• Title/Summary/Keyword: thermal stimulation device

Search Result 13, Processing Time 0.022 seconds

The Effects of Functional Electrical Stimulation on Abdominal Obesity Improvement of Adult Women by EMG, Ultrasound and DITI (근전도, 초음파와 DITI를 이용한 전기자극의 성인여성 복부비만 개선 효과 관찰)

  • Lee, Hyun-Ju;Tae, Ki-Sik
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.31 no.11
    • /
    • pp.1051-1058
    • /
    • 2014
  • In this study, we investigated the improvement effect of obesity by treatment with a developed low frequency electrical stimulation system. Thirty female in their 20's as an experiment subjects divided 3 groups(control, commercialized device, developed device) were treated with electrical stimulation on abdomen for 4 weeks. The body weight, body mass index(BMI), waist-hip ratio(WHR), muscle strength, muscle(transverse abdominis(TrA), internal obliquus abdominis(IO), external obliquus abdominis(EO)), fat thickness and abdominal surface temperature were measured by electromyogram(EMG), ultrasound and digital infrared thermal image(DITI). In the result, the body weight and BMI were decreased. Subcutaneous abdominal fat were significantly reduced after 4 weeks. The muscle strength and TrA muscle thickness was increased 13.2%(p<0.05), and 35.5%, respectively. The fat thickness showed decrease in abdomen (p<0.05). Infrared measurement on abdominal surface temperature as a parameter of improvement in blood circulation was significantly increased(p<0.05). Therefore, the low frequency stimulation showed positive effects on parameters of the obesity improvement.

The Current State of Intended Equipment for Heating in Medical Use Based on Domestic Licensed Medical Devices (국내 인·허가 온열의료기기 기술 현황 조사 및 분석)

  • Su-Ran Lim;Jung-Hwan Park;Ji-Yeun Park;Song-Yi Kim
    • Korean Journal of Acupuncture
    • /
    • v.40 no.4
    • /
    • pp.156-168
    • /
    • 2023
  • Objectives : This study aimed to determine the status of thermal stimulation devices approved in Korea for medical applications over the past 10 years, and based on this, to obtain insight for future thermal treatment in Korean medical institutions. Methods : We searched the item classification list entitled "Regulations on Medical Device Items and Rating by Item" from the Ministry of Food and Drug Safety Notice No. 2021-24, 2021 (Enforced March 19, 2021; www.mfds.go.kr) for individually licensed heaters using the terms "heat" and "heating". Results : We identified 17 items of thermal stimulation product group, of which 1,308 devices were licensed by February 4, 2022, and 53.2% of them (n=696) were devices with valid permits for distribution in Korea. Among the licensed devices, heating pad systems under/overlay (electric, home use) were approved the most, but combinational stimulator (for medical use, home use; Grade 2) accounted for the highest percentage among the current valid permission. Moxibustion apparatuses were licensed separately for electrical use and non-electrical use, and occupied a low percentage of the total devices. We analyzed 307 devices that were accompanied by technical documents and found that the heat sources were wires in 145 (47.2%), infrared rays in 44 (14.3%) and ultrasonic waves in 42 (13.7%) devices. Most (83.1%) devices were used for pain relief, while other applications included beauty, cancer treatment, maintenance of infant body temperature, and healing fractures. Conclusions : Thermal stimulation devices accounted for about 0.9% of all medical devices, and among them, combinational stimulators and heating pad systems under/overlay had the most valid permits. Thermal stimulation devices using heating wires and infrared rays were the most prevalent, and most were used to relieve pain. In order to develop a range of thermal stimulation devices that can be utilized in Korean medical institutions, it is imperative that they have potential applications beyond pain management, addressing various medical purposes. To achieve this, foundational research is necessary to effectively apply diverse heat sources based on medical objectives.

Measurement of Internal Temperature Distribution for the Evaluation of Focused Ultrasound (FUS) Stimulation Devices (집속초음파 자극기의 성능평가를 위한 팬텀 내부온도 측정)

  • Doh, Il;Joe, Daniel J.;Kim, Sung Mok;Baik, Kyung Min;Kim, Yong Tae;Park, Seung Min
    • Journal of Biomedical Engineering Research
    • /
    • v.43 no.3
    • /
    • pp.147-152
    • /
    • 2022
  • This research is to measure real-time temperature distribution inside a tissue-mimicking phantom for the safety and effectiveness evaluations of focused ultrasound (FUS) device capable of linear scanning stimulation. Since the focusing area of the FUS stimulation device is smaller than diameter of conventional thermal probe and keeps moving, it is impossible to monitor temperature distribution inside the phantom. By using the phantom with a thin film temperature sensor array inserted, real-time temperature change caused by the FUS device was measured. The translation of the measured temperature peak was also tracked successfully. The present phantom had been experimentally proven to be applicable to validate the performance and safety of the therapeutic ultrasound devices.

Development of a Personal Compound Stimulus Device for Skin-care (개인용 피부미용 복합자극기 개발)

  • Lee, Jeon;Kim, Chi-Hyun;Chung, Geum-Hee
    • Journal of the Institute of Electronics Engineers of Korea SC
    • /
    • v.49 no.1
    • /
    • pp.12-19
    • /
    • 2012
  • Recently, the market of skin-care device has been steadily growing up. In this paper, we tried to develop a personal compound stimulus device more competitive than existing products. As the compound stimulus, biochemical stimulus of herbal extraction fluid, thermal stimulus of plate-shaped carbon fiber heater, and optical stimulus of near infrared LED were selected. By some evaluation tests, the thermal stimulation part and the optical stimulation part were found to be developed properly. Additionally, the efficacy of the mixed stimulus of thermal and optical stimulation was tested in C2C12 mouse myoblast. Through RT-PCR analysis, it was found that, by the developed compound stimulus, the expression of collagen I mRNA and collagen III mRNA increased by 4.9 and 1.3 times respectively.

Preliminary Study for the Comparison of the Skin Temperature Changes by the Combustible Moxibustion and the Electronic Moxibustion Device (연소식 뜸과 전자식 뜸치료 시스템에 의한 체표 온도변화 비교를 위한 사전연구)

  • Chae, Han;Noh, Seung-Hee;Kim, Yu-Ri;Jung, Hae-Ree;Ha, Hyun-Yee;Kim, Kun-Hyung;Yang, Gi-Young;Kim, Jae-Kyu;Lee, Byung-Ryul
    • Journal of Acupuncture Research
    • /
    • v.29 no.3
    • /
    • pp.1-8
    • /
    • 2012
  • Objectives : The purpose of this study was to compare the skin temperature changes by the rechargeable and programmable electronic moxibustion device(EMD) with the traditional combustible moxibustion device(CMD). Methods : Skin temperature changes in six healthy volunteers induced by CMD and EMD were measured with digital infrared thermal imaging(DITI). Heat stimulation was applied on $LI_4$ and $TE_5$, and skin temperature changes on each point were measured at baseline and per minute for total 7 minutes, 2 minutes of heat stimulation and 5 minutes of observation. Results : There was no significant difference in the skin temperature changes between CMD and EMD. The temperature on $LI_4$ with EMD was $32.3{\pm}1.3^{\circ}C$ at baseline, $34.0{\pm}1.3^{\circ}C$ at 1 minute after heat stimulation start, $34.6{\pm}1.2^{\circ}C$ at 2 minutes after, and from 3 minutes after heat stimulation, it maintained $32.6{\sim}32.8^{\circ}C$. Conclusions : Methods for measuring skin temperature changes induced by heat stimulation of moxibustion were established, and the possibility of effectiveness of the newly developed electronic moxibustion device was raised with this preliminary study. This study can contribute to the development of clinical research methodology for traditional Korean medicine.

A Comparative Study of External & Central Temperature Characteristics during the Moxibustion Period (애주 연소 과정에서 발생하는 애주의 표면 및 중심부의 온도변화 특성 연구)

  • Hong, Deok;Kwon, Oh-Sang;Kim, Young-Jin;Kim, Yu-Lee;Kim, Jae-Hyo;Ahn, Seong-Hun;Sohn, In-Chul
    • Korean Journal of Acupuncture
    • /
    • v.27 no.3
    • /
    • pp.47-56
    • /
    • 2010
  • Objectives : The moxibustion is the method using the heat stimulation done by attached and burned a moxa on a healing point or acupuncture point with chemical stimulation of a resin made from burning them. The purpose of this study is to find the physical and thermal characteristics of moxibustion in order to standardize the moxa therapy method. Methods : In this study, the thermal changes were observed by means of a testo 845 device, which is an infra-red thermometer to measure the thermal changes. Results & Conclusions : 1. The thermal changes on the external surface of moxibustion did not depend on the weight of the moxa; the external surface temperature was about $500^{\circ}C$. 2. The central thermal changes depend on the weight of moxa; the central temperatures ranged from $500^{\circ}C$ to $700^{\circ}C$. 3. The burning duration of moxibustion depend on the weight of moxa but that of external surface temperature did not depend on the weight of moxa in high degree : about $400^{\circ}C$. 4. The integral values of central and external temperature curves were proportional to the weight of moxa; that is central temperature curves were higher than that of external.

Effects of Walking with Non-Electric Power Vibration Shoes on Body Temperature and Peripheral Circulation (무전력형 진동신발 보행이 체온과 말초 혈액순환에 미치는 영향)

  • Lee, Hyun Ju;Lee, Cheong Gn;Tae, Ki Sik
    • Journal of Biomedical Engineering Research
    • /
    • v.40 no.6
    • /
    • pp.235-241
    • /
    • 2019
  • The purpose of this study was to investigate the effect of the body temperature peripheral circulation with vibration shoes in healthy 10 adults. The magnetic vibration device with non-electric power was mounted in the midsole of the vibration shoes. The experiment was divided into two groups: vibration shoes and no vibration shoes. Subjects were randomly selected and measured body surface temperature by digital infrared thermal imaging (DITI) and non-invasive capillaries change by nailfold microscope (NFM). After walking in a treadmill for 15 minutes at 4.0 km/h speed wearing normal shoes or vibration shoes, DITI and NFM were measured. The walking with vibration shoes showed the body surface temperature shift from the proximal to the distal. In addition, the diameter of the nailfold capillary in the vibration shoes group was thicker and clearer due to the increased blood flow than that of the no vibration shoes group. The vibration shoes are easy to apply to anyone who can walk because it can give vibration stimulation by walking without additional time, cost, and effort in daily life. Further studies are needed to explain the physiological effects of vibration frequency and intensity on the long-term perspective of target subjects resulting from vascular dysfunction.

Health effects of electromagnetic fields on children

  • Moon, Jin-Hwa
    • Clinical and Experimental Pediatrics
    • /
    • v.63 no.11
    • /
    • pp.422-428
    • /
    • 2020
  • In today's world, most children are exposed to various manmade electromagnetic fields (EMFs). EMFs are electromagnetic waves less than 300 GHz. A developing child's brain is vulnerable to electromagnetic radiation; thus, their caregivers' concerns about the health effects of EMFs are increasing. EMF exposure is divided into 2 categories: extremely low frequencies (ELFs; 3-3,000 Hz), involving high-voltage transmission lines and in-house wiring; and radiofrequencies (RFs; 30 kHz to 300 GHz), involving mobile phones, smart devices, base stations, WiFi, and 5G technologies. The biological effects of EMFs on humans include stimulation, thermal, and nonthermal, the latter of which is the least known. Among the various health issues related to EMFs, the most important issue is human carcinogenicity. According to the International Agency for Research on Cancer's (IARC's) evaluation of carcinogenic risks to humans, ELFs and RFs were evaluated as possible human carcinogens (Group 2B). However, the World Health Organization's (WHO's) view of EMFs remains undetermined. This article reviews the current knowledge of EMF exposure on humans, specifically children. EMF exposure sources, biological effects, current WHO and IARC opinions on carcinogenicity, and effects of EMF exposures on children will be discussed. As well-controlled EMF experiments in children are nearly impossible, scientific knowledge should be interpreted objectively. Precautionary approaches are recommended for children until the potential health effects of EMF are confirmed.

Investigation of the Temperature Change and Quantity of Heat Stimulus of the Commercial Indirect Moxibustion (상용 간접구의 연소형태와 열자극량에 대한 연구)

  • Kwon, O-Sang;Lee, Sang-Hun;Cho, Sung-Jin;Choi, Kwang-Ho;Choi, Sun-Mi;Ryu, Yeon-Hee
    • Journal of Acupuncture Research
    • /
    • v.28 no.6
    • /
    • pp.139-147
    • /
    • 2011
  • Objectives : In this research, relatively the characteristic in the combustion according to the brands of the commercial indirect moxibustion is compared and the commercial indirect moxibustion is standardized and this result tries to be provided as necessary basic data. Methods : After adhering to the agarose gel surface in which the thermocouple is inserted, 6 kinds of commercial indirect moxibustion were burnt off and the burning behaviour of the commercial indirect device and heat quantity of stimulus was compared. Results : 1. The form of combustion did not have a difference in 6 kinds of commercial indirect moxibustion combustion. 2. As to the miximum temperature, 'Seoam' and 'Dongbang' was higher than 'Baekryoung' and 'Taeyang'. 3. It was long so that the highest temperature reaching time of 'Seoam' could note in comparison with the other brands. And the highest temperature reaching time of 'Baekryoung' was short to note in comparison with the other brands. 4. As to the quantity of heat stimulus, 'Seoam' was the biggest and 'Baekryoung' was the smallest. 5. The quantity of heat stimulus of 'Dongbang' was the most stable. Conclusions : In this research, relatively the form of combustion of 6 kinds of commercial indirect moxibustion and heat quantity of stimulus were compared. It desires to anticipate the result that it makes the skin.

An Analysis of Emotional and Cognitive Factors on Acupuncture (침에 대한 정서와 인지요소 분석)

  • Chae, Youn-Byoung;Park, Hi-Joon;Kang, O-Seok;Lee, Jeong-Chan;Park, Kyung-Mo;Lee, Hye-Jung
    • Journal of Acupuncture Research
    • /
    • v.24 no.3
    • /
    • pp.215-229
    • /
    • 2007
  • Objectives : Placebo phenomena have been considered as a confounding factor of clinical trial. Expectancy and belief of acupuncture have not been evaluated quantitatively. The present study was performed to analyze the emotional and cognitive factor .of acupuncture and investigate whether the expectancy of acupuncture treatment is associated with the cognition of acupuncture. Methods : The expectancy and the perception of bodily sensation (PBS) of 22 participants were assessed using self-reported questionnaire. The subjects used the self assessment manikin (SAM) to rate each of the standard affective image of the international affective picture system (lAPS) and other acupuncture-related image. Based on the degree of expectancy, the high expectant (HE) and the low expectant (LE) group were classified. The thermal and pressure pain threshold was objectively evaluated using radiant-heat device and algometer. The degree of expected pain of acupuncture and the actual pain of painful stimulation was subjectively evaluated using facial pain scales (FPS). Results : Using SAlVI analysis, we identified the negative correlation between hedonic valence and arousal dimension on acupuncture-related visual cue. The degree of the PBS and general pain threshold did not show any significant difference between the HE and the LE group. The HE group rated the acupuncture images as more pleasant, more arousing, than the LE group. In addition, we also found that the higher expectancy marked the lower FPS of the expected pain of acupuncture, but not of the actual pain of painful stimulation. Conclusions : Our preliminary study identified the psychological dimensions of acupuncture-related visual cue. These findings indicate that the expectancy of acupuncture could affect the cognition of acupuncture.

  • PDF