• Title/Summary/Keyword: thermal pressure relief device

Search Result 6, Processing Time 0.019 seconds

A Study on Performance of Pressure Relief Devices of CNG Cylinder Valves (CNG 용기용밸브의 압력방출장치 성능에 관한 연구)

  • Kim, Young-Seob;Kim, Lae-Hyun;Lee, Jae-Hun
    • Journal of the Korean Institute of Gas
    • /
    • v.13 no.4
    • /
    • pp.33-39
    • /
    • 2009
  • This study is intended to experiment performance of pressure relief device and to extend the effective ways to prevent cylinders of NGV from bursting when they are exposed to local fire intensively or when they are overcharged under ambient temperature at fueling stations in summer. In the results of thermal cycling experiments, all products of three companies met the requirements for gas leakage in the qualification criteria between $82^{\circ}C$ and $-40^{\circ}C$. But the o-rings of two companies' specimens among the three companies' specimens got damaged under the accelerated conditions between $135^{\circ}C$ and $-45^{\circ}C$. It took one minute and thirty nine seconds for a glass bulb type of a thermal sensitive type PRD to activate and it took two minutes and thirty one seconds for a fusible plug type of a thermal sensitive type PRD to activate. These results indicated that a glass bulb type of a thermal sensitive type PRD was one minute faster than a fusible plug type of a thermal sensitive type PRD. Under the accelerated condition $135^{\circ}C$, the activation pressure of a pressure sensitive type PRD burst at 32.1 MPa and, under the condition of qualification criteria, it burst from 30.7 MPa to 32.1 MPa.. As a result of the experiment for performance of pressure relief device, in the case of the thermal sensitive type PRD, a glass bulb type is more effective to flame than a fusible plug type. we confirmed that the rupture pressure of a pressure sensitive type PRD could not be affected by temperature and pressure cycling.

  • PDF

A Study for the Safety on the Flame Exposure of the Propane Cylinder (소형 프로판 용기의 화염 노출에 대한 안전성 연구)

  • Yim, Sang-Sik;Jang, Kap-Man;Lee, Jin-Han;Park, Gi-Dong;Kim, Ki-Bum
    • Journal of the Korean Institute of Gas
    • /
    • v.19 no.5
    • /
    • pp.36-40
    • /
    • 2015
  • To evaluate the safety of propane cylinder, the flame test was performed by the flame exposure scenario of propane cylinder. The cylinder which was exposed in a flame was rapidly occurred to increase the internal pressure by liquid expansion, if so it cause of physical explosion. Therefore, the cylinder which was applied with thermal pressure relief device sholud be not bursted and the propane should be discharged to outside safely. The flame average temperature that was around of cylinder is $600^{\circ}C$, and then it increased $700^{\circ}C$ by discharged propane. The result of flame test, the cylinder was deformed, but it was not bursted. The regulations of flame exposure test for propane cylinder were not restricted, this paper can be applied to restrict the flame test if the cylinder is possible to expose the flame. Also, the results is expected as reference for estimation of the pressure cylinder performance.

Analysis of Flow and Thermal Mixing Responses on Hot Water Discharge by Quencher Devices into an Annular Water pool (원환풀내에서 Quencher Device에 의한 고온수 분출로 일어나는 혼합유동에 관한 연구)

  • Choi, Seong-Seok;Kim, Jong-Bo
    • The Magazine of the Society of Air-Conditioning and Refrigerating Engineers of Korea
    • /
    • v.14 no.1
    • /
    • pp.21-30
    • /
    • 1985
  • One of the problems with the Boiling Water Reactor involves the flow and thermal mixings in the suppression water pool high pressure steam discharge into the pool in case of emergency core relief. Varioos heat sensitive devices and pumps for the reactor core cooling are installed in the middle of the suppression pool. Especially the pumps utilize pool water in order to cool the reactor core in emergency cases. In this case, the water temperature for the reactor cool ins should be below a certain temperature specified by the reactor design. In the present investigation, in other to determine the optimum locations of these pumping devices, numerical solutions have been obtained for the model to determine the f low mixing characteristics. Experimental investigations have also been carried out for the flow mixing and for the thermal mixing in the pool during the discharge. Considering that the discharge steam through the Quenching Device becomes hot water immediately in the water pool, the steam- equivalent hot water has been utilized. Examining these characteristices, it becomes possible to deform me the best locations for RCIC, LPCI , HPCI pumps in the suppression water pool for the emermency reactor core cooling.

  • PDF

The Evaluation of Fire Reliability for the High Pressure Hydrogen Storage System of Fuel Cell Vehicle (I) (연료전지자동차의 고압수소저장시스템 국부화재 신뢰성 평가 (I))

  • Kim, Sang-Hyun;Choi, Young-Min;Hang, Ki-Ho;Shim, Ji-Hyun;Hang, In-Cheol;Lim, Tae-Won
    • Journal of Hydrogen and New Energy
    • /
    • v.22 no.4
    • /
    • pp.520-526
    • /
    • 2011
  • In recent years, it is very important that hydrogen storage system is safe for user in any circumstances in case of crash and fire. Because the hydrogen vehicle usually carry high pressurized cylinders, it is necessary to do safety design for fire. The Global Technical Regulation (GTR) has been enacted for localized and engulfing fire test. High pressure hydrogen storage system of fuel cell electrical vehicles are equipped with Thermal Pressure Relief Device (TPRD) installed in pressured tank cylinder to prevent the explosion of the tank during a fire. TPRDs are safety devices that perceive a fire and release gas in the pressure tank cylinder before it is exploded. In this paper, we observed the localized and engulfing behavior of tank safety, regarding the difference of size and types of the tanks in accordance with GTR.

The Performance Characteristics of Anti-Surge Devices for High Head Cooling Water Systems in 1,000 MW Thermal Power plants (고수두 1,000 MW 석탄화력발전소 냉각수계통 수격방지장치의 성능특성)

  • Kim, Keun-Pil;Yoo, Hoseon
    • Plant Journal
    • /
    • v.15 no.4
    • /
    • pp.36-42
    • /
    • 2019
  • In recent, according to the tightening of environment regulation policy, the height of the site of the power plant is increased and the length of the cooling water pipe is increased. This has a serious impact on the stability of the plant. This study analyzes the transient phenomenon using LIQT 7.2, an unsteady state one-dimensional analysis software, to secure the stability of 1,000 MW high-capacity coal-fired power plant cooling water system with high head. To prevent water hammer, The effects on performance characteristics were predicted by individual and combination application. The surge pressure of the cooling water which occurs when the pump was stopped without installing the anti-surge devices was the largest at the pump outlet side. The most effective and simple way to reduce surge pressure in these cooling water systems is to combine a vacuum breaker with a hydraulic non-return valve, which is an essential device for pump protection.

Effect of Mechanical Thermal Massage Inducing Gradual Spinal Segmentation on the Improvement of Pain (단계적 척추 분절운동을 유도하는 기계식 온열 마사지가 통증 개선에 미치는 영향)

  • Hyeun-Woo, Choi;Do-Hyun, Ahn;Kyung-Mi, Jung;Na-Young, Kim;Ji-Eun, Lee;Jong-Min, Lee
    • Journal of the Korean Society of Radiology
    • /
    • v.16 no.7
    • /
    • pp.879-887
    • /
    • 2022
  • In this study, we tried to confirm whether the mechanical sequential elevation method of the body pressure measuring bed actually induces segmental motion for each part of the spine. To this end, a lateral X-ray examination was performed, and it was confirmed that the sequential pressure device induces a step-wise segmentation of the spine by mechanically lifting each part of the spine vertically. Then, pain, walking ability, and depression scale were measured and analyzed in subjects who were aware of back pain. VAS(p<0.05) and ODI(p<0.05) for 10 days tended to decrease in average after bed use. In the gait ability test(p<0.05), as the number of times of bed use increased, the moving time in the test decreased and the moving distance increased. In addition, GSDDF(p<0.05) decreased after bed use. As a result, it was confirmed that the spinal segmentation caused by the heat and acupressure provided by the bed affected gait and depression as well as pain relief.