• 제목/요약/키워드: thermal power plant

검색결과 1,086건 처리시간 0.028초

접시형 태양열 발전시스템에서 사용하는 여러 가지 형태의 태양추적시스템의 태양추적성능 분석 (Analysis of Sun Tracking Performance of Various Types of Sun Tracking System used in Parabolic Dish Type Solar Thermal Power Plant)

  • 서동혁;박영칠
    • 제어로봇시스템학회논문지
    • /
    • 제17권4호
    • /
    • pp.388-396
    • /
    • 2011
  • Sun tracking system is the most important subsystem in parabolic dish type solar thermal power plant, since it determines the amount of thermal energy to be collected, thus affects the efficiency of solar thermal power plant most significantly. Various types of sun tracking systems are currently used. Among them, use of photo sensors to located the sun(which is called sensor type) and use of astronomical algorithm to compute the sun position(which is called program type) are two of the mostly used methods. Recently some uses CCD sensor, like CCD camera, which is called image processing type sun tracking system. This work is concerned with the analysis of sun tracking performance of various types of sun tracking systems currently used in the parabolic dish type solar thermal power plant. We first developed a sun tracking error measurement system. Then, we evaluate the performance of five different types of sun tracking systems, sensor type, program type, hybrid type(use of sensor and computed sun position simultaneously), tracking error compensated program type and image processing type. Experimentally obtained data shows that the tracking error compensated program type sun tracking system is very effective and could provide a good sun tracking performance. Also the data obtained shows that the performance of sensor type sun tracking system is being affected by the cloud significantly, while the performance of a program type sun tracking system is being affected by the sun tracking system's mechanical and installation errors very much. Finally image processing type sun tracking system can provide accurate sun tracking performance, but costs more and requires more computational time.

원자력발전소의 온배수 배출량을 고려한 어업생산감소율 추정 모델 (A Quantitative Model for Estimating Fishery Production Damages as a Result of Thermal Effluents from Nuclear Power Plants)

  • 장창익;이성일;이종희
    • 한국수산과학회지
    • /
    • 제42권5호
    • /
    • pp.494-502
    • /
    • 2009
  • A quantitative model was developed in order to estimate fishery production damage due to anthropogenically induced environmental changes. The model is described in the following equation, $Y_D=\frac{{\phi}_D}{{\phi}_G}[Y_0{\cdot}(t_p-t_0)-\frac{Y_0}{{\phi}_G}(1-e^{-{\phi}_G(t_p-t_0)})]$, where, $Y_D$ is annual amount of fishery production by nuclear power plant. ${\varphi}$ D and ${\varphi}$ G are instantaneous decreasing coefficient of fishery production by nuclear power plant and instantaneous decreasing coefficient of gross fishery production, respectively. $Y_0$ is annual mean fishery production without damages. $t_p$ is the present time, and $t_0$ is the starting time of damages. The model was applied to fishing grounds near a nuclear power plant on the east coast of Korea. Since fishery production damages have become bigger with increasing emission of thermal effluents from generators activities in the power plant, this factor has also been considered as, $\delta_{D_i}=\delta_D\({\sum}\limits_{i=0}^{n}\;W_i/W_T\)$, where, $\delta_{Di}$ is the cumulative damage rate in fishery production from generators, $\delta_D$ is the total cumulative damage rate in fishery production, $W_i$ is the emission amount of thermal effluents by generator i, and n is the number of generators in the nuclear power plant. This model can be used to conduct initial estimates of fishery production damages, before more detailed assessments are undertaken.

증기터빈의 오일 휩 현상 및 대책

  • 구재량
    • 열병합발전
    • /
    • 통권37호
    • /
    • pp.18-21
    • /
    • 2004
  • There are several bearing system at large steam-turbines in thermal power plant. The bearing system is one of the most important parts of rotating machinery. The steam turbine vibrations mainly depend on the bearing oil the shaft alignment condition. This paper describes on the steam turbine abnormal vibration due to the oil whip in terms of the shaft alignment in the thermal power plant.

  • PDF

태안화력발전소 주변 해조군집의 생태 연구 (Ecological Study of the Marine Algal Community at the Coast of Taean Thermal Power Plant, Korea)

  • 유종수;김영환
    • ALGAE
    • /
    • 제18권4호
    • /
    • pp.311-320
    • /
    • 2003
  • The community structure of benthic marine algae was investigated at Taean Thermal Power Plant and other places around Taean Peninsula, the west coast of Korea. Total of 100 species including 3 Cyanophyta, 14 Chlorophyta, 18 Phaeophyta, and 65 Rhodophyta were identified. The number of species was highest with 78 species at the Power Plant intake, followed by 61 at the discharge, 56 at Bunjeondo, and 50 at Maoe. It was noteworthy that a subtropical species Caulerpa okamurae was collected at the intake in autumn and it was the first observation in the west coast of Korea. The pattern of vertical algal distribution showed Gloiopeltis furcata occurred in the upper intertidal zone, Sargassum thunbergii and Corallina spp. in the middle and lower zone and Enteromorpha spp. in the lower middle zone. These were all dominant species except for Enteromopha spp., which was subdominant species. Other subdominant species were Chondrus ocellatus and Neorhodomela aculeata. The average diversity indices were between 0.70 and 1.20 at each area based on their dry weight. The similarity index was 0.79 between the algal flora of this study and that of 1987, indicating that the condition of the benthic environment remained unchanged since then. This area maintained its environmental quality, so the algal community remained same with similar structure. This study area seemed a suitable place for long term monitoring of the benthic environment where industrial facilities such as a power plant might affect the benthic algal community.

Effect of thermal aging on the mechanical, intergranular corrosion and corrosion fatigue properties of Z3CN20.09M cast duplex stainless steel

  • Ti, Wenxin;Wu, Huanchun;Xue, Fei;Zhang, Guodong;Peng, Qunjia;Fang, Kewei;Wang, Xitao
    • Nuclear Engineering and Technology
    • /
    • 제53권8호
    • /
    • pp.2591-2599
    • /
    • 2021
  • The effect of thermal aging at 475 ℃ and 750 ℃ of Z3CN20.09M cast duplex stainless steel (CDSS) on microstructure, mechanical and intergranular corrosion properties were investigated by transmission electron microscope (TEM), nano indenter, scanning electron microscope (SEM) and corrosion fatigue test system. The result indicated that the spinodal decomposition and G precipitated were occurred after aged at 475 ℃, as well as sigma precipitated at 750 ℃. The microstructure degeneration of ferrite was saturated after aged for 2000h and 200 h at 475 ℃ and 750 ℃ respectively. The mechanical properties, intergranular corrosion resistance and corrosion fatigue lives were continuing deteriorated with increasing the aging time at both temperatures. The difference of the degeneration mechanisms of Z3CN20.09M CDSS aged at 475 ℃ and 750 ℃ was analyzed.

Automatic adjustment of feedforward signal in boiler controllers of thermal power plants

  • Egashira, Katsuya;Nakamura, Masatoshi;Eki, Yurio;Nomura, Masahide
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 1995년도 Proceedings of the Korea Automation Control Conference, 10th (KACC); Seoul, Korea; 23-25 Oct. 1995
    • /
    • pp.83-86
    • /
    • 1995
  • This paper proposes an auto-tuning method of feedforward signal in boiler control of thermal power plants by using the neural network. The neural network produces an optimal feedforward signal by tuning the weights of the network. The weights are adapted effectively by using the teaching signal of PI control output. The proposed method was evaluated based on a detailed simulator which expressed non-linear characteristics of the 600 MW actual thermal power plant at load chaning operations, showed effectiveness in the learning of the weights of the neural network, and gave an accurate control performance in the temperature control of the system. Through the evaluation, the proposed method was proved to be effectively applicable to the actual thermal plants as the automatic adjustment tool.

  • PDF

기력발전소 터빈조속기 제어로직 개선에 의한 발전기 부하추종성 향상 (계통주파수저하방지) (Load Following Operation Improvement by Governor Control Logic Modification of Thermal Power Plant (System Frequency Drop Prevention))

  • 이종하;김태웅
    • 전력전자학회논문지
    • /
    • 제11권4호
    • /
    • pp.302-306
    • /
    • 2006
  • 기력발전소의 부하추종성능의 향상은 계통의 전력품질에 지대한 영향을 미치기 때문에 이를 위해서는 먼저 보일러, 터빈, 조속기 시스템과 제어알고리즘에 대한 분석이 필히 선행되어야 한다. 기력발전설비는 다양한 제어가구들 에 의해 운영되고 있고 조속기가 고장 난 경우에는 문제를 해결하는데 많은 시간이 필요하여 발전설비를 정지하지 않고서는 메커니즘 정비가 불가능하다. 계획되지 않은 발전시스템의 정지는 전력발전의 감소로 인해 경제적인 문제뿐만 아니라 전력공급의 차질에 지대한 지장을 주기 때문에 충분히 고려할 사항이다. 본 논문에서는 표준석탄화력 500MW 발전설비 ( 삼천포화력발전소 )에 있어서 계통주파수가 과다하게 장시간 저하될 경우에 기력발전기 제어특성이 나빠져 발전기의 출력이 저하되는 데 이에 대한 현상을 추이분석과 함께 제어로직의 분석 및 개선을 통해 계통 주파수가 저하되는 것을 방지하였고 이에 대한 사례를 소개한다.

화력발전소 부하조절기 자동추동장치에 의한 계통주파수 개선에 관한 연구 (Improvement in Power System Frequency Control by Automatic Follow-up Regulator of Thermal Power Plant)

  • 권욱현;황재호
    • 대한전기학회논문지
    • /
    • 제40권1호
    • /
    • pp.10-17
    • /
    • 1991
  • An improved control method in turbine control system is proposed. By automatic follow-up design, power system frequency may be maintained within prespecified range. Base or half load control is possible by distributing power plant load allotment. Otherwise, diminutive frequency-load control is dine by governor-free operation in power plant. This paper proposes governor-free operation which is automatically followed by load-limitter setter. The condition which limits governor action may be somewhat improved within boiler condition by this idea. This design has been implemented at Samchunpo thermal power plant. The improved practical results are shown.

  • PDF

Development of superconducting high gradient magnetic separation system for scale removal from feed-water in thermal power plant

  • Shibatani, Saori;Nakanishi, Motohiro;Mizuno, Nobumi;Mishima, Fumihito;Akiyama, Yoko;Okada, Hidehiko;Hirota, Noriyuki;Matsuura, Hideki;Maeda, Tatsumi;Shigemoto, Naoya;Nishijima, Shigehiro
    • 한국초전도ㆍ저온공학회논문지
    • /
    • 제18권1호
    • /
    • pp.19-22
    • /
    • 2016
  • A Superconducting High Gradient Magnetic Separation (HGMS) system is proposed for treatment of feed-water in thermal power plant [1]. This is a method to remove the iron scale from feed-water utilizing magnetic force. One of the issues for practical use of HGMS system is to extend continuous operation period. In this study, we designed the magnetic filters by particle trajectory simulation and HGMS experiments in order to solve this problem. As a result, the quantity of magnetite captured by each filter was equalized and filter blockage was prevented. A design method of the magnetic filter was proposed which is suitable for the long-term continuous scale removal in the feed-water system of the thermal power plant.