• 제목/요약/키워드: thickness sensitivity

검색결과 654건 처리시간 0.025초

An ionization Chamber for a Steel Sheet Thickness Measurement

  • Kim, Han-Soo;Park, Se-Hwa;Kim, Yong-Kyun;Ha, Jang-Ho;Cho, Seung-Yeon
    • Journal of Radiation Protection and Research
    • /
    • 제31권3호
    • /
    • pp.149-153
    • /
    • 2006
  • An ionization chamber is still widely used in many fields by virtue of its' simple operational characteristics and the possibility of its' various shapes. A parallel type of an ionization chamber for a steel sheet thickness measurement was designed and fabricated. High pure xenon gas, which was pressurized up to 6 atm, was chosen as a filling gas to increase the current response and sensitivity for a radiation. A high pressure gas system was also constructed. The active volume and the incident window size of the fabricated ionization chamber were $30\;cm^3\;and\;12\;cm^2$, respectively. Preliminary tests with a 25 mCi $^{241}Am$ gamma-ray source and evaluation tests in a standard X-ray field were performed. The optimal operation voltage was set from the results of the collection efficiency calculation by using an experimental two-voltage method. Linearity for a variation of the steel sheet thickness, which is the most important factor for an application during a steel sheet thickness measurement, was 0.989 in this study.

길이와 두께 비에 따른 두께 전단모드 압전소자의 공진 변위 및 압전특성 (Resonant Displacement and Piezoelectric Properties of Thickness Shear Mode Piezoelectric Devices According to Length/Thickness Ratio)

  • 박민호;류주현;홍재일;정영호
    • 한국전기전자재료학회논문지
    • /
    • 제24권6호
    • /
    • pp.463-467
    • /
    • 2011
  • In this study, thickness shear mode piezoelectric devices for AE sensor with excellent displacement and sensitivity characteristics were simulated using ATILA FEM program, and then fabricated. Displacement and electro mechanical coupling factors of the piezoelectric devices were investigated. The simulation results showed that excellent displacement and electromechanical coupling factor was obtained when the ratio of Length/Thickness was 1. The piezoelectric device of L/T= 1 exhibited the optimum values of fr= 150 kHz, displacement= $6.23{\times}10^{-8}$[m], $k_{15}$= 0.598. The results show that the thickness shear mode piezoelectric device is a promising candidate for the application of AE sensor piezoelectric device.

Influence of the Thin-Film Ag Electrode Deposition Thickness on the Current Characteristics of a CVD Diamond Radiation Detector

  • Ban, Chae-Min;Lee, Chul-Yong;Jun, Byung-Hyuk
    • Journal of Radiation Protection and Research
    • /
    • 제43권4호
    • /
    • pp.131-136
    • /
    • 2018
  • Background: We investigated the current characteristics of a thin-film Ag electrode on a chemical vapor deposition (CVD) diamond. The CVD diamond is widely recognized as a radiation detection material because of its high tolerance against high radiation, stable response to various dose rates, and good sensitivity. Additionally, thin-film Ag has been widely used as an electrode with high electrical conductivity. Materials and Methods: Considering these properties, the thin-film Ag electrode was deposited onto CVD diamonds with varied deposition thicknesses (${\fallingdotseq}50/98/152/257nm$); subsequently, the surface thickness, surface roughness, leakage current, and photo-current were characterized. Results and Discussion: The leakage current was found to be very low, and the photo-current output signal was observed as stable for a deposited film thickness of 98 nm; at this thickness, a uniform and constant surface roughness of the deposited thin-film Ag electrode were obtained. Conclusion: We found that a CVD diamond radiation detector with a thin-film Ag electrode deposition thickness close to 100 nm exhibited minimal leakage current and yielded a highly stable output signal.

후판 Al 6061합금의 전자빔용접 특성 평가 (The Characteristic Evaluation of Electron Beam Welding for Al 6061 alloy with thick-thickness plate)

  • 정인철;심덕남;김용재
    • 대한용접접합학회:학술대회논문집
    • /
    • 대한용접접합학회 2006년도 춘계 학술대회 개요집
    • /
    • pp.68-70
    • /
    • 2006
  • For the aluminum material of the thick-thickness more than 100mm Penetration depth Electron beam welding is effectively applicable with a characteristic of high energy intensity. But Al 6061 alloy has high crack sensitivity due to minor alloys, which are silicon, magnesium, copper etc. With a sample block of 135mm thickness EBW test was performed in vertical position. As tensile strength has $210{\sim}220N/mm^2$ with weld area broken. Bend test shows low ductility with fracture of partly specimens. Chemical contents of alloys show no difference between weld and base metal. Defect in middle weld area figures out typical hot crack due to low melting materials. Micro structure of weld area has some difference compare to HAZ and base metal. As a result of EBW test for Al 6061 alloy, it shows that weld defect could be occurred even though establishing of optimum weld parameter condition.

  • PDF

정상 월경주기를 가진 불임환자에서 질식초음파검사를 이용한 자궁내막 형태 및 두께의 변화 양상에 관한 연구 (Transvaginal Ultrasonographic Analysis of Endometrial Pattern and Thickness Changes in Normal Menstrual Cycle)

  • 서창석;김석현;최영민;김정구;문신용;이진용
    • Clinical and Experimental Reproductive Medicine
    • /
    • 제25권2호
    • /
    • pp.153-160
    • /
    • 1998
  • The objective of this retrospective study was to evaluate whether the transvaginal ultrasonographic analysis of endometrial pattern and thickness could predict the stage of menstrual cycle. Endometrial pattern and thickness were observed in those patients receiving infertility work up from April, 1994 to July, 1998 at Seoul National University Hospital. The study group was 185 patients with normal regular menstrual cycles. Among them, 44 patients received endometrial biopsy, and the date of endometrium was compared with the observed endometrial pattern and thickness. The observed endometrial pattern was presence or absence of central cavity echogenicity, triple line sign, endometrial hypoechogenicity, ring sign, endometrial hyperechogenicity and posterior acoustic sonic enhancement. The results were as follows; Central cavity echogenicity was seen throughout menstrual cycle. Triple line sign was observed in 81.1% of patients during early secretory phase. However, in mid to late secretory phase, triple line sign was appeared in only 6.8%. The percentage of positive endometrial hypoechogenicity was highest in early secretory phase. In contrast to hypoechogenicity, positive endometrial hyperechogenicty was highest in mid to late secretory phase. Ring sign was observed in 73.5% of the patients during early secretory phase with peak incidence. Posterior acoustic enhancement was seen in 72.7% of the patients during late secretory phase. The sensitivity and specificity of being a secretory phase if the patients showed hyperechogenic endometrium, were 84.2%, 83.3% respectively. The sensitivity and specificity of being a secretory phase if the patients showed posterior acoustic enhancement were 93.8%, 58.3% respectively. Endometrial thickness was not correlated with endometrial dating. In conclusion, transvaginal ultrasonographical delineation of the endometrial pattern might be useful tool in predicting endometrial status during normal menstrual cycle. But, endometrial thickness could not predict the endometrial dating.

  • PDF

Fabrication of Electrochemical Sensor with Tunable Electrode Distance

  • Yi, Yu-Heon;Park, Je-Kyun
    • JSTS:Journal of Semiconductor Technology and Science
    • /
    • 제5권1호
    • /
    • pp.30-37
    • /
    • 2005
  • We present an air bridge type electrode system with tunable electrode distance for detecting electroactive biomolecules. It is known that the narrower gap between electrode fingers, the higher sensitivity in IDA (interdigitated array) electrode. In previous researches on IDA electrode, narrower patterning required much precise and expensive equipment as the gap goes down to nanometer scale. In this paper, an improved method is suggested to replace nano gap pattering with downsizing electrode distance and showed that the patterning can be replaced by thickness control using metal deposition methods, such as electroplating or metal sputtering. The air bridge type electrode was completed by the following procedures: gold patterning for lower electrode, copper electroplating, gold deposition for upper electrode, photoresist patterning for gold film support, and copper etching for space formation. The thickness of copper electroplating is the distance between upper and lower electrodes. Because the growth rate of electroplating is $0.5{\mu}m\;min^{-1}$, the distance is tunable up to hundreds of nanometers. Completed electrodes on the same wafer had $5{\mu}m$ electrode distance. The gaps between fingers are 10, 20, 30, and $40{\mu}m$ and the widths of fingers are 10, 20, 30, 40, and $50{\mu}m$. The air bridge type electrode system showed better sensitivity than planar electrode.

MEMS 공정 제작방법에 의한 솔레노이드형 여자 코일과 검출코일을 사용한 마이크로 플럭스게이트 센서 (MEMS-BASED MICRO FLUXGATE SENSOR USING SOLENOID EXCITATION AND PICK-UP COILS)

  • 나경원;박해석;심동식;최원열;황준식;최상인
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2002년도 하계학술대회 논문집
    • /
    • pp.172-176
    • /
    • 2002
  • This paper describes a MEMS-based micro-fluxgate magnetic sensing element using Ni$\_$0.8/Fe$\_$0.2/ film formed by electroplating. The micro-fluxgate magnetic sensor composed of a thin film magnetic core and micro-structured solenoids for the pick-up and the excitation coils, is developed by using MEMS technologies in order to take advantage of low-cost, small size and lower power consumption in the fabrication. A copper with 20um width and 3um thickness is electroplated on Cr(300${\AA}$)/Au(1500${\AA}$) films for the pick-up(42turn) and the excitation(24turn) coils. In order to improve the sensitivity of the sensing element, we designed the magnetic core into a rectangular-ring shape to reduce the magnetic flux leakage. An electroplated permalloy film with the thickness of 3 $\mu\textrm{m}$ is obtained under 2000Gauss to induce magnetic anisotropy. The magnetic core has the high DC effective permeability of ∼1,100 and coercive field of -0.1Oe. The fabricated sensing element using rectangular-ring shaped magnetic film has the sensitivity of about 150V/T at the excitation frequency of 2MHz and the excitation voltage of 4.4Vp-p. The power consumption is estimated to be 50mW.

  • PDF

차량진동 및 Rotor 내구특성을 고려한 Brake System 의 최적설계 (Optimal Design of Brake System considering Vehicle Vibration and Durability of Rotor)

  • 김봉수;김희열;김강욱;손영균;이동근;박관흠
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2001년도 춘계학술대회논문집A
    • /
    • pp.764-769
    • /
    • 2001
  • Brake-induced vibrations of a vehicle such as brake judder are determined by the excitation of brake torque variations and by their transfer to the driver's contact points via suspension, body and steering system. The formation of brake torque variation is mainly determined by static and dynamic disk thickness variations. The vibration transfer from the excitation by brake torque variation to the perception by the driver depends on the kinematic and dynamic behaviour of the components in the transfer path. Optimization of the judder performance can be achieved either by minimizing the excitation or by reduction of the judder sensitivity of the vehicle. In this paper, the optimization process of a front rotor is suggested to reduce brake judder considering the cooling performance of the rotor, the judder sensitivity of the vehicle and durability of the rotor.

  • PDF

액정 소자의 위치 민감도 및 수차 특성에 대한 연구 (The Analysis of position Sensitivity and Aberration characteristics of Liquid Crystal Elements)

  • 허태연;유호식;유장훈;박수한;정수진
    • 정보저장시스템학회논문집
    • /
    • 제1권1호
    • /
    • pp.78-83
    • /
    • 2005
  • The Blu-ray disc as a next generation high density optical medium uses an objective lens of high numerical aperture(NA 0.85) and blue laser in order to increase the recording density. The double layer is also useful for doubling the density. The spherical aberration of Blu-ray disc is very sensitive to the thickness of the disk because of high numerical aperture. This paper suggests a method to compensate the spherical aberration caused by the change of disk thickness, by using the Liquid Crystal lens instead of the Liquid Crystal panel. It was possible to develop both the LC panel generating the optical phase difference and LC lens changing the optical power. In this paper, we analyzed the aberration performance and a position sensitivity of the two type LC elements when the samples deviate from the optical axis of the objective lens. The results of applying this analysis show that the LC lenses rather than the LC panels have a significant assembling tolerance. The theoretical characteristics of the two elements are calculated and compared with the measurement data.

  • PDF

High Sensitivity Micro-fabricated Fluxgate Sensor with a Racetrack Shaped Magnetic Core

  • Choi, Won-Youl;Kim, So-Jung
    • Transactions on Electrical and Electronic Materials
    • /
    • 제6권3호
    • /
    • pp.110-114
    • /
    • 2005
  • We present a micro fluxgate magnetic sensor having solenoid coils and racetrack shaped magnetic core, which was designed to decrease the .operating power and magnetic flux leakage. Electroplated copper coils of $6\;{\mu}m$ thickness and the core of $3\;{\mu}m$ thickness were separated by benzocyclobutane (BCB) having a high insulation and good planarization characters. Permalloy $(Ni_{0.8}Fe_{0.2})$ as a magnetic core was also electroplated under 2000 gauss to induce the magnetic anisotropy. The core had the high DC effective permeability of $\~1,300$ and coercive field of $\~0.1$ Oe. The fabricated fluxgate sensor had the very small actual size of $3.0\times1.7\;mm^2$. The fluxgate sensor with a racetrack shaped core had the high sensitivity .of $\~350$ V/T at excitation condition of 3 $V_{P-P}$ and 2 MHz square wave. When two fluxgates were perpendicularly aligned in terrestrial field, their two-axis output signals were very useful to commercialize an electronic azimuth compass for the portable navigation system.