• Title/Summary/Keyword: tilt error

Search Result 148, Processing Time 0.026 seconds

Stereo Object Tracking and Multiview image Reconstruction System Using Disparity Motion Vector (시차 움직임 벡터에 기반한 스데레오 물체추적 및 다시점 영상복원 시스템)

  • Ko Jung-Hwan;Kim Eun-Soo
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.31 no.2C
    • /
    • pp.166-174
    • /
    • 2006
  • In this paper, a new stereo object tracking system using the disparity motion vector is proposed. In the proposed method, the time-sequential disparity motion vector can be estimated from the disparity vectors which are extracted from the sequence of the stereo input image pair and then using these disparity motion vectors, the area where the target object is located and its location coordinate are detected from the input stereo image. Being based on this location data of the target object, the pan/tilt embedded in the stereo camera system can be controlled and as a result, stereo tracking of the target object can be possible. From some experiments with the 2 frames of the stereo image pairs having 256$\times$256 pixels, it is shown that the proposed stereo tracking system can adaptively track the target object with a low error ratio of about 3.05$\%$ on average between the detected and actual location coordinates of the target object.

Comparison of Motion Sensor Systems for Gait Phase Detection (보행주기 검출용 모션 센서 시스템의 비교)

  • Park, Sun-Woo;Sohn, Ryang-Hee;Ryu, Ki-Hong;Kim, Young-Ho
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.27 no.2
    • /
    • pp.145-152
    • /
    • 2010
  • Gait phase detection is important for evaluating the recovery of gait ability in patients with paralysis, and for determining the stimulation timing in FES walking. In this study, three different motion sensors(tilt sensor, gyrosensor and accelerometer) were used to detect gait events(heel strike, HS; toe off, TO) and they were compared one another to determine the most applicable sensor for gait phase detection. Motion sensors were attached on the shank and heel of subjects. Gait phases determined by the characteristics of each sensor's signal were compared with those from FVA. Gait phase detections using three different motion sensors were valid, since they all have reliabilities more than 95%, when compared with FVA. HS and TO were determined by both FVA and motion sensor signals, and the accuracy of detecting HS and TO with motion sensors were assessed by the time differences between FVA and motion sensors. Results show of that the tilt sensor and the gyrosensor could detect gait phase more accurately in normal subjects. Vertical acceleration from the accelerometer could detect HS most accurately in hemiplegic patient group A. The gyrosensor could detect HS and TO most accurately in hemiplegic patient group A and B. Valid error ranges of HS and TO were determined by 3.9 % and 13.6 % in normal subjects, respectively. The detection of TO from all sensor signals was valid in both patient group A and B. However, the vertical acceleration detected HS validly in patient group A and the gyrosensor detected HS validly in patient group B. We could determine the most applicable motion sensors to detect gait phases in hemiplegic patients. However, since hemiplegic patients have much different gait patterns one another, further experimental studies using various simple motion sensors would be required to determine gait events in pathologic gaits.

Tolerance analysis of Multi-Configurative Microscopic System for Inspecting the Wire-Bonding Status of Semiconductor Chips (반도체 와이어 본딩 검사용 다중배치 현미경 광학계에 대한 공차분석)

  • Ryu, Jae-Myung;Kim, Jae-Bum;Kang, Geon-Mo;Jung, Jin-Ho;Baek, Seung-Sun;Jo, Jae-Heung
    • Korean Journal of Optics and Photonics
    • /
    • v.17 no.2
    • /
    • pp.149-158
    • /
    • 2006
  • We have analyzed various tolerances of the multi-configurative microscopic system for inspecting the wire-bonding of a reed frame by using the Gaussian bracket method and the equivalent lens method. The tolerances for the curvature and the thickness, which are axial symmetric tolerances, are given by varying the back focal length within a fecal depth under diffraction-limited conditions. Moreover, by using the trial and error method, the axial non-symmetric tolerances for decenter and tilt are established by assigning the 5% variation of MTF(modulation transfer function) at the spatial frequency of 50 lp/mm and at the field angle of 0.7 field. As the tolerances with the most probable distribution are distributed within the range of the decay rate of less than 5% independent of the probability distribution of tolerances, we can achieve completely the desired design performances of the multi-configurative microscopic system by using the various ranges of these tolerances.

An Adaptive Pointing and Correction Algorithm Using the Genetic Algorithm (유전자 알고리즘을 이용한 적응적 포인팅 및 보정 알고리즘)

  • Jo, Jung-Jae;Kim, Young-Chul
    • Journal of Korea Multimedia Society
    • /
    • v.16 no.1
    • /
    • pp.67-74
    • /
    • 2013
  • In this paper, we propose the pointing and correction algorithm for optimized performance based on Bluetooth communication. The error from the accelerometer sensor's output must be carefully managed as the accelerometer sensor is more sensitive to data change compared to that of the gyroscope sensor. Thus, we minimize the noise by applying the Kalman filter to data for each axis from the accelerometer. In addition, we can also obtain effect compensating the hand tremor by applying the Kalman filter to the data variation for x and y. In this study, we extract data through the Quaternion mapping process on data from the accelerometer and gyroscope. In turn, we can obtain a tilt compensation by applying a compensation algorithm with acceleration of the gravity of the extracted data. Moreover, in order to correct the inaccuracy on smart sensor due to the rapid movement of a device, we propose a adaptive pointing and correction algorithm using the genetic approach to generate the initial population depending on the user.

Effects of the Geometrical Misalignment on the MTF Measurement (변조전달함수 측정에 있어 기하학적 조정 불량이 해상도에 미치는 영향)

  • Kim, Jun-Woo
    • Journal of the Korean Society of Radiology
    • /
    • v.15 no.5
    • /
    • pp.705-713
    • /
    • 2021
  • The modulation transfer function (MTF) is calculated to analyze the resolution of the spatial frequency of the image acquired from the x-ray imaging system. In general, the response function of the detector acquires a line spread function (LSF) using a slit-camera, and derives a modulation transfer function through a Fourier transform. Because of the fact that the x-ray must always be incident on the center of the slit-camera, the tilt of the detector and slit-camera caused by the experimenter will affect the detector performance. In addition, if the tilt increases, the performance evaluation of the x-ray image system will be problematic. In this study, we analyzed the experimental and analytical models in the modulation transfer function, ie, the Fourier domain, based on the experimental error and analyzed the effect on the spatial frequency. Furthermore, performance evaluation is being carried out for various x-ray imaging systems, and experimental errors are indispensable, and the extent to which they can be tolerated should be reviewed.

A New Height Estimation Scheme Using Geometric Information of Stereo Camera based on Pan/tilt control (팬/틸트 제어기반의 스데레오 카메라의 기하학적 정보를 이용한 새로운 높이 추정기법)

  • Ko Jung-Hwan;Kim Eun-Soo
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.31 no.2C
    • /
    • pp.156-165
    • /
    • 2006
  • In this paper, a new intelligent moving target tracking and surveillance system basing on the pan/tilt-embedded stereo camera system is suggested and implemented. In the proposed system, once the face area of a target is detected from the input stereo image by using a YCbCr color model and phase-type correlation scheme and then, using this data as well as the geometric information of the tracking system, the distance and 3D information of the target are effectively extracted in real-time. Basing on these extracted data the pan/tilted-imbedded stereo camera system is adaptively controlled and as a result, the proposed system can track the target adaptively under the various circumstance of the target. From some experiments using 480 frames of the test input stereo image, it is analyzed that a standard variation between the measured and computed the estimated target's height and an error ratio between the measured and computed 3D coordinate values of the target is also kept to be very low value of 1.03 and 1.18$\%$ on average, respectively. From these good experimental results a possibility of implementing a new real-time intelligent stereo target tracking and surveillance system using the proposed scheme is finally suggested.

Accuracy and Reliability of The Spine-Pelvis Monitor to Record Three-Dimensional Characteristics of The Spine-Pelvic Motion

  • Kim, Jung-Yong;Yoon, Kyung-Chae;Min, Seung-Nam;Yoon, Sang-Young
    • Journal of the Ergonomics Society of Korea
    • /
    • v.31 no.2
    • /
    • pp.345-352
    • /
    • 2012
  • Objective: The aim of this study is to evaluate the accuracy and reliability of Spine-Pelvis Monitor(SPM) that was developed to measure 3-dimensional motion of spine and pelvis using tilt sensor and gyro sensor. Background: The main cause of low back pain is very much associated with the task using the low back and pelvis, but no measurement technique can quantify the both spine and pelvis. Method: For testing the SPM, 125 angles from three anatomical planes were measured three times in order to evaluate the accuracy and reliability. The accuracy of SPM in measuring dynamic motion was evaluated using digital motion analysis system. The motion pattern captured by two measuring methods was compared with each other. In result, the percentage error and Cronbach coefficient alpha were calculated to evaluate the accuracy and reliability. Results: The percentage error was 0.35% in flexion-extension on sagittal plane, 0.43% in lateral bending on coronal plane, and 0.40% in twisting on transverse plane. The Cronbach coefficient alpha was 1.00, 0.99 and 0.99 in sagittal, coronal and transvers plane, respectively. Conclusion: The SPM showed less than 1% error for static measurement, and showed reasonably similar pattern with the digital motion system. Application: The results of this study showed that the SPM can be the measuring method of spine pelvis motion that enhances the kinematic analysis of low back dynamics.

Geometric Errors Estimation of a Rotary Table using Double Ball-bar (볼바를 사용한 회전 테이블의 기하학적 오차 추정)

  • Lee, Kwang-Il;Lee, Dong-Mok;Kweon, Sung-Hwan;Yang, Seung-Han
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.27 no.11
    • /
    • pp.98-105
    • /
    • 2010
  • In this paper, double ball-bar is used to estimate the geometric errors of a rotary table, which includes one-axial motion, two-radial motions and two-tilt motions, except the angular positioning error. To simplify the measurement procedures, three measurement steps have been designed and developed. At each measurement step, one end of the double ball-bar is fixed at the nose of spindle and the other end is located on the rotary table. And specific circular test path is planned to keep the distance between two balls as constant at ideal case. The relationship including the geometric errors of a rotary table and the measured distance between two balls which is distorted by the geometric errors is defined by using ball-bar equation. Each geometric error is modeled as $4^{th}$ order polynomial considering $C^1$-continuity. Finally the coefficients of polynomial are calculated by least-square method. Simulation is done to check the validation of the suggested method considering set-up errors and measurement noise. Suggested method is applied to estimate geometric errors of a rotary table of a 5-axis machine tool.

Coupling loss variation as the shape of fiber ends and the fiber arrangement in a fiber Fabry-Perot filter (광섬유 Fabry-Perot필터에서 광섬유 단면의 모양과 배치에 따른 결합손실 변화)

  • 김종호;예윤해
    • Korean Journal of Optics and Photonics
    • /
    • v.8 no.3
    • /
    • pp.230-235
    • /
    • 1997
  • Coupling loss variation as the shape of fiber ends and the fiber arrangement in a fiber Fabry-Perot cavity, formed with two optical fibers with dielectric mirror coatings on their ends, is analyzed. For the intended features it is assumed that one of two fibers is processed to have a concave mirror whose curvature is the same as that of the wavefront of the Gaussian beam from the first fiber. In this assumption, it was turned out that the coupling loss at the cavity length of 15 ${\mu}{\textrm}{m}$ is less than 0.5% even with tilt angle of 0.2$^{\circ}$, curvature error of 70 ${\mu}{\textrm}{m}$, cavity length error of 8 ${\mu}{\textrm}{m}$, and lateral alignment error of 0.5 ${\mu}{\textrm}{m}$. Thus, low loss and high-finesse fiber Fabry-Perot filters whose cavity length is greater than several ${\mu}{\textrm}{m}$ can be obtained easily if the receiving fiber end is properly formed.

  • PDF

Study of the Reflector Shape of a Test Lamp for a Flame Detector with Little Influence of Error in Optical-system Fabrication (광학계 제작 시 오차 영향이 적은 불꽃감지기용 테스트램프 반사경 형상에 관한 연구)

  • Park, Hye-Jin;Kang, Dong-Hwa;Kong, Mi-Seon;Kim, Eun-Ji;Lee, Ye-Eun;Jo, Ye-Ji;Jung, Mee-Suk
    • Korean Journal of Optics and Photonics
    • /
    • v.29 no.6
    • /
    • pp.233-240
    • /
    • 2018
  • In this paper, a design method to reduce fabrication errors in reflector shape of a test lamp for a flame detector is carried out. Although the test lamp should be operated in parallel with a high-intensity light, it is difficult to fix the small reflector that controls the central light during fabrication. To solve these problems, a small spherical reflector is designed to minimize the performance degradation for a light loss factor of less than 5%, even during tilt and decenter, and a spherical shape is proposed for a small reflector with little effect on the error when designing the optical system.