• Title/Summary/Keyword: thermoelectric properties

Search Result 366, Processing Time 0.029 seconds

Band-Gap Energy and Thermoelectric Properties of 90% $Bi_2Te_3-10% Bi_2Se_3$ Single Crystals (90% $Bi_2Te_3-10% Bi_2Se_3$ 단결정의 밴드갭 에너지와 열전특성)

  • Ha, Heon-Pil;Hyeon, Do-Bin;Hwang, Jong-Seung;O, Tae-Seong
    • Korean Journal of Materials Research
    • /
    • v.9 no.4
    • /
    • pp.349-354
    • /
    • 1999
  • The temperature dependences of the Hall coefficient, carrier mobility, electrical resistivity, Seebeck coefficient, thermal conductivity, and figure-of-merit of the undoped and $CdI_2$-doped 90% $Bi_2Te_3-10% Bi_2Se_3$, single crystals, grown by the Bridgman method, have been characterized at temperatures ranging from 77K to 600K. The saturated carrier concentration and degenerate temperature of the undoped 90% $Bi_2Te_3-10% Bi_2Se_3$ single crystal are $5.85\times10_{18}cm^{-3}$ and 127K, respectively. The scattering parameter of the 90% $Bi_2Te_3-10% Bi_2Se_3$ single crystal is determined to b -0.23, and the electron mobility to hole mobility ratio ($\mu_e/\mu_h)$ is 1.45. The bandgap energy at 0K of the 90% <$Bi_2Te_3-10% Bi_2Se_3$ single crystal is 0.200 eV. Adding $CdI_2$as a donor dopant, a maximum figure-of-merit of $3.2\times10^{-3}/K$$CdI_2$-doped specimen.

  • PDF

Powder Characteristics and Thermoelectric Properties of Bi2Te3 Alloys Fabricated by Mechanical Alloying Process (기계적 합금화 공정으로 제조한 Bi2Te3계 합금의 분말특성과 열전특성)

  • 김부양;김희정;오태성;현도빈
    • Proceedings of the Korea Association of Crystal Growth Conference
    • /
    • 1996.06b
    • /
    • pp.311-352
    • /
    • 1996
  • Peltier 효과를 이용한 열전소자는 열응담 감도가 좋고 선택적 냉각이 가능하며 무소음, 무진동 및 소형화의 장점으로 각종 전자부품의 국부냉각소자로 응용되고 있다. 또한 최근 냉매의 사용없이 냉각이 가능한 열전재료를 이용한 자동차나 가정용 에어컨 및 냉장고 등의 각종 냉방시스템의 개발도 크게 주목을 받고 있다. 기존의 Bi2Te3계 단결정 열전재료는 성능지수는 우수하나, 기계적 취약성에 기인하여 소자가공시 수율 저하가 가장 큰 문제점으로 지적되고 있다. 이와 같은 문제점을 해결하기 위해 최근 단결정에 비해 기계적 강도가 우수한 다결정 열전재료의 제조공정에 관한 연구가 활발히 이루어지고 있으며, 그 일환으로 기계적 합금화법을 이용한 열전재료의 제조공정이 연구되고 있다. 원료금속이 고 에너지 볼-밀 내에서의 연쇄적인 파괴와 압접에 의해 합금분말로 변화되는 기계적 합금화 공정은 상온공정으로 이를 사용하여 다결정 열전재료를 제조시 기존의 다결정 열전재료의 제조공정인 "용해 및 분쇄법'과 비교하여 제조단가를 낮출 수 있는 장점이 있다. 본 연구에서는 전자냉각소자용 열전재료로서 상온부근에서 성능지수가 가장 우수한 p형 (Bi,Sb)2Te3 및 n형 Bi2(Te,Se)3 합금분말을 기계적 합금화 공정으로 제조하여 분말 특성을 분석하였으며, 가압소결 후 열전특성의 변화거동을 연구하였다. 순도 99.99% 이상인 Bi, Sb, Te, Se granule을 (Bi1-xSbx)2Te3 및 Bi2(Te1-ySey)3 조성에 맞게 칭량하여 불과 분말의 무게비 5:1로 강구와 함께 공구강 vial에 장입 후, Spex mixer/mill을 이용하여 기계적 합금화 하였다. 기계적 합금화 공정으로 제조한 분말에 대한 X-선 회절분석과 시차 열분석으로 합금화 정도를 분석하였다. (Bi1-xSbx)2Te3 및 Bi2(Te1-ySey)3 합금분말을 10-5 torr의 진공중에서 300℃∼550℃의 온도로 30분간 가압소결하였다. 가압소결체의 파단면에서의 미세구조를 주사전자현미경으로 관찰하였으며, 상온에서 가압소결체의 열전특성을 측정하였다. (Bi1-xSbx)2Te3의 기계적 합금화에 요구되는 공정시간은 Sb2Te3 함량에 따라 증가하여 x=0.5 조성에서는 4 시간 45분, x=0.75 조성에서는 5 시간, x=1 조성에서는 6 시간 45분의 vibro 밀링이 요구되었다. n형 Bi2(Te1-ySey)3 합금분말의 제조에 요구되는 밀링시간 역시 Bi2Se3 함량 증가에 따라 증가하였으며 Bi2(Te0.95Se0.05)3 합금분말의 제조에는 2시간, Bi2(Te0.9Se0.1)3 및 Bi2(Te0.85Se0.15)3 합금분말의 형성에는 3시간의 bivro 밀링이 요구되었다. 기계적 합금화로 제조한 p형 (Bi0.2Sb0.8)2Te3 및 n형 Bi2(Te0.9Se0.1)3 가압 소결체는 각기 2.9x10-3/K 및 2.1x10-3/K 의 우수한 성능지수를 나타내었다.

  • PDF

Thermoelectric Properties and Crystallization of $(Bi1-xSbx)_2Te_3 $ Thin Films Prepared by Magenetron Sputtering Process (마그네트론 스퍼터링법으로 제조한 $(Bi1-xSbx)_2Te_3 $박막의 결정성과 열전특성)

  • 연대중;오태성
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2000.02a
    • /
    • pp.62-62
    • /
    • 2000
  • 비접촉식 온도센서는 물체에서 방출하는 적외선 등의 복사신호를 열에너지로 전환하고 이를 다시 전기신호로 2차 에너지 변환하여 온도를 감지하는 센서로 인체 검지를 응용한 다양한 상품 및 교통, 방재, 빌딩 시스템 등의 분야에 널리 응용되고 있다. 비접촉식 적외선 센서는 열에너지를 전기에너지로 변환하는 방법에 따라 양자형과 열형으로 구분되며, 이중 양자형은 광전도나 광기전력 효과 등을 이용하여 감도 및 응답성이 우수하다는 장점을 지니고 있지만, 소자부를 80K 이하 온도로 유지시키는 냉각을 필요로 하므로 대형 제작이 불가피하고 그 용도가 제한적이다. 열형은 냉각이 필요 없고 소형으로 제작가능한 장점을 지니고 있어 써모 파일이나 초전체를 이용한 번용 센서가 보급되고 있다. 그러나 써모파일의 경우 출력되는 전기 신호가 미약하여 감도 및 응답성을 향상하기 위해 구조가 복잡하고, 특히 모터초퍼나 저항을 전압으로 변환시키는 전력기 등이 필요로 하는 단점을 지니고 있다. 따라서 이러한 문제점을 보완하기 위해 열전재료 박막을 이용한 적외선 센서를 개발하려는 노력이 진행중에 있다. 열전박막을 이용한 적외선 센서는 열전재료의 Seebeck 현상을 이용하여 열에너지에서 전기에너지의 변환이 자가발전으로 이루어져 offset과 외부 바이어스를 필요로 하지 않는다. 또한 작은 온도 변화에도 그 감도와 응답성이 높고, 출력신호가 커서 증폭기 등이 불필요한 장점을 지니고 있다. 특히 초전형 센서가 상온에서도 기판에 대한 열 확산을 제어해야 하는 문제점을 갖는 반면, 열전박막형 적외선 센서는 고온에서도 안정된 출력 신호를 얻을 수 있어 그 활용 온도 범위가 크게 확대될 것으로 기대된다. 본 실험에서는 우수한 열전특성을 갖는 (Bi1-xSbx)2Te3 박막을 얻기 위해 열팽창계수가 작고 알칼리 원소가 0.3% 이하로 포함되어 있는 corning glass(# 7059)를 기판으로 사용하였다. 또한 최적의 열전특성을 나타내는 조성을 실험적으로 구하기 위해 (Bi0.2Sbx)2Te3 조성의 합금 타? 위에 Bi2Te3 및 Sb2Te3 chip을 올려놓고 그 면적을 변화시켜 다양한 조성의 열전박막을 증착하였다. 열전박막의 증착시 산화와 오염에 의한 열전특성 변화를 최소화하기 위해 초기진공도를 1$\times$10-6 Torr로 하였으며, Ar 가스를 흘려주어 2$\times$102 Torr 의 증착진공도를 유지하였다. 열전박막을 증착하기 전에 기판을 10분간 200W의 출력으로 RF 처리하였으며, 30$0^{\circ}C$에서 33 /sec의 속도로 (Bi1-xSbx)2Te3 박막을 증착하였다. 이와 같이 제조된 (Bi1-xSbx)2Te3 박막의 미세구조를 SEM으로 관찰하고 EDS로 조성을 분석하였으며, XRD를 이용하여 결정성을 관찰하였다. 또한 (Bi1-xSbx)2Te3 박막의 Seebeeck 계수 및 전기비저항을 측정하고 증착된 박막조성, 결정상, 미세구조와 열전특성간의 상관관계를 고찰하였다.

  • PDF

Development and Evaluation of Artificial Lightweight Soil Using Bottom Ash (바텀애시를 활용한 인공경량토양의 개발 및 성능 평가)

  • Kim, Chul-Min;Kim, Min-Woo;Cho, Gun-Young;Choi, Na-Rae
    • Journal of the Korean Recycled Construction Resources Institute
    • /
    • v.6 no.4
    • /
    • pp.252-258
    • /
    • 2018
  • A larger energy consumption and concentration of population induced green house gas glowing and heat island effect in the urban space. Roof green system was a effect method to reduce green house gas and heat concentration in the city. Therefore, construction of this system was increasing. Most of lightweight soil used in roof green system was perlite, but this caused dust and skin disease. So it needed to develop another new lightweight soli for roof green system. Meanwhile, a thermoelectric power plant generated bottom ash as a by-product. According to previous research, bottom ash could be used for artificial lightweight soil with 60 wt% of mixing rate. But this study was proceed to develop a artificial lightweight soil using bottom ash with higher mixing rate by 65 wt% and different organic ingredients. First, physical and chemical properties of bottom ash was investigated. Then test according to landscaping design standard was proceeded for various artificial lightweight soil mix types using bottom ash, bark, compost and coco peat. As a result, the artificial lightweight soil with 65% of bottom ash, 30% of bark and 5% of compost was suitable for low and middle range of soil standard.

Recent Progress in Air-Conditioning and Refrigeration Research : A Review of Papers Published in the Korean Journal of Air-Conditioning and Refrigeration Engineering in 2013 (설비공학 분야의 최근 연구 동향 : 2013년 학회지 논문에 대한 종합적 고찰)

  • Lee, Dae-Young;Kim, Sa Ryang;Kim, Hyun-Jung;Kim, Dong-Seon;Park, Jun-Seok;Ihm, Pyeong Chan
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.26 no.12
    • /
    • pp.605-619
    • /
    • 2014
  • This article reviews the papers published in the Korean Journal of Air-Conditioning and Refrigeration Engineering during 2013. It is intended to understand the status of current research in the areas of heating, cooling, ventilation, sanitation, and indoor environments of buildings and plant facilities. Conclusions are as follows. (1) The research works on the thermal and fluid engineering have been reviewed as groups of fluid machinery, pipes and relative parts including orifices, dampers and ducts, fuel cells and power plants, cooling and air-conditioning, heat and mass transfer, two phase flow, and the flow around buildings and structures. Research issues dealing with home appliances, flows around buildings, nuclear power plant, and manufacturing processes are newly added in thermal and fluid engineering research area. (2) Research works on heat transfer area have been reviewed in the categories of heat transfer characteristics, pool boiling and condensing heat transfer and industrial heat exchangers. Researches on heat transfer characteristics included the results for general analytical model for desiccant wheels, the effects of water absorption on the thermal conductivity of insulation materials, thermal properties of Octadecane/xGnP shape-stabilized phase change materials and $CO_2$ and $CO_2$-Hydrate mixture, effect of ground source heat pump system, the heat flux meter location for the performance test of a refrigerator vacuum insulation panel, a parallel flow evaporator for a heat pump dryer, the condensation risk assessment of vacuum multi-layer glass and triple glass, optimization of a forced convection type PCM refrigeration module, surface temperature sensor using fluorescent nanoporous thin film. In the area of pool boiling and condensing heat transfer, researches on ammonia inside horizontal smooth small tube, R1234yf on various enhanced surfaces, HFC32/HFC152a on a plain surface, spray cooling up to critical heat flux on a low-fin enhanced surface were actively carried out. In the area of industrial heat exchangers, researches on a fin tube type adsorber, the mass-transfer kinetics of a fin-tube-type adsorption bed, fin-and-tube heat exchangers having sine wave fins and oval tubes, louvered fin heat exchanger were performed. (3) In the field of refrigeration, studies are categorized into three groups namely refrigeration cycle, refrigerant and modeling and control. In the category of refrigeration cycle, studies were focused on the enhancement or optimization of experimental or commercial systems including a R410a VRF(Various Refrigerant Flow) heat pump, a R134a 2-stage screw heat pump and a R134a double-heat source automotive air-conditioner system. In the category of refrigerant, studies were carried out for the application of alternative refrigerants or refrigeration technologies including $CO_2$ water heaters, a R1234yf automotive air-conditioner, a R436b water cooler and a thermoelectric refrigerator. In the category of modeling and control, theoretical and experimental studies were carried out to predict the performance of various thermal and control systems including the long-term energy analysis of a geo-thermal heat pump system coupled to cast-in-place energy piles, the dynamic simulation of a water heater-coupled hybrid heat pump and the numerical simulation of an integral optimum regulating controller for a system heat pump. (4) In building mechanical system research fields, twenty one studies were conducted to achieve effective design of the mechanical systems, and also to maximize the energy efficiency of buildings. The topics of the studies included heating and cooling, HVAC system, ventilation, and renewable energies in the buildings. Proposed designs, performance tests using numerical methods and experiments provide useful information and key data which can improve the energy efficiency of the buildings. (5) The field of architectural environment is mostly focused on indoor environment and building energy. The main researches of indoor environment are related to infiltration, ventilation, leak flow and airtightness performance in residential building. The subjects of building energy are worked on energy saving, operation method and optimum operation of building energy systems. The remained studies are related to the special facility such as cleanroom, internet data center and biosafety laboratory. water supply and drain system, defining standard input variables of BIM (Building Information Modeling) for facility management system, estimating capability and providing operation guidelines of subway station as shelter for refuge and evaluation of pollutant emissions from furniture-like products.

Recent Progress in Air Conditioning and Refrigeration Research - A Review of Papers Published in the Korean Journal of Air-Conditioning and Refrigeration Engineering in 2004 and 2005 - (공기조화, 냉동 분야의 최근 연구 동향 -2004년 및 2005년 학회지 논문에 대한 종합적 고찰-)

  • Choi, Yong-Don;Kang, Yong-Tae;Kim, Nae-Hyun;Kim, Man-Hoe;Park, Kyoung-Kuhn;Park, Byung-Yoon;Park, Jin-Chul;Hong, Hi-Ki
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.19 no.1
    • /
    • pp.94-131
    • /
    • 2007
  • A review on the papers published in the Korean Journal of Air-Conditioning and Refrigerating Engineering in 2004 and 2005 has been done. Focus has been put on current status of research in the aspect of heating, cooling, air-conditioning, ventilation, sanitation and building environment. The conclusions are as follows. (1) Most of fundamental studies on fluid flow were related with heat transportation of facilities. Drop formation and rivulet flow on solid surfaces were interesting topics related with condensation augmentation. Research on micro environment considering flow, heat, humidity was also interesting for comfortable living environment. It can be extended considering biological aspects. Development of fans and blowers of high performance and low noise were continuing topics. Well developed CFD and flow visualization(PIV, PTV and LDV methods) technologies were widely applied for developing facilities and their systems. (2) The research trends of the previous two yews are surveyed as groups of natural convection, forced convection, electronic cooling, heat transfer enhancement, frosting and defrosting, thermal properties, etc. New research topics introduced include natural convection heat transfer enhancement using nanofluid, supercritical cooling performance or oil miscibility of $CO_2$, enthalpy heat exchanger for heat recovery, heat transfer enhancement in a plate heat exchanger using fluid resonance. (3) The literature for the last two years($2004{\sim}2005$) is reviewed in the areas of heat pump, ice and water storage, cycle analysis and reused energy including geothermal, solar and unused energy). The research on cycle analysis and experiments for $CO_2$ was extensively carried out to replace the Ozone depleting and global warming refrigerants such as HFC and HCFC refrigerants. From the year of 2005, the Gas Engine Heat Pump(GHP) has been paid attention from the viewpoint of the gas cooling application. The heat pipe was focused on the performance improvement by the parametric analysis and the heat recovery applications. The storage systems were studied on the performance enhancement of the storage tank and cost analysis for heating and cooling applications. In the area of unused energy, the hybrid systems were extensively introduced and the life cycle cost analysis(LCCA) for the unused energy systems was also intensively carried out. (4) Recent studies of various refrigeration and air-conditioning systems have focused on the system performance and efficiency enhancement. Heat transfer characteristics during evaporation and condensation are investigated for several tube shapes and of alternative refrigerants including carbon dioxide. Efficiency of various compressors and expansion devices are also dealt with for better modeling and, in particular, performance improvement. Thermoelectric module and cooling systems are analyzed theoretically and experimentally. (5) According to the review of recent studies on ventilation systems, an appropriate ventilation systems including machenical and natural are required to satisfied the level of IAQ. Also, an recent studies on air-conditioning and absorption refrigeration systems, it has mainly focused on distribution and dehumidification of indoor air to improve the performance were carried out. (6) Based on a review of recent studies on indoor environment and building service systems, it is noticed that research issues have mainly focused on optimal thermal comfort, improvement of indoor air Quality and many innovative systems such as air-barrier type perimeter-less system with UFAC, radiant floor heating and cooling system and etc. New approaches are highlighted for improving indoor environmental condition as well as minimizing energy consumption, various activities of building control and operation strategy and energy performance analysis for economic evaluation.