• Title/Summary/Keyword: thyroid imaging

Search Result 159, Processing Time 0.02 seconds

Sonographic Assessment of the Extent of Extrathyroidal Extension in Thyroid Cancer

  • Sae Rom Chung;Jung Hwan Baek;Young Jun Choi;Tae-Yon Sung;Dong Eun Song;Tae Yong Kim;Jeong Hyun Lee
    • Korean Journal of Radiology
    • /
    • v.21 no.10
    • /
    • pp.1187-1195
    • /
    • 2020
  • Objective: This study aimed to determine the sonographic features suggestive of extrathyroidal extension (ETE) of thyroid cancers. Materials and Methods: We retrospectively reviewed the sonographic images of 1656 consecutive patients who had undergone thyroidectomy in 2017. The diagnostic performance of sonographic features suggestive of ETE was evaluated using operation and histopathologic reports. Sonographic features for gross ETE to the strap muscle and minor ETE were assessed for thyroid cancer abutting the anterolateral thyroid capsule. Sonographic features for tracheal invasion were assessed according to whether the angle between the tumor and the trachea was an acute, right, or obtuse angle. Sonographic features for recurrent laryngeal nerve (RLN) invasion were assessed based on the association between the tumor and tracheoesophageal groove (TEG) as preserved normal tissue, abutting or protruding into the TEG. Results: ETE was observed in 783 patients (47.3%), including 123 patients with gross ETE (7.4% [strap muscle, n = 97; RLN, n = 24; and trachea, n = 14]) and 660 patients with minor ETE (39.9%). Regarding the diagnosis of gross and minor ETE to the strap muscle, sonographic features of replacement of the strap muscle and capsular disruption showed the highest positive predictive value (75.9% and 58.5%, respectively). Thyroid cancer forming an obtuse angle with the trachea had the highest sensitivity for the diagnosis of tracheal invasion (85.7%), and thyroid cancer protrusion into the TEG showed the highest sensitivity for the diagnosis of RLN (83.3%). Conclusion: Sonography is considered beneficial in the diagnosis of ETE to the strap muscle, trachea, and RLN. Assessment of ETE is important for the accurate staging of thyroid cancer, which in turn determines the extent of surgery or whether active surveillance is appropriate or not.

A Case Report on Papillary Thyroid Cancer for the Recurrence of Regional Cervical Lymph Nodes improved by Korean medicine (갑상선 유두암으로 수술 후 좌우 림프절 전이 환자의 장기간 복합 한의약 치료 증례보고)

  • Hae-won, Lee;Soo-bin, Lee;Hye-won, Kim;Jin-Gu, No;Hye In, Jeong;Jun-Hyoung, Kim;Kyeong Han, Kim
    • Journal of Society of Preventive Korean Medicine
    • /
    • v.26 no.3
    • /
    • pp.29-40
    • /
    • 2022
  • Objective : This study assessed the effect of a combination of Korean medicine on a thyroid papillary cancer patient who was diagnosed with local lymph node metastasis after thyroidectomy and lymph node dissection but did not want surgery. Methods : Gami-Palmultang administration and moxibustion(large Bmoxa cautery) were performed for six years. Treatment outcomes were evaluated with Brief Fatigue Inventory (BFI), Numerical Rating Scale (NRS), Insomnia Severity Index (ISI), Functional Assessment of Cancer Therapy-General (FACT-G), blood test/ CT imaging results, and patient's statements. Results : After the treatment, all symptoms have been alleviated, the quality of life has increased, and it has been maintained without further metastasis of tumors for six years. Conclusion : Korean medicine treatment along with active observation can be an alternative to patients who do not want surgical treatment after recurrence of local lymph nodes in thyroid papillary cancer, and can have positive results in improving the quality of life.

Comparison of $Na^+/I^-$ Symporter Expression Rate in Malignant and Benign Thyroid Diseases: Immunohistochemical Study (악성 및 양성 갑상선 질환의 조직에서 면역조직학적 검사법에 의한 $Na^+/I^-$ symporter의 발현율 비교)

  • Kang, Do-Young;Jeong, Young-Jin;Lee, Kyung-Eun;Park, Heon-Soo;Yoo, Young-Hyun;Roh, Mee-Sook
    • Nuclear Medicine and Molecular Imaging
    • /
    • v.40 no.1
    • /
    • pp.9-15
    • /
    • 2006
  • Purpose: Previous studies have not showed consistent results for the level of expression of sodium/iodide symporter (NIS) in thyroid diseases, especially malignant tumor. We undertook this study to evaluate the distribution of NIS expression in malignant thyroid diseases and compare with that in benign thyroid disease. Materials and Methods: Total patients were 119 cases (Men 15, $48{\pm}13$ yrs). Total number of samples were 205 pieces. In malignant thyroid disease, there were 153 samples: 90 in papillary carcinoma, 4 in follicular carcinoma, 2 in medullary carcinoma and 57 in metastatic lymph node. In benign thyroid disease, there were 52 samples: 36 in goiter/cyst, 11 in thyroiditis and 5 in follicular adenoma. Using immunohistochemical methods, we probed 205 samples with monoclonal anti-NIS Ab. Grading of staining was stored as 0 (negative or absent), 1 (weakly positive), 2 (moderately positive) or 3 (strongly positive). Expression rate (ER) of NIS positivity in individual disease entity was expressed as percentage of total number divided by number in 2 plus 3 grade. Results: ERs of malignant thyroid diseases were 63% in papillary carcinoma, 81% in metastatic lymph node, 71% in follicular carcinoma and 100% in medullary carcinoma. ERs of benign thyroid disease were 53% in goiter/cyst, 64% in thyroiditis and 40% in follicular adenoma. ER of malignant thyroid diseases was higher than benign thyroid diseases (71% vs 54%). Grading of NIS expression in papillary carcinoma or goiter/cyst was heterogeneously distributed in considerable cases. Normal tissue also showed heterogeneous distribution of NIS expression, which was not correlated with that of primary lesion. Conclusion: In papillary thyroid carcinoma, distribution of NIS expression was heterogeneous and increased, and not different compared with that of benign thyroid disease.

Coded Aperture Gamma Camera for Thyroid Imaging: Monte Carlo Simulation (갑상선 영상 획득을 위한 부호화 구경 감마카메라: 몬테칼로 시뮬레이션 연구)

  • Beak, Cheol-Ha;Lee, Seung-Jae;Chung, Yong-Hyun
    • Progress in Medical Physics
    • /
    • v.19 no.4
    • /
    • pp.247-255
    • /
    • 2008
  • A coded aperture camera has been developed to improve the signal-to-noise ratio (SNR) while keeping the spatial resolution of a pinhole gamma camera. The purpose of this study was to optimize a coded aperture camera and to evaluate its possibility for thyroid imaging by Monte Carlo simulation. A clinical gamma camera, a pinhole collimator with 1.0 mm hole diameter, and a $79{\times}79$ modified uniformly redundant array (MURA) mask were designed using GATE (Geant4 Application for Tomographic Emission). The penetration ratio, spatial resolution, integral uniformity and signal-to-noise ratio (SNR) were simulated and evaluated as a function of the mask thickness. The spatial resolution of the coded aperture camera was consistent with the various mask thickness, SNR showed a maximum value at 1.2 mm mask thickness and integral uniformity was improved by increasing mask thickness. Compare to the pinhole gamma camera, the coded aperture camera showed improved SNR by a factor of 30 while keeping almost the same spatial resolution. In this simulation study, the results indicated that high spatial resolution and ultra-high SNR of the thyroid imaging are feasible using a coded aperture camera.

  • PDF

T2 Mapping with and without Fat-Suppression to Predict Treatment Response to Intravenous Glucocorticoid Therapy for Thyroid-Associated Ophthalmopathy

  • Linhan Zhai;Qiuxia Wang;Ping Liu;Ban Luo;Gang Yuan;Jing Zhang
    • Korean Journal of Radiology
    • /
    • v.23 no.6
    • /
    • pp.664-673
    • /
    • 2022
  • Objective: To evaluate the performance of baseline clinical characteristics and pretherapeutic histogram parameters derived from T2 mapping of the extraocular muscles (EOMs) in the prediction of treatment response to intravenous glucocorticoid (IVGC) therapy for active and moderate-to-severe thyroid-associated ophthalmopathy (TAO) and to investigate the effect of fat-suppression (FS) in T2 mapping in this prediction. Materials and Methods: A total of 79 patients clinically diagnosed with active, moderate-to-severe TAO (47 female, 32 male; mean age ± standard deviation, 46.1 ± 10 years), including 43 patients with a total of 86 orbits in the responsive group and 36 patients with a total of 72 orbits in the unresponsive group, were enrolled. Baseline clinical characteristics and pretherapeutic histogram parameters derived from T2 mapping with FS (i.e., FS T2 mapping) or without FS (i.e., conventional T2 mapping) of EOMs were compared between the two groups. Independent predictors of treatment response to IVGC were identified using multivariable analysis. Receiver operating characteristic (ROC) curve analysis was performed to evaluate the predictive performance of the prediction models. Differences between the models were examined using the DeLong test. Results: Compared to the unresponsive group, the responsive group had a shorter disease duration, lower kurtosis (FS-kurtosis), lower standard deviation, larger 75th, 90th, and 95th (FS-95th) T2 relaxation times in FS mapping and lower kurtosis in conventional T2 mapping. Multivariable analysis revealed that disease duration, FS-95th percentile, and FS-kurtosis were independent predictors of treatment response. The combined model, integrating all identified predictors, had an optimized area under the ROC curve of 0.797, 88.4% sensitivity, and 62.5% specificity, which were significantly superior to those of the imaging model (p = 0.013). Conclusion: An integrated combination of disease duration, FS-95th percentile, and FS-kurtosis was a potential predictor of treatment response to IVGC in patients with active and moderate-to-severe TAO. FS T2 mapping was superior to conventional T2 mapping in terms of prediction.

The Preoperative Diagnosis of Thyroid Cancer in $^{18}F$-FDG PET/CT Dual Time Imaging of SUV and Evaluation of Radioactivity Measurement (갑상선암 수술 전 진단목적의 $^{18}F$-FDG PET/CT Dual Time Point영상에서 SUV값과 방사능 농도 측정법의 유용성 평가)

  • Lee, Hyun-Kuk;Khang, Hyun Soo;Yang, Seoung-Oh;Han, Man-Seok
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.16 no.2
    • /
    • pp.99-105
    • /
    • 2012
  • Purpose : This study is designed to compare two parameters reflecting $^{18}F$-FDG uptake, SUV and radioactivity, for diagnosis of thyroid cancer in dual time $^{18}F$-FDG PET/CT imaging and to find which parameter is more useful to decide whether the tumor is malignant or not. Materials and Methods : We performed retrospective study for 40 patients. All patients are diagnosed as primary thyroid cancer and examined $^{18}F$-FDG PET/CT. First, we got the dispersion of scattering beam of neck and lung apex to set a background and compared each dispersion, mean value, standard deviation of maxSUV and radioactivity. Also, mean maxSUV, ${\Delta}maxSUV$, ${\Delta}maxBq$/ml(%) and radioactivity between groups according to lesion's size based on biopsy are compared with independent-sample t-test. Results : the values that were from maxSUV and radioactivity measurement technique were compensated and calculated to practical values for mean comparison and patients were divided to two groups based on tumor size, Group1 ($size{\leq}1$ cm, n=21), Group2 (size>1 cm, n=19) for accurate comparison. In Group1, maxSUV (semi-quantitative analysis) was increased from $5.64{\pm}5.85$ (1.89~17.84) at first image to $5.90{\pm}5.01$ (1.95~18.22) at second image and radioactivity (Bq/ml) (quantitative analysis) showed similar increase from $5.93{\pm}6.38$ (2.50~16.75) at first image to $6.01{\pm}5.25$ (2.66~16.58) at second image. In Group2, TFmaxSUV was $10.54{\pm}14.36$ (2.54~33.89) in true first image, TSmaxSUV was $9.85{\pm}12.88$ (2.62~26.20) in true second image separately. The maxSUV showed a significant difference in the mean comparison between the two groups (p=0.035) But, mean radioactivity (Bq/ml) was $5.93{\pm}6.38$ (4.81~40.99) in true first image, $6.01{\pm}5.25$ (4.51~36.93) in true second image and didn't show a significant difference statistically (p=0.126) Conclusion : In diagnosis of thyroid tumor, SUV and radioactivity depending on $^{18}F$-FDG uptake showed high similarity with coefficient of determination (R2=0.939) and malignant evaluation results using dual time also showed similar aspect. Radioactivity for evaluation of malignant tumor didn't show better specificity or sensitivity than maxSUV.

  • PDF

Validation of Ultrasound and Computed Tomography-Based Risk Stratification System and Biopsy Criteria for Cervical Lymph Nodes in Preoperative Patients With Thyroid Cancer

  • Young Hun Jeon;Ji Ye Lee;Roh-Eul Yoo;Jung Hyo Rhim;Kyung Hoon Lee;Kyu Sung Choi;Inpyeong Hwang;Koung Mi Kang;Ji-hoon Kim
    • Korean Journal of Radiology
    • /
    • v.24 no.9
    • /
    • pp.912-923
    • /
    • 2023
  • Objective: This study aimed to validate the risk stratification system (RSS) and biopsy criteria for cervical lymph nodes (LNs) proposed by the Korean Society of Thyroid Radiology (KSThR). Materials and Methods: This retrospective study included a consecutive series of preoperative patients with thyroid cancer who underwent LN biopsy, ultrasound (US), and computed tomography (CT) between December 2006 and June 2015. LNs were categorized as probably benign, indeterminate, or suspicious according to the current US- and CT-based RSS and the size thresholds for cervical LN biopsy as suggested by the KSThR. The diagnostic performance and unnecessary biopsy rates were calculated. Results: A total of 277 LNs (53.1% metastatic) in 228 patients (mean age ± standard deviation, 47.4 years ± 14) were analyzed. In US, the malignancy risks were significantly different among the three categories (all P < 0.001); however, CT-detected probably benign and indeterminate LNs showed similarly low malignancy risks (P = 0.468). The combined US + CT criteria stratified the malignancy risks among the three categories (all P < 0.001) and reduced the proportion of indeterminate LNs (from 20.6% to 14.4%) and the malignancy risk in the indeterminate LNs (from 31.6% to 12.5%) compared with US alone. In all image-based classifications, nodal size did not affect the malignancy risks (short diameter [SD] ≤ 5 mm LNs vs. SD > 5 mm LNs, P ≥ 0.177). The criteria covering only suspicious LNs showed higher specificity and lower unnecessary biopsy rates than the current criteria, while maintaining sensitivity in all imaging modalities. Conclusion: Integrative evaluation of US and CT helps in reducing the proportion of indeterminate LNs and the malignancy risk among them. Nodal size did not affect the malignancy risk of LNs, and the addition of indeterminate LNs to biopsy candidates did not have an advantage in detecting LN metastases in all imaging modalities.

Radio-Iodinated arbutin for tumor imaging

  • Huynh, Phuong Tu;Ha, Yeong Su;Lee, Woonghee;Yoo, Jeongsoo
    • Journal of Radiopharmaceuticals and Molecular Probes
    • /
    • v.3 no.2
    • /
    • pp.72-79
    • /
    • 2017
  • Arbutin is a hydroquinone derivative with a glucose moiety. As a tyrosinase inhibitor, it is widely used as a skin-whitening cosmetic agent for the treatment of cutaneous hyperpigmentary disorders, such as melasma and freckles. In the medical field, many studies have addressed the use of arbutin in various tumors, but the mechanism for tumor uptake of arbutin is still unclear. In this paper, we radiolabeled arbutin using radioiodine and studied its pharmacokinetics and tumor uptake via biodistribution experiments and single-photon emission computed tomography (SPECT) imaging. Radiolabeled $^{131}I-arbutin$ was stable for up to 24 h in PBS and serum. Biodistribution studies and SPECT imaging indicated high uptake of the compound in the bladder and kidneys shortly after injection. Twenty-four hours post-injection, significant deiodination was observed. Apart from high thyroid uptake, selective tumor uptake was clearly observed. The tumor-to-muscle and tumor-to-blood ratios were 26 and 9, respectively.

Optimal Imaging Time for Diagnostic I-123 Whole Body Scan in the Follow-up of Patients with Differentiated Thyroid Cancer: Comparison between 6- and 24-Hour Images of the Same Subjects (분화 갑상선 암의 추적 관찰에서 진단적 I-123 전신 스캔의 최적 영상 시점: 동일 환자에서 6시간과 24시간 영상의 비교)

  • Lee, Hong-Je;Lee, Sang-Woo;Song, Bong-Il;Kang, Sung-Min;Seo, Ji-Hyoung;Yoo, Jeong-Soo;Ahn, Byeong-Cheol;Lee, Jae-Tae
    • Nuclear Medicine and Molecular Imaging
    • /
    • v.43 no.2
    • /
    • pp.129-136
    • /
    • 2009
  • Purpose: To determine optimal imaging time for diagnostic I-123 whole body scan in the follow-up of patients with differentiated thyroid cancer(DTC), we compared the image quality of 6- and 24-hour images of the same subjects. Materials and Methods: Four hundred ninety-eight patients(M:F = 55:443, Age $47.6{\pm}12.9$ years) with DTC who had undergone total thyroidectomy and I-131 ablation therapy underwent diagnostic whole body scanning 6 hour and 24 hour after oral ingestion of 185 MBq(5 mCi) of I-123. Serum thyroglobulin measurement and ultrasonography of the neck were performed at the time of imaging. In 40 patients underwent additional I-131 therapy, post-therapy I-131 images were obtained and compared with diagnostic I-123 images. Results: In 440 patients(88.4%), 6- and 24-hour diagnostic I-123 images were concordant, and 58 patients(11.6%) showed discordant findings. Among 58 discordant patients, 31 patients showed abnormal tracer uptake on only 6-hour image, which turned out false-positive findings in all cases. In 12 patients with positive findings on only 24-hour image, remnant thyroid tissue(4 patients) and cervical lymph node metastasis(3 patients) were presented. Among 40 patients underwent additional I-131 therapy, 6-hour and 24-hour images were discordant in 13 patients. All 5 patients with abnormal uptake on only 6-hour image revealed false-positive results, whereas most of 24-hour images were concordant with post-therapy I-131 images. Conclusion: I-123 imaging at 24-hour could reduce false-positive findings and improve diagnostic accuracy, compared with 6-hour image in the follow-up of patient with DTC.

Evaluation of a Curtain-Type Radiation Protection Device for Veterinary Interventional Procedures

  • Minsik Choi;Jaepung Han;Changgyu Lim;Jiwoon Park;Sojin Kim;Uhjin Kim;Jinhwa Chang;Dongwoo Chang;Namsoon Lee
    • Journal of Veterinary Clinics
    • /
    • v.41 no.3
    • /
    • pp.157-164
    • /
    • 2024
  • The standard radiation protection method in the angiography suite involves the use of a thyroid shield, a lead apron, and lead glasses. However, exposure to substantial amounts of ionizing radiation can cause cataracts, tumors, and skin erythema. A newly developed curtain-type radiation protection device consists of a curtain drape composed of a five-layer bismuth and lead acrylic head-shielding plate, with both bearing an equivalent 0.25 mm lead thickness. In this study, a quality assurance phantom was used as the patient to create radiation scatter from the radiographic source, and an anthropomorphic mannequin phantom was used as the interventionalist to measure the radiation dose at seven different anatomical locations. Thermoluminescent dosimeters were used to measure the radiation dose. The experimental groups consisted of all-sided or one-sided curtain set-ups, the presence or absence of a conventional shielding system, and the orientation of beam irradiation. Consequently, the curtain-type radiation protection device exhibited better radiation protection range and capabilities than conventional radiation protection systems, especially in safeguarding the forehead, eyes, arms, and feet, with minimal radiation exposure. Moreover, the mean shielding ratios of the conventional shielding system and curtain-type radiation protection device were measured at 51.94% and 93.86%, respectively. Additionally, no significant decrease in the radiation protection range or capability was observed, even with changes in the beam orientation or one-sided protection. Compared with a conventional shielding system, the curtain-type radiation protection device decreased radiation exposure doses and improved comfort. Therefore, it is a potential new radiation protection device for veterinary interventional procedures.