• Title/Summary/Keyword: tilt

Search Result 1,718, Processing Time 0.03 seconds

Flow Analysis around Tilt-rotor Aircraft at Various Tilt Angles (틸트각 변화에 따른 틸트로터 항공기 주위의 유동해석)

  • Kim, Su-Yean;Choi, Jong-Wook
    • Journal of the Korean Society of Visualization
    • /
    • v.9 no.2
    • /
    • pp.40-47
    • /
    • 2011
  • Tilt-rotor aircraft can be used in various fields because they have the capabilities of the vertical take-off and landing and the high-speed cruise flight. In the present study, the flow analysis of a tilt-rotor aircraft is conducted at various tilt angles. The lift and drag forces of the tilt-rotor aircraft are obtained and the wakes by the rotor-blade are visualized. The result shows that the rotor-blade affects the lift force in a hovering mode and the main wing has an influence on the lift force in a cruise mode. Additional thrust is required at the tilt angle of around 40 degree due to the least lift force. The drag force is dependent on the rotor-blade at overall tilt angles. The minus drag force appears between the tilt angles of 90 degree and 55 degree. Also, the drag force is dramatically increased at the other tilt angles. The wake by rotor-blade affects the flow around the fuselage of the tilt-rotor aircraft at the tilt angles of 75 degree and 60 degree.

A study on the stabilization and controller design for directional pan-tilt system (지향성 Pan-Tilt 시스템의 안정화와 제어기 설계에 관한 연구)

  • Shin, Suk-Shin;Noh, Jong-Ho;Park, Jong-Ho
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.37 no.2
    • /
    • pp.192-198
    • /
    • 2013
  • This paper presents the stabilization and design of a pan-tilt control part for the directional pan-tilt system for shipboard directional equipment. In order to control each control axis with compensation for ship motion, the 2 degree of freedom(2DOF) PID controller is designed and its parameters are tuned using a real-coded genetic algorithm(RCGA). Simulation demonstrates the effectiveness of the 2 DOF PID controller tuning.

Biomechanical changes in lower quadrant after manipulation of low back pain patients with sacroiliac joint dysfunction (요통환자의 엉치엉덩관절 기능부전에 대한 도수교정 후에 하지의 생체역학적인 변화)

  • Oh, Seung-Gil;Yoo, Seung-Hee
    • Journal of Korean Physical Therapy Science
    • /
    • v.8 no.1
    • /
    • pp.893-906
    • /
    • 2001
  • The purposes of this study were to compare pelvic tilt. range of motion(ROM) of hip rotation, and leg length difference before and after manipulation and to investigate correlation between changes of each variables after manipulation of sacroiliac pint in 31 low back pain patients(11 males, 20 females) with sacroiliac pint dysfunction. The sacroiliac pint of patients was manipulated on the side of anterior pelvic tilt, using the technique described by Stoddard(1962) and Greenmann (1996). I used this technique because it usually eliminated sacroiliac Pint dysfunction in one treatment session. SPSS for window computer system was used to analyze the data. Also t-test was performed for comparison of the variables before and after manipulation, and Pearson product-moment correlation analysis and regression analysis were performed for changes of each variables after manipulation. The result were as follows: 1. The pelvic tilt after manipulation was significantly decreased(mean=$2.79^{\circ}$) compared with the pelvic tilt before manipulation(p=.001). 2. The PROM of hip internal rotation ipsilateral to anterior pelvic tilt after manipulation significantly decreased (mean = $1.88^{\circ}$) compared with hip internal rotation before manipulation (p=.008). The PROM of hip internal rotation ipsilateral to posterior pelvic tilt after manipulation significantly increased(mean = $1.29^{\circ}$) compared with hip internal rotation before manipulation (p=.029). 3. The PROM of hip external rotation ipsilateral to anterior pelvic tilt after manipulation significantly increased(mean=$2.42^{\circ}$) compared with the hip external rotation before manipulation(p=$2.42^{\circ}$) compared with the hip external rotation ipsilateral to posterior pelvic tilt after manipulation significantly decreased(mean = $1.84^{\circ}$) compared with the hip external rotation before manipulation (p=.008). 4. Leg length difference after manipulation significantly decreased(mean=2.15 mm) compared with leg length difference before manipulation (p=.008). Regression analysis revealed that a fair correlation was found between change in leg length difference and change in anterior pelvic tilt after manipulation(p=.009). 5. Pearson product-moment correlation coefficient was used to assess differences of the variables after manipulation. A fair correlation was found between change in leg length difference and change in anterior pelvic tilt after manipulation(r=.462, p<.01). A fair correlation was found between change in anterior pelvic tilt and change in hip internal rotation ipsilateral to anterior pelvic tilt(r=.397, p<.05) and between change in anterior pelvic tilt and change in hip external rotation ipsilateral to anterior pelvic tilt(r=.516, p<.01). A fair correlation was found between change in posterior pelvic tilt and changes in hip internal rotation ipsilateral to posterior pelvic tilt (r=.441, p<.05) and between change in posterior pelvic tilt and change in hip external rotation ipsilateral to posterior pelvic tilt(r=.361, p<.05). A fair correlation was found between change in hip internal rotation ipsilateral to anterior pelvic tilt and change in hip external rotation ipsilateral to posterior pelvic tilt(r=.388, p<.05) and between change in hip internal rotation ipsilateral to posterior pelvic tilt and change in hip internal rotation ipsilateral to anterior pelvic tilt(r=.426. p<.05).

  • PDF

Sex Difference in the Range of Pelvic Tilt in Sitting and Standing Among Korean Young Adults

  • Yoon, Jangwhon
    • Physical Therapy Korea
    • /
    • v.27 no.2
    • /
    • pp.149-154
    • /
    • 2020
  • Background: The range of pelvic tilt is one of modifiable risk factors in preventing the lower back pain. Objects: The purpose of this study were to compare the range of pelvic tilt motion by testing position and sex. Methods: One hundred five young adults (61 females and 44 males) agreed to participate in measuring the anterior and posterior pelvic tilt with the PALM (Palpation Meter) in sitting and standing. The range of pelvic tilt motion was defined as the difference between the pelvic anterior and posterior tilt angles. Results: In general, the anterior pelvic tilt was greater (p < 0.01) in standing than in sitting and the posterior pelvic tilt was lesser (p < 0.01) in sitting than in standing. The anterior pelvic tilt in sitting and standing was greater (p < 0.01) in the females than in the males. However, the effect of sex on the posterior pelvic tilt was only significant in sitting (p < 0.01), but not in standing (p = 0.78). The range of pelvic tilt was greater (p = 0.03) in sitting but not significantly (p = 0.07) affected by the sex. Conclusion: The pelvic tilt motion in these young adults showed large variability and further studies are needed to understand better its relationship to the prevalence of the lower back disorders.

Study of Capacitive Tilt Sensor with Metallic Ball

  • Lee, Chang Hwa;Lee, Seung Seob
    • ETRI Journal
    • /
    • v.36 no.3
    • /
    • pp.361-366
    • /
    • 2014
  • In this paper, a new, simple capacitive tilt sensor with a metallic ball is proposed. The proposed tilt sensor has only two electrodes and a metallic ball, and this design assists in managing the inherent contact problem in measuring tilt angles. Capacitive sensing, compared with other types of tilt sensor, has many advantages such as simplicity, noncontact measurement, long-throw linear displacement, and sub-micron plate spacing. Its design and fabrication process are significantly simpler than previous types of tilt sensors. The dimensions of the prototype tilt sensor are $20mm{\times}20mm$, and the diameter of the polystyrene tube is 5 mm with a tube thickness of 0.15 mm. An analytical study of the prototype capacitive tilt sensor was undertaken, and the experimental results demonstrate the relationship between the tilt angles and measured capacitances compared with the analytical study.

Tilt Measurement of Lens Module with Multiple Lenses : Algorithm and Application (다중 렌즈 모듈의 기울기 측정 : 이론 및 응용)

  • Lee, Seung-Hee;Park, Jong-Hyeon
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.31 no.3 s.258
    • /
    • pp.395-402
    • /
    • 2007
  • This paper considers about the tilt measurement of lens module with multiple lenses. The tilt between lenses in lens module and barrel or between image sensor and barrel can be measured precisely with the proposed algorithm. The magnitude and direction of the tilt vector of lens and image sensor can be measured from the best focal surface. The selecting and setting of image sensor, test chart, image sensor centering to lens module, axis align, focus measure method are also explained to get highly precise tilt results. The proposed algorithm is verified with the lens module inspection system we developed, and the experimental results show that the tilt measure proposed in this paper is robust and precise. With the proposed tilt measurement algorithm, the tilt of an image sensor and any other lens which intermediates light can be measured.

Comparison of Tilt Variation in the Otter Board and Codend of Bottom Trawl Gear during Fishing Operations

  • Kim, Yong-Hae
    • Fisheries and Aquatic Sciences
    • /
    • v.17 no.1
    • /
    • pp.145-153
    • /
    • 2014
  • The motion of the otter board on a trawl can affect the motion of trawl nets, and the motion of the codend can affect fish selectivity. Preliminary measurements of the tilt of bottom trawl gear were carried out to compare the tilts of the otter board and codend. The tilt of the otter board was measured by Vector and tilt at 1.5 m anterior to the end of the codend, and the middle upper panel was measured with a micro-DST-tilt logger. Tilt data such as yaw, pitch, and roll were analyzed by the fast Fourier transformation method and global wavelet and event analyses for the period or amplitude. The mean period ${\pm}$ standard deviation of the tilt in the otter board, $(5-6){\pm}2s$, was similar to the period of the codend, $(4-6){\pm}(2-3)s$, whereas the amplitude of the codend was greater than that of the otter board. The yaw and pitch periods were not significantly different between the otter board and codend, but roll was different. Furthermore, the tilt period frequencies of the otter board and codend were not significantly different. Accordingly, the tilt motion of the codend was mostly related to the tilt of the otter board.

Effects of Passive Scapular Postural Correction and Active Scapular Posterior Tilt Strategies on Peri-scapular Muscle Activation (수동적 어깨뼈 자세 교정 전략과 능동적 어깨뼈 뒤쪽 기울임 전략이 어깨뼈 주변근육 활성도에 미치는 영향)

  • Kang, Min-Hyeok
    • PNF and Movement
    • /
    • v.20 no.2
    • /
    • pp.215-222
    • /
    • 2022
  • Purpose: The purpose of this study was to compare the effects of passive scapular upward rotation and posterior tilt and active scapular posterior tilt on the muscle activity of the upper trapezius (UT), lower trapezius (LT), and serratus anterior (SA). Methods: Fifteen healthy subjects performed general arm elevation, arm elevation with passive scapular upward rotation and posterior tilt, and arm elevation with active scapular posterior tilt. For active scapular posterior tilt, the subjects were trained in this movement using visual biofeedback and a motion sensor. During each arm elevation condition, electromyography was used to measure the muscle activity of the UT, LT, and SA. The measured data were analyzed using a one-way repeated ANOVA. Results: LT muscle activity was significantly increased during arm elevation with active scapular posterior tilt compared to both general arm elevation and arm elevation with passive scapular upward rotation and posterior tilt (p < 0.05). SA muscle activity was greater during arm elevation with passive scapular upward rotation and posterior tilt than during general arm elevation (p < 0.05). There was no significant change in UT muscle activity among the tested arm elevation conditions (p > 0.05). Conclusion: Performing arm elevation with active scapular posterior tilt and performing arm elevation with passive scapular upward rotation and posterior tilt may be useful strategies for increasing muscle activation of the LT and SA, respectively.

Difference of Muscle Activity by Pelvic Tilt in Side-Lying Hip Abduction

  • Kim, Hae-Joong;Lee, Han-Suk;Jung, Hyung-Gook
    • Journal of the Korean Society of Physical Medicine
    • /
    • v.12 no.3
    • /
    • pp.59-66
    • /
    • 2017
  • PURPOSE: This study was to evaluate the muscle activity of gluteus medius, tensor fascia latae, and quadratus lumborum during side-lying abduction exercise in various pelvic tilting positions. METHODS: We measured the activity of three muscles in three pelvic tilt positions for 17 normal subjects with performing the side-lying hip abduction. Three pelvic tilt positions were posterior tilt, neutral tilt and anterior tilt. We used the mean value after participants performed the hip abduction three times each position. RESULTS: The activity of gluteus medius within three pelvic positions showed the highest activity in pelvic posterior tilt position and the lowest in pelvic neutral tilt position (p = .04). The activity of tensor fascia latae showed the lowest in pelvic posterior tilt position and the highest in pelvic posterior tilt position (p = .00). The activity of quadratus lumborum revealed the lowest activity in pelvic neutral tilt position and the highest in pelvic anterior tilt position (p = .00). The activity of selective gluteus medius activation according to pelvic displacement showed the highest activity in pelvic neutral tilt position and lowest in pelvic anterior tilt position (p = .00). CONCLUSION: Hip abduction with Pelvic posterior tilt position may be effective in increasing gluteus medius and may be effective in strengthening exercise program for the gluteus medius. In addition, Hip abduction with pelvic neutral position may have an effect on the selective gluteus medius, which is considered to be effective in the exercise program for muscle reeducation training of the gluteus medius.

The Calculation on the Optimum Angle of Tilt Type Window by Length of Transmitted Solar Radiation (투과일사의 유입길이에 따른 Tilt 창호의 적정 기울기 산정)

  • Cho, Sung-Woo
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.22 no.9
    • /
    • pp.635-640
    • /
    • 2010
  • This study is suggested tilt window type to be restrained solar radiation through vertical window type in buildings. The shading and aesthetical effect of buildings would be solved by installation of tilt window type. For investigate optimum an angle of tilt window and building azimuth in reference region, the distance of transmitted solar radiation is calculated. The results of calculation showed optimum an angle of tilt window is obtained $7^{\circ}$ that the distance of transmitted solar radiation is 20% of 1.5m of balcony width. In case of an tilt window angle of $7^{\circ}$, the optimum building azimuth is showed $SW15^{\circ}{\sim}SE15$.