• Title/Summary/Keyword: thermocouple

Search Result 360, Processing Time 0.022 seconds

A Study on the Flow Conditions of the Combustion Air Heater Outlet for the Supersonic Combustion Experiment (초음속 연소 실험을 위한 연소식 공기 가열기 출구 유동 조건 실험 연구)

  • Lee, Eun Sung;Han, Hyung-Seok;Lee, Jae Hyuk;Choi, Jeong-Yeol
    • Journal of the Korean Society of Propulsion Engineers
    • /
    • v.26 no.1
    • /
    • pp.88-97
    • /
    • 2022
  • In this study, a vitiated air heater was designed and manufactured to supply high-temperature and high-pressure air to the ground test apparatus of a direct-connected supersonic combustor, and an experiment was performed to verify the target design point. By installing wedges at the upper boundary, lower boundary and center of the nozzle exit of the vitiated air heater, it was confirmed that the Mach number satisfies the 2.0 level, and the pressure of the combustion chamber was also satisfactory compared to the design point. In the case of temperature, the measured temperature deviation was large due to the degree of exposure of the thermocouple and the slow response characteristics. After that, the isolator was connected to the rear of the vitiated air heater, and the Mach number was measured in the same method, and the Mach number at the center of the isolator eixt was slightly reduced to 1.8~1.9.

A Study on the Fire Risk of High-voltage Cables for Electrical Vehicles (전기차용 고전압 케이블의 화재 위험성에 관한 연구)

  • Sin Dong Kang;Ye Jin Park;Si Hyun Kim;Jae-Ho Kim
    • Journal of the Korean Society of Safety
    • /
    • v.38 no.4
    • /
    • pp.8-14
    • /
    • 2023
  • This study presents the characteristics of short circuits (SCs) caused by excessive currents in high-voltage cables used in electric vehicles and emphasizes the need to calculate the cross-sectional areas of these cables according to the SC current. Three direct current power supplies were connected in parallel to test the SC characteristics caused by excessive currents, and a timer and a magnetic contactor were used to deliver the conduction time and SC current. A circular infrared-radiation heater was used to test the temperature-dependent SC characteristics, a thermocouple was used to measure the temperature, and a shunt resistor was used to measure the current. As the SC current increased, the fusing time of the cable decreased. Additionally, a high-voltage cable (with an area of 16 mm2 ) used in electric vehicles fused when a current (approximately equal to 55 times the allowable current) flowed for 0.2 s (operating time of the protective device). When the SC current is 10 kA, the cable may fuse during the operating time of the protective device, thus creating a fire hazard. In electric vehicles, the size of the SC current increases in proportion to the capacity of the battery. Thus, the cross-sectional areas of the cables used should be calculated accordingly, and cable operations should be properly coordinated with the surrounding protective devices.

Histologic Effects of a Contact Diode Laser on Intraoral Soft Tissue (접촉식 다이오드레이저조사가 구강연조직에 미치는 조직학적 영향)

  • White, Joel M.;Shin, Keum-Back;Thompson, Rick;Myers, Terry D.
    • Journal of Oral Medicine and Pain
    • /
    • v.23 no.2
    • /
    • pp.101-108
    • /
    • 1998
  • 본 연구는 두 가지 관점, 즉 다이오드레이저를 구강연조직에 접촉식으로 조사하여 조직을 절제할 경우 첫째 심부조직에서의 온도 상승 정도에 대한 분석 평가, 둘째 절제에 따른 조직의 열적 응고에 대한 조직학적 분석 평가를 위해 시도되었다. 연구를 위해 도축된 소의 혀 배면으로부터 5.0mm깊이에 T형 열전대(type T thermocouple)를 설치하고 조사조건에 따른 레이저절제 도주의 온도변화를 측정하고, 또한 해당조사부위의 조직을 대상으로 통법에 의한 H-E염색 후 조직학적 측면에서 열적 응고상을 검색하여 Nd:YAG레이저의 경우에서와 비교하였다. 즉 파장815nm의 다이오드레이저를 0-10W의 출력, 50Hz와 연속파의 주파수조건에서 접촉식으로 조사하였으며, 또한 파장1064nm의 Nd:YAG레이저를 0-10W의 출력, 50Hz와 100Hz의 주파수 조건에서 접촉식으로 조사하였다. 레이저의 접촉조사시 레이저광섬유 첨단부에서 10(10gm의 일정한 압력과 25mm/sec의 이동속도로 조직을 절제하였다. 레이저가 접촉조사된 조직부위를 통법에 의해 조직학적으로 H-E염색을 시행하였으며, 계측현미경을 이용하여 10배율 아래에서 조직절제의 폭과 깊이, 측방 및 하방 쪽으로 열적 응고의 폭을 계측하였다. 계측치에 대한 통계학적 처리결과 조직절제의 폭과 측방쪽으로 열적응고의 폭은 다이오드레이저에와 Nd:YAG레이저에서 같은 정도를 나타냈다. 조직절제의 깊이는 Nd:YAG레이저에서에 비해 다이오드레이저에서 더 깊었다. 하방쪽으로의 열적응고의 폭은 Nd:YAG레이저를 10Hz의 조건에서 조사한 경우에서 가장 넓었으며, 다이오드레이저를 50Hz와 연속파의 조건에서 조사한 경우에서 가장 좁았다. 레이저절제 도중 심부조직에서의 온도변화는 다이오드 레이저에서와 Nd:YAG레이저에서 모두 출력이 증가함에 따라 상승되었으며, 다이오드레이저에서 보다 Nd:YAG레이저에서 더 높이 상승되었다. 결론적으로 본 연구에서 시도된 조사조건 범위 이내에서는 구강연조직 절제시 다이오드레이저가 펄스형 광섬유 전달식 Nd:YAG레이저 보다 심부조직에서의 낮은 온도상승과 하방쪽으로의 좁은 열적 응고의 폭을 보이면서 우수한 조직절제효과를 나타냈다.

  • PDF

An Experimental Study on the Measurement of Water Surface Discharge Temperature of High-Temperature Bubble Injected into Cylindrical Acrylic Water Tank (원통 아크릴 수조로 주입된 고온 기포의 수면 배출 온도 측정에 관한 실험적 연구)

  • SeokTae Yoon;YongJin Cho
    • Journal of Korea Society of Industrial Information Systems
    • /
    • v.28 no.6
    • /
    • pp.99-105
    • /
    • 2023
  • Submarines, which require a high degree of survivability, are among the most critical combat weapon systems in military strategic assets. Conventional submarines need air to operate their propulsion systems. Exhaust gases released into the water during snorkel navigation heat the surrounding fluid, producing a temperature wake. This wake, in turn, reduces the submarine's survivability. In this study, we conducted a preliminary experiment on the temperature traces formed by an underwater submarine's waste discharge. For this purpose, we collected propulsion system and navigation condition data from domestically introduced submarines and developed an experimental system to measure the temperature traces. As a result, we observed that high-temperature bubbles injected into the tank broke down into smaller sizes, and their temperature dropped to levels similar to the surrounding fluid. This observation was confirmed using a thermocouple sensor. Consequently, the thermal imaging system designed to measure the temperature trace of the water's surface did not detect any significant temperature traces.

Derivation of Optimal Design Variables Considering Carbon Monoxide Emission Characteristics of Commercial Gas Stove Burners (업소용 가스레인지 버너의 일산화탄소 배출 특성을 고려한 최적 설계변수 도출)

  • Il Kon Kim;Taehoon Kim
    • Journal of the Korean Society of Safety
    • /
    • v.39 no.1
    • /
    • pp.1-8
    • /
    • 2024
  • Commercial gas stoves feed primary air to the burner and burn the fuel-air mixture in a partially premixed combustion. This mechanism produces carbon monoxide during combustion. In this study, design parameters of a commercial gas stove were optimized by considering the carbon monoxide emission. Gas consumption rate, carbon monoxide emission, and water boiling temperature as a heating performance were determined. Carbon monoxide emission was measured using a Korean Industrial Standards standard collector. Water boiling temperature was measured by first soaking the pot in water for approximately 10 min and then heating the pot filled with water. A thermocouple was installed inside the pot. Carbon monoxide increased as the nozzle diameter was increased and the burner-pot height was decreased. This result was due to the insufficient mixing between the fuel and air. Heating performance was enhanced when the nozzle diameter was increased and the burner-pot height was decreased. However, the heating performance deteriorated when the nozzle diameter was 1.8 mm and the burner-pot height was reduced to 50 mm. This phenomenon was due to the formation of a flame on the side of the pot. A merit factor was defined to find the optimal design parameters to satisfy gas consumption rate, carbon monoxide emission, and heating performance. Optimal design values were established to be a nozzle diameter of 1.5 mm and a burner-pot height of 60 mm.

STRAIN AND TEMPERATURE CHANGES DURING THE POLYMERIZATION OF AUTOPOLYMERIZING ACRYLIC RESINS

  • Ahn Hyung-Jun;Kim Chang-Whe;Kim Yung-Soo
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.39 no.6
    • /
    • pp.709-734
    • /
    • 2001
  • The aims of this experiment were to investigate the strain and temperature changes simultaneously within autopolymerzing acrylic resin specimens. A computerized data acquisition system with an electrical resistance strain gauge and a thermocouple was used over time periods up to 180 minutes. The overall strain kinetics, the effects of stress relaxation and additional heat supply during the polymerization were evaluated. Stone mold replicas with an inner butt-joint rectangular cavity ($40.0{\times}25.0mm$, 5.0mm in depth) were duplicated from a brass master mold. A strain gauge (AE-11-S50N-120-EC, CAS Inc., Korea) and a thermocouple were installed within the cavity, which had been connected to a personal computer and a precision signal conditioning amplifier (DA1600 Dynamic Strain Amplifier, CAS Inc., Korea) so that real-time recordings of both polymerization-induced strain and temperature changes were performed. After each of fresh resin mixture was poured into the mold replica, data recording was done up to 180 minutes with three-second interval. Each of two poly(methyl methacrylate) products (Duralay, Vertex) and a vinyl ethyl methacrylate product (Snap) was examined repeatedly ten times. Additionally, removal procedures were done after 15, 30 and 60 minutes from the start of mixing to evaluate the effect of stress relaxation after deflasking. Six specimens for each of nine conditions were examined. After removal from the mold, the specimen continued bench-curing up to 180 minutes. Using a waterbath (Hanau Junior Curing Unit, Model No.76-0, Teledyne Hanau, New York, U.S.A.) with its temperature control maintained at $50^{\circ}C$, heat-soaking procedures with two different durations (15 and 45 minutes) were done to evaluate the effect of additional heat supply on the strain and temperature changes within the specimen during the polymerization. Five specimens for each of six conditions were examined. Within the parameters of this study the following results were drawn: 1. The mean shrinkage strains reached $-3095{\mu}{\epsilon},\;-1796{\mu}{\epsilon}$ and $-2959{\mu}{\epsilon}$ for Duralay, Snap and Vertex, respectively. The mean maximum temperature rise reached $56.7^{\circ}C,\;41.3^{\circ}C$ and $56.1^{\circ}C$ for Duralay, Snap, and Vertex, respectively. A vinyl ethyl methacrylate product (Snap) showed significantly less polymerization shrinkage strain (p<0.01) and significantly lower maximum temperature rise (p<0.01) than the other two poly(methyl methacrylate) products (Duralay, Vertex). 2. Mean maximum shrinkage rate for each resin was calculated to $-31.8{\mu}{\epsilon}/sec,\;-15.9{\mu}{\epsilon}/sec$ and $-31.8{\mu}{\epsilon}/sec$ for Duralay, Snap and Vertex, respectively. Snap showed significantly lower maximum shrinkage rate than Duralay and Vertex (p<0.01). 3. From the second experiment, some expansion was observed immediately after removal of specimen from the mold, and the amount of expansion increased as the removal time was delayed. For each removal time, Snap showed significantly less strain changes than the other two poly(methyl methacrylate) products (p<0.05). 4. During the external heat supply for the resins, higher maximum temperature rises were found. Meanwhile, the maximum shrinkage rates were not different from those of room temperature polymerizations. 5. From the third experiment, the external heat supply for the resins during polymerization could temporarily decrease or even reverse shrinkage strains of each material. But, shrinkage re-occurred in the linear nature after completion of heat supply. 6. Linear thermal expansion coefficients obtained from the end of heat supply continuing for an additional 5 minutes, showed that Snap exhibited significantly lower values than the other two poly(methyl methacrylate) products (p<0.01). Moreover, little difference was found between the mean linear thermal expansion coefficients obtained from two different heating durations (p>0.05).

  • PDF

Streptococcus Mutans Biofilm Inhibition Effect of Indocyanine Green and Near Infrared Diode Laser (Indocyanine Green과 근적외선 다이오드 레이저의 Streptococcus mutans 세균막에 대한 억제 효과)

  • Kim, Yeowon;Park, Howon;Lee, Juhyun;Seo, Hyunwoo;Lee, Siyoung
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.47 no.4
    • /
    • pp.446-453
    • /
    • 2020
  • The purpose of this study was to evaluate the effect of Indocyanine Green (ICG) and near-infrared (NIR) diode laser on Streptococcus mutans biofilms depending on ICG concentrations. S. mutans biofilms were formed on a Hydroxyapatite disk, and 0.5, 1.0, 2.0, 3.0, 4.0, 5.0 mg/mL ICG solutions dissolved in sterile distilled water and a NIR diode laser having a power of 300 mW and a wavelength of 808 nm were applied to the biofilms. The temperature changes of the biofilm surface according to the concentrations of the ICG solution were measured using a 1-channel thermocouple thermometer. Compared to the control group, in the groups with only the 3.0, 4.0, 5.0 mg/mL ICG solution application, and in the groups with the 1.0, 2.0, 3.0, 4.0, 5.0 mg/mL ICG solution application and light irradiation, a statistically significant decrease in the bacterial counts were observed. The temperature increase according to the concentration of the ICG solutions was 9.53℃, 10.43℃, 11.40℃, 12.10℃, 12.67℃, and 13.63℃ in ICG solutions of 0.5, 1.0, 2.0, 3.0, 4.0, and 5.0 mg/mL respectively. This study presents the potential for clinical application of ICG and NIR diode lasers as a new method for preventing dental caries.

Experimental Study for the Capacity of Ordinary and Emergency Ventilation System in Deeply Underground Subway Station (대심도 지하역사 승강장 및 대합실 평상시/비상시 급·배기 풍량에 대한 실험적 연구)

  • Jang, Yong-Jun;Lee, Ho-Seok;Park, Duck-Shin
    • Journal of the Korean Society for Railway
    • /
    • v.15 no.6
    • /
    • pp.579-587
    • /
    • 2012
  • Shin-gumho station in Seoul underground subway have been selected to be experimentally investigated and analyzed for the real air supply & exhaust capacity compared to the original capacity of ordinary and emergency condition. The depth of Shin-gumho station is 43.6m which consists of the island-type platform ($8^{th}$ floor in underground) and a two-story lobby (first & second floor in underground). An emergency staircase connects between the platform and the lobby. Hot-wire anemometer, capture hood, wind vane & velocity meter and data acquisition systems are employed to perform the automatic measurement in this experiment. For ordinary case, air supply and exhaust capacity in the lobby were reduced by 34% and 46% compared to the original capacity, respectively. Air supply and exhaust capacity in the platform were reduced by 66% and 38%, respectively. For emergency case, air supply in the lobby was reduced by 42% and air exhaust in the platform was reduced by 28% compared to the original capacity. Therefore, air pollution in the station is expected to be worse in the ordinary environment and smoke control capability in the platform will be weakened in case of fire emergency.

In-Vivo Heat Transfer Measurement using Proton Resonance Frequency Method of Magnetic Resonance Imaging (자기 공명영상 시스템의 수소원자 공명 주파수법을 이용한 생체 내 열 전달 관찰)

  • 조지연;조종운;이현용;신운재;은충기;문치웅
    • Journal of the Institute of Electronics Engineers of Korea SC
    • /
    • v.40 no.3
    • /
    • pp.172-180
    • /
    • 2003
  • The purpose of this study is to observe the heat transfer process in in-vivo human muscle based on Proton Resonance Frequency(PRF) method in Magnetic Resonance Imaging(MRI). MRI was obtained to measure the temperature variation according to the heat transfer in phantom and in-vivo human calf muscle. A phantom(2% agarose gel) was used in this experiment. MR temperature measurement was compared with the direct temperature measurement using a T-type thermocouple. After heating agarose gel to more than 5$0^{\circ}C$ in boiling hot water, raw data were acquired every 3 minutes during one hour cooling period for a phantom case. For human study heat was forced to deliver into volunteer's calf muscle using hot pack. Reference data were once acquired before a hot pack emits heat and raw data were acquired every 2 minutes during 30minutes. Acquired raw data were reconstructed to phase-difference images with reference image to observe the temperature change. Phase-difference of the phantom was linearly proportional to the temperature change in the range of 34.2$^{\circ}C$ and 50.2$^{\circ}C$. Temperature resolution was 0.0457 radian /$^{\circ}C$(0.0038 ppm/$^{\circ}C$) in phantom case. In vivo-case, mean phase-difference in near region from the hot pack is smaller than that in far region. Different temperature distribution was observed in proportion to a distance from heat source.

The Effect of Heat Therapy on Cutaneous Blood Flow and Skin Temperature at Pre-auricular Region (온열요법이 전이부의 표층부 혈류량과 피부 온도에 미치는 영향)

  • Kim, Su-Beom;Kim, Young-Jun;Kim, Cheul;Park, Moon-Soo
    • Journal of Oral Medicine and Pain
    • /
    • v.30 no.4
    • /
    • pp.401-410
    • /
    • 2005
  • The purpose of this study was to assess the effect of heat therapy on cutaneous blood flow and skin temperature at pre-auricular region. Moist heat therapy and ultrasound therapy were applied to 20 healthy subjects(male: 10, female: 10). Cutaneous blood flow and skin temperature before and after heat therapy were measured with laser doppler flowmetry and thermocouple. The results were as follows ; 1. Cutaneous blood flow and skin temperature were significantly increased after moist heat therapy and ultrasound therapy. 2. In application of moist heat therapy, cutaneous blood flow and skin temperature were more increased and maintained longer than in ultrasound therapy. 3. Before heat therapy, cutaneous blood flow and skin temperature were higher in male. 4. There was no significant gender difference in changes of cutaneous blood flow and skin temperature after heat therapy. In conclusion, both moist heat therapy and ultrasound therapy increased cutaneous blood flow and skin temperature significantly, and moist heat therapy was more effective to increase cutaneous blood flow and skin temperature and to maintain increased cutaneous blood flow and skin temperature. There was no significant gender difference in the effect of heat therapy on cutaneous blood flow and skin temperature.