• 제목/요약/키워드: timber frame

검색결과 48건 처리시간 0.02초

Evaluation of the Residual Performance of Partially Charred Components of Old Wooden Structure I - Use of Ultrasonic Velocity and Testing of the Drilling Resistance -

  • Lee, Hyun-Mi;Hwang, Won-Joung;Lee, Dong-Heub;Kim, Hong Sik
    • Journal of the Korean Wood Science and Technology
    • /
    • 제42권2호
    • /
    • pp.193-206
    • /
    • 2014
  • Residual performance of old architectural wood which has been damaged was measured using Nondestructive Evaluation (NDE). The wood Pole Tester was used to assess ultrasonic velocity inside wood and drill resistance was determined using an IML-resistograph. For ultrasonic measurements squared timber and circular timber's measurements were separately conducted with 1,300 m/s as the standard ultrasonic velocity. The standard wood samples divided into two parts; a non-sound area (below the standard), and a sound area (above the standard). Furthermore, schematization of wood was compared with results naked eye observation. The drilling resistance test was performed for both length and thickness direction in wood. The internal of the drilling was set at 30 cm (length direction), 5 cm (width direction) and 30cm (thickness direction). A non-sound area was defined as that 1) amplitude is below 20% and 2) carbonization and deterioration are related.

Study on mechanical behaviors of column foot joint in traditional timber structure

  • Wang, Juan;He, Jun-Xiao;Yang, Qing-Shan;Yang, Na
    • Structural Engineering and Mechanics
    • /
    • 제66권1호
    • /
    • pp.1-14
    • /
    • 2018
  • Column is usually floating on the stone base directly with or without positioning tenon in traditional Chinese timber structure. Vertical load originated by the heavy upper structure would induce large friction force and compression force between interfaces of column foot and stone base. This study focused on the mechanical behaviors of column foot joint with consideration of the influence of vertical load. Mechanism of column rocking and stress state of column foot has been explored by theoretical analysis. A nonlinear finite element model of column foot joint has been built and verified using the full-scale test. The verified model is then used to investigate the mechanical behaviors of the joint subjected to cyclic loading with different static vertical loads. Column rocking mechanism and stress distributions of column foot were studied in detail, showing good agreement with the theoretical analysis. Mechanical behaviors of column foot joint and the effects of the vertical load on the seismic behavior of column foot were studied. Result showed that compression stress, restoring moment and stiffness increased with the increase of vertical load. An appropriate vertical load originated by the heavy upper structure would produce certain restoring moment and reset the rocking columns, ensuring the stability of the whole frame.

보 결구를 통해 본 중국 절강지역과 고려시기 목조건축과의 관계 - '차견(箚牽)'과 초방(草枋), '묘량(猫梁)'과 우미량(牛尾梁)을 중심으로 - (Relationship between the Zhejiang Province area(China) and wooden architecture from the Koryo Period based on the beam and the structure)

  • 이용준
    • 건축역사연구
    • /
    • 제15권4호
    • /
    • pp.75-86
    • /
    • 2006
  • Korea is closed to China in the geographical position and is related to China as two countries have developed similar culture, art, and social systems. Architecture is a kind of culture and has advanced in the wooden architecture with a considerable change. The study investigated a phylogenetic relationship between two countries based on characteristics of architectural universality. With comparison and analysis on the common feature and difference of the beam and structure in the wooden architecture from the Koryo and Zhejiang Province(China), the systemicity of the wooden architecture was examined. The beam is a part of timber which is consist of the wooden structure frame and also a crucial subject to understand a development process of the wooden architecture.

  • PDF

The Albizzia Tower

  • Mathurin Harde;Cyrille Le Bihan;Leonardo Gambatesa;Antoine Bauge
    • 국제초고층학회논문집
    • /
    • 제13권2호
    • /
    • pp.187-194
    • /
    • 2024
  • The 53-meter tall Albizzia Tower is a white, mineral building with a mixed concrete and wood structure. It harmoniously interacts with the high rises of La Confluence. Its base is largely open, in direct relation to the public space. The spaces are mutable, reversible, moldable thanks to a streamlined structure: posts, beams in glued laminated wood, with posts pushed back on the facade to facilitate the layout of office and housing floors, CLT floors with a span of 7 meters.

Lateral Resistance of CLT Wall Panels Composed of Square Timber Larch Core and Plywood Cross Bands

  • JANG, Sang Sik;LEE, Hyoung Woo
    • Journal of the Korean Wood Science and Technology
    • /
    • 제47권5호
    • /
    • pp.547-556
    • /
    • 2019
  • Thinned, small larch logs have small diameters and no value-added final use, except as wood chips, pallets, or fuel wood, which are products with very low economic value; however, their mechanical strength is suitable for structural applications. In this study, small larch logs were sawed, dried, and cut into square timbers (with a $90mm{\times}90mm$ cross section) that were laterally glued to form core panels used to manufacture cross-laminated timber (CLT) wall panels. The surface and back of these core panels were covered with 12-mm-thick structural plywood panels, used as cross bands to obtain three-ply CLT wall panels. This attachment procedure was conducted in two different ways: gluing and pressing (CGCLT) or gluing and nailing (NGCLT). The size of the as-manufactured CLT panels was $1,220mm{\times}2,440mm$, the same as that of the plywood panels. The final wall panels were tested under lateral shear force in accordance with KS F 2154. As the lateral load resistance test required $2,440mm{\times}2,440mm$ specimens, two CLT wall panels had to be attached in parallel. In addition, the final CLT panels had tongued and grooved edges to allow parallel joints between adjacent pieces. For comparison, conventional light-frame timber shear walls and midply wall systems were also tested under the same conditions. Shear walls with edge nail spacing of 150 mm and 100 mm, the midply wall system, and the fabricated CGCLT and NGCLT wall panels exhibited maximum lateral resistances of 6.1 kN/m (100%), 9.7 kN/m (158%), 16.9 kN/m (274%), 29.6 kN/m (482%), and 35.8 kN/m (582%), respectively.

부분 무기둥 비계구조 골조 거동에 관한 실험적 연구 (An Experimental Study on the Behavior of Scaffolding System without a Part of Column)

  • 손기상;정희종
    • 한국안전학회지
    • /
    • 제28권4호
    • /
    • pp.66-71
    • /
    • 2013
  • There is a critically structural problem of scaffolding system when one of scaffold columns is remove to be used as a gangway for their temporary office in the structure before finishing all such as an apartment or office building. This is not used to checking to structurally checking at a construction site. This study is to find out which system at a site will be more effective and low-cost-high effectiveness of aluminum ladder, timber ladder, ${\phi}$1/2 inch steel pipe truss with a type of concave, convex warren truss ladders. Theses are structurally tested with horizontal set as a truss type with 1.8 meter long. Concentrated load has been loaded at the upper center of the system and checked its strain at the bottom center, using aluminum-use strain gage and steel-use gauge have been attached concave warren truss with diameter 1/2 inch has 14% stronger than convex truss. Convex truss has almost same strength as an aluminum ladder truss, it is found out.

미국(美國) 북장로회(北長老會) 청주선교부(淸州宣敎部) 건축(建築)의 형성(形成)과 특성(特性) (A Study on the Formation and Character of Cheong Ju Presbyterian Missionary Architecture from 1900 to 1945)

  • 도선붕;한규영
    • 한국농촌건축학회논문집
    • /
    • 제3권1호
    • /
    • pp.25-40
    • /
    • 2001
  • In this study, I investigate the formation process of the American presbyterian missionary architecture in Cheong Ju area from 1900 to 1945, which we may think 'the part of Korean modern architecture'. I have examined and analyzed the 18 buildings for the sake of the interpretation with the words of formation process and characteristics . And I can put my idea in order as follows. Firstly, the formation process is 1) buy and modify a Korean style (thatch or tile roofed) building for their need and use it as a gate quaters or house, church, hospital, school, book store, 2) build a Korean style (tile roofed) building and use it-house, hospital, school, 3) build a Western style (timber structured and zinc roofed) building and use it- church, 4) build a Western style (masonry structured and tile or zinc roofed) building and use ithouse, church, school and hospital. Secondly, the characteristics is 1) In the Korean style building, the missionaries change into the function to match with their purpose. they modify the Korean style timber structure by influx of building material-brick, glass, carpet etc. they occupy into the Korean existing residential area. 2) In the Western style building, the missionaries build the house correspond with their living pattern. they build the church with the eclectic of Western and Korean timber frame. and also build the house and hospital with the eclectic of Western and Korean masonry structure. their building located in the isolate hill separated from the existing Korean residential area.

  • PDF

H형강 접합부를 갖는 목조 골조의 보강형식에 따른 구조성능 (Structural performance by strengthening types of wood frames using H shaped steel joints)

  • 김순철;문연준;양일승;박근홍
    • KIEAE Journal
    • /
    • 제8권3호
    • /
    • pp.77-83
    • /
    • 2008
  • The effective mixture of structural laminated timber and other materials is expected to extend the potentials of building structures because of the potentials to realize high performance in structural safety. The classical joint types using drift pin and bolts are occurred local failures due to the small bearing area. In result, new joints using H shaped steel were suggested in this research. The objective of this study is to evaluate elasto-plastic behaviors by strengthening types of wood frames with new joints connecting structural laminated timber with H shaped steel. A total of five specimens of about one-second scale were tested. Specimens had columns with 1,050 height and $84mm{\times}100mm$ section, and a beams with 1,950mm length and $130mm{\times}100mm$ section. Also, the specimens were stiffened by brace, hwang-toh brick, and autoclaved lightweight concrete. The results of the test showed that the specimen stiffened with autoclaved lightweight concrete was characterized by fairly good strength and stiffness than those of the other specimens. Initial stiffness of H-2.0D-NS specimen with 2 times inserting length of beam height showed 1.33 times than that of H-1.5D-NS specimen. However, the strength of H-2.0D-NS specimen has not improved too much than H-1.5D-NS specimen.

Influence of Air-tightness on Heat Energy Performance in Post and Beam Building with Exposed Wood Frame

  • Kim, Hyun-Bae;Kim, Se-Jong;Oh, Jung-Kwon;Park, Joo-Saeng;Lee, Jun-Jae
    • Journal of the Korean Wood Science and Technology
    • /
    • 제40권5호
    • /
    • pp.319-326
    • /
    • 2012
  • Han-green building is one of the modernized Korean traditional buildings developed by Korea Forest Research Institute. This building was developed to increase the competitiveness of Korean traditional building using state-of-art technologies; hence Han-green building has the inherent characteristics of traditional building such as exposed wood frame in wall. Because of discontinuity in wall by the exposed wood frame, there is a concern on heat-air leaking in terms of energy performance. In this study, air-tightness of Han-green building was evaluated to investigate the influence of gaps between frames and in-fill walls. Blower door test was carried out to evaluate the air-tightness, and air-change rate (ACH50) was evaluated by averaging four set of pressurization and depressurization test. The air-change rate of Han-green house was 5.91 $h^{-1}$. To improve energy performance of Han-green house, thermal infrared images of Han-green house were taken in winter with heating to find out where the heat loss occurred. It was found that the building lost more heat through gaps between frames and in-fill walls rather than through other parts of this building. After covering all the gaps by taping, the blower door test was performed again, and the air-change rate was improved to 5.25 $h^{-1}$. From this analysis, it was concluded that the heated air can leak through the gaps between frames and walls. Therefore, when one designs the post and beam building with exposed frame, the detail design between frame and wall needs to be carefully dealt. However, Han-green building showed relatively high air-tightness comparing with other country research results.

바닥슬래브 하부 구조의 개선을 통한차음특성 변화에 관한 실험적 연구 - 흡.차음재를 중심으로 - (An Experimental Study on the Sound Insulation Performance Characteristics due to the Variation of Ceiling Structures - Focused on the Sound-absorbing and Insulation materials -)

  • 김준엽;기노갑;정일호;정환욱;송민정;김선우
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2000년도 추계학술대회논문집
    • /
    • pp.506-511
    • /
    • 2000
  • The aim of this study is to suggest a fundamental data to improve the sound insulation performance of floor. To achieve the aim of this study, 8 types of sound-absorbing and sound insulation materials were installed under the slab, and the floor systems were compared to the general floor system which was composed of slab, timber frame, gypsum board and wallpaper.

  • PDF