • /
    • 1993
  • The wall shear stress in the vicinity of end-to end anastomoses under steady flow conditions was measured using a flush-mounted hot-film anemometer(FMHFA) probe. The experimental measurements were in good agreement with numerical results except in flow with low Reynolds numbers. The wall shear stress increased proximal to the anastomosis in flow from the Penrose tubing (simulating an artery) to the PTFE: graft. In flow from the PTFE graft to the Penrose tubing, low wall shear stress was observed distal to the anastomosis. Abnormal distributions of wall shear stress in the vicinity of the anastomosis, resulting from the compliance mismatch between the graft and the host artery, might be an important factor of ANFH formation and the graft failure. The present study suggests a correlation between regions of the low wall shear stress and the development of anastomotic neointimal fibrous hyperplasia(ANPH) in end-to-end anastomoses. 30523 T00401030523 ^x Air pressure decay(APD) rate and ultrafiltration rate(UFR) tests were performed on new and saline rinsed dialyzers as well as those roused in patients several times. C-DAK 4000 (Cordis Dow) and CF IS-11 (Baxter Travenol) reused dialyzers obtained from the dialysis clinic were used in the present study. The new dialyzers exhibited a relatively flat APD, whereas saline rinsed and reused dialyzers showed considerable amount of decay. C-DAH dialyzers had a larger APD(11.70${\pm}$1.32mmHg/min)compared to CF dialyzers(4.32${\pm}$0.55mmHg/min)(p<0.05). However, there was no observable difference in the UFR between the two dialyzers. Neither APD nor UFR showed any significant increase with an increasing number of reuses for up to more than 20reuses. A substantial number of failures observed in APD(larger than 20mmHe/min)on the reused dialyzers(2 out of 40 CP and S out 26 C-DAK) were attributed to the Possible damage on the fibers. The CF 15-11 HFDs which failed APD test did not show changes in the UFR compared to normal dialyzers indicating that APD is a more sensitive test than UFR test to evaluate the integrity of the fibers. 30527 T00401030527 ^x For quantitative measurement of reflected light from a clinical diagnostic strip, a prototype old reflectance photometer was designed. The strip loader and cassette were made to obtain more accurate reflectance parameters. The strip was illuminated at 45˚c through optical fiber and the intensity of reflected light was determined at rectanguLat angle using a photodiode. The kubelka-munk coefficient and reflection optical density were determined ar four different wavelengths(500,550,570 and 610nm) for blood glucose strip. For higher concentration than 300mg/41 about glucose, a saturation state of abforbance was observed at 500,550 and 570nm. The correlation between glucose concentration and parameters was the best at 610nm. 30535 T00401030535 ^x Radiation-induced fibrosarcoma tumors were grown on the flanks of C3H mice. The mice were divided into two groups. One group was injected with Photofrin II, intravenously (2.5mg/kg body weight). The other group received no Photofrin II. Mice from both groups were irradialed for approximately 15 minutes at 100,300, or 500 mW/cm2 with the argon (488nm/514.5 nm), dye(628nm) and gold vapor (pulsed 628 nm) laser light. A photosensitizer behaved as an added absorber. Under our experimental conditions, the presence of Photolfrin II increased surface temperature by at least 40% and the temperature rise due to 300 mW/cm2 irradiation exceeded values for hyperthermia. Light and temperature distributions with depth were estimated by a computer model. The model demonstrated the influence of wavelength on the thermal process and proved to be a valuable tool to investigate internal temperature rise. 30536 T00401030536 ^x We investigated the structural geometry of thirty-eight Korean femurs. The purpose of this study is to identify major geometrical differences between Korean femurs 3nd others that we believe belong to Caucasians so that we would be able to get insights into the femoral component design that fits Asians including Koreans. We utilized computerized tomography (CT) images of femurs extracted from cadavers. The CT images were transformed into bitmap data by using a film scanner, and then analyzed by using a commercially available software called Image v.1.0 and a Macintosh IIci computer.The resulting data were compared with already published data. The major results show that the geometry of the Korean femurs is significantly different from that of Caucasians: (1) the anteversion angle and the canal flare index are greater by the amount of approximately 8˚ and 0.5, respectively, (2) the shape of the isthmus cross section is more round, and (3) the distance between the teaser trochanter and the proximal border of the isthmus is shelter by about 15 mm. The results suggested that the femoral component suitable for Asians should be different from the currently-used components designed and manufactured mostly by European or American companies. 30537 T00401030537 ^x It is well known that nonlinear propagation characteristics of the wave in the tissue may give very useful information for the medical diagnoisis. In this paper, a new method to detect nonlinear propagation characteristics of the internal vibration in the tissue for the low frequency mechanical vibration by using bispectral analysis is proposed. In the method, low frequency vibration of f0( = 100Hz) is applied on the surface of the object, and the waveform of the internal vibration x (t) is measured from Doppler frequency modulation of silmultaneously transmitted probing ultrasonic waves. Then, the bispectra of the signal x (t) at the frequencies (f0, f0) and (f0, 2f0) are calculated to estimate the nonlinear propagation characteristics as their magnitude ratio, w here since bispectrum is free from the gaussian additive noise we can get the value with high S/N. Basic experimental system is constructed by using 3.0 MHz probing ultrasonic waves and the several experiments are carried out for some phantoms. Results show the superiority of the proposed method to the conventional method using power spectrum and also its usefulness for the tissue characterization. 30541 T00401030541 ^x This paper describes the implementation of a computerized radial pulse diagnosis by aids of a clinical expert. On this base, we composed of the radial pulse diagnosis system in korean traditional medicine. The system composed of a radial pulse wave detection system and a radial pulse diagnosis system. With a detection system, we detected Inyoung and Cheongu radial pulse wave and processed it. Then, we have got the characteristic parameters of radial pulse wave and also quantified that according to the method of Inyoung-Cheongu Comparison Radial Pulse Diagnosis. We defined the jugement standard of radial pulse diagnosis system and then we confirmed the possibility for realization of automatic radial pulse diagnosis in korean traditional medicine. 30545 T00401030545 ^x Microspheres are expected to be applied to biomedical areas such as solid-phase immunoassays, drug delivery systems, immunomagnetic cell separation. To synthesize microspheres for biomedical application, "two stage shot growth method" was developed. The uniformity ratio of synthesized microspheres was always smaller than 1.05. And the surface charge density (or the number of ionizable functional groups) of the microspheres synthesized by "two stage shot growth method" was 6~13 times higher than that of the microspheres synthesized by conventional seeded batch copolymerization. As a previous step for biomedical application, adsorption experiments of bovine albumin on microspheres were carried out under various conditions. The maximum adsorbed amount was obtained in the neighborhood of pH 4.5. Isoelectric point of bovine albumin is pH 5.0, so experimental result shows that it shifted to acid area. The adsorption isotherm was obtained, the plateau region was always reached at 2.Og/L (bulk concentration of bovine albumin).The effect of the kind and the amount of surface functional group was also examined. 30575 T00401030575 ^x A medical image workstation was developed using multimedia technique. The system based on PC-486DX was designed to acquire medical images produced by medical imaging instruments and related audio information, that is, doctors' reporting results. Input information was processed and analyzed, then the results were presented in the form of graph and animation. All the informations of the system were hierarchically related with the image as the apex. Processing and analysis algorithms were implemented so that the diagnostic accuracy could be improved. The diagnosed information can be transferred for patient diagnosis through LAN(local area network). 30592 T00401030592 ^x In the conventional infrared imaging system, complex infrared lens systems are usually used for directing collimated narrow infrared beams into the high speed 2-dimensional optic scanner. In this paper, a simple reflective infrared optic system with a 2-dimensional optic scanner is proposed for the realization of medical infrared thermography system. It has been experimentally proven that the intfrared thermography system composed of the proposed optic system has the temperature resolution of 0.1˚c under the spatial resolution of lmrad, the image matrix size of 256 X 240, and tile imaging time of 4 seconds. 30593 T00401030593 ^x In this paper, MIIS (Medical Image Information System) has been designed and implemented using INGRES RDBMS, which is based on a client/server architecture. The implemented system allows users to register and retrieve patient information, medical images and diagnostic reports. It also provides the function to display these information on workstation windows simultaneously by using the designed menu-driven graphic user interface. The medical image compression/decompression techniques are implemented and integrated into the medical image database system for the efficient data storage and the fast access through the network. 30594 T00401030594 ^x In this paper, computerized BEAM was implemented for the space domain analysis of EEG. Trans-formation from temporal summation to two-dimensional mappings is formed by 4 nearest point inter-polaton method. Methods of representation of BEAM are two. One is dot density method which classify brain electrical potential 9 levels by dot density of gray levels and the other is colour method which classify brain electrical 12 levels by red-green colours. In this BEAM, instantaneous change and average energy distribution over any arbitrary time interval of brain electrical activity could be observed and analyzed easily. In the frequency domain, the distribution of energy spectrum of a special band can easily be distinguished normality and abnormality. 30608 T00401030608 ^x Laboratory information system (LIS) is a key tool to manage laboratory data in clinical pathology. Our department has developed an information system for routine hematology using down-sized computer system. We have used an IBM 486 compatible PC with 16MB main memory, 210 MB hard disk drive, 9 RS-232C port and 24 pin dot printer. The operating system and database management system were SCO UNIX and SCO foxbase, respectively. For program development, we used Xbase language provided by SCO foxbase. The C language was used for interface purpose. To make the system use friendly, pull-down menu was used. The system connected to our hospital information system via application program interface (API), so the information related to patient and request details is automatically transmitted to our computer. Our system interfaced with fwd complete blood count analyzers(Sysmex NE-8000 and Coulter STKS) for unidirectional data tansmission from analyzer to computer. The authors suggests that this system based on down-sized computer could provide a progressive approach to total LIS based on local area network, and the implemented system could serve as a model for other hospital's LIS for routine hematology. 30609 T00401030609 ^x To develop an artificial bone substitute that is gradually degraded and replaced by the regenerated natural bone, the authors designed a composite that is consisted of calcium phosphate and collagen. To use as the structural matrix of the composite, collagen was purified from human umbilical cord. The obtained collagen was treated by pepsin to remove telopeptides, and finally, the immune-free atelocollagen was produced: The cross linked atelocollagen was highly resistant to the collagenase induced collagenolysis. The cross linked collagen demonstrated an improved tensile strength. 30618 T00401030618 ^x This paper is a study on the design of adptive filter for QRS complex detection. We propose a simple adaptive algorithm to increase capability of noise cancelation in QRS complex detection with two stage adaptive filter. At the first stage, background noise is removed and at the next stage, only spectrum of QRS complex components is passed. Two adaptive filters can afford to keep track of the changes of both noise and QRS complex. Each adaptive filter consists of prediction error filter and FIR filter The impulse response of FIR filter uses coefficients of prediction error filter. The detection rates for 105 and 108 of MIT/BIH data base were 99.3% and 97.4% respectively. 30619 T00401030619 ^x To develop an artificial bone substitute that is gradually degraded and replaced by the regenerated natural bone, the authors designed and produced a composite that is consisted of calcium phosphate and collagen. Human umbilical cord origin pepsin treated type I atelocollagen was used as the structural matrix, by which sintered or non-sintered carbonate apatite was encapsulated to form an inorganic-organic composite. With cross linking atelocollagen by UV ray irradiation, the resistance to both compressive and tensile strength was increased. Collagen degradation by the collagenase induced collagenolysis was also decreased. 30620 T00401030620 ^x We have developed a monoleaflet polymer valve as an inexpensive and viable alternative, especially for short-term use in the ventricular assist device or total artificial heart. The frame and leaflet of the polymer valve were made from polyurethane, To evaluate the hemodynamic performance of the polymer valve a comparative study of flow dynamics past a polymer valve and a St. Jude Medical prosthetic valve under physiological pulsatile flow conditions in vitro was made. Comparisons between the valves were made on the transvalvular pressure drop, regurgitation volume and maximum valve opening area. The polymer valve showed smaller regurgitation volume and transvalvular pressure drop compared to the mechanical valve at higher heart rate. The results showed that the functional characteristics of the polymer valve compared favorably with those of the mechanical valve at higher heart rate. 30621 T00401030621 ^x Explosive evaporative removal process of biological tissue by absorption of a CW laser has been simulated by using gelatin and a multimode Nd:YAG laser. Because the point of maximun temperature of laser-irradiated gelatin exists below the surface due to surface cooling, evaporation at the boiling temperature is made explosively from below the surface. The important parameters of this process are the conduction loss to laser power absorption (defined as the conduction-to-laser power parameter, Nk), the convection heat transfer at the surface to conduction loss (defined as Bi), dimensionless extinction coefficient (defined as Br.), and dimensionless irradiation time (defined as Fo). Dependence of Fo on Nk and Bi has been observed by experiment, and the results have been compared with the numerical results obtained by solving a 2-dimensional conduction equation. Fo and explosion depth (from the surface to the point of maximun temperature) are increased when Nk and Bi are increased.To find out the minimum laser power for explosive evaporative removal process, steady state analysis has been also made. The limit of Nk to induce evaporative removal, which is proportional to the inverse of the laser power, has been obtained. 30622 T00401030622 ^x N1 and N2 gross neural action potentials were measured from the round window of the guinea pig cochlea at the onset of the acoustic stimuli. N1-N2 audiograms were made by means of regulating stimulant intensities in order to produce constant N1-N2 potentials as criteria for different input tone pip frequencies. The lowest threshold was measured with an input tone pip I5 dB SPL in intensity and 12 KHz in frequency when the animal was in normal physiological condition. The procedure of experimental measurements is explained in detail. This experimental approach is very useful for the investigation of the Cochlear function. Both noN1inear and active functions of the Cochlea can be monitored by N1-N2 audiograms. 30623 T00401030623 ^x In electrical impedance tomography(EIT), we use boundary current and voltage measurements toprovide the information about the cross-sectional distribution of electrical impedance or resistivity. One of the major problems in EIT has been the inaccessibility of internal voltage or current data in finding the internal impedance values. We propose a new image reconstruction method using internal current density data measured by NMR. We obtained a two-dimensional current density distribution within a phantom by processing the real and imaginary MR images from a 4.77 NMR machine. We implemented a resistivity mage reconstruction algorithm using the finite element method and sensitivity matrix. We presented computer simulation results of the mage reconstruction algorithm and furture direction of the research. 30624 T00401030624 ^x A new method of digital image analysis technique for discrimination of cancer cell was presented in this paper. The object image was the Thyroid eland cells image that was diagnosed as normal and abnormal (two types of abnormal: follicular neoplastic cell, and papillary neoplastic cell), respectively. By using the proposed region segmentation algorithm, the cells were segmented into nucleus. The 16 feature parameters were used to calculate the features of each nucleus. A9 a consequence of using dominant feature parameters method proposed in this paper, discrimination rate of 91.11% was obtained for Thyroid Gland cells. 30625 T00401030625 ^x An electrical stimulator was designed to induce locomotion for paraplegic patients caused by central nervous system injury. Optimal stimulus parameters, which can minimize muscle fatigue and can achieve effective muscle contraction were determined in slow and fast muscles in Sprague-Dawley rats. Stimulus patterns of our stimulator were designed to simulate electromyographic activity monitored during locomotion of normal subjects. Muscle types of the lower extremity were classified according to their mechanical property of contraction, which are slow muscle (msoleus m.) and fast muscle (medial gastrocneminus m., rectus femoris m., vastus lateralis m.). Optimal parameters of electrical stimulation for slow muscles were 20 Hz, 0.2 ms square pulse. For fast muscle, 40 Hz, 0.3 ms square pulse was optimal to produce repeated contraction. Higher stimulus intensity was required when synergistic muscles were stimulated simultaneously than when they were stimulated individually. Electrical stimulation for each muscle was designed to generate bipedal locomotion, so that individual muscles alternate contraction and relaxation to simulate stance and swing phases. Portable electrical stimulator with 16 channels built in microprocessor was constructed and applied to paraplegic patients due to lumbar cord injury. The electrical stimulator restored partially gait function in paraplegic patients. 30626 T00401030626 ^x Two-Dimensional modelling of the Cochlear biomechanics is presented in this paper. The Laplace partial differential equation which represents the fluid mechanics of the Cochlea has been transformed into two-dimensional electrical transmission line. The procedure of this transformation is explained in detail. The comparison between one and two dimensional models is also presented. This electrical modelling of the basilar membrane (BM) is clearly useful for the next approach to the further. Development of active elements which are essential in the producing of the sharp tuning of the BM. This paper shows that two-dimension model is qualitatively better than one-dimensional model both in amplitude and phase responses of the BM displacement. The present model is only for frequency response. However because the model is electrical, the two-dimensional transmission line model can be extended to time response without any difficult. 30627 T00401030627 ^x A method has been proposed for the fully automatic detection of left ventricular endocardial boundary in 2D short axis echocardiogram using geometric model. The procedure has the following three distinct stages. First, the initial center is estimated by the initial center estimation algorithm which is applied to decimated image. Second, the center estimation algorithm is applied to original image and then best-fit elliptic model estimation is processed. Third, best-fit boundary is detected by the cost function which is based on the best-fit elliptic model. The proposed method shows effective result without manual intervention by a human operator. 30628 T00401030628 ^x The intelligent trajectory control method that controls moving direction and average velocity for a prosthetic arm is proposed by pattern recognition and force estimations using EMG signals. Also, we propose the real time trajectory planning method which generates continuous accelleration paths using 3 stage linear filters to minimize the impact to human body induced by arm motions and to reduce the muscle fatigue. We use combination of MLP and fuzzy filter for pattern recognition to estimate the direction of a muscle and Hogan's method for the force estimation. EMG signals are acquired by using a amputation simulator and 2 dimensional joystick motion. The simulation results of proposed prosthetic arm control system using the EMf signals show that the arm is effectively followed the desired trajectory depended on estimated force and direction of muscle movements. 30638 T00401030638 ^x A new neural network architecture for the recognition of patterns from images is proposed, which is partially based on the results of physiological studies. The proposed network is composed of multi-layers and the nerve cells in each layer are connected by spatial filters which approximate receptive fields in optic nerve fields. In the proposed method, patterns recognition for complicated images is carried out using global features as well as local features such as lines and end-points. A new generating method of matched filers representing global features is proposed in this network. 30659 T00401030659 ^x An implementation scheme of the magnetic nerve stimulator using a switching mode power supply is proposed. By using a switching mode power supply rather than a conventional linear power supply for charging high voltage capacitors, the weight and size of the magnetic nerve stimulator can be considerably reduced. Maximum output voltage of the developed magnetic nerve stimulator using the switching mode power supply is 3,000 volts and switching time is about 100 msec. Experimental results or human nerve stimulations using the developed stimulator are presented. 30768 T00401030768 ^x In this paper, we describe the design methodology and specifications of the developed module-based bedside monitors for patient monitoring. The bedside monitor consists of a main unit and module cases with various parameter modules. The main unit includes a 12.1" TFT color LCD, a main CPU board, and peripherals such as a module controller, Ethernet LAN card, video card, rotate/push button controller, etc. The main unit can connect at maximum three module cases each of which can accommodate up to 7 parameter modules. They include the modules for electrocardiograph, respiration, invasive blood pressure, noninvasive blood pressure, temperature, and SpO2 with Plethysmograph.

  • PDF

Studies on the selection in soybean breeding. -II. Additional data on heritability, genotypic correlation and selection index- (대두육종에 있어서의 선발에 관한 실험적연구 -속보 : 유전력ㆍ유전상관, 그리고 선발지수의 재검토-)

  • Kwon-Yawl Chang
    • KOREAN JOURNAL OF CROP SCIENCE
    • /
    • v.3
    • /
    • pp.89-98
    • /
    • 1965
  • The experimental studies were intended to clarify the effects of selection, and also aimed at estimating the heritabilities, the genotypic correlations among some agronomic characters, and at calculating the selection index on some selective characters for the selection of desirable lines, under different climatic conditions. Finally practical implications of these studies, especially on the selection index, were discussed. Twenty-two varieties, determinate growing habit type, were selected at random from the 138 soybean varieties cultivated the year before, were grown in a randomized block design with three replicates at Chinju, Korea, under May and June sowing conditions. The method of estimating heritabilities for the eleven agronomic characters-flowering date, maturity date, stem length, branch numbers per plant, stem diameter, plant weight, pod numbers per plant, grain numbers per plant and 100 grain weight, shown in Table 3, was the variance components procedures in a replicated trial for the varieties. The analysis of covariance was used to obtain the genotypic correlations and phenotypic correlations among the eight characters, and the selection indexes for some agronomic characters were calculated by Robinson's method. The results are summarized as follows: Heritabilities : The experiment on the genotype-environment interaction revealed that in almost all of the characters investigated the interaction was too large to be neglected and materially affected the estimates of various genotypic parameters. The variation in heritability due to the change of environments was larger in the characters of low heritability than in those of high heritability. Heritability values of flowering date, fruiting period (days from flowering to maturity), stem length and 100 grain weight were the highest in both environments, those of yield(grain weight) and other characters were showed the lower values(Table 3). These heritability values showed a decreasing trend with the delayed sowing in the experiments. Further, all calculated heritability values were higher than anticipated. This was expected since these values, which were the broad sense heritability, contain the variance due to dominance and epistasisf in addition to the additive genetic variance. Genotypic correlations : Genotypic correlations were slightly higher than the corresponding phenotypic correlations in both environments, but the variation in values due to the change of environment appeared between grain weight and some other characters, especially an increase between grain weight and flowering date, and the total growing period(Table 6). Genotypic correlations between grain weight and other characters indicated that high seed yield was genetically correlated with late flowering, late maturity, and the other five characters namely branch numbers per plant, stem diameter, plant weight, pod numbers per plant and grain numbers per plant, but not with 100 grain weight of soybeans. Pod numbers and grain numbers per plant were more closely correlated with seed yields than with other characters. Selection index : For the comparison and the use of selection indexes in the selection, two kinds of selection indexes were calculated, the former was called selection index A and the later selection index B as shown in Table 7. Selection index A was calculated by the values of grain weight per plant as the character of yield(character Y), but the other, selection index B, was calculated by the values of pod numbers per plant, instead of grain weight per plant, as the character of yield'(character Y'). These results suggest that selection index technique is useful in soybean breeding. In reality, however, as the selection index varies with population and environment, it must be calculated in each population to which selection is applied and in each environment in which the population is located. In spite of the expected usefulness of selection index technique in soybean breeding, unsolved problems such as the expense, time and labor involved in calculating the selection index remain. For these reasons and from these experimental studies, it was recognized that in the breeding of self-fertilized soybean plants the selection for yield should be based on a more simple selection index such as selection index B of these experiments rather than on the complex selection index such as selection index A. Furthermore, it was realized that the selection index for the selection should be calculated on the basis of the data of some 3-4 agronomic characters-maturity date(X$_1$), branch numbers per plant(X$_2$), stem diameter(X$_3$) and pod numbers per plant etc. It must be noted that it should be successful in selection to select for maturity date(X$_1$) which has high heritability, and the selection index should be calculated easily on the basis of the data of branch numbers per plant(X$_2$), stem diameter(X$_3$) and pod numbers per plant, directly after the harvest before drying and threshing. These characters should be very useful agronomic characters in the selection of Korean soybeans, determinate growing habit type, as they could be measured or counted easily thus saving time and expense in the duration from harvest to drying and threshing, and are affected more in soybean yields than the other agronomic characters.

  • PDF

Primiparas만 Perceptions of Their Delivery Experience and Their Maternal-Infant Interaction : Compared According to Delivery Method (초산모의 분만유형별 분만경험에 대한 지각과 모아상호작용 과정에 관한 연구)

  • 조미영
    • Journal of Korean Academy of Nursing
    • /
    • v.20 no.2
    • /
    • pp.153-173
    • /
    • 1990
  • One of the important tasks for new parents. especially mothers, is to establish warm, mutually affirming interpersonal relationships with the new baby in the family, with the purpose of promoting the healthy development of the child and the wellbeing of the whole family. Nurses assess the quality of the behavioral characteristics of the maternal-infant interaction. This study examined the relationships between primiparas pereptions of their delivery experience and their maternal infant interaction. It compared to delivery experience of mothers having a normal vaginal delivery with those having a casearean section. The purpose was to explore the relationships between the mother's perceptions of her delivery experience with her maternal infant interaction. The aim was to contribute to the development of theoretical understanding on which to base care toward promoting the quality of maternal-infant interaction. Data were collected directly by the investigator and a trained associate from Dec. 1, 1987 to March 8, 1988. Subjects were 3 random sample of 62 mothers, 32 who had a normal vaginal delivery and 30 who had a non-elective cesarean section (but without other perinatal complications) at three general hospitals in Seoul. Instruments used were the Stainton Parent -infant Interaction Scale(1981) and the Marut and Mercer Perception of Birth Scale(1979). The first observations were made in the delivery room (for vaginally delivered mothers only), followed by day 1, day 2, day 3, and 2 weeks, 4 weeks, 6 weeks and 8 weeks after birth, for a total of 7-8 contacts(Cesarean section mothers were observed on days 4 and 5 but the data not used for analysis). Observations in the hospital were made during the hour prior to scheduled feedings. The infant was placed beside the mother. Later contacts were made at home. Data analysis was done by computer using as SPSS program and indulded X² test, paired t-test, t-test, and Pearson Correlation coefficient ; the results were as follows. 1. Mothers who had a normal vaginal delivery tended to perceive the delivery experience more positively than cesarean section mothers(p=0.002). The finding supported the hypothesis I that perception of delivery would vary according to the method of delivery. Mothers' perceptions of birth were classified into three dimensions, labor, delivery and the bady. There was a significantly different and positive perception by the vaginally delivered mothers to the delivery experience(p=0.000) but no differences for labor or the bady according to the delivery method(p=0.096, p=0.389), 2. Mothers who had a normal vaginal delivery had higher average maternal-infant interaction scores(p=0.029) than mothers who had a cesarean section. There were similar higher scores for the 1st day(p=0.042), 2nd day (p=0.009), and the 3rd day(p=0.006) after delivery but not for later times. The findings supported the hypothesis Ⅱ that there would be differences in maternal-infant interaction for mothers having vaginal and cesarean section deliveries. However these differences deccreased section deliveries. However these differences decreased over time . by eight weeks the scores for vaginal delivery mothers averaged 8.1 and for cesarean section mothers, 7.9. 3. The more highly positive the pereption of the delivery experience, the higher the maternal-infant interaction score for all subjects(F=.3206, p=.006). The findings supported the hypothesis Ⅲ that there would be correlations between perceptions of delivery and maternal-infant interaction. The maternal infant interaction was highest when the perception of the bady and deliery was positive(r=.4363, p=.000, r=.2881, p=.012). No correlations between perceptions of labor and maternal-infant interaction were found(p=0.062). 4. The daily maternal-infant interaction score for the initial contact after birth to 8 weeks postpartum had the lowest average score 5.20 and the highest 7.98(in a range of 0-10). This subjects group of mothers needed nursing intervention to promote their maternal- infant interaction. The daily scores for the maternal-infant over the period of eight weeks. However, there were significantly different increases in maternal-infant interaction only from the first to second day(p=0.000) and from the fourth to sixth weeks after birth(P=0.000). 5. When the eight items of maternal-infant interaction were evaluated separately, “Expresses feelings about her role as mother” had the highest average score, 1.64(ina range of 0-3)and “Speaks to baby” the lowest, 0.9. All items, with the possible exception of “Expresses feelings about her role as mother”, suggested the subjects' need of nursing intervention to promote maternal-infant interaction. 6. There were positive correlations between certain general charateristis, namely, both a higher economic status(p=0.002) and breast feeding(p=0.202) and maternal - infant interaction. There were positive correlations between a mother's confidence in her role as a mother and the perception of the birth experience(p=0.004). For mothers who had a cesarean section, a positive perception of the birth experience was related to the duration of her marriage(p=0.010), a wanted pregnancy (P=0.030) and her confidence in her role as a mother(p=0.000). Pereptions of birth for mothers who had a normal vaginal delivery were positive than those for mothers who had a cesarean section. The level of maternalinfant interaction for mothers delivered vaginally was higher than for cesarean section mothers. The relationship between perception of birth and materanalinfant interaction was confirmed. Cesarean section has an impact on the mother's perceived experience of birth which, in turn, is positively related to maternal-infant in turn, is positively related to maternal-infant interaction. Nursing intervention to enhance maternal-infant interaction should begin in prenatal classes with an exploration of the potential impact of cesarean section on the perceptions of the birth experience and continue throughout the perinatal and post-natal periods to promote the mother's ability to control with this crisis experience and to mobilize social support. Nursing should help transform a relatively negatively perceived experience into an accepted, positively perceived and self affirming experience which enhances the maternal-infant relationship.

  • PDF

Estimation of Productivity for Quercus variabilis Stand by Forest Environmental Factors (삼림환경인자(森林環境因子)에 의한 굴참나무임분(林分)의 생산력추정(生産力推定))

  • Lee, Dong Sup;Chung, Young Gwan
    • Journal of Korean Society of Forest Science
    • /
    • v.75 no.1
    • /
    • pp.1-18
    • /
    • 1986
  • This study was initiated to estimate productivity of Quercus variabilis stand. However the practical objective of this study was to provide some information to establish the basis of selecting the suitable site for Quercus variabilis. The productivity measured in terms of DBH, height, basal area and stem volume was hypothesized, respectively, to be a function of a group of factors. This study considered 32 factors, 20 of which were related to the forest environmental factors such as tree age, latitude, percent slope, etc. and the rest of which were related to soil factors such as soil moisture, total nitrogen, available $P_2O_5$, etc. The data on 4 productivity measurements of Quercus variabilis growth and related factors cited were collected from 99 sample plots in Kyeongbook and chungbook provinces. Some factors considered were, in nature, discrete variables and the others continuous variables. Each kind of factor was classified into 3 or 4 categories and total numbers of such categories were eventually amounted to 110. Then each category was treated as an independent variable. This is amounted to saying that individual variable was treated a dummy variable and assigned a value 1 or 0. However the first category of each factor was deleted from the normal equation for statistical consideration. First of all, each of 4 productivity measurements of Quercus variabilis growth was regressed and, at the same time, those 110 categories. Secondly, the partial correlation coefficients were measured between each pair of 4 productivity measurements and 32 individual foctors. Finally, the relative scores were estimated in order to derive the category ranges. The result of these statistical analyses could be summarized as follows: 1) Growth measurement in terms of height seems to be a more significant criterion for estimation of productivity of Quercus variabilis. 2) Productivity of forest on stocked land may better be estimated in terms of forest environmental factors, on the other hand, that of unstocked land may be estimated in terms of physio-chemical factors of soil. 3) The factors that a strongly positive relation to all growth factors of tree are age group, effective soil, soil moisture, etc. This implies that these factors might effectively be used for criteria for selecting the suitable site for Quercus variabilis. 4) Parent rock, latitude, total nitrogen, age group, effective soil depth, soil moisture, organic matter, etc., had more significant category range for tree growth. Therefore, the suitable site for Quercus variabilis may be selected, based on this information. In conclusion, the above results obtained by the multivariable analysis can be not only the important criteria for estimating the growth of Quercus variabilis but also the useful guidance for selecting the suitable sites and performing the rational of Quercus variabilis forest.

  • PDF

A Study on the Perceived Stress of Mothers in Neonatal Intensive Care Unit (신생아 중환자실에 입원한 환아 어머니의 스트레스)

  • Choi Sung Hee
    • Child Health Nursing Research
    • /
    • v.4 no.1
    • /
    • pp.60-75
    • /
    • 1998
  • The parents have much expectation upon the pregnancy and child birth, and in most cases, they expect the healthy parturient child. However, we can be placed on the high-risk conditions which have the physical, social and immature infant, due to the unexpected results, among the new-born. Accordingly, these high-risk newborn and premature infants will be mostly in NICU, which the concentrated medical treatment can be given, upon their conditions. After their birth and during these periods, they will be divided from the parents, and the nurse will accomplish the bringing-up activities which they can take care of the infant, expected by the parents after their birth. The hospitalization of high-risk newborn including these premature infants is the shocking experience to the parents of family, and thus they can feel the fear and uneasiness, and these reactions of parents are troubled in the behavior at the usual days, and cause the disorder and spiritless status, and these results break the supporting ability of parents, and cause the obstruction. Also, the unavoidable division between the parents and the children as like hospitalization of children can make the parents to feel the alienation emotionally, and this causes the results which the pride on the bringing-up ability of baby gets to be lost. These problems can cause the difficulties on the bonding or the parenting in the further days, and can be related to the neglect and abuse of children. Also, it is gradually increased to study and report which the emotional division by the physical division between the mother and the baby obstructs the normal affection course between the parent and the infant. The stress caused by the birth and the hospitalization of high-risk newborn, as like this, is important in the points which it can uncertainly affect the potential energy for the relationship of parent-child who are finally healthy. Accordingly, the significance and purpose of this study are to understand the contents and degree of stress which the parents of high-risk newborn including the immature child can be experienced from the hospitalization of ICU for their new borns, and thus to offer the basic program to the nursing intervention program for these. The subject of this study is the mother of newborn in NICU of 10 General Hospitals located at the 3one of Pusan, Korea from September 1997 to October 1997, and thus makes the subject of 95 person of parents who agreed to take part in the study and it is descriptive study related to the stress of mother having the newborn in NICU. The method is based on the preceding study related to the stress of mother having the experience of child hospitalization and chronic disease child, and then acquires the advice of specialists group as like 5 nursing professors, and then is amended and supplemented. Total number of questions is 43 items and consists of 5 factors as like medical treatment &nursing procedures, disease status & prognosis, role of parents, communication & inter-personal relationships, hospital environment, and is 5 point Likert Scale. The reliability of this study method is very highly shown to be Cronbach α=0.95. The collected data is analysed as Average, Frequency, Standard Deviation, T-test, ANOVA, Pearson Correlation Coefficient, Duncan multifulrange test by use of SPSS /PC (V7.5). The results of this study is summarized as under. 1. Every characteristics of subject is which the party of mother is 28.70age(±7.48) in the average ages, 51% in the high-school graduate, 38.5% in the christianity, total monthly income is 212.55 thousand won(±1.971), 74.5% in the housewife, 72.9% in the parents and children together living and the number of children to be 1.48person(± 0.6) in average, the recognition on the prognosis of baby is 74.0% in 'Don't know', the relationship with the husband after the hospitalization of babyis 37.3% in 'More Intimate', the relationship with the family of husband to be 48% in 'No-change', and the degree which is consulted with the husband about the baby is 55% in 'very frequently' and the visiting number per week is 4.59(±1.63) in average and the accompanying person in the time of visiting is which the number of husband is 56.3% and thus is the highest. The characteristics of baby is which the age is 21.88days(±16.47) after the birth in average, the sex to be 50 person in the female 52.1% and the order of birth to be 54.2% in the first chid, and the weight in the birth to be 2770gm(±610) and the height in the birth to be 46.26cm(±7.62) in aver age. The medical diagnosis is 37.5% in the premature infant, the career of hospitalization is 96.9% in 'None', and the operation plan is 90.6% in 'None' and the execution of operation is 88% in 'None' and the nursing of incubator is 55.2% in 'Yes', and the method of feeding is 50.5% in 'Oral' and the contents of feeding is 46.9% in the 'Milk'. 2. The total stress degree of subject is almost highly shown to be as 3.36(±0.86). If it is compared upon each cause, 'stress on disease status & prognosis' is highest 3.79(±1.28), and it is in the order of 'stress on medical treatment & nursing procedures' 3.70(±0.93), 'stress on hospital environment' 3.14(±0.86), 'stress on role of parents' 3.18(±0.92) and 'stress on communication & inter personal relationship' 2.62(± 0.77) 3. As the results of checking the notworthiness of stress degree upon each variable of subject, the variable showing the noted difference was the birth weight(γ=-0.16, P=0.04), birth height(γ=-0.23, P=0.03), nursing in the incubator(F=8.93, P=0.04), feed method(F=2.94, P=0.04). That is to say, it is shown which the smaller the birth weight is, the higher the stress degree of mother is noteworthily. Also, the smaller the birth height baby is, the higher the stress of mother is. In the incubator, it os shown which the mother whose baby is nursing in the incubator is higher in the stress degree than other mothers. Upon the feeding method of baby, that is to say, TPNis the highest, and it is shown in the order of NPO, Tube feeding, and P.O. feeding. When we review the above-mentioned results, as the status is serious, it is thought which we include the supporting nursing for coping with the stress of parents in the setting-up od nursing plan for the baby in the NICU.

  • PDF