• Title/Summary/Keyword: three doors

Search Result 71, Processing Time 0.022 seconds

Building Facilities Management Using the Condition Prediction Process: A Case Study of Fiberglass Doors

  • Amani, Nima
    • Journal of Construction Engineering and Project Management
    • /
    • v.4 no.3
    • /
    • pp.47-52
    • /
    • 2014
  • In the last decades, Facility Management (FM) has established itself as a key building service factor.FM includes supporting services and organizing functions essential for maintaining, operating and managing physical component and material. The purpose of the paper is to develop an economical analysis for building facilities management during its service life based on limited cost. This method helps to facilities managers and engineers to make better decisions for reducing of facilities assessment costs and increasing the facilities' service life. This paper presents the preliminary development of a model involves three stages process namely data collection, economic computation and economic process optimization. This process was tested for fiberglass doors example in a building interior and exterior system. If executives can manage essential points effectively and make decisions according to a key performance index, cost can be optimized and safety can be enhanced for installation building.

Evaluation of the Alternatives to Minimize Stack Effect Problems with Elevators in Tall Complex Buildings (초고층 복합건축물 엘리베이터에서의 연돌현상 저감방안 평가)

  • Yu, Jung-Yeon;Song, Kyoo-Dong;Cho, Dong-Woo
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.21 no.2
    • /
    • pp.118-125
    • /
    • 2009
  • The purpose of this study is to evaluate the stack effect reduction alternatives in tall complex buildings in cold climates. The main problems in tall buildings occur in elevators. Such problems as elevator doors that do not close and exhaust airflows result in excessive pressure differences across elevator doors due to stack effect. Under the expected conditions causing these pressure differences, Field measurements are performed in three tall buildings. Each result of the measurements is analyzed in architectural design aspects. With these analysis, building design guidelines are proposed and analyzed by field measurements and computer simulations.

Smoke Control in a Subway Station Platform with Screen Doors - Based on Busan Subway Line 3 - (스크린도어 설치에 따른 지하승강장 제연의 문제점과 대책 - 부산 지하철 3호선을 중심으로 -)

  • Park, Woe-Chul
    • Fire Science and Engineering
    • /
    • v.20 no.1 s.61
    • /
    • pp.50-54
    • /
    • 2006
  • A fire in a subway station platform, completely isolated by screen doors, was numerically simulated to investigate problems in smoke control and find their countermeasures. A part of the platform, $40m{\times}5m$ floor and 3 m high, and a fire of 1 MW were considered, and the smoke extraction system was assumed to start operation at the onset of the fire. For three different values of the exhaust air flow rate, 0.1, 2, and $4m^3/min-m^2$, the distributions of temperature, concentrations of soot and carbon monoxide, and those of visibility were compared. The time-variations of the number of randomly distributed particles in the space were also investigated for the air flow rates to see the efficiency in smoke control. It was shown that smoke control takes time by lack of air supply. It was also confirmed that air supply from the railway to the platform at emergency is needed so that smoke is able to be controlled efficiently, and that opening the doors at the both ends of the platform is desirable until the fire is completely extinguished.

A Comparative Study on PM10 Source Contributions in a Seoul Metropolitan Subway Station Before/After Installing Platform Screen Doors (서울시 지하철 승강장의 스크린도어 설치 전·후 PM10 오염원의 기여도 비교 연구)

  • Lee, Tae-Jung;Jeon, Jae-Sik;Kim, Shin-Do;Kim, Dong-Sool
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.26 no.5
    • /
    • pp.543-553
    • /
    • 2010
  • Almost five million citizens a day are using subways as a means of traffic communication in the Seoul metropolitan. As the subway system is typically a closed environment, indoor air pollution problems frequently occurs and passengers complain of mal-health impact. Especially $PM_{10}$ is well known as one of the major pollutants in subway indoor environments. The purpose of this study was to compare the indoor air quality in terms of $PM_{10}$ and to quantitatively compare its source contributions in a Seoul subway platform before and after installing platform screen doors (PSD). $PM_{10}$ samples were collected on the J station platform of Subway Line 7 in Seoul metropolitan area from Jun. 12, 2008 to Jan. 12, 2009. The samples collected on membrane filters using $PM_{10}$ mini-volume portable samplers were then analyzed for trace metals and soluble ions. A total of 18 chemical species (Ba, Mn, Cr, Cd, Si, Fe, Ni, Al, Cu, Pb, Ti, $Na^+$, $NH_4^+$, $K^+$, $Mg^{2+}$, $Ca^{2+}$, $Cl^-$, and ${SO_4}^{2-}$) were analyzed by using an ICP-AES and an IC after performing proper pre-treatments of each sample filter. Based on the chemical information, positive matrix factorization (PMF) model was applied to identify the source of particulate matters. $PM_{10}$ for the station was characterized by three sources such as ferrous related source, soil and road dust related source, and fine secondary aerosol source. After installing PSD, the average $PM_{10}$ concentration was decreased by 20.5% during the study periods. Especially the contribution of the ferrous related source emitted during train service in a tunnel route was decreased from 59.1% to 43.8% since both platform and tunnel areas were completely blocked by screen doors. However, the contribution of the fine secondary aerosol source emitted from various outside combustion activities was increased from 14.8% to 29.9% presumably due to ill-managed ventilation system and confined platform space.

FE Analysis on the Structural Behavior of the Single-Leaf Blast-Resistant Door According to Design Parameter Variation (설계변수에 따른 편개형 방폭문의 구조거동 유한요소해석)

  • Shin, Hyun-Seop;Kim, Won-Woo;Park, Gi-Joon;Lee, Nam-Kon;Moon, Jae-Heum;Kim, Sung-Wook
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.20 no.11
    • /
    • pp.259-272
    • /
    • 2019
  • Steel-concrete single-leaf blast-resistant doors are protective structures consisting of a steel box and reinforced concrete slab. By the domestic blast-resistant doors, the structure is not designed efficiently because few studies have examined the effects of variables, such as the blast pressure, rebar ratio, and steel plate thickness on the structural behavior. In this study, the structural behavior of the doors was analyzed using the FE method, and the support rotation and ductility ratio used to classify the structural performance were reviewed. The results showed that the deflection changes more significantly when the plate thickness increases than when the rebar spacing is a variable. This is because the strain energy absorbed by the door is reduced considerably when the plate thickness increases, and as a result, the maximum deflection becomes smaller. According to a comparison of the calculated values of the support rotation and the ductility ratio, the structural performance of the doors could be classified based on the support rotation of one degree and ductility ratio of three. On the other hand, more explosion tests and analytical studies will be needed to classify the damage level.

Validation of FDS for Pool Fire in Three Rooms Connected to Ventilation Network (환기가 제한된 세 개 격실에서 Pool Fire에 대한 FDS 검증분석)

  • Bae, Young-Bum;Lee, Sang-Kyu;Shin, Byung-Soo;Kim, Nam-Seok;Keum, O-Hyun;Park, Jong-Seok
    • Proceedings of the Korea Institute of Fire Science and Engineering Conference
    • /
    • 2011.04a
    • /
    • pp.9-15
    • /
    • 2011
  • This study aims to validate predictive capabilities of FDS for the pool fire in three rooms connected to ventilation network. The three rooms in real scale fire test facility are configured to be similar to that of nuclear power plant in size, ventilation condition, construction material, etc. Basically three rooms are confined to the other area except two open doors and two ventilation duct in each room. The real scale fire test was conducted with these conditions and the predictive capabilities of FDS will be validated by comparing FDS simulation results with experimental data from the temperature, heat flux, and concentration point of view. This study concludes that temperature from FDS is about 25 % lower deviation from the experiment, and heat flux from FDS is about 5% deviation.

  • PDF

A Comparative Case Study of Factors Determining Documentary Films' Success :Focusing on "My Love, Don't Cross That River" and "Two Doors" (다큐멘터리영화의 성공을 결정짓는 요인에 관한 비교사례연구 -<님아, 그 강을 건너지 마오>와 <두 개의 문>을 중심으로)

  • Im, So-Yeon;Lee, Yun-Cheol
    • The Journal of the Korea Contents Association
    • /
    • v.17 no.10
    • /
    • pp.503-517
    • /
    • 2017
  • After a few recent documentary films had commercial success, factors for their success are getting attention. This paper explores the factors of the financial success of two documentary films. "My Love, Don't Cross That River" gained extended popularity with its universal message, and "Two Doors" conveyed a poweful political message. This paper conducted a case study by inteviewing production directors and distribution managers. Analysis was based on the three categories suggested by Litman and Kohl(1989): creative sphere, distribution-scheduling release pattern, and marketing efforts. Findings present the common factors of the two movies' success in the following areas: persons and events showing a powerful reality, a message with new and fresh insight, artistic quality, distribution strategy with timely scheduling, release time (period), public relations, and advertising.. In addition, "My Love, Don't Cross That River" was helped by a sufficient budget for scheduling/releasing and advertising. Its wide-release stratergy worked as well. "Two Doors" was aided by the government support for release and by the special factor called 'Participating viewer'. By examining the factors of documentary films' commercial success, this study has an implication for the popularization of documentary movies by indicating how to strategically apply relevant factors.

Investigation of acoustic performances of the creative convergence classrooms in elementary schools (초등학교 창의융합교실의 음향성능 조사)

  • A-Hyeon Jo;Chan-Hoon Haan
    • The Journal of the Acoustical Society of Korea
    • /
    • v.42 no.4
    • /
    • pp.285-297
    • /
    • 2023
  • The present study aims to investigate the acoustic performance of the creative convergence classrooms in Korea used by elementary school students under the age of 9 introduced through the school space innovation project. In order to do this, acoustic performances of three creative convergence classrooms were measured. The measured acoustic parameters were background noise levels, Reverberation Time (RT), D50, Speech Transmission Index (STI), and Inter-Aural Cross Correlation (IACC). Also, acoustic parameters including Transmission Loss (TL) and standardized level difference (DnT) have been measured for the analysis of sound insulation performance of walls. In addition, the noise level was measured according to the opening conditions of doors and windows in the classroom. As a result, background noise level was measured at an average of 28.0 dB(A) to 32.8 dB(A) when the air conditioner was not operated, and the RT did not exceed 0.6 s. There were differences in IACC according to various desk layouts, and IACC values were high in the center line and the seats near the sound source. In particular, higher IACC was measured at the seats on the center line facing the source squarely. Regarding noise level in the classroom according to the opening conditions of doors and windows, the standards were exceeded when all windows, or windows and doors front onto the corridor were opened.

A Study on the Characteristics of Traditionality Expression at Modernized Chinese Restaurants - Focused on MT(Modernized Traditional) Syle Restaurants in Hong Kong - (현대화 된 중국식 레스토랑에 나타난 전통성 표현 특성 연구 - 홍콩 소재 MT 유형(Modernized Traditional Style) 레스토랑을 중심으로 -)

  • Oh, Hye-Kyung
    • Korean Institute of Interior Design Journal
    • /
    • v.21 no.4
    • /
    • pp.163-171
    • /
    • 2012
  • The objective of this study was to analyze the characteristics of traditionality expressions at modernized Chinese restaurant in Hong Kong. As a case study, the study examined 12 modernized Chinese restaurants in Hong Kong. The gathered data were categorized and examined according to the ways of traditionality expressions, which included reproduction, transformation, and reinterpretation of traditional components. Each of the components was measured for the amount of traditional or modernity expression on a five-point scale. The five-point scoring system put an emphasis on heritage; 1 point was given to principal modernity(modernity: 90-100% + tradition: 0-10%), 2 points were given to principal modernity + auxiliary tradition(modernity: 70-90% + tradition: 10-30%), 3 points were given to the same ratio between tradition and modernity(modernity: 40-60% + tradition: 40-60%), 4 points were given to principal tradition + auxiliary modernity(modernity: 10-30% + tradition: 70-90%), and 5 points were given to principal tradition(modernity: 0-10% + tradition: 90-100%). The analysis performed according to those criteria and methodologies led to the following findings and conclusions: Traditional components were most reproduced in the ornaments placed all over the restaurant and applied to the chirography of the restaurant logos, walls, and windows/doors in a big number. The methodology of transforming tradition was evenly applied to each of the spatial components. With the most transformations occurring to the lattices, there were many different ways to transform tradition including the partition, chirography, pattern, red lantern, furniture and ornament, and traditional materials that were turned into modern ones. Few examples of reinterpreting tradition were observed in the restaurant titles, inside floors, and ceilings, but plenty of examples were found in the walls, windows/doors, lighting, and furniture in a range of ways. Most of them reinterpreted the traditional forms and added altered patterns to them to remind customers of tradition. In short, all of the three ways of expressing tradition were actively applied to each component in an array of ways.

  • PDF

Warping and Buckling Prediction Model of Wooden Hollow Core Flush Door due to Moisture Content Change (I) : Comparison of Prediction Model with Experimental Results (목제(木製) 프러쉬 문의 함수율 변동에 따른 틀어짐과 좌굴 예측모델 (I) : 예측모델과 실측치 비교)

  • Kang, Wook;Jung, Hee-Suk
    • Journal of the Korean Wood Science and Technology
    • /
    • v.27 no.3
    • /
    • pp.99-116
    • /
    • 1999
  • Wooden hollow core flush door is one of the main products of furniture manufacturing and woodworking industries. Warping and buckling of the door is serious problems in service. It has been reported that warping is caused by differences of physical and mechanical properties of face and back of skin panel for the door. This study focused on the prediction of warping and buckling phenomena of the flush door using numerical models. Predictions from the models were also compared with the experimental results obtained from the doors with plywood and hardboard skin panels under various environmental conditions. Three elastic constitutive models, so called elastic beam model, plate model and plate-buckling model, were employed to predict warping and buckling of the doors. It was observed that warping was more pronounced in low humidity condition than in high humidity condition. The plate model considering Poisson's effect was reliable to predict warping more closely than elastic beam model in low humidity condition. The plate-buckling model, however, was the best in the fitting of predictions with the experimental results under high humidity condition because buckling was developed in face and back of skin panel at that condition.

  • PDF