• 제목/요약/키워드: thickness sensitivity

검색결과 643건 처리시간 0.027초

$\gamma$선(線)(Ir-192)이 연박(鉛箔)두께의 증감(增減)에 따른 필름감도(感度) 효과(效果) (A Study on Film Sensitive Effect Influenced by ${\gamma}-ray$(Ir-192) Depending on Thickness of Lead Foil)

  • 주광태
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제2권1호
    • /
    • pp.95-99
    • /
    • 1979
  • When the ${\gamma}-ray$ of average energy 375KeV emitted by Ir-192 is exposed to each film through lead foil with various thickness, the film sensitivity will be different according to the thickness of lead foil and film type. The results on the study, different density and sensitive ratio appeared depending on exposed time and film type, but was made on the following common points. 1. The effect of film sensitivity by the front lead foil showed rapid increase up to the thickness of more or less 0.03mm, and the thicker lead foil was decreased more in the thickness of about $0.05{\sim}0.09mm$. 2. The effect of film sensitivity by the back lead foil was increased up to around of $0.03{\sim}0.08mm$ thickness, the maximum sensitivity was obtained in the thickness of more than $0.03{\sim}0.08mm$ without any change in the above effect. 3. The sensitivity of front lead foil was higher than that of back lead foil in thin lead foil with about 0.127mm thickness, but the sensitivity of back lead foil was higher than that of front lead foil when thickness became thicker.

  • PDF

스퍼터링법으로 제조된 Pd-doped $SnO_2$ 박막의 수소가스 감도 특성 (The Hydrogen Gas Sensing Characteristics of the Pd-doped $SnO_2$ Thin Films Prepared by Sputtering)

  • 차경현;김영우;박희찬;김광호
    • 한국세라믹학회지
    • /
    • 제30권9호
    • /
    • pp.701-708
    • /
    • 1993
  • Pd-doped SnO2 thin films for hydrogen gas sensing were fabricated by reactive fo magnetron sputtering and were studied on effects of film thickness and Pd doping content. Pd doping caused the optimum sensor operation temperature to reduce down to ~25$0^{\circ}C$ and also enhanced gas sensitivity, compared with undoped SnO2 film. Gas sensitivity depended on the film thickness. The sensitivity increased with decreasing the film thickness, showing maximum sensitivities at the thickness of 730$\AA$ and 300~400$\AA$ for the undoped SnO2 and the Pd-doped SnO2 film, respectively. Further decrease of the film thickness beyond these thickness ranges, however, resulted in the reduction of sensitivity again.

  • PDF

섬광체와 평행구멍조준기가 감마프로브 영상에 미치는 영향에 관한 컴퓨터 시뮬레이션 (Computer Simulation for Effects of Scintillator and Parallel Hole Collimator on Gamma Probe Imaging)

  • 봉정균;김희중;이종두;권수일
    • 대한의용생체공학회:의공학회지
    • /
    • 제19권6호
    • /
    • pp.563-570
    • /
    • 1998
  • The purpose of this study was to investigate the effects of scintillator and collimator parameters that tradeoff between system sensitivity and spatial resolution. The parameters simulated using Monte Carlo program were scintillator thickness, colimator hole shape, septal thickness, and hole length. The results show that the sensitivity increases exponentially upto about 1 cm of scintillator thickness as the thickness increases. However the sensitivity is almost constant when the scintiallator is thicker than about 1 cm. The simulation of collimator hole shape shows that the hexagonal hole gives the best spatial resolution for the same system sensitivity. The system statical resolution is improved, as both collimator septal thickness and hole length increase, however that system sensitivity is rapidly decreased. In conclusion, The optimization of scintillator and collimator parameters using monte carlo simulation may be useful to develop a high-resolution miniature gamma probe.

  • PDF

Comparison of Simulated PEC Probe Performance for Detecting Wall Thickness Reduction

  • Shin, Young-Kil;Choi, Dong-Myung;Jung, Hee-Sung
    • 비파괴검사학회지
    • /
    • 제29권6호
    • /
    • pp.563-569
    • /
    • 2009
  • In this paper, four different types of pulsed eddy current(PEC) probe are designed and their performance of detecting wall thickness reduction is compared. By using the backward difference method in time and the finite element method in space, PEC signals from various thickness and materials are numerically calculated and three features of the signal are selected. Since PEC signals and features are obtained by various types and sizes of probe, the comparison is made through the normalized features which reflect the sensitivity of the feature to thickness reduction. The normalized features indicate that the shielded reflection probe provides the best sensitivity to wall thickness reduction for all three signal features. Results show that the best sensitivity to thickness reduction can be achieved by the peak value, but also suggest that the time to peak can be a good candidate because of its linear relationship with the thickness variation.

전구 해빙모델(CICE)을 이용한 해빙 농도와 해빙 두께 민감도 비교 (Sensitivity Study of Simulated Sea-Ice Concentration and Thickness Using a Global Sea-Ice Model (CICE))

  • 이수봉;안중배
    • 대기
    • /
    • 제24권4호
    • /
    • pp.555-563
    • /
    • 2014
  • The impacts of dynamic and thermodynamic schemes used in the Community Ice CodE (CICE), the Los Alamos sea ice model, on sea ice concentration, extent and thickness over the Arctic and Antarctic regions are evaluated. Using the six dynamic and thermodynamic schemes such as sea ice strength scheme, conductivity scheme, albedo type, advection scheme, shortwave radiation method, and sea ice thickness distribution approximation, the sensitivity experiments are conducted. It is compared with a control experiment, which is based on the fixed atmospheric and oceanic forcing. For sea ice concentration and extent, it is found that there are remarkable differences between each sensitivity experiment and the control run over the Arctic and Antarctic especially in summer. In contrast, there are little seasonal variations between the experiments for sea ice thickness. In summer, the change of the albedo type has the biggest influence on the Arctic sea ice concentration, and the Antarctic sea ice concentration has a greater sensitivity to not only the albedo type but also advection scheme. The Arctic sea ice thickness is significantly affected by the albedo type and shortwave radiation method, while the Antarctic sea ice thickness is more sensitive to sea ice strength scheme and advection scheme.

압전 수정진동자의 설계민감도 해석과 위상 최적설계 (Design Sensitivity Analysis and Topology Optimization of Piezoelectric Crystal Resonators)

  • 하윤도;조선호;정상섭
    • 한국전산구조공학회:학술대회논문집
    • /
    • 한국전산구조공학회 2005년도 춘계 학술발표회 논문집
    • /
    • pp.335-342
    • /
    • 2005
  • Using higher order Mindlin plates and piezoelectric materials, eigenvalue problems are considered. Since piezoelectric crystal resonators produce a proper amount of electric signal for a thickness-shear frequency, the objective is to decouple the thickness-shear mode from the others. Design variables are the bulk material densities corresponding to the mass of masking plates for electrodes. The design sensitivity expressions for the thickness-shear frequency and mode shape vector are derived using direct differentiation method(DDM). Using the developed design sensitivity analysis (DSA) method, we formulate a topology optimization problem whose objective function is to maximize the thickness-shear component of strain energy density at the thickness-shear mode. Constraints are the allowable volume and area of masking plate. Numerical examples show that the optimal design yields an improved mode shape and thickness-shear energy.

  • PDF

판형 홀다운스프링 집합체의 탄성강성도 민감도 평가 (Evaluation of an elastic stiffness sensitivity of leaf type HDS)

  • 송기남
    • 대한기계학회논문집A
    • /
    • 제21권8호
    • /
    • pp.1276-1290
    • /
    • 1997
  • The previous elastic stiffness formulas of leaf type holddown spring assemblies(HDSs) have been corrected and extended to be able to consider the point of taper runout for the TT-HDS and all the strain energies for both the TT-HDS and the TW-HDS based on Euler beam theory and Castigliano'stheorem. The elastic stiffness sensitivity of the leaf type holddown spring assemblies was analyzed using the derived elastic stiffness formulas and their gradient vectors obtained from the mid-point formula. As a result of the sensitivity analysis, the elastic stiffness sensitivity at each design variable is quantified and design variables having remarkable sensitivity are identified. Among the design variables, leaf thickness is identified as that of having the most remarkable sensitivity of the elastic stiffness. In addition, it was found that the sensitivity of the leaf type HDS's elastic stiffness is exponentially correlated to the leaf thickness.

Evaluation of BMI as an Obesity Index for Korean

  • Kim, Youngok;Lee, Soon-Young;Kim, Seon-Woo;Kim, Kyung-Hee
    • Journal of Community Nutrition
    • /
    • 제2권2호
    • /
    • pp.129-134
    • /
    • 2000
  • The purpose of the present study is to evaluate the validity of the BMI as an indicator of obesity for Koreans. The usefulness of the BMI to represent overweight and obesity was evaluated by measuring the relative validity of sensitivity and specificity, and was compared with the validity of triceps skinfold thickness(mm). To measure the relative validity of the BMI and triceps skinfold thickness, body fat(%) was used as a reference measure of obesity. The study population included 844 participants aged 20-69 years who resided in Kuri City in Kyunggi province. Participants were measured regarding weight, height, triceps skinfold thickness and body fat. The prevalence of obesity for male subjects was 32.0%, 66.2%, and 0.9%, and for female subjects, 17.6%, 56.1%, 12.4% based on the BMI, triceps skinfold thickness, and body fat(%) respectively. The prevalence of obesity was higher based on the BMI or triceps skinfold thickness than body fat measurement. The sensitivity and specificity of the BMI were 33.3% and 67.9% in male subjects and 77.7% and 90.8% in female subjects. Sensitivity of the BMI was lower, and specificity was higher than those of triceps skinfold thickness. In summary, BMI as an indicator of obesity for Korean showed a tendency of overestimation of obesity prevalence. Therefore, there is a need to develop a more reliable obesity index other than the BMI for Koreans.

  • PDF

Dosimetric Characteristics of Flexible Radiochromic Film Based on LiPCDA

  • Jung, Seongmoon;Cho, Jin Dong;Kim, Jung-in;Park, Jong Min;Choi, Chang Heon
    • 한국의학물리학회지:의학물리
    • /
    • 제32권4호
    • /
    • pp.179-184
    • /
    • 2021
  • This study aimed to determine the optimal thickness of the active layer and scan mode for a flexible radiochromic film (F-RCF) based on the active lithium salt of pentacosa-10,12-diynoic acid (LiPCDA). F-RCFs of 90, 120, 140, and 170-㎛ thickness were fabricated using LiPCDA. Several pieces of the F-RCFs were exposed to doses ranging from 0 to 3 Gy. Transmission and reflection modes were used to scan the irradiated F-RCFs. Their dose-response curves were obtained using a second-order polynomial equation. Their sensitivity was evaluated for both scanning modes, and the uniformity of the batch was also examined. For both the transmission and reflection modes, the sensitivity increased as the film thickness increased. For the reflection mode, the dose response increased dramatically under 1 Gy. The value of the net optical density varied rapidly as the thickness of the film increased. However, the dose-response curves showed a supralinear-curve relationship at doses greater than 2 Gy. The sensitivity of the reflection scan at doses greater than 2 Gy was higher than that of the reflection scan within 0-2 Gy. The sensitivity steadily decreased with increasing doses, and the sensitivity of the two modes was within 0.1 to 0.2 at 2 Gy and was saturated beyond that. For the transmission scan, the sensitivity was approximately 0.2 at 3 Gy. For the intra-batch test result, the maximum net optical density difference of the intra-batch was 5.5% at 2 Gy and 7.4% at 0.2 Gy in the transmission and reflection scans, respectively. In the low-dose range, film thickness of more than 120-㎛ was proper in the transmission mode. In contrast, the transmission mode showed a better result compared to the reflection mode. Therefore, the proper scan mode should be selected according to the dose range.

Verification and Sensitivity Analysis on the Elastic Stiffness of the Leaf Type Holddown Spring Assembly

  • Song, Kee-Nam
    • Nuclear Engineering and Technology
    • /
    • 제30권4호
    • /
    • pp.287-297
    • /
    • 1998
  • The elastic stiffness formula of leaf type holddown spring(HDS) assembly is verified by comparing the values of elastic stiffness with the characteristic test results of the HDS's specimens. The comparisons show that the derived elastic stiffness formula is useful in reliably estimating the elastic stiffness of leaf type HDS assembly. The elastic stiffness sensitivity of leaf type HDS assembly is analyzed using the formula and its gradient vectors obtained from the mid-point formula. As a result of sensitivity analysis, the elastic stiffness sensitivity with respect to each design variable is quantified and design variables of large sensitivity are identified. Among the design variables, leaf thickness is identified as the most sensitive design variable to the elastic stiffness of leaf type HDS assembly. In addition, the elastic stiffness sensitivity, with respect to design variable, is in power-law type correlation to the base thickness of the leaf.

  • PDF