• 제목/요약/키워드: thermal runaway current

검색결과 31건 처리시간 0.024초

배전용 ZnO 피뢰기 소자의 열적/전기적 파라미터 분석에 관한 연구 (A study on analysis of thermal and electrical parameters of the ZnO arrester block)

  • 이복희;이수봉;이승주;전병욱;김동성
    • 한국조명전기설비학회:학술대회논문집
    • /
    • 한국조명전기설비학회 2007년도 춘계학술대회 논문집
    • /
    • pp.353-356
    • /
    • 2007
  • This paper presents the thermal and electrical characteristics of ZnO arrester blocks under the AC voltages. The leakage currents of ZnO arrester blocks were measured as a function of time. The temperature distributions of ZnO arrester blocks were observed by the forward looking infrared camera The degradation and thermal runaway of ZnO arrester blocks were closely related with the temperature limit of ZnO arrester blocks which decided heat generation and dissipation As a result, the degradation and thermal runaway of ZnO arrester blocks depend on the temperature and leakage current of ZnO arrester blocks.

  • PDF

냉동기운전 고온초전도코일의 안전성평가기준에 관한 연구 (A Study on Stability Criterion for Cryocooler Operating HTS Coils)

  • 석산돈사;김석범;한경희
    • 대한전기학회논문지:전기물성ㆍ응용부문C
    • /
    • 제50권7호
    • /
    • pp.317-323
    • /
    • 2001
  • We investigated the stability of cryocooler-cooled high-temperature superconducting (HTS) coils by using a computer program based on FEM. In this study, the current at which "thermal runaway" occurs, which depends on the relationship between the cooling power of the cryocooler and the heat generation in HTS coils, was adopted as a stability criterion of cryocooler operating HTS coils. It was shown that cryocooler-cooled HTS coil was stable in operating current above the critical current from the numerical analysis results by HTS model coil. And also, if we efficiently remove the heat generation from HTS coils by potimizing heat drain, the ramp-rate limitation can be mitigated because the effect of AC loss by the current rise was too small. Furthermore, in the case of pulsed operation; the HTS model coil is ramped from zero to the peak value in one second and back to zero current in one second, such as the operation of SMES device, the peak value of poerating current is 1.5-2 times greater than that of the thermal runaway current.

  • PDF

ZnO 피뢰기 소자의 열적.전기적 특성 분석 (Analysis of Thermal and Electrical Characteristics of ZnO Arrester Blocks)

  • 이수봉;이복희
    • 조명전기설비학회논문지
    • /
    • 제21권10호
    • /
    • pp.82-88
    • /
    • 2007
  • 이 논문에는 교류전압에서 ZnO 피뢰기 소자의 열적 전기적 특성을 기술하였다. ZnO 피뢰기 소자의 누설전류는 시간의 변화에 따라 측정하였다. ZnO 피뢰기 소자의 온도분포를 열화상카메라에 의해 관측하였다. ZnO 피뢰기 소자의 열화 및 열폭주 현상은 열발생과 열방산을 결정짓는 ZnO 피뢰기 소자의 온도한계와 밀접한 관계가 있다. ZnO 피뢰기 소자의 저항은 ZnO 피뢰기 소자의 온도와 누설전류에 의해 민감하게 변화한다. 결론적으로 ZnO 피뢰기 소자의 열화 및 열폭주 현상은 ZnO 피뢰기 소자의 온도와 소자를 통해 흐르는 누설전류에 상당히 의존적인 것으로 나타났다.

주택용 분전반에 설치되는 서지보호기의 열적 안전성 시험 및 분석 (A thermal stability testing and analysis for a surge protector installed in residential distribution board)

  • 김주철;박장범;기채옥
    • 한국조명전기설비학회:학술대회논문집
    • /
    • 한국조명전기설비학회 2009년도 추계학술대회 논문집
    • /
    • pp.339-341
    • /
    • 2009
  • 개별세대 내 정보통신기기 및 홈네트워크 장비증가로 인하여 서지보호장치(SPD : Surge Protective Device)가 설치되고 있고 산업규격개정 및 등전위 접지시스템 강화에 따라 서지보호기 사용량은 점진적으로 증가하고 있다. 주택용 분전반에 설치되는 서지보호기의 부품은 전압제한형 소자인 $Z_nO$배리스터가 사용되고 있으나 일시적 과전압특성 (Temporary Overvoltage Characteristic) 위험에 노출되어있다. 본 논문은 일반주택에 사용되는 서지보호기의 열적 안전성 (Thermal Stability) 특성시험을 통하여 제품을 분석하였고 이를 토대로 개선안을 제시하였다. 분석결과 누설전류를 차단하기위한 가스 방전관(GDT) 사용 및 열폭주(Thermal Runaway) 현상을 막기 위한 안전장치가 2종 이상 필요하였다.

  • PDF

인청동 스위칭 모듈을 이용한 전력계통 및 전자기기 내부회로의 MOV 열폭주 방지와 안전성 개선 (Thermal Runaway Prevention of MOV and Safety Improvement of Power Line System and Internal Electronic Device Circuit Using a Phosphorous Switching Module)

  • 김주철;최경래;이상중
    • 조명전기설비학회논문지
    • /
    • 제25권9호
    • /
    • pp.75-79
    • /
    • 2011
  • The MOV(Metal Oxide Varistor), a voltage limiting element, has been installed in the SPD(Surge Protective Device) or inside the internal circuit of an electronic appliance for protection of the electric power system and electronic device against electrical surge. Such an MOV is exposed, however, to the risk of the thermal runaway resulting from excessive voltage and deterioration. In this paper, a reciprocal action has been tested and analyzed using a phosphorus bronze switching module and the low-temperature solder. And a short current break characteristic test linked with the circuit breaker has been performed to limit the inrush current when the MOV breaks down. It has been proven that the phosphorus bronze switching module installed inside the internal circuit can improve the safety of the power line system and the electronic device.

$Fe_2O_3$-$Bi_2O_3$ 소결체의 전기적 Switching 특성(II) (Electrical Switching Effects in the Sintered $Fe_2O_3$-$Bi_2O_3$ (II))

  • 정환재
    • 대한전자공학회논문지
    • /
    • 제17권1호
    • /
    • pp.36-39
    • /
    • 1980
  • 5Fe₂O₃-5Bi₂O₃소결체에서 V-I특성의 규격화, theramal current runaway의 인가 step 전압의 존성, current channel의 분석등을 연구하였다. 5Fe₂O₃-5Bi₂O₃소결체의 switching 특성의 측정으로부터 전기적 switching기구는 thermal ionic breakdown으로 설명된다.

  • PDF

태양광 패널 재사용을 위한 가변 정전류 기반의 효율 측정장치에 관한 연구 (Research on Variable Constant Current Efficiency Measuring Device for Solar Panel to Reuse)

  • 우상진;김대헌;이재진;권오민
    • 대한임베디드공학회논문지
    • /
    • 제18권1호
    • /
    • pp.9-17
    • /
    • 2023
  • This paper relates to the development of a device for measuring the efficiency of a solar panel based on a variable constant current, and proposed a standard for reuse of the solar panel. By applying a variable constant current circuit to a solar panel efficiency measuring device, it was easy to apply a maximum power point tracking (MPPT) algorithm. In addition, a load dispersion method was applied to measure the efficiency of a high-capacity solar panel. and it is possible to solve a problematic thermal runaway during a MOSFET parallel operation by applying the load dispersion method. As a result of the experiment, the solar panel efficiency measuring device was able to accommodate a large solar panel of 350W, which is the maximum measurement goal. In this paper, the validity was confirmed through the 310W solar panel efficiency measurement experiment collected after removal.

산화아연 피뢰기 소자의 열적 특성 분석 (Analysis of thermal characteristics of the ZnO arrester block)

  • 이복희;이수봉;이승주;전병욱;김동성;정동철
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2007년도 제38회 하계학술대회
    • /
    • pp.1393-1394
    • /
    • 2007
  • This paper presents the thermal characteristics of ZnO arrester blocks under the AC voltage. The leakage currents of ZnO arrester blocks were measured as a function of time. The temperature distribution of ZnO arrester blocks were observed by the forward looking infrared camera. The degradation and thermal runaway of ZnO arrester blocks were related to the temperature of ZnO arrster blocks which depended on heat generation and dissipation. As a result, the degradation and thermal runaway of ZnO arrester blocks are associated with the temperature and leakage current of ZnO arrester blocks.

  • PDF

현장 고장난 배전용 피뢰기의 특성분석 (Characteristic Analysis of Distribution Lighten ins Arrester Failed in the Field)

  • 김찬영;김주용;송일근;이병성;한재홍;윤태상
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2000년도 하계학술대회 논문집
    • /
    • pp.687-690
    • /
    • 2000
  • This paper provides the result of the analysis of the lightening arresters which were disconnected from the power line due to the overvoltage having high current. The effect of thermal runaway on the microstructures of lightening arrester's block was intensively investigated. The chance of the microstructures of the blocks was limited only on the breakdown paths and near them. Also even though a disconnector was disconnected from the arrester, some of the lightening arrester were showed normal characteristics.

  • PDF

산화아연 피뢰기 소자의 열적 특성 향상을 위한 연구 (A study on the improvement of the thermal properties of ZnO arrester blocks)

  • 김동성;이수봉;이승주;김동규;양순만;이복희
    • 한국조명전기설비학회:학술대회논문집
    • /
    • 한국조명전기설비학회 2009년도 추계학술대회 논문집
    • /
    • pp.335-338
    • /
    • 2009
  • In this study, in order to investigate the thermal and electrical properties of ZnO arrester block against 60[Hz] AC voltage, the changes in leakage current were measured. The temperature distribution appearing on the ZnO arrester blocks was observed using a forward looking infrared camera. In particular, the correlation between the thermal and electrical properties of a ZnO arrester block was analyzed experimentally. From this analysis, the thermal phenomena resulting from the heat generation and dissipation of the ZnO arrester block were interpreted. The degradation and thermal runaway phenomena of ZnO arrester block are closely related to the temperature limit of the ZnO arrester block. The installation of an additional metal electrode has resulted in the decrease of the leakage current due to the heat dissipation.

  • PDF