• 제목/요약/키워드: three doors

검색결과 71건 처리시간 0.019초

창덕궁 선정전의 의례 공간적 건축 구조 (The Architectural Structure of Seonjeong-jeon in Changdeok Palace as a Ceremonial Hall)

  • 이종서
    • 건축역사연구
    • /
    • 제29권2호
    • /
    • pp.39-52
    • /
    • 2020
  • Seonjeong-jeon, the semi-great hall in Changdeok Palace, was constructed in a highly formal and conservative style and accommodated official ceremonies. However, the contemporary modification of the building has distorted or eliminated features including the two side doors on the front, the floor coverings, and the throne base (Jwa-tap) that consisted the most significant part of the throne. Seonjeong-jeon originally had three doors that stood between each pair of columns on the front side, respectively. The courtiers accessed the building through the side doors, while the central door was exclusively designated for the king. However, the renovation in 1999 ignored the political context of the architectural form of the building and changed the side doors into windows, damaging the traditional structure inherited from the early Joseon Dynasty. Although the building currently has traditional wooden floor structure (Woomul-maru), it was originally covered with square brick tiles (Bang-jeon) before the Japanese occupation, following the customs of early Joseon Dynasty. The throne was placed to the north of the central door and consisted of the throne base and a decorative roof (Dang-ga). A canvas (Jang-ja), which featured the royal symbolic painting of Sun, Moon, and Five Peaks, was also installed between the two columns that connected the base and the roof. Nevertheless, only the columns and the blank canvas remain nowadays after the removal of the base.

지하철의 섬식 정거장에 설치된 스크린도어에 가해지는 열차풍압 해석 (Analysis on the Train-wind Pressure applied to Screen Door in Island-type Platform of Subway)

  • 김정엽
    • 한국전산유체공학회:학술대회논문집
    • /
    • 한국전산유체공학회 2008년도 춘계학술대회논문집
    • /
    • pp.138-141
    • /
    • 2008
  • The screen doors installed in the station of subway are subject to the train-wind pressure caused by the operation of trains. The train-wind pressure has to be correctly estimated for the design of safe structure of screen doors. As three-dimensional numerical flow analysis technology has been significantly developed, the analysis on the train-wind pressure with diverse variables such as train specifications, train speed, tunnel and station configurations, and blockage ratio can be effectively carried out with three-dimensional numerical method. In this study, computational analysis of train-induced wind in a subway tunnel employing the screen doors are carried out by using the three-dimensional numerical method with the model of the moving boundary for the run of trains. While the numerical analysis of train-wind pressure was applied on the one island-type station in the Seoul Subway Line 2, maximum pressure of 494 Pa was estimated on the screen door when two trains pass each other at the speed of 80km/h in the platform.

  • PDF

실측과 시뮬레이션을 통한 초고층 주거건물에서의 연돌효과 문제의 해결 (Solving the Problems Caused by Stack Effect in a High-rise Residential Building through Field Measurement and Simulation; Case Study)

  • 구성한;조재훈;여명석;김광우
    • 한국주거학회논문집
    • /
    • 제16권4호
    • /
    • pp.73-80
    • /
    • 2005
  • A high-rise residential building experienced stack effect problems during the winter such as difficulties in opening residential entrance doors and whistling noise from elevator doors generated by airflow. Field measurements were carried out on the building and the problems were verified by the analysis of the measurement results from three points of view: the total stack pressure difference, pressure distribution on each floor, and the location of the neutral pressure level. Based on the analysis of the three key parameters, possible solutions were proposed, such as zoning vertical shafts, lessening the airflow from the entrance doors on basement floors and lobby floor by installing vestibules, improving the airtightness of exterior walls, and installing separation doors where the problems occur. Simulations of proposed solutions were conducted and the effects of reducing the pressure difference were evaluated. Stack effect problems in a high-rise residential building were verified through field measurements and could be mitigated by the solutions which were drawn from the analysis of the field measurements and the simulation results.

Mathematical Models that Underlie Computer Simulation of the Trawl Doors for Mid-Water Trawls

  • Gabryuk, Victor Ivanovich;Kudakaev, Vasilii Vladimirovich
    • Ocean and Polar Research
    • /
    • 제42권1호
    • /
    • pp.77-88
    • /
    • 2020
  • This paper presents the coordinate systems used for trawl doors modeling, and provides matrix equations of connection between these systems. The projections of the forces acting on the door into axes of various coordinate systems were obtained, which were used in the door equilibrium equations. Six equilibrium conditions for the door as a solid were obtained: formulas that allow for the door area in plan to be determined; its weight in water; its mass; three moment equations for determining the position of the warp and backstrops fastening points to the door with triangular and quadrangular backstrop arrangements. It was found that the moment equilibrium equations of trawl doors are generally incompatible, which was not found by any of the authors who have previously conducted research into trawl doors. Using the Kronecker-Capelli theorem, the compatibility equation is obtained. This equation includes the coordinates of the backstrop fastening points to the door, which means that these points cannot be randomly selected. The technique of determining the warp and backstrops' fastening points position to the door is described. Conditions of directional (by angle of attack) and roll (in angle of roll) stability of the doors' equilibrium are presented. The equations presented in this paper comprise a mathematical model that allows, when designing the doors, to select optimal parameters, as well as to carry out adjustments for trawling purposes to ensure the stable movement of the doors and the entire trawl system.

3대 가족형 집합주거의 실용화를 위한 기초연구(I) -계획기준의 도출과 계획기준을 이용한 3대 가족형 주거와의 비교분석을 중심으로- (Study on development of three generation family type apartment plan -Deduction of standard plan and compare standard plan with three generation family type apartment-)

  • 윤삼석;김진모
    • 한국실내디자인학회논문집
    • /
    • 제16권4호
    • /
    • pp.39-46
    • /
    • 2007
  • The aim of this study was to recognize the need of three generation family house that is traditional house type of Korea. First, the pre-research analysis method was used for this study. And then, there are three type's grouping like those are as follows; 1) Recognition of three generation family house. 2) Type of three generation family house. 3) Plans of three generation family house. The analysis results are as follows; If the conditions are better than now, recognition is positive. Type are living together and next doors type can direct access. Some standart plan is been about room's number, house's area, bath's number and so on. Second, try to compare plan - this plan already has been used building - with standard plan. The compare result are as follows; three generation family houses - be used by whom - do not apply to standard plan. Almost houses have a three room that is less than the standard plan. All houses have a number of two bath that is less than the standard plan too. Condition of consideration is suitable to ages in next door type, but in case of living together type that consider user whom is use the inner room. Separation of entrance distinguish between the living together type and the next doors type. In case of living together type Dining with Kitchen room's number is one, but the next doors type have the number of two.

피라미드 트러스 심재를 채용한 도시철도차량 출입문의 구조강성평가 (Structural Stiffness Analysis on Doors having Pyramidal Truss Cores in an Urban Transit Vehicle)

  • 임재용
    • 한국산학기술학회논문지
    • /
    • 제18권6호
    • /
    • pp.697-702
    • /
    • 2017
  • 본 연구에서는 현재 운행 중인 도시철도차량의 전동차 출입문에 규칙적 다공질 금속, 즉, 트러스 요소로 이루어진 피라미드 트러스 코어를 적용 가능한가에 대해 구조 강성 측면에서 검토하였다. 전동차 출입문은 내외피 사이 심재부에 허니콤과 보강재로 구성된 샌드위치 구조이며, 충분한 굽힘 강성과 내구성 등이 요구된다. 현재, 전동차 출입문의 기계적 성능은 한국철도표준규격(KRS)과 도시철도용품 품질규격에서 명시되고 있는데, 3점굽힘시험을 수행하여 중앙부의 처짐량을 측정하여 구조강성의 만족 여부를 판정하고 있다. 기존의 허니컴 코어를 채용한 출입문에 비해 피라미드 트러스 코어로 대체한 출입문의 구조강성 비교를 위하여 기존의 허니콤 코어와 동일한 무게의 두 종류의 피라미드 트러스 코어를 설계, 고려하였다. 이후 한국철도표준규격에 명시한 시험조건에 따라 유한요소해석을 실시하였다. 피라미드 트러스 코어를 적용한 전동차 출입문의 3점굽힘해석 결과 피라미드 트러스 심재 출입문은 기존의 허니콤 심재에 비해 약 2.5%의 처짐량이 더 발생하였지만, 규격에서 요구한 강성 조건을 충분히 만족시켰다. 따라서, 다기능성에 유리한 규칙적 다공질 금속인 피라미드 트러스 심재는 기존의 허니콤 기반의 출입문을 대체할 수 있을 것으로 판단된다.

열차 운행에 따른 상대식 승강장에서 지하철 승강장 스크린 도어 풍압해석 (THE PRESSURE-TRANSIENT ANALYSIS ON THE PLATFORM SCREEN DOORS OF THE SIDE PLATFORMS IN A SUBWAY STATION WITH VARIOUS OPERATING CONDITIONS)

  • 이명성;안혁진;원찬식;허남건
    • 한국전산유체공학회:학술대회논문집
    • /
    • 한국전산유체공학회 2008년도 학술대회
    • /
    • pp.283-289
    • /
    • 2008
  • The pressure-transient on platform screen doors in side platforms caused by passing trains with various operating conditions have been investigated numerically. The transient compressible three-dimensional flow simulations are performed with actual operating conditions of two trains by adopting moving mesh technique. To achieve more realistic results, the detailed shape of train and the subway station including tunnels connecting the adjacent stations are represented in the computational domain. Numerical analyses are carried out for cases considering arriving/passing/departing train with or without train stopped on the opposite track, and both trains on the move in opposite direction. From the numerical results, the maximum pressure on the platform screen doors, which is predicted in the case of two passing trains, satisfied the design standards for similar stations.

  • PDF

열차 운행에 따른 상대식 승강장에서 지하철 승강장 스크린 도어 풍압해석 (THE PRESSURE-TRANSIENT ANALYSIS ON THE PLATFORM SCREEN DOORS OF THE SIDE PLATFORMS IN A SUBWAY STATION WITH VARIOUS OPERATING CONDITIONS)

  • 이명성;안혁진;원찬식;허남건
    • 한국전산유체공학회:학술대회논문집
    • /
    • 한국전산유체공학회 2008년 추계학술대회논문집
    • /
    • pp.283-289
    • /
    • 2008
  • The pressure-transient on platform screen doors in side platforms caused by passing trains with various operating conditions have been investigated numerically. The transient compressible three-dimensional flow simulations are performed with actual operating conditions of two trains by adopting moving mesh technique. To achieve more realistic results, the detailed shape of train and the subway station including tunnels connecting the adjacent stations are represented in the computational domain. Numerical analyses are carried out for cases considering arriving/passing/departing train with or without train stopped on the opposite track, and both trains on the move in opposite direction. From the numerical results, the maximum pressure on the platform screen doors, which is predicted in the case of two passing trains, satisfied the design standards for similar stations.

  • PDF

방화문의 내화성능 향상을 위한 3단 문 결속기 연구개발 (Research and development of a three-stage door binder to improve the fire resistance of fire doors)

  • 임보혁;이주원;조동환;이해열
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2023년도 가을학술발표대회논문집
    • /
    • pp.157-158
    • /
    • 2023
  • Doors that are opened and closed when entering or exiting a general building are connected to the door frame and open and close. They are equipped with door locking devices of various structures, and are either locked to the door frame for the closing operation or released from the door frame for the opening and closing operation. Here, a single-stage door binding device having a door latch that is independently disposed at the center of one axis of the door is commonly used. On the other hand, if the size of the door is over a certain size or if the door is medium to large, the opening and closing operation may not be performed smoothly with only a single stage binder, or the closing state may not be achieved stably during the closing operation. In particular, in the case of the single-stage binding device provided in medium to large fire doors, the door is fixed to the door frame unstable, causing fatal errors in the fire prevention function of the fire door. Accordingly, in order to fundamentally solve these problems, we researched and developed a three-stage door binding machine that combines a top and bottom fastening structure with a single-stage fastening structure. This 3-stage door binder not only has the fire resistance performance of a fire door, but also has a T-shaped terminal in its fastening method, so if you eliminate the upper and lower fastening, it is a 1-stage binder like a regular product, but if you remove the door latch of the 1st-stage binder, it functions as an upper and lower 2-stage binder and forms a single mold. We researched and developed a three-stage door binder that can manufacture and produce three products at the same time, satisfying both product performance and price.

  • PDF

우이-신설 경전철 출입문 설계를 위한 승하차시간 분석 연구 (A Statistical Study on Doorway Flow-time for Designing Doors of Ui LRT)

  • 오석문;장현목;신한철
    • 한국철도학회논문집
    • /
    • 제16권2호
    • /
    • pp.144-150
    • /
    • 2013
  • 본 논문은 서울시 우이-신설 경전철의 출입문 사양 결정을 위한 승하차 시간 예측 모의실험 내용과 실험 데이터 분석결과를 제시한다. 우이-신설 경전철과 유사한 차량(김해 경전철 차량) 및 운영조건을 설정하여 승하차 시간을 측정하는 모의실험을 반복적으로 실시한다. 실험계획은 승하차 인원의 시나리오에 따라 4가지로 구성하였으며, 총 39회의 모의실험을 실시하였다. 이 실험결과를 활용하여 우이-신설 경전철의 출입문 폭과 수량에 대한 차량설계 방안의 적절성 검증이 가능하였다. 실험결과에 대한 통계적 분석으로 승하차 인원의 변화에 따른 승하차 시간 분석을 실시하였다. 실험계획에서 설정된 시나리오를 승하차 인원의 규모에 따라 다시 3가지 수준으로 분류하고, 수준별 승하차 시간의 평균과 분산을 조사하였다. 다음 승차, 하차 및 재차 인원의 구성에 따른 일원배치 분산분석(One-Way ANOVA)을 실시하여 각각의 구성이 승하차 시간에 미치는 영향을 분석하였다. 본 논문에서 제시된 실험결과 및 분석결과들은 장래 도시형 경전철 차량의 출입문 설계 관련 업무에 활용될 수 있을 것으로 판단된다.