• Title/Summary/Keyword: thickness sensitivity

Search Result 654, Processing Time 0.031 seconds

First trimester screening for trisomy 18 by a combination of nuchal translucency thickness and epigenetic marker level

  • Lee, Da Eun;Kim, Shin Young;Kim, Hyun Jin;Park, So Yeon;Kim, Min Hyoung;Han, You Jung;Ryu, Hyun Mee
    • Journal of Genetic Medicine
    • /
    • v.14 no.1
    • /
    • pp.1-7
    • /
    • 2017
  • Purpose: The aim of this study was to assess the diagnostic efficacy of noninvasive prenatal screening for trisomy 18 by assessing the levels of unmethylated-maspin (U-maspin) and fetal nuchal translucency (NT) thickness during the first trimester of pregnancy. Materials and Methods: A nested case-control study was conducted using maternal plasma samples collected from 65 pregnant women carrying 11 fetuses with trisomy 18 and 54 normal fetuses. We compared the U-maspin levels, NT thicknesses, or a combination of both in the first trimester between the case and control groups. Results: U-maspin levels and NT thickness were significantly elevated in the first trimester in pregnant women carrying fetuses with trisomy 18 when compared to those carrying normal fetuses (27.2 vs. 6.6 copies/mL, P<0.001 for U-maspin; 5.9 vs. 2.0 mm, P<0.001 for NT). The sensitivities of the U-maspin levels and NT thickness in prenatal screening for fetal trisomy 18 were 90.9% and 90.9%, respectively, with a specificity of 98.1%. The combined U-maspin levels and NT thickness had a sensitivity of 100% in prenatal screening for fetal trisomy 18, with a specificity of 98.1%. Conclusion: A combination of U-maspin levels and NT thickness is highly efficacious for noninvasive prenatal screening of fetal trisomy 18 in the first trimester of pregnancy.

Fabrication of silicon piezoresistive pressure sensor for a biomedical in-vivo measurements (생체 in-vivo 측정용 실리콘 압저항형 압력센서의 제조와 그 특성)

  • Bae, Hae-Jin;Son, Seung-Hyun;Choi, Sie-Young
    • Journal of Sensor Science and Technology
    • /
    • v.10 no.3
    • /
    • pp.148-155
    • /
    • 2001
  • A pressure sensor on the tip of a catheter which is utilized to measure the in-vivo pressure in a human body was fabricated and the characteristic of the pressure sensor as measured. To fit into a catheter with 1 mm caliber, samples of $150\;{\mu}m$(thickness) ${\times}$ (600, 700, 800, 900, 1000) ${\mu}m$(width) ${\times}2\;mm$(length) was fabricated. The thicker face with $450\;{\mu}m$ thickness of SDB wafer was made thin to $134\;{\mu}m$ thickness using KOH etchant and it made possible to fabricate sensor cell with the width shorter than 1 mm. Different to the whitstone bridge sensor, we formed one piezoresistor and one reference resistor in sensor. Therefore there are possibilities of reduction of the sensitivity, then by using the simulation tool ANSYS 5.5.1, the location and the type of the piezoresistor was optimized. Another piezoresistor type of sensor which contain one longitudinal and one transverse piezoresistor was fabricated at the same time, but the sensitivity was not improved very much. To get the output versus the pressure, a constant current source and a implementation amplifier was used. As a result, the maximum sensitivity of the sensor with one piezoresistor was $1.6\;{\mu}V/V/mmHg$.

  • PDF

The Difference in Diagnostic Performance for Detection of Supraspinatus Tendon Tears by Adding Angled Oblique Sagittal Plane Image to the Routine Shoulder MRI (고식적 견관절 자기공명영상에 추가적인 사각시상면 영상 이용 시 극상건 손상 검출 진단능 차이에 대한 고찰)

  • Kim, Ji Hee;Kim, Hyun Joo;Cha, Jang Gyu;Choi, Duk Lin;Hong, Seong Sook;Chang, Yun Woo;Hwang, Jung Hwa
    • Investigative Magnetic Resonance Imaging
    • /
    • v.18 no.2
    • /
    • pp.157-166
    • /
    • 2014
  • Purpose : The purpose of this study is to determine whether adding an angled oblique sagittal plane to the routine shoulder MRI improves the diagnostic performance in the evaluation of supraspinatus tendon tears with arthroscopic correlation. Materials and Methods: The study included 121 patients who had a shoulder MRI followed by arthroscopy. Two radiologists separately evaluated the supraspinatus tendon for tears on shoulder MRI either with or without the angled oblique sagittal images. Arthroscopy was used as the reference standard. The sensitivity and specificity for diagnosing supraspinatus tendon tears were calculated and compared by using McNemar test. Interobserver and intertechnique variability in the interpretation of supraspinatus tendon tears were calculated as a kappa value. Results: Adding the angled oblique sagittal images to the standard shoulder MRI showed improvement in the sensitivity for diagnosing full-thickness supraspinatus tendon tears and also in the sensitivity, specificity and accuracy for the detection of partial-thickness tears. However, there was no statistically significant difference in all of them between with and without the angled set. Interobserver agreement was substantial to almost perfect and intertechnique agreement was moderate. Conclusion: Adding an angled oblique sagittal plane image to the routine shoulder MRI showed no significantly different diagnostic performance in detecting the partial- and full-thickness supraspinatus tendon tears, compared to MRI without angled oblique sagittal plane.

Effect of Ultra-thin Catalyst Deposited upon $In_2O_3$ Thin Film on CO Sensitivity ($In_2O_3$ 박막위에 증착된 초박막 촉매가 CO의 검출 감도에 미치는 영향)

  • Lee, Hye-Jung;Song, Jae-Hoon;Kwon, Soon-Nam;Kim, Tae-Song;Kim, Kwang-Ju;Jung, Hyung-Jin;Choi, Won-Kook
    • Journal of Sensor Science and Technology
    • /
    • v.9 no.6
    • /
    • pp.430-439
    • /
    • 2000
  • $In_2O_3$-based thin film sensor with 500-600 nm thick was fabricated for the detection of CO gas by rf magnetron sputtering. In order to improve both sensitivity to CO gas and selectivity to hydrogen gas containing -CH, ultra-thin transition metal Co catalyst was sputtered over $In_2O_3$ thin film and annealed at $500^{\circ}C$. Sensitivity to CO was maximum at the thickness of Co 2.1 nm and $300^{\circ}C$, and that to $C_3H_8$ was at the thickness of Co 1.4 nm and $350-400^{\circ}C$. From the x-ray photoelectron spectroscopy (XPS) result, ultra-thin Co was existed into CoO covered with $Co_2O_3$ on $In_2O_3$ particles, and thus p-n junction of $In_2O_3(n-type)$-CoO(p-type) was thought to be formed. In this p-n junction type sensors, sensing mechanism with reducing gases can be explained by the variation of depletion layer thickness formed in the interface.

  • PDF

Correlation between Carotid Intima-media Thickness and Risk Factors for Atherosclerosis (경동맥 내중막 두께에 따른 죽상경화반의 위험요인과의 상관관계)

  • An, Hyun;Lee, Hyo Yeong
    • Journal of the Korean Society of Radiology
    • /
    • v.13 no.3
    • /
    • pp.339-348
    • /
    • 2019
  • The purpose of this study was to investigate the effect of carotid artery ultrasound Respectively. The carotid intima-media thickness is known to have a significant correlation with cardiovascular disease and cerebrovascular disease. We investigated the relationship between carotid intima - media thickness, body mass index, waist circumference, the blood lipid value, fasting blood glucose, glycated hemoglobin, and blood pressure using carotid artery ultrasound. The carotid artery ultrasound was considered to be abnormality of IMT thickness over 0.8 mm and the presence or absence of atherosclerotic plaque was evaluated. Serological tests were used to compare the geologic value, fasting blood glucose level, and glycated hemoglobin. As a result, waist circumference (=.022), low density cholesterol (=.004), fasting blood glucose level (.019), and glycemic index (.002) were analyzed as predictors of atherosclerosis. In the ROC curve analysis, sensitivity was 87.80% (95% CI: 73.8-95.9), specificity was 41.67% (95% CI: 30.2-53.9), sensitivity was 78.05% (95% CI: 62.4-89.4) in low density lipoprotein, Specificity was 50.00% (95% CI: 38.0-62.0), sensitivity was 73.11% (95% CI: 57.1-85.8), specificity was 61.11 (95% CI: 48.9-72.4) and sensitivity was 82.93%-91.8) and a specificity of 43.06% (31.4-55.3). In logistic regression analysis, the risk of atherosclerosis was 0.248 times at waist circumference (WC)> 76 cm, 3.475 times at low-density lipoprotein (LDL-C) ${\geq}124mg/dL$, 0.618 at HbA1c> 5.4% It appeared as a times. We suggest that prospective study of carotid artery ultrasound should be performed for the effective prevention of cardiovascular diseases.

Fabrication of Circular Diaphragm for Piezoelectric Acoustic Devices

  • Lee, Woon-Seob;Kim, Yong-Chul;Lee, Jin-Seung;Lee, Seok-Woo;Lee, Seung-S.
    • JSTS:Journal of Semiconductor Technology and Science
    • /
    • v.5 no.1
    • /
    • pp.52-57
    • /
    • 2005
  • This paper describes a fabrication method of a circular diaphragm using boron etching stop method. It will be applied to acoustic transducers such as microphones or microspeakers and so on. The sensitivity is expected to be increased with the circular diaphragm through the simulation results to compare with a general rectangular diaphragm. The borondoped layer which is doped with solid source is sufficient for achieving an etching stop in 20 wt% TMAH, and the thickness is about $7.4{\mu}m$. The diameter of the circular silicon nitride diaphragm was measured to be 2 mm with $1{\mu}m$ thickness. The fabrication of piezoelectric acoustic devices was completed.

Sensing properties of ZnO thin films fabricated by RF sputtering method for toxic gas (RF sputtering 방법을 이용하여 제작한 ZnO 박막의 유독성 가스에 대한 반응 특성 연구)

  • Hwang, Hyun-Suk;Kang, Hyun-Il;Song, Joon-Tae
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2009.06a
    • /
    • pp.247-247
    • /
    • 2009
  • In this work, Ga-doped ZnO (GZO) thin films for toxic gas sensor application were deposited on low temperature co-fired ceramic (LTCC) substrates, by RF magnetron sputtering method. LTCC is one of promising materials for integration with heater, low cost production and high manufacturing yields than silicon substrate. The LTCC substrates with thickness of $400\;{\mu}m$ were fabricated by laminating 12 greentapes which consist of alumina and glass particle in an organic binder. The GZO thin films deposited on the substrates and were analyzed by X-ray diffraction method (XRD) and field emission scanning electron microscope (FESEM). The films are well crystallized in the hexagonal (wurzite) structure with increasing thickness. The fabricated sensors showed good sensitivity and fast response time to common types of toxic gases (NOx, COx).

  • PDF

Printability of an Aqueous Gravure Ink for Polyolefin (Polyolefin용 수성 Gravure Ink의 인쇄작성)

  • 김종원
    • Journal of the Korean Graphic Arts Communication Society
    • /
    • v.12 no.1
    • /
    • pp.1.1-11
    • /
    • 1994
  • The photosensitive properties and carrier transport in the organic photoconductor with the carrier transport layers(CTL) of polymer matrix doped with two carrier transport materials above carrier generation layer(CGL) containing oxotitanium phthalocyanine (TiOPc) were investigated. The CGL of TiOPc dispersed in poly(vinylbutyral) was formed as thickness of 0.1${\mu}{\textrm}{m}$and the carrier transport layer was prepared by coating polycarbonate and polyester doped with oxadiazoly(OXD), polyvinylcarbazole (PVK), trinitro fluorenone(TNF) as thickness of 10~15${\mu}{\textrm}{m}$, respectively. We have measured half decay exposure,sensitivity and xerographic gain from the photo-induced discharge curve(PIDC). In this work, it was found that the characteristics of carrier transport were mainly caused by the ionization potential difference of constitutive materials in molecularly doped polymer.

  • PDF

Design of Energy Absorption Device Using the Axial Crushing Behavior of Truncated Cone Type Cylinder (콘 형상 실린더의 축 방향 압축변형을 이용한 충격흡수장치 설계)

  • 김지철;이학렬;김일수;심우전;박동화
    • Tribology and Lubricants
    • /
    • v.19 no.5
    • /
    • pp.259-267
    • /
    • 2003
  • A brake device for the high-speed impacting object is designed using an axial crushing of thin-walled metal cylinder. Thickness of the cylinder is increased smoothly from the impacting end to the fixed end, resulting in the truncated cone shape. Truncated cone shape minimizes the imperfection-sensitivity of the structure and ensures that plastic hinges are formed sequentially from impacting end. This prevents the undesirable sudden rise in the first peak-crushing load. Several specimens with different conic angles, mean thickness of the wall, and materials were designed and quasi-static compression tests were performed on them. Results indicate that adoption of appropriate conic angle prevents simultaneous wrinkles generation and sudden rise of crushing load and that appropriate conic angle differs in each case, depending on the geometry and material property of the cylinder. Finite element analysis was performed for static compression of the cylinder and its accuracy was checked for the future application.

Preparation of Quasi-ordered Hollow $SnO_2$ Hemispheres Using Colloidal Templating Route and Its Application to Gas Sensors (콜로이달 템플레이팅 기술을 통한 준정렬된 다공성 반구구조의 $SnO_2$ 제작과 가스 센서로의 응용)

  • Chang, Young-Eun;Yang, Dae-Jin;Kim, Dong-Hoon;Cho, Nam-Gyu;Kim, Ho-Gi;Kim, Il-Do
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2008.11a
    • /
    • pp.282-282
    • /
    • 2008
  • Quasi-ordered arrays of hollow $SnO_2$ hemispheres were prepared by utilizing the colloidal templating route and RF-sputtering methods. Hollow $SnO_2$ hemispheres with shell thickness of 20nm exhibited an uniform continuity and open porosity, resulting in high gas sensitivity due to enhanced surface area as well as reduced interfacial effects. Multilayered hollow $SnO_2$ hemispheres and hollow $SnO_2$ hemispheres with controlled wall thickness were fabricated by controlling processing steps.

  • PDF