• Title/Summary/Keyword: thermal runaway

Search Result 82, Processing Time 0.023 seconds

Analysis of thermal characteristics of the ZnO arrester block (산화아연 피뢰기 소자의 열적 특성 분석)

  • Lee, Bok-Hee;Lee, Su-Bong;Lee, Seung-Ju;Jeon, Byung-Wook;Kim, Dong-Sung;Jung, Dong-Cheol
    • Proceedings of the KIEE Conference
    • /
    • 2007.07a
    • /
    • pp.1393-1394
    • /
    • 2007
  • This paper presents the thermal characteristics of ZnO arrester blocks under the AC voltage. The leakage currents of ZnO arrester blocks were measured as a function of time. The temperature distribution of ZnO arrester blocks were observed by the forward looking infrared camera. The degradation and thermal runaway of ZnO arrester blocks were related to the temperature of ZnO arrster blocks which depended on heat generation and dissipation. As a result, the degradation and thermal runaway of ZnO arrester blocks are associated with the temperature and leakage current of ZnO arrester blocks.

  • PDF

Thermal Hazard Evaluation on Self-polymerization of MDI

  • Sato, Yoshihiko;Okada, Ken;Akiyoshi, Miyako;Murayama, Satoshi;Matsunaga, Takehiro
    • International Journal of Safety
    • /
    • v.9 no.1
    • /
    • pp.6-11
    • /
    • 2010
  • Thermal analysis, heating test on gram scale and simulation of exothermic behavior based on kinetic analysis has been conducted in order to evaluate thermal hazards of self-polymerization of MDI. The exothermic reactions of MDI are expected to be the polymerization which forms carbodiimide and carbon dioxide, dimerization and trimerization. When MDI is kept in adiabatic condition during 1 week (10080 hours), the simulated result shows runaway reaction can occur in the case that initial temperature was more than $130^{\circ}C$. The relationship between the initial temperature (T, $^{\circ}C$) and TMR is given in a following equation. TMR=$4.493{\times}10^{-7}$ exp ($9.532{\times}10^3$/(T+273.15)) We propose that the relationship gives important criteria of handling temperature of MDl to prevent a runaway reaction.

A Study on the Design of Varistor Prevented from Thermal Runaway to Improve Safety (안정성 개선을 위해 열폭주 방지 기능을 내장한 배리스터 설계에 관한 연구)

  • Jung, Tae-Hun;Shin, Hee-Sang;Cho, Sung-Min;Lee, Hee-Tae;Lee, Jun-Kyu;Kim, Jae-Chul
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.24 no.2
    • /
    • pp.69-76
    • /
    • 2010
  • Recently, the natural environment changes drastically and the frequency of occurrence for lightning has gradually been increased. Such lightning delivers high volume of energy along the power line and communication line to the equipment in use. The high volume of energy arising from the lightning surge develops in fast velocity to destroy the facilities in power source and many other facilities in operation in sequential destruction with vast energy. This paper examines the characteristics of ZnO varistor to prevent from thermal runaway. We carry out performance evaluation of electrical characteristics on ZnO varistor. we will develop ZnO varistor Prevented from thermal explosion using test result of this paper.

Electrical Switching Effects in the Sintered $Fe_2O_3$-$Bi_2O_3$ (II) ($Fe_2O_3$-$Bi_2O_3$ 소결체의 전기적 Switching 특성(II))

  • 정환재
    • Journal of the Korean Institute of Telematics and Electronics
    • /
    • v.17 no.1
    • /
    • pp.36-39
    • /
    • 1980
  • Studies have been perfor mad on the normalization of V-I characteristics, the dependence of current runaway on the applied step voltage and the analysis of the current channet in the sintered 5Fe$_2$O$_3$-5Bi$_2$O$_3$. From the measurement of snitching Properties of the sintered 5Fe$_2$O$_3$-5Bi$_2$O$_3$, it is exe]twined that the electrical switching mechanism is that of thermal ionic breakolown.

  • PDF

Characteristic Analysis of Distribution Lighten ins Arrester Failed in the Field (현장 고장난 배전용 피뢰기의 특성분석)

  • 김찬영;김주용;송일근;이병성;한재홍;윤태상
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2000.07a
    • /
    • pp.687-690
    • /
    • 2000
  • This paper provides the result of the analysis of the lightening arresters which were disconnected from the power line due to the overvoltage having high current. The effect of thermal runaway on the microstructures of lightening arrester's block was intensively investigated. The chance of the microstructures of the blocks was limited only on the breakdown paths and near them. Also even though a disconnector was disconnected from the arrester, some of the lightening arrester were showed normal characteristics.

  • PDF

Research on Variable Constant Current Efficiency Measuring Device for Solar Panel to Reuse (태양광 패널 재사용을 위한 가변 정전류 기반의 효율 측정장치에 관한 연구)

  • Sang-Jin Woo;Dae-Heon Kim;Jae-Jin Lee;Oh-Min Kwon
    • IEMEK Journal of Embedded Systems and Applications
    • /
    • v.18 no.1
    • /
    • pp.9-17
    • /
    • 2023
  • This paper relates to the development of a device for measuring the efficiency of a solar panel based on a variable constant current, and proposed a standard for reuse of the solar panel. By applying a variable constant current circuit to a solar panel efficiency measuring device, it was easy to apply a maximum power point tracking (MPPT) algorithm. In addition, a load dispersion method was applied to measure the efficiency of a high-capacity solar panel. and it is possible to solve a problematic thermal runaway during a MOSFET parallel operation by applying the load dispersion method. As a result of the experiment, the solar panel efficiency measuring device was able to accommodate a large solar panel of 350W, which is the maximum measurement goal. In this paper, the validity was confirmed through the 310W solar panel efficiency measurement experiment collected after removal.

Thermal Distribution Analysis of Triple-Stacked ZnO Varistor (3층으로 적층된 ZnO 바리스터의 열분포 해석)

  • Kyung-Uk Jang
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.36 no.4
    • /
    • pp.391-396
    • /
    • 2023
  • Recently, as power and electronic devices have increased in frequency and capacity, it has become a major concern to protect electronic circuits and electronic components used in these devices from abnormal voltages such as various surges and pulse noise. To respond to variously rated voltages applied to power electronic devices, the rated voltages of various varistors can be obtained by controlling the size of internal particles of the varistor or controlling the number of layers of the varistor. During bonding, the problem of unbalanced thermal runaway occurring between the electrode and the varistor interface causes degradation of the varistor and shortens its life of the varistor. In this study, to solve the problem of unbalanced heat distribution of stacked varistors to adjust the operating voltage, the contents of the ZnO-based varistor composition were 96 wt% ZnO, 1 mol% Sb2O3, 1 mol% Bi2O3, 0.5 mol% CoO, 0.5 mol% MnO, and 1 mol% TiO2. A multi-layered ZnO varistor was modeled by bonding a single varistor with a composition in three layers according to the operating voltage. The thermal distribution of the triple-layered ZnO varistor was analyzed for the thermal runaway phenomenon that occurred during varistor operation using the finite element method according to Comsol 5.2.

Understanding Thermal Runaway Phenomena in Overcharged Lithium-Ion Batteries (리튬이차전지의 과충전에 의한 열폭주 현상의 이해)

  • Minseo Lee;Ji-sun You;Kyeong-sin Kang;Jaesung Lee;Sungyool Bong
    • Journal of the Korean Electrochemical Society
    • /
    • v.27 no.2
    • /
    • pp.55-72
    • /
    • 2024
  • Secondary batteries are used as an essential renewable energy source in our lives, such as electric vehicles and energy storage systems (ESS), as an alternative to fossil fuels due to global warming. However, cases of battery fires and explosions have been reported due to thermal runaway in secondary batteries due to various causes such as overdischarge, high-speed charging and discharging, and external short circuit, and great efforts are being made to find solutions suitable for each cause. In particular, as cases presumed to be caused by the overcharging process have been reported, this review will examine the chemical reactions of secondary batteries that can occur during the overcharging process and discuss risk investigation methods to check and prevent them.

Analysis of Thermal Runaway Phenomenon Caused by ZnO Varistor Operation Using Finite Element Method (유한요소법에 의한 ZnO 바리스터 동작 시 발생되는 열폭주 현상 해석)

  • Jang, Kyung-Uk
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.35 no.4
    • /
    • pp.372-376
    • /
    • 2022
  • Since the ZnO varistor is a semiconductor device, the internal thermal distribution during the varistor operation is recognized as an important factor in the performance and deterioration of the varistor. For an optimal varistor structure design, the thermal runaway phenomenon during the varistor operation was interpreted using the Comsol 5.2 analysis program by a finite element analysis. The maximum temperature of the center measured in the cross section of the ZnO varistor was confirmed to increase as the temperature moved from the lower electrode to the center towards the upper electrode up to 572.6 K. The electrodes are thinned so that the influence of the Schottky barrier is not great. The heat gradient balance is determined to be improved when the electrode of the hybrid form is introduced. The thickness, density, pore distribution, impurity uniformity, and particle size of the ZnO varistor are required, and it is determined that the pyrolysis gradient will be improved regardless of the electrode thickness. When these results are applied to design the ZnO varistor, the optimal structure of the ZnO varistor can be obtained.

Characteristics of Ceramic Separator Impregnated by Molten Salt for Thermal Batteries (열전지용 세라믹 분리막의 용융염 전해질 함침 특성)

  • Kang, Seung-Ho;Im, Chae-Nam;Park, Byung-Jun;Cho, Sung-Baek;Cheong, Hae-Won;Yi, Junsin
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.28 no.7
    • /
    • pp.467-472
    • /
    • 2015
  • Thermal batteries are primary power sources for military applications requiring high reliability, robustness and long storage life. Conventional electrodes for thermal batteries are prepared by compacting powder mixtures into pellets. Separator is composed of halide mixture, such as LiCl-KCl eutectic salt, blended with MgO to immobilize the molten salt. In order to increase the power density and energy density, the resistance of electrolyte should be reduced because the resistance of electrolyte is predominant in thermal batteries. In this study, wetting behaviors and impregnation weight of molten salts as well as the micro structures of ceramic felt were investigated to be applicable to thin electrolyte. Discharge performances of single cell with the ceramic separator impregnated by molten salt were evaluated also. Zirconia felt with high porosity and large pore outperformed alumina felt in wetting characteristics and molten salt impregnation as well as discharge performances. Based on the results of this study, ceramic felt separator impregnated with molten salt have revealed as an alternative of conventional thick MgO based separator with no conspicuous sign of thermal runaway by short circuit.