• Title/Summary/Keyword: three to

Search Result 108,808, Processing Time 0.134 seconds

Studies on the Mechanical Properties of Weathered Granitic Soil -On the Elements of Shear Strength and Hardness- (화강암질풍화토(花崗岩質風化土)의 역학적(力學的) 성질(性質)에 관(關)한 연구(硏究) -전단강도(剪斷强度)의 영향요소(影響要素)와 견밀도(堅密度)에 대(對)하여-)

  • Cho, Hi Doo
    • Journal of Korean Society of Forest Science
    • /
    • v.66 no.1
    • /
    • pp.16-36
    • /
    • 1984
  • It is very important in forestry to study the shear strength of weathered granitic soil, because the soil covers 66% of our country, and because the majority of land slides have been occured in the soil. In general, the causes of land slide can be classified both the external and internal factors. The external factors are known as vegetations, geography and climate, but internal factors are known as engineering properties originated from parent rocks and weathering. Soil engineering properties are controlled by the skeleton structure, texture, consistency, cohesion, permeability, water content, mineral components, porosity and density etc. of soils. And the effects of these internal factors on sliding down summarize as resistance, shear strength, against silding of soil mass. Shear strength basically depends upon effective stress, kinds of soils, density (void ratio), water content, the structure and arrangement of soil particles, among the properties. But these elements of shear strength work not all alone, but together. The purpose of this thesis is to clarify the characteristics of shear strength and the related elements, such as water content ($w_o$), void ratio($e_o$), dry density (${\gamma}_d$) and specific gravity ($G_s$), and the interrelationship among related elements in order to decide the dominant element chiefly influencing on shear strength in natural/undisturbed state of weathered granitic soil, in addition to the characteristics of soil hardness of weathered granitic soil and root distribution of Pinus rigida Mill and Pinus rigida ${\times}$ taeda planted in erosion-controlled lands. For the characteristics of shear strength of weathered granitic soil and the related elements of shear strength, three sites were selected from Kwangju district. The outlines of sampling sites in the district were: average specific gravity, 2.63 ~ 2.79; average natural water content, 24.3 ~ 28.3%; average dry density, $1.31{\sim}1.43g/cm^3$, average void ratio, 0.93 ~ 1.001 ; cohesion, $ 0.2{\sim}0.75kg/cm^2$ ; angle of internal friction, $29^{\circ}{\sim}45^{\circ}$ ; soil texture, SL. The shear strength of the soil in different sites was measured by a direct shear apparatus (type B; shear box size, $62.5{\times}20mm$; ${\sigma}$, $1.434kg/cm^2$; speed, 1/100mm/min.). For the related element analyses, water content was moderated through a series of drainage experiments with 4 levels of drainage period, specific gravity was measured by KS F 308, analysis of particle size distribution, by KS F 2302 and soil samples were dried at $110{\pm}5^{\circ}C$ for more than 12 hours in dry oven. Soil hardness represents physical properties, such as particle size distribution, porosity, bulk density and water content of soil, and test of the hardness by soil hardness tester is the simplest approach and totally indicative method to grasp the mechanical properties of soil. It is important to understand the mechanical properties of soil as well as the chemical in order to realize the fundamental phenomena in the growth and the distribution of tree roots. The writer intended to study the correlation between the soil hardness and the distribution of tree roots of Pinus rigida Mill. planted in 1966 and Pinus rigida ${\times}$ taeda in 199 to 1960 in the denuded forest lands with and after several erosion control works. The soil texture of the sites investigated was SL originated from weathered granitic soil. The former is situated at Py$\ddot{o}$ngchangri, Ky$\ddot{o}$m-my$\ddot{o}$n, Kogs$\ddot{o}$ng-gun, Ch$\ddot{o}$llanam-do (3.63 ha; slope, $17^{\circ}{\sim}41^{\circ}$ soil depth, thin or medium; humidity, dry or optimum; height, 5.66/3.73 ~ 7.63 m; D.B.H., 9.7/8.00 ~ 12.00 cm) and the Latter at changun-long Kwangju-shi (3.50 ha; slope, $12^{\circ}{\sim}23^{\circ}$; soil depth, thin; humidity, dry; height, 10.47/7.3 ~ 12.79 m; D.B.H., 16.94/14.3 ~ 19.4 cm).The sampling areas were 24quadrats ($10m{\times}10m$) in the former area and 12 in the latter expanding from summit to foot. Each sampling trees for hardness test and investigation of root distribution were selected by purposive selection and soil profiles of these trees were made at the downward distance of 50 cm from the trees, at each quadrat. Soil layers of the profile were separated by the distance of 10 cm from the surface (layer I, II, ... ...). Soil hardness was measured with Yamanaka soil hardness tester and indicated as indicated soil hardness at the different soil layers. The distribution of tree root number per unit area in different soil depth was investigated, and the relationship between the soil hardness and the number of tree roots was discussed. The results obtained from the experiments are summarized as follows. 1. Analyses of simple relationship between shear strength and elements of shear strength, water content ($w_o$), void ratio ($e_o$), dry density (${\gamma}_d$) and specific gravity ($G_s$). 1) Negative correlation coefficients were recognized between shear strength and water content. and shear strength and void ratio. 2) Positive correlation coefficients were recognized between shear strength and dry density. 3) The correlation coefficients between shear strength and specific gravity were not significant. 2. Analyses of partial and multiple correlation coefficients between shear strength and the related elements: 1) From the analyses of the partial correlation coefficients among water content ($x_1$), void ratio ($x_2$), and dry density ($x_3$), the direct effect of the water content on shear strength was the highest, and effect on shear strength was in order of void ratio and dry density. Similar trend was recognized from the results of multiple correlation coefficient analyses. 2) Multiple linear regression equations derived from two independent variables, water content ($x_1$ and dry density ($x_2$) were found to be ineffective in estimating shear strength ($\hat{Y}$). However, the simple linear regression equations with an independent variable, water content (x) were highly efficient to estimate shear strength ($\hat{Y}$) with relatively high fitness. 3. A relationship between soil hardness and the distribution of root number: 1) The soil hardness increased proportionally to the soil depth. Negative correlation coefficients were recognized between indicated soil hardness and the number of tree roots in both plantations. 2) The majority of tree roots of Pinus rigida Mill and Pinus rigida ${\times}$ taeda planted in erosion-controlled lands distributed at 20 cm deep from the surface. 3) Simple linear regression equations were derived from indicated hardness (x) and the number of tree roots (Y) to estimate root numbers in both plantations.

  • PDF

Implementation of integrated monitoring system for trace and path prediction of infectious disease (전염병의 경로 추적 및 예측을 위한 통합 정보 시스템 구현)

  • Kim, Eungyeong;Lee, Seok;Byun, Young Tae;Lee, Hyuk-Jae;Lee, Taikjin
    • Journal of Internet Computing and Services
    • /
    • v.14 no.5
    • /
    • pp.69-76
    • /
    • 2013
  • The incidence of globally infectious and pathogenic diseases such as H1N1 (swine flu) and Avian Influenza (AI) has recently increased. An infectious disease is a pathogen-caused disease, which can be passed from the infected person to the susceptible host. Pathogens of infectious diseases, which are bacillus, spirochaeta, rickettsia, virus, fungus, and parasite, etc., cause various symptoms such as respiratory disease, gastrointestinal disease, liver disease, and acute febrile illness. They can be spread through various means such as food, water, insect, breathing and contact with other persons. Recently, most countries around the world use a mathematical model to predict and prepare for the spread of infectious diseases. In a modern society, however, infectious diseases are spread in a fast and complicated manner because of rapid development of transportation (both ground and underground). Therefore, we do not have enough time to predict the fast spreading and complicated infectious diseases. Therefore, new system, which can prevent the spread of infectious diseases by predicting its pathway, needs to be developed. In this study, to solve this kind of problem, an integrated monitoring system, which can track and predict the pathway of infectious diseases for its realtime monitoring and control, is developed. This system is implemented based on the conventional mathematical model called by 'Susceptible-Infectious-Recovered (SIR) Model.' The proposed model has characteristics that both inter- and intra-city modes of transportation to express interpersonal contact (i.e., migration flow) are considered. They include the means of transportation such as bus, train, car and airplane. Also, modified real data according to the geographical characteristics of Korea are employed to reflect realistic circumstances of possible disease spreading in Korea. We can predict where and when vaccination needs to be performed by parameters control in this model. The simulation includes several assumptions and scenarios. Using the data of Statistics Korea, five major cities, which are assumed to have the most population migration have been chosen; Seoul, Incheon (Incheon International Airport), Gangneung, Pyeongchang and Wonju. It was assumed that the cities were connected in one network, and infectious disease was spread through denoted transportation methods only. In terms of traffic volume, daily traffic volume was obtained from Korean Statistical Information Service (KOSIS). In addition, the population of each city was acquired from Statistics Korea. Moreover, data on H1N1 (swine flu) were provided by Korea Centers for Disease Control and Prevention, and air transport statistics were obtained from Aeronautical Information Portal System. As mentioned above, daily traffic volume, population statistics, H1N1 (swine flu) and air transport statistics data have been adjusted in consideration of the current conditions in Korea and several realistic assumptions and scenarios. Three scenarios (occurrence of H1N1 in Incheon International Airport, not-vaccinated in all cities and vaccinated in Seoul and Pyeongchang respectively) were simulated, and the number of days taken for the number of the infected to reach its peak and proportion of Infectious (I) were compared. According to the simulation, the number of days was the fastest in Seoul with 37 days and the slowest in Pyeongchang with 43 days when vaccination was not considered. In terms of the proportion of I, Seoul was the highest while Pyeongchang was the lowest. When they were vaccinated in Seoul, the number of days taken for the number of the infected to reach at its peak was the fastest in Seoul with 37 days and the slowest in Pyeongchang with 43 days. In terms of the proportion of I, Gangneung was the highest while Pyeongchang was the lowest. When they were vaccinated in Pyeongchang, the number of days was the fastest in Seoul with 37 days and the slowest in Pyeongchang with 43 days. In terms of the proportion of I, Gangneung was the highest while Pyeongchang was the lowest. Based on the results above, it has been confirmed that H1N1, upon the first occurrence, is proportionally spread by the traffic volume in each city. Because the infection pathway is different by the traffic volume in each city, therefore, it is possible to come up with a preventive measurement against infectious disease by tracking and predicting its pathway through the analysis of traffic volume.

Application of a Single-pulsatile Extracorporeal Life Support System for Extracorporeal Membrane Oxygenation -An experimental study - (단일 박동형 생명구조장치의 인공폐 적용 -실험연구-)

  • Kim, Tae-Sik;Sun, Kyung;Lee, Kyu-Baek;Park, Sung-Young;Hwang, Jae-Joon;Son, Ho-Sung;Kim, Kwang-Taik;Kim. Hyoung-Mook
    • Journal of Chest Surgery
    • /
    • v.37 no.3
    • /
    • pp.201-209
    • /
    • 2004
  • Extracorporeal life support (ECLS) system is a device for respiratory and/or heart failure treatment, and there have been many trials for development and clinical application in the world. Currently, a non-pulsatile blood pump is a standard for ECLS system. Although a pulsatile blood pump is advantageous in physiologic aspects, high pressure generated in the circuits and resultant blood cell trauma remain major concerns which make one reluctant to use a pulsatile blood pump in artificial lung circuits containing a membrane oxygenator. The study was designed to evaluate the hypothesis that placement of a pressure-relieving compliance chamber between a pulsatile pump and a membrane oxygenator might reduce the above mentioned side effects while providing physiologic pulsatile blood flow. The study was performed in a canine model of oleic acid induced acute lung injury (N=16). The animals were divided into three groups according to the type of pump used and the presence of the compliance chamber, In group 1, a non-pulsatile centrifugal pump was used as a control (n=6). In group 2 (n=4), a single-pulsatile pump was used. In group 3 (n=6), a single-pulsatile pump equipped with a compliance chamber was used. The experimental model was a partial bypass between the right atrium and the aorta at a pump flow of 1.8∼2 L/min for 2 hours. The observed parameters were focused on hemodynamic changes, intra-circuit pressure, laboratory studies for blood profile, and the effect on blood cell trauma. In hemodynamics, the pulsatile group II & III generated higher arterial pulse pressure (47$\pm$ 10 and 41 $\pm$ 9 mmHg) than the nonpulsatile group 1 (17 $\pm$ 7 mmHg, p<0.001). The intra-circuit pressure at membrane oxygenator were 222 $\pm$ 8 mmHg in group 1, 739 $\pm$ 35 mmHg in group 2, and 470 $\pm$ 17 mmHg in group 3 (p<0.001). At 2 hour bypass, arterial oxygen partial pressures were significantly higher in the pulsatile group 2 & 3 than in the non-pulsatile group 1 (77 $\pm$ 41 mmHg in group 1, 96 $\pm$ 48 mmHg in group 2, and 97 $\pm$ 25 mmHg in group 3: p<0.05). The levels of plasma free hemoglobin which was an indicator of blood cell trauma were lowest in group 1, highest in group 2, and significantly decreased in group 3 (55.7 $\pm$ 43.3, 162.8 $\pm$ 113.6, 82.5 $\pm$ 25.1 mg%, respectively; p<0.05). Other laboratory findings for blood profile were not different. The above results imply that the pulsatile blood pump is beneficial in oxygenation while deleterious in the aspects to high pressure generation in the circuits and blood cell trauma. However, when a pressure-relieving compliance chamber is applied between the pulsatile pump and a membrane oxygenator, it can significantly reduce the high circuit pressure and result in low blood cell trauma.

THE EFFECT OF ND:YAG LASER IRRADIATION ON THE FORMATION OF CALCIUM FLUORIDE AND ACID RESISTANCE OF TOOTH ENAMEL (Nd:YAG 레이저 조사가 Calcium Fluoride 형성 및 치아 내산성에 미치는 영향)

  • Lee, Jae-Ho;Sohn, Heung-Kyu;Kim, Seong-Oh;Park, Kwang-Kyun;Choi, Byung-Jai
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.26 no.2
    • /
    • pp.377-398
    • /
    • 1999
  • Calcium fluoride, created by topical fluoride application, is the reservoir for fluoride ion regulated by pH in the oral environment. Therefore, the amount and the maintenance of calcium fluoride have an important role in preventing dental caries. The aim of this study is to evaluate the effect of Nd:YAG laser irradiation on the generation of calcium fluoride and the acid resistance of tooth enamel. The bovine anterior permanent teeth were prepared (n=276), and divided into following groups : no treatment (control) fluoride application alone, laser irradiation alone, laser irradiation after fluoride application, and fluoride application after laser irradiation. And each group was subdivided based on the application time of 1.23% acidulated phosphate fluoride (APF) (5 min and 30 min) and the irradiation energy of Nd:YAG laser ($20J/cm^2\;and\;40J/cm^2$). In case of fluoride application, each group was divided according to KOH treatment. Twenty three treatment conditions were made for this experiment and twelve specimens were assigned to each treatment condition. In each treatment condition, ten specimens were used for chemical analysis and two specimens were observed under SEM. In groups without treating KOH, fluoride content and the depth of enamel dissolved were measured using enamel biopsy technique. In groups with treating KOH, the amount of calcium fluoride was measured by the treatment with 1 M KOH for 24 hours and enamel biopsy was performed after KOH treatment. The results were analyzed by the fluoride content and the depth of enamel dissolved by enamel biopsy, amount and thickness of calcium fluoride, and the surface structures of enamel. The results are as follows: 1. In groups without treating KOH, the fluoride content of removed enamel showed a positive relationship with the energy density of laser when the laser irradiated before fluoride application 2. In groups without treating KOH, the depth of enamel dissolved decreased more with the combined laser and fluoride treatment than with laser or fluoride treatment, except for the case of $20J/cm^2$ laser irradiation after 5 minute fluoride application (p<0.05). 3. The amount of calcium fluoride did not increased by laser treatment with no statistical significance(p>0.05). 4. The particle size of calcium fluoride increased in case of fluoride treatment after laser irradiation, compared with fluoride application alone. In case of laser treatment after fluoride application, the particle size of calcium fluoride increased and some of the particles fused as well. 5. There were no significant differences in the fluoride content of dissolved enamel between groups without treating KOH and control group, except for the case of laser irradiation after treatment of APF for 30 minutes (p>0.05). 6. In groups with treating KOH, depth of removed enamel in the groups of combined treatment with laser and fluoride was shallower than that in fluoride application groups (p<0.05). 7. In groups without treating KOH, the relationship between fluoride content and the depth of enamel dissolved showed more negative (Spearman correlation coefficient: -0.6281) than in groups with treating KOH (Spearman correlation coefficient: -0.3792). The greater amount of calcium fluoride could be found in case where there was a significant differences of the depth of enamel dissolved between groups with and without treating KOH. From these results, it can be concluded that laser seems to be a little effects on the amount of calcium fluoride formation, but has some effect on the lowering the solubility of calcium fluoride. As the combined treatment of laser and fluoride application showed more effective acid-resistant property, more extended recall period for fluoride application can be achieved with this combined treatment in the clinic.

  • PDF

Methacholine Responsiveness of Bronchial and Extrathoracic Airway in Patients with Chronic Cough (만성 기침 환자에서 기관지와 흉곽외 기도의 Methacholine 유발검사의 의의)

  • Shim, Jae-Jeong;Kim, Je-Hyeong;Lee, Sung-Yong;Kwan, Young-Hwan;Lee, So-Ra;Lee,, Sang-Yeub;Lee, Sang-Hwa;Suh, Jung-Kyung;Cho, Jae-Youn;In, Kwang-Ho;Yoo, Se-Hwa;Kang, Kyung-Ho
    • Tuberculosis and Respiratory Diseases
    • /
    • v.44 no.4
    • /
    • pp.853-860
    • /
    • 1997
  • Background : Chronic cough, defined as a cough persisting for three weeks or longer, is a common symptom for which outpatient care is sought. The most common etiologies of chronic cough are postnasal drip, asthma, and gastroesophageal reflux. Methacholine challenge is a useful diagnostic study in the evaulation of chronic cough, particularly useful in chronic cough patients with asthmatic symptom. Patients with chronic cough may have dysfunction of bronchial and extrathoracic airways. To evaluate if dysfunction of the bronchial and extrathoracic airways causes chronic cough, we assessed bronchial (BHR) and extrathoracic airway (EAHR) responsiveness to inhaled methacholine in patients with chronic cough. Method : 111 patients with chronic cough were enrolled in our study. Enrolled patients had no recorded diagnosis of asthma, bronchopulmonary disease, hypertension, heart disease or systemic disease and no current treatment with bronchodilator or corticosteroid. Enrolled patients consisted of 46 patients with cough alone, 24 patients with wheeze, 22 patients with dyspnea, 19 patients with wheeze and dyspnea. The inhaled methacholine concentrations causing a 20% fall in forced expiratory volume in 1s($PC_{20}FEV_1$) and 25% fall in maximal mid-inspiratory flow ($PC_{25}MIF_{50}$) were used as bronchial and extra thoracic hyperresponsiveness. Results : There were four response patterns to methacholine challenge study : BHR in 27 patients, EAHR in 16 patients, combined BHR and EAHR in 8 patients, and no hyperresponsiveness in 60 patients. In patients with cough alone, there were BHR in 3 patients, EAHR in 9 patients, and combined BHR and EAHR in 2 patients. In patients with wheeze and/or dyspnea, there were BHR in 24 patients, EAHR in 7 patients, and BHR and EAHR in 6 patients. Compared with patients with wheeze and/or dyspnea, patients with cough alone had more common EAHR than BHR. In patients with wheeze and/or dyspnea, BHR was more common than EAHR. Conclusion : These results show that among patients with hyperresponsiveness to methacholine, those with dyspnea and/or wheezing had mainly bronchial hyperresponsiveness, whereas those with chronic cough alone had mainly extrathoracic airway hyperresponsiveness.

  • PDF

Assessment of Demand and Use of Fresh-Cut Produce in School Foodservice and Restaurant Industries (학교급식 및 외식업체에서의 신선편이 농산물 사용실태 및 요구도 평가)

  • Sun, Shih-Hui;Kim, Ju-Hee;Kim, Su-Jin;Park, Hye-Young;Kim, Gi-Chang;Kim, Haeng-Ran;Yoon, Ki-Sun
    • Journal of the Korean Society of Food Science and Nutrition
    • /
    • v.39 no.6
    • /
    • pp.909-919
    • /
    • 2010
  • The purpose of this study was to investigate the demand and use of fresh-cut produce in school foodservice and restaurant industries. The subjects of this survey study were 200 school nutritionists and 70 cooks or managers in the restaurant industry nationwide. The data were collected by means of self-administered or e-mail questionnaires. Data analysis was completed using the SPSS window (ver. 12.0) program including frequency, $\chi^2$-test and t-test. Survey questions assessed the general characteristic of respondents, and the supply, use, and demand of fresh-cut produce in school foodservice and restaurant industries. Over 74% of the subjects have used fresh-cut produce. Most of the school foodservice (84.0%) kept fresh-cut produce for one day, while restaurant industry (28.3%) kept them up to three days. The nutritionists of school foodservice and managers of restaurant industry considered origin and date of production as the most important factor, respectively, when fresh-cut produce were being used. Fresh-cut root vegetable, such as potato and carrot was used mostly. The main reason not to use the fresh cut produce was due to the distrust of the fresh-cut produce safety in school foodservice and cost in restaurant industry. The main problem in fresh-cut produce use was the need of rewashing (29.9%) in school foodservice and irregular size (39.0%) in restaurant industry. These results indicate that the quality standard and size specification must be prepared with production guideline of safe fresh-cut produce.

The Effects of pH Change in Extraction Solution on the Heavy Metals Extraction from Soil and Controversial Points for Partial Extraction in Korean Standard Method (용출액의 pH 변화가 토양내 중금속 용출에 미치는 영향과 그에 따른 국내 토양 오염 공정시험방법의 문제점)

  • 오창환;유연희;이평구;이영엽
    • Economic and Environmental Geology
    • /
    • v.36 no.3
    • /
    • pp.159-170
    • /
    • 2003
  • Heavy metals are extracted from Chonju stream sediment, roadside soils and sediments along Honam expressway, soils and tailings from mining area using three different methods (partial extraction in Standard Method, partial extraction method with maintaining 0.1 N of extraction solution and Sequential Extraction Method). In samples having buffer capacity against acid, pH 1 (0.1 N HCl) of extraction solution can not be maintained and pH of extraction solution increases up to 8.0 when partial extraction in Standard Method is used. The averages and ranges of HPE(heavy metals extracted using partial extraction in Standard Method)/HPEM(heavy metals extracted using partial extraction method with maintaining 0.1 N of extraction solution) values are 0.479 and 0.145~0.929 for Cd, 0.534 and 0.078~0.928 for Zn, 0.432 and 0.041~0.992 for Mn, 0.359 and 0.011~0.874 for Cu, 0.150 and 0.018~0.530 for Cr, 0.219 and 0.003~0.853 for Pb, and 0.088 and 1.73${\times}$10$^{-5}$~0.303 for Fe. These data indicate that the difference between HPE and HPEM is large in the order of Fe, Cr, Pb, Cu, Mn, Cd and Zn. The amounts of heavy metals extracted decreases in the follow order; Sum III(sum of fraction I, II, III in sequential extraction)>HPEM>Sum III (sum of fraction I and II)>HPE for Zn, Cd and Mn and Sum III>HPEM>HPE for Cr and Fe. In the case Cr, Sum II is lower than HPEM and higher than HPE. In case of Cu, extracted heavy metals is large in the order Sum IV>HPEM>Sum III HPE. HPE/HPEM value decreases with increasing the amount of HCl used for maintaining 0.1 N of extraction solution. For samples with high buffer capacity, HPE/HPEM value in all elements is lower than 0.2. On the other hand, for samples with low buffer capacity, HPE/HPEM value are over 0.2 and many samples have values higher than 0.6 for Zn, Cd Mn and Cu due to the small difference between Sum II and Sum III, and relatively higher mobility. However, for Fe and Cr, HPE/HPEM value is below 0.2 even for samples with low buffer capacity due to their low mobility and big difference between Sum II and Sum III. This study indicates that the partial extraction method in Korean Standard Method of soil is not suitable for an assessment of soil contamination in area where buffer capacity of soil can be decreased or lost because of a long term exposure to environmental damage such as acidic rain.

Effects of Anti-thyroglobulin Antibody on the Measurement of Thyroglobulin : Differences Between Immunoradiometric Assay Kits Available (면역방사계수법을 이용한 Thyroglobulin 측정시 항 Thyroglobulin 항체의 존재가 미치는 영향: Thyroglobulin 측정 키트에 따른 차이)

  • Ahn, Byeong-Cheol;Seo, Ji-Hyeong;Bae, Jin-Ho;Jeong, Shin-Young;Yoo, Jeong-Soo;Jung, Jin-Hyang;Park, Ho-Yong;Kim, Jung-Guk;Ha, Sung-Woo;Sohn, Jin-Ho;Lee, In-Kyu;Lee, Jae-Tae;Kim, Bo-Wan
    • The Korean Journal of Nuclear Medicine
    • /
    • v.39 no.4
    • /
    • pp.252-256
    • /
    • 2005
  • Purpose: Thyroglobulin (Tg) is a valuable and sensitive tool as a marker for diagnosis and follow-up for several thyroid disorders, especially, in the follow-up of patients with differentiated thyroid cancer (DTC). Often, clinical decisions rely entirely on the serum Tg concentration. But the Tg assay is one of the most challenging laboratory measurements to perform accurately owing to antithyroglobulin antibody (Anti-Tg). In this study, we have compared the degree of Anti-Tg effects on the measurement of Tg between availale Tg measuring kits. Materials and Methods: Measurement of Tg levels for standard Tg solution was performed with two different kits commercially available (A/B kits) using immunoradiometric assay technique either with absence or presence of three different concentrations of Anti-Tg. Measurement of Tg for patient's serum was also performed with the same kits. Patient's serum samples were prepared with mixtures of a serum containing high Tg levels and a serum containg high Anti-Tg concentrations. Results: In the measurements of standard Tg solution, presence of Anti-Tg resulted in falsely lower Tg level by both A and B kits. Degree of Tg underestimation by h kit was more prominent than B kit. The degree of underestimation by B kit was trivial therefore clinically insignificant, but statistically significant. Addition of Anti-Tg to patient serum resulted in falsely lower Tg levels with only A kit. Conclusion: Tg level could be underestimated in the presence of anti-Tg. Anti-Tg effect on Tg measurement was variable according to assay kit used. Therefore, accuracy test must be performed for individual Tg-assay kit.

Microbiological Evaluation of Foods and Kitchen Environments in Childcare Center and Kindergarten Foodservice Operations (보육시설과 유치원 급식의 식품 및 환경 미생물의 오염도 평가)

  • Seol, Hye-Rin;Park, Hyoung-Su;Park, Ki-Hwan;Park, Ae-Kyung;Ryu, Kyung
    • Journal of the Korean Society of Food Science and Nutrition
    • /
    • v.38 no.2
    • /
    • pp.252-260
    • /
    • 2009
  • Whereas the numbers of childcare centers and kindergartens are increasing rapidly, systematic management to control the food safety of foodservice operation is not yet well established. Samples from 12 centers in Seoul and Gyeonggi Province were collected to assess the microbiological quality of 32 raw materials, 24 cooked foods, 76 food-contact surfaces (knives, cutting boards, dish towels and gloves), 17 employees' hands and 12 air-borne bacteria. The microbiological analyses were performed for aerobic plate counts (APC), Enterobacteriaceae, E. coli and 7 pathogens (B. cereus, C. jejuni, C. perfringens, L. monocytogenes, Salmonella spp., S. aureus, and V. parahaemolyticus). Among raw materials, E. coli ($1.39{\sim}2.08\;\log\;CFU/g$) were detected in 4 out of 6 meats and 7.46 log CFU/g of APC in tofu. High enterobacteriaceae levels of 4.23, 5.14 and 4.19 log CFU/g were found in cucumber salad, steamed spinach with seasonings and steamed bean sprout with seasonings, respectively. No pathogens were found in all samples except for C. perfringens detected from raw spinach and raw lotus root. Only APC and enterobacteriaceae were found in food-contact surfaces. Two of the 23 knives and three of the 24 kitchen boards showed over 500 CFU/$100\;cm^2$ of APC; also, APC levels (5.03 to 5.44 log CFU/g) were detected in 4 of the 12 dish towels. Only one glove showed Enterobacteriaceae (2.44 log CFU/glove) contamination. Enterobacteriaceae were found in 2 employees' hands ($2.37{\sim}4.44\;\log\;CFU$/hand) among the 16 employees. The contamination levels of air-borne bacteria were shown unacceptable in two (2.25 and 2.30 log CFU/petri-film/15 min) out of the 12 kitchen areas. These results suggest that the microbiological hazards in some foods and environments are not well controlled and thus a guideline should be provided to ensure the food safety in childcare center and kindergarten foodservice operations.

Mid-Term Results of 292 cases of Coronary Artery Bypass Grafting (관상동맥 우회술 292례의 중기 성적)

  • 김태윤;김응중;이원용;지현근;신윤철;김건일
    • Journal of Chest Surgery
    • /
    • v.35 no.9
    • /
    • pp.643-652
    • /
    • 2002
  • As the prevalence of coronay artery disease is increasing, the surgical treatment has been universalized and operative outcome has been improved. We analyzed the short and mid-term results of 292 CABGs performed in Kangdong Sacred Heart Hospital. Material and Method: From June 1994 to December 2001, 292 patients underwent coronary artery bypass grafting. There were 173 men and 119 women and their ages ranged from 39 to 84 years with a mean of $61.8{\pm}9.1$ years. We analyzed the preoperative risk factors, operative procedures and operative outcome. In addition, we analyzed the recurrence of symptoms, long-term mortality and complications via out-patient follow-up for discharged patients. Result: Preoperative clinical diagnoses were unstable angina in 137(46.9%), stable angina in 34(11.6%), acute myocardial infarction in 40(13.7%), non-Q myocardial infarction in 25(8.6%), postinfarction angina in 22(7.5%), cardiogenic shock in 30(10.3%) and PTCA failure in 4(1.4%) patients. Preoperative angiographic diagnoses were three-vessel disease in 157(53.8%), two-vessel disease in 35 (12.0%), one-vessel disease in 11(3.8%) and left main disease in 89(30.5%) patients. We used saphenous veins in 630, internal thoracic arteries in 257, radial arteries in 50, and right gastoepiploic arteries in 2 distal anastomoses. The mean number of distal anastomoses per patient was $3.2{\pm}1.0$ There were 18 concomitant procedures ; valve replacement in 8(2.7%), left main coronary artery angioplasty in 6(2.1%), patch closure of postinfarction ventricular septal defect(PMI-VSD) in 2(0.7%), replacement of ascending aorta in 1(0.3%) and coronary endarterectomy in 1(0.3%) patient. The mean ACC time was $96.6{\pm}35.3 $ minutes and the mean CPB time was $179.2{\pm}94.6$ minutes. Total early mortality was 8.6%, but it was 3.1% in elective operations. The most common cause of early mortality was low cardiac output syndrome in 6(2.1%) patients. The stastistically significant risk factors for early mortality were hypertension, old age($\geq$ 70 years), poor LV function(EF<40%), congestive heart failure, preoperative intraaortic balloon pump, emergency operation and chronic renal failure. The most common complication was arrhythmia in 52(17.8%) patients. The mean follow-up period was $39.0{\pm}27.0$ months. Most patients were free of symptoms during follow-up. Fourteen patients(5.8 %) had recurrent symptoms and 7 patients(2.9%) died during follow-up period. Follow-up coronary angiography was performed in 13 patients with recurrent symptoms and they were managed by surgical and medical treatment according to the coronary angiographic result. Conclusion: The operative and late results of CABG in our hospital, was acceptable. However, There should be more refinement in operative technique and postoperative management to improve the results.