• 제목/요약/키워드: tight measure

검색결과 35건 처리시간 0.024초

On Normalized Tight Frame Wavelet Sets

  • Srivastava, Swati
    • Kyungpook Mathematical Journal
    • /
    • 제55권1호
    • /
    • pp.127-135
    • /
    • 2015
  • We determine two-interval normalized tight frame wavelet sets for real dilation $d{\in}(1,{\infty})$, and characterize all symmetric normalized tight frame wavelet sets. We also construct a normalized tight frame wavelet set which has an infinite number of components accumulating at the origin. These normalized tight frame wavelet sets and their closures possess the same measure. Finally an example of a normalized tight frame wavelet set is provided whose measure is strictly less than the measure of its closure.

Iliotibial Band Stretching in the Modified Thomas Test Position Changes Hip Abduction Angle and Vastus Medialis Activity in Individuals With Tight Iliotibial Band

  • Baik, Seung-min;Jeong, Hyo-jung;Lee, Ji-hyun;Park, Dong-hwan;Cynn, Heon-seock
    • 한국전문물리치료학회지
    • /
    • 제26권1호
    • /
    • pp.75-83
    • /
    • 2019
  • Background: A tight iliotibial band (ITB) may lead to lateral patellar maltracking, compression, and tilt, and dominant vatus lateralis (VL) muscle activation relative to vastus medialis oblique (VMO) can laterally displace the patella, which leads to anterior knee pain. Therefore, an effective management technique is needed to stabilize the patella in individuals with tight ITB. Increased stability during the modified Thomas test has the potential to decrease compensatory motion and thus to selectively stretch the ITB. Objects: The purpose of this study was to determine the effects of ITB stretching in the modified Thomas test position on ITB flexibility, patellar translation, and muscle activities of the VMO and VL during quadreceps-setting (QS) exercise in individuals with tight ITB. Methods: Twenty-one subjects with tight ITB were recruited. Digital inclinometer was used to measure the hip adduction angle during the modified Ober test. Universal goniometer was used to measure the hip abduction angle during the modified Thomas test. Ultrasonography was used to measure the patella-condylar distance. Electromyography was performed to collect data of muscle activities. Paired t-test was used to determine the statistical significance between pretest and posttest. Results: The range of hip adduction in modified Ober test increased (p=.04) and the range of hip abduction in the modified Thomas test decreased after ITB stretching (p<.01). There was no difference between lateral patellar translation (p=.18). VMO muscle activity significantly increased after ITB stretching during QS (p<.01). VL muscle activity had no difference after stretching. Conclusion: The ITB stretching in the modified Thomas test position can be suggested as a management method for improving ITB flexibility and VMO muscle activity in individuals with tight ITB.

심전도 측정을 위한 밀착 의복 연구 -패턴 축소 및 주관적 평가를 중심으로- (Development of Tight-fitting Upper Clothing for Measuring ECG -A Focus on Weft Reduction Rate and Subjective Assessment-)

  • 정연희;양영모
    • 한국의류학회지
    • /
    • 제36권11호
    • /
    • pp.1174-1185
    • /
    • 2012
  • This study develops tight-fitting upper clothing to measure electrocardiography (ECG) data. Taking into consideration the elasticity of the clothing, we made 4 experimental clothes by applying to each a weft reduction rate of 40%, 50%, 60%, and 70%. The 4 experimental clothes were used to measure resting ECG, exercise ECG, and post-exercise ECG for 4 men in their 20s. We compared clothing pressures using sensors on the human body and on a dressform. Subjective wear sensations of the 4 experimental clothes were evaluated using a subjective 7-point scale (with 7 being most excellent). We measured clothing pressures by using the air type pressure (AMI 3037-2) for upper and lower chest sensors in the developed tight-fitting upper clothing. The lower chest sensor showed that the clothing pressure on a human body and dressform changed consistently as the weft reduction rate decreased. The upper chest sensor showed inconsistent changes in clothing pressure as the weft reduction rate decreased. The wearing-test result for preliminary subjects showed that the lower chest sensor was more stable than the upper chest sensor; therefore, we inserted the sensor at the lower chest position before performing ECG. Except for Subject 4, the resting ECGs were stably measured for 3 subjects (Subject 1, Subject 2, and Subject 3) in all the developed clothes (A clothing, B clothing, C clothing, and D clothing). However, D clothing showed stable ECG values after exercise. The results of the experiment showed that we could measure ECG without difficulty using clothes with a weft reduction rate of 40% when the movement was not intense; however, tight-fitting upper clothing with a weft reduction rate of 70% was necessary to measure exercise ECG and post-exercise ECG values.

Use of High-Temperature Gas-Tight Electrochemical

  • Park, Jong-Hee;Beihai Ma;Park, Eun-Tae
    • The Korean Journal of Ceramics
    • /
    • 제4권2호
    • /
    • pp.103-113
    • /
    • 1998
  • By using a gas-tight electrochemical cell, we can perform high-temperature coulometric titration and measure electronic transport properties to determine the elecronic defect structure of metal oxides. This technique reduces the time and expense required for conventional thermogravimetric measurements. The components of the gas-tight coulometric titration cell are an oxygen sensor, Pt/yttria stabilitized zirconia(YSZ)/Pt, and an encapsulated metal oxide sample. Based on cell design, both transport and thermodynamic measurements can be performed over a wide range of oxygen partial pressure ($pO_2=10^{-35}$ to 1 atm). This paper describes the high-temperature gas-tight electrochemical cells used to determine electronic defect structures and transport properties for pure and doped-oxide systems, such as YSZ, doped and pure ceria $(Ca-CeO_2 \;and\; CeO_2)$, copper oxides and copper-oxide-based ceramic superconductors, transition metal oxides, $SrFeCo_{0.5}O_x,\; and \;BaTiO_2$.

  • PDF

입체 재단법에 의한 Tight Fitting시 등폭 기준선의 설정에 관한여 (On the Fixing of the Shoulder Blade Level during Tight Fitting by the Draping Design)

  • 이순섭
    • 복식문화연구
    • /
    • 제4권3호
    • /
    • pp.373-381
    • /
    • 1996
  • Draping design system organized by European about 13C has been developed greatly for a long while, but for the purpose of the practical use the Dress form similar to human body has been needed. In order to make three-dimensional effect as fitting Muslin ot the Dress form. the Basic lien has to be established in Muslin and Dress form each. At this time, Shoulder-blade level is indicated from various angles : measure down 10cm from the back neck point, a quarter of the back neck point to the waist lie, the half-way point between neckline and bust line, measure down 41 inches from the back neck line, measure down 3 inches from the top edge of the muslin at center back and cross mark for neck line, and so forth. This study established the Basic line through the two ways of them (B.N.P∼B.L/2, B.N.P∼W.L/4), did tight fitting to the 5 kinds of Dress forms which ar normal type in the drop value(the difference between hip circumference and bust circumference), and acquired Basic Pattern. After the experiment, fitness are throughly investigate by statistical analysis of measurements. As a result, this study finds out that fit is proper when shoulder blade level is situated on a fourth of the back neck point to the waist line and a quarter point between back neck point and waist line, and waist dart is situated on the back center line and princess line.

  • PDF

휴대용 심전도 기기와 직물형 전극을 이용한 생체정보 측정용 밀착 의복 개발 (Development of Tight-Fitting Garments with a Portable ECG Monitor to Measure Vital Signs)

  • 정연희;김승환;양영모
    • 한국의류학회지
    • /
    • 제34권1호
    • /
    • pp.112-125
    • /
    • 2010
  • A Holter monitor is used for ECG monitoring of ambulatory daily life in hospital. However, the use of this apparatus causes skin allergies and discomfort in patients because of the attachment gel and tapes used to attach disposable electrodes to the skin. In this study, the development of tight-fitting clothing connected to a portable Holter monitor was proposed. In addition, the use of conductive fabrics as electrodes was proposed; this will enable the use of garments in u-health care for measuring ECG signals. The male subjects were university students in the ages of 20 to 24. Subjective wear sensations of the experimental garments were rated using seven Likert scales. A Likert type scale was used for the evaluation and a 7 point score indicates that it provided the best fit as a tight-fitting upper clothing. Clothing pressure was measured using an air-pack-type pressure sensor (model AMI 3037-2) at 4 locations (the conductive fabric electrode) As results, a male basic sloper for upper clothing was developed and that pattern was manipulated to the tight fit pattern by considering the reduction rate of the percentage stretch in the fabric. The developed tight-fitting garment was superior in terms of subjective sensation and 6t. The mean pressure of the garment with reduction rates of 40% in width and of 50% in length was 8.45gf/$cm^2$. A conductive fabric electrode was developed by considering the sewing method and the developed electrode was detected well. The ECG data were recorded for 13 hr 19 min 44 sec and the artifacts in the ECG signals were recorded for 9 hr 3 min 46 sec (total time: 22 hr 23 min 23 sec). The artifacts data were obtained during heavy activities.

인간 대장상피세포 밀착연접 형성과정에서 NQO1 저해 효과 (Inhibition of NAD(P)H:Quinone Oxidoreductase 1 by Dicumarol Reduces Tight Junction in Human Colonic Epithelial Cells)

  • 훙지;장펑;윤이나;김호
    • 생명과학회지
    • /
    • 제26권5호
    • /
    • pp.531-536
    • /
    • 2016
  • 본 연구는 최근 연구자 등이 보고한 NQO1 knockout (결핍) 생쥐의 점막기능 감소 및 장염유발 현상을 인간 대장상피세포에서 재확인하는 것이다. 이를 위해, 사람 대장상피세포주인 HT29 세포에 NQO1 억제제인 dicumarol을 처치한 다음 밀착연접 조절인자의 변화를 평가하였다. HT29 세포에 10 μM dicumarol을 처치하여 NQO1을 억제하면 인간 대장상피세포의 밀착연접이 유의하게 줄고 구성인자들(ZO1, occludin)의 단백질 양도 감소함을 확인하였다. 생쥐 대장 내강에 dicumarol (10 μM)을 직접 처치한 결과 점막 투과율이 현저하게 증가함도 확인하였다(장벽기능 감소). 이는 인간 대장상피세포의 밀착연접 형성과정이 NQO1에 의존적임을 보여준다. 그러나 dicumarol 처치는 ZO1과 occludin의 전사량을 억제하지 않았다. NOQ1 결핍 생쥐에서 ZO1과 occludin의 전사량이 크게 감소한다는 이전 보고를 감안하면, NQO1에 의한 밀착연접 단백질의 양적 조절 과정이 전사를 포함하는 다양한 경로와 연관되어 있음을 시사한다. 즉, NQO1에 의한 ZO1과 occludin 조절 과정에 프로테오좀 의존-단백질 변성과 같은 단백질 파괴 경로가 이용될 수 있다고 사료된다.

의복설계를 위한 성인여성의 경부형태의 관찰 I - 도형의 자동제도를 위한 3차원 계측지의 처리방법 - (Observation on Neck Form of Young Japanese Women for Clothing Design I - A Method for Approximate Development of 3-D Measure Valuses -)

  • 최영옥
    • 복식
    • /
    • 제31권
    • /
    • pp.89-99
    • /
    • 1997
  • In order to know what sorts of features of neck fore may be required to make plans for tight fitting collars the neck form of young japanese women were measured three deme-nsionally using. GRASP(Grating projection System for Profiling) and plaster torso. The following results were obtained: 1. We could be known the features of neck form for tight fitting collars by using both plaster torso method and GRASP method. 2. By the BASIC language in NEC computer and EXCEL package program in macin-TOSHI computer it became possible to draft a numble of neck surface automatically there-fore we got analysis of a mass of subjects.

  • PDF

Quasi real-time post-earthquake damage assessment of lifeline systems based on available intensity measure maps

  • Torbol, Marco
    • Smart Structures and Systems
    • /
    • 제16권5호
    • /
    • pp.873-889
    • /
    • 2015
  • In civil engineering, probabilistic seismic risk assessment is used to predict the economic damage to a lifeline system of possible future earthquakes. The results are used to plan mitigation measures and to strengthen the structures where necessary. Instead, after an earthquake public authorities need mathematical models that compute: the damage caused by the earthquake to the individual vulnerable components and links, and the global behavior of the lifeline system. In this study, a framework that was developed and used for prediction purpose is modified to assess the consequences of an earthquake in quasi real-time after such earthquake happened. This is possible because nowadays entire seismic regions are instrumented with tight networks of strong motion stations, which provide and broadcast accurate intensity measure maps of the event to the public within minutes. The framework uses the broadcasted map and calculates the damage to the lifeline system and its component in quasi real-time. The results give the authorities the most likely status of the system. This helps emergency personnel to deal with the damage and to prioritize visual inspections and repairs. A highway transportation network is used as a test bed but any lifeline system can be analyzed.

박판성형시 컬 예측모델 개발(I)-해석적 모델 (Development of Prediction Model for Sidewall Curl in Sheet Metal Forming(I)-Analytical Model)

  • 주병돈;박현규;김동우;문영훈
    • 소성∙가공
    • /
    • 제16권6호
    • /
    • pp.432-437
    • /
    • 2007
  • Sidewall curl is the curvature that results from non-uniform through-thickness strain present in the sheet stamping process which involves material flow over a die radius. In order to understand and control sidewall curl for tight fit-up tolerances, an analytical model that can provide a reliable measure for the amount of curl would be very helpful. In this study, a model is developed based on the moment-curvature relationship during bending-under-tension operations. The analytical model includes the variables of applied tensile force, the yield strength, the elastic modulus, the bending radius, and the sheet thickness, which are the primary factors affecting sidewall curl during sheet stamping operations. For the accuracy of analytical model, six possible deformation patterns are proposed on the basis of material properties and bending geometries.